FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ecolink Intelligent Technology, Inc./
  3. XQC-WST302

XQC-WST302SHOCK SENSOR

Ecolink Intelligent Technology, Inc.
SHOCK SENSOR - FCC ID XQC-WST302 - Ecolink Intelligent Technology, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Nov 24, 2015
Application Purpose
Original Equipment
Date of Application
Nov 23, 2015
Equipment Note
SHOCK SENSOR
Frequency Range
345.00000000 - 345.00000000
Company
Ecolink Intelligent Technology, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Ecolink Intelligent Technology, Inc. Page 1 of 2 2055 Corte Del Nogal Carlsbad, CA 92011 October 27, 2014 UL Verification Services Inc. Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;

Cover Letter(s)

2055 Corte Del Nogal Carlsbad, CA 92011 (760) 431-8804 November 20, 2015 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: XQC-WST302 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request, for 180 days from date of equipment authorization, on the following attachments: External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Jay Stone Director of Engineering Ecolink Intelligent Technology, Inc. 11/20/2015

External Photos

      

Test Report

NVLAP Lab code: 200246-0 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR Shock Sensor MODEL NUMBER: WST-302 FCC ID: XQC-WST302 IC: 9863B-WST302 REPORT NUMBER: R10744421-Revision A ISSUE DATE: 2015-11-25 Prepared for ECOLINK INTELLIGENT TECHNOLOGY 2055 CORTEL DEL NOGAL CARLSBAD CA 92011, U.S.A. Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 Revision History REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 2 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. Rev. Issue Date Revisions Revised By -- 2015-11-19 Initial Issue M.Ferrer A 2015-11-25 Updated Antenna Gain & Tx Radiated Spurious table on page 22 M.Ferrer REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 3 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT .............................................................................................. 7 5.2. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 7 5.3. SOFTWARE AND FIRMWARE .................................................................................... 7 5.4. WORST-CASE CONFIGURATION AND MODE .......................................................... 7 5.5. MODIFICATIONS ........................................................................................................ 7 5.6. DESCRIPTION OF TEST SETUP ................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................10 7. ANTENNA PORT TEST RESULTS ...................................................................................11 7.1. 20 dB AND 99% BW ...................................................................................................11 7.2. DUTY CYCLE .............................................................................................................15 7.3. TRANSMISSION TIME ...............................................................................................21 8. RADIATED EMISSION TEST RESULTS...........................................................................22 8.1. TX RADIATED SPURIOUS EMISSION ......................................................................22 9. SETUP PHOTOS ...............................................................................................................28 REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 4 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ECOLINK INTELLIGENT TECHNOLOGY 2055 CORTE DEL NOGAL CARLSBAD CA, 92011, U.S.A. EUT DESCRIPTION: WIRELESS SHOCK AND CONTACT SENSOR MODEL: WST-302 SERIAL NUMBER: 11 FE 15 (Continuous Tx sample); 13 MY 15 & sample ID 2236718 (Factory firmware samples) DATE TESTED: October 6-13 and 29, 2015 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 4 Pass UL LLC tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL LLC. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL LLC. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL LLC By: Tested & Prepared By: Mike Ferrer Mark Nolting EMC Program Manager EMC Engineer UL – Consumer Technology Division UL – Consumer Technology Division REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 5 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY The tests documented in…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 28 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 9. SETUP PHOTOS ANTENNA PORT ANTENNA PORT REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 29 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 30 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 31 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 32 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION BELOW 1000 MHz RADIATED EMISSIONS BELOW 1000MHz (FRONT) REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 33 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSIONS BELOW 1000MHz (BACK) REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 34 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION ABOVE 1000 MHz RADIATED EMISSIONS ABOVE 1000 MHz (FRONT) REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 35 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSIONS ABOVE 1000 MHz (BACK) REPORT NO: R10744421A DATE: 2015-11-25 FCC ID: XQC-WST302 IC: 9863B-WST302 Page 36 of 36 UL LLC FORM NO: 03-EM-F00858 12 LABORATORY DR., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. END OF REPORT

Contact Information

Applicant

Jay Stone
[email protected]760-431-8804Fax: 760-431-8975

Test Firm

UL LLCRick Titus
[email protected]847-664-3281Fax: 847-509-6321

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-
Confidentiality
Long Term

Other Applications from Ecolink Intelligent Technology, Inc.

Wearable Action Button - FCC ID XQC-WST132 - Ecolink Intelligent Technology, Inc.
XQC-WST132

Wearable Action Button

Feb 07, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor - FCC ID XQC-WST621 - Ecolink Intelligent Technology, Inc.
XQC-WST621

Flood and Freeze Sensor

May 01, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST740 - Ecolink Intelligent Technology, Inc.
XQC-WST740

Motion Detector

Jul 04, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST742 - Ecolink Intelligent Technology, Inc.
XQC-WST742

Motion Detector

Feb 17, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector - FCC ID XQC-CS602 - Ecolink Intelligent Technology, Inc.
XQC-CS602

Audio Detector

Feb 17, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter