FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ecolink Intelligent Technology, Inc./
  3. XQC-WST602

XQC-WST602Detector of Smoke Detector Alarm Tones

Ecolink Intelligent Technology, Inc.
Detector of Smoke Detector Alarm Tones - FCC ID XQC-WST602 - Ecolink Intelligent Technology, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 05, 2013
Application Purpose
Original Equipment
Date of Application
Sep 05, 2013
Equipment Note
Detector of Smoke Detector Alarm Tones
Frequency Range
345.00000000 - 345.00000000
Company
Ecolink Intelligent Technology, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Audio Detector WST-602 Specifications Frequency: 345MHz Operating Temperature: 32°-120°F (0°-49°C) Battery: 3V lithium CR123A Operating Humidity: 5-95% RH non condensing Battery life: 5 years Compatible with 2GIG and Honeywell receivers Detection distance: 6 in max Supervisory signal interval: 64 min(approx.) Operation The FireFly is designed to listen to the alarm sounder of any smoke detector. Once confirmed as an alarm, it will transmit a signal to the alarm control panel which if connected to a central monitoring station, will dispatch the fire department. Enrolling To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual for details on these menus. For panels with a learn feature, once prompted by the control panel, press the small button located on the device to trigger a transmission. Or you can manually enter the serial number printed on the back of each unit. This product enrolls as a 5816 and uses Loop 1 to transmit alarm signals. Mounting Included with this device is a mounting bracket, hardware and double sided tape. To ensure proper operation ensure the side of the device with the small holes is directly facing the sounder holes on the smoke detector. The FireFly must be mounting within 6 inches of the detector for optimal operation. Testing To test the RF transmission from the mounted position you can either generate a tamper by removing the cover or press the small button within the device. This will send a signal to the control panel. To test the audio detection, press and hold the smoke detector test button. Ensure the FireFly cover is on and that you wear hearing protection. When a signal is detected the LED on the device will start to flash, once it has determined it’s a valid smoke alarm signal the LED will turn on steady and transmit a signal to the control panel. Replacing the Battery When the battery is low a signal will be sent to the control panel. To replace the battery: 1. Remove the top cover to reveal the battery. This will send a tamper signal to the control panel. 2. Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device. 3. Re-attached the cover, you should hear a click when the cover engages properly. FCC Compliance Statement This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Re-orient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Connect the equipment to an outlet on a different circuit from the receiver  Consult the dealer or an experienced radio/TV contractor for help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID: XQC-WST602 IC:9863B-WST602 Warranty Ecolink Intelligent Technology Inc . warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use within the warranty period Ecolink Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink Intelligent Technology Inc. neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue shall be limited to a replacement of the defective product . It is recommended that the customer check their equipment on a regular basis for proper operation. © 2013 Ecolink Intelligent Technology Inc. PN WST602 R1.00 2055 Corte Del Nogal Carlsbad, California 92011 1-855-632-6546 www.discoverecolink.…

Text truncated - open the document above for the full version.

Cover Letter(s)

Ecolink Intelligent Technology, Inc. Page 1 of 2 2055 Corte Del Nogal Carlsbad, CA 92011 July 15, 2013 UL LLC Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL LLC on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL LLC as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;

Parts List/Tune Up Info

Antenna Specification WST - 602 Rev 1 July 11, 2013 The WST-602 transmitter uses a small loop antenna (-15 dBi). The loop is formed by a copper trace on the printed circuit board and a piece of copper-clad wire. The antenna is not replaceable by the user.

Test Report

NVLAP Lab code: 100414-0 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR Detector of Smoke Detector Alarm Tones MODEL NUMBER: WST-602 FCC ID: XQC-WST602 IC: 9863B-WST602 REPORT NUMBER: 13U15669-1 Order NUMBER: 10035572 ISSUE DATE: August 28, 2013 Prepared for Ecolink Intelligent Technology 2055 Corte Del Nogal Carlsbad, CA 92011 Prepared by UL LLC 333 Pfingsten Rd. Northbrook, IL 60062 TEL: (847) 272-8800 REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 2 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. Revision History Rev. Issue Date Revisions Revised By -- 08/28/13 Initial Issue M.Ferrer REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 3 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 5 5. EQUIPMENT UNDER TEST ............................................................................................... 6 5.1. DESCRIPTION OF EUT .............................................................................................. 6 5.2. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 6 5.3. SOFTWARE AND FIRMWARE .................................................................................... 6 5.4. WORST-CASE CONFIGURATION AND MODE .......................................................... 6 5.5. MODIFICATIONS ........................................................................................................ 6 5.1. DESCRIPTION OF TEST SETUP ................................................................................ 7 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9 7. TEST RESULTS ................................................................................................................10 7.1. 20 dB AND 99% BW ...................................................................................................10 7.2. DUTY CYCLE .............................................................................................................14 7.3. TRANSMISSION TIME ...............................................................................................18 8. RADIATED EMISSION TEST RESULTS...........................................................................19 8.1. TX RADIATED SPURIOUS EMISSION ......................................................................19 9. SETUP PHOTOS ...............................................................................................................25 REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 4 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Ecolink Intelligent Technology 2055 Corte Del Nogal Carlsbad, CA 92011 EUT DESCRIPTION: Detector of Smoke Detector Alarm Tones MODEL: WST-602 SERIAL NUMBER: N/A DATE TESTED: July 25, 2013 – August 20, 2013 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 3 Pass UL Verification Services Inc tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Verification Services Inc By: Tested By: BART MUCHA MICHAEL FERRER Staff Engineer Project Lead UL Verification Services Inc. UL Verification Services Inc. REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 5 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY The tests documented in th…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 25 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. 9. SETUP PHOTOS Near Field Measurements REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 26 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 27 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 28 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 29 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSION RADIATED EMISSIONS All antennas were used at 3m REPORT NO: 13U15669-1 DATE: August 28, 2013 FCC ID: XQC-WST602 IC: 9863B-WST602 Page 30 of 30 UL LLC FORM NO: CCSUP4701G 333 Pfingsten Rd., Northbrook, IL 60062 TEL: (847) 272-8800 This report shall not be reproduced except in full, without the written approval of UL LLC. END OF REPORT

Contact Information

Applicant

Jay Stone
[email protected]760-431-8804Fax: 760-431-8975

Test Firm

UL LLCRick Titus
[email protected]847-664-3281Fax: 847-313-3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-
Confidentiality
Long Term

Other Applications from Ecolink Intelligent Technology, Inc.

Wearable Action Button - FCC ID XQC-WST132 - Ecolink Intelligent Technology, Inc.
XQC-WST132

Wearable Action Button

Feb 07, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor - FCC ID XQC-WST621 - Ecolink Intelligent Technology, Inc.
XQC-WST621

Flood and Freeze Sensor

May 01, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST740 - Ecolink Intelligent Technology, Inc.
XQC-WST740

Motion Detector

Jul 04, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST742 - Ecolink Intelligent Technology, Inc.
XQC-WST742

Motion Detector

Feb 17, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector - FCC ID XQC-CS602 - Ecolink Intelligent Technology, Inc.
XQC-CS602

Audio Detector

Feb 17, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter