Coverage Pattern: Top View Side View WST-702 Wireless PIR Motion Sensor with Pet Immunity Installation Instructions Specifications Frequency: 345 MHz Operating Temperature: 32°-120°F (0°-49°C) Battery: One 3Vdc Lithium CR-123A (1550 mAh) Operating Humidity: 5-95% RH non-condensing Battery life: 5 years Compatibility: Honeywell and 2GIG receivers Pet Immunity: 50 lbs (22 kg) Supervisory interval: 60 min(approx.) Coverage Area: 40 x 40 feet (12m), 90 degree angle Light Immunity: 2000 lux (EN50131-2-4) Enrollment: To enroll the motion sensor, set your panel into programming mode. Refer to the manual for your specific alarm control panel for details on programming mode. When prompted by the panel, enter the 7 digit serial number which is printed on the sensor label. Make sure the loop number is set to Loop 1. Alternatively, the motion sensor can be enrolled by triggering wireless transmissions. To do this, hold down the tamper button on the sensor while inserting the battery. The red LED will begin to flash. After 30 seconds the red LED will stop flashing and the sensor can be triggered by waving your hand in front of the motion sensor. The sensor will transmit every time motion is detected. Trigger the motion sensor as many times as is required by your panel until the panel recognizes the sensor’s serial number. Sensitivity Jumper Settings: For normal sensitivity motion detection leave the jumper in the default setting (on). Remove the jumper if increased sensitivity to movement is desired. Mounting: Mount the motion sensor at 7.5 feet (2.3 meters) above the floor. Remove the sensor cover to expose the circuit board then remove the circuit board from the back cover by gently pressing that plastic tab as shown in the diagram. With the board removed you have access to both the flush mount and corner mount screw knock outs. Remove the appropriate knockouts and use the included screws to mount in the desired mounting location. It is recommend to ensure there is a tight seal around the knockouts to prevent bugs from entering the sensor and causing false alarms. Replace the circuit board and snap the front cover onto the back cover. Walk Test Mode: Walk test mode can be used to test the motion sensor detection coverage area. To enter walk-test mode hold down the tamper button while inserting the battery. The red LED will begin to flash indicating that the motion sensor is warming up. After 30 seconds the LED no longer flashes and the motion sensor is ready to detect motion. The LED will illuminate each time motion is detected. Once the LED goes out, the sensor is ready to detect motion again. Walk test mode ends after twenty motion detections or if no motion is seen for two minutes. Sensitivity Jumper Push tab to remove PCB Sensitivity jumper Operation: During normal operation, the LED will not turn on even if motion is detected. This is done to maximize battery life. Furthermore when motion is detected and a signal is transmitted to the panel, the sensor will not transmit again for a period of three minutes. Replacing the Battery: When the battery is low, a signal will be sent to the control panel. To replace the battery remove the front cover to expose the battery, the replace with a CR123A lithium battery. Note the correct orientation of the battery as shown on the circuit board. FCC / Industry Canada Compliance Statement This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment to an outlet on a different circuit from the receiver • Consult the dealer or an experienced radio/TV contractor for help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID:XQC-WST702 IC: 9863B-WST702 Warranty Ecolink Intelligent Technology Inc. warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmansh…
Text truncated - open the document above for the full version.
Ecolink Intelligent Technology, Inc. Page 1 of 2 2055 Corte Del Nogal Carlsbad, CA 92011 October 27, 2014 UL Verification Services Inc. Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;
WST-702 Label
FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS 210 CERTIFICATION TEST REPORT FOR WIRELESS SENSOR MODEL NUMBER: WST-702 FCC ID: XQC-WST702 IC: 9863B-WST702 REPORT NUMBER: 14U19270 REVISION A ISSUE DATE: DECEMBER 3, 2014 Prepared for ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD CA, 92011, U.S.A Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 2 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. Revision History Rev. Issue Date Revisions Revised By -- 11/17/14 Initial Issue P. ZHANG A 12/3/14 Updated standard version P. ZHANG REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 3 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................. 5 4.2. SAMPLE CALCULATION ........................................................................................... 5 4.3. MEASUREMENT UNCERTAINTY .............................................................................. 6 REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 4 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD, CA, 92011, U.S.A EUT DESCRIPTION: WIRELESS SENSOR MODEL: WST-702 SERIAL NUMBER: NON-SERIALIZED PRODUCTION UNIT. DATE TESTED: NOVEMBER 12-13, 2014 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 4 Pass UL Verification Services Inc tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Verification Services Inc By: Tested By: PENG ZHANG CHARLES VERGONIO PROJECT LEAD LAB ENGINEER UL Verification Services Inc. UL Verification Services Inc. REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 5 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.4-2009, FCC CFR 47 Part 2, FCC CFR 47 Part 15, RSS-GEN Issue 4, and RSS-210 Issue 8. 3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 47173 Benicia Street, Fremont, California, USA. The test sites and measurement facilities used to collect data are located at 47173 and 47266 Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the 47173 address. The following table identifies which facilities were utilized for radiated emission measurements documented in this report. Specific facilities are also identified in the test results sections. 47173 Benicia Street 47266 Benicia Street Chamber A Chamber D Chamber B Chamber E Chamber C Chamber F UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm. 4. CALIBRATION AND UNCERTAINTY 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. 4.2. SAMPLE CALCULATION Where relevant, the following sample calculation is provided: Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) + Cable Loss (dB) – Preamp Gain (dB) 36.5 dBuV + 18.7 dB/m +…
Text truncated - open the document above for the full version.
REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 29 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 9. SETUP PHOTOS ANTENNA PORT ANTENNA PORT REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 30 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 31 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 32 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 33 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION BELOW 30 MHz RADIATED EMISSIONS BELOW 30MHz (FRONT) REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 34 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS BELOW 30MHz (BACK) REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 35 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION ABOVE 30 MHz RADIATED EMISSIONS ABOVE 30 MHz (FRONT) REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 36 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS ABOVE 30 MHz (BACK) REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 37 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS ABOVE 1000 MHz (FRONT) REPORT NO: 14U19270 DATE: DEC 3, 2014 FCC ID: XQC-WST702 IC:9863B-WST702 Page 38 of 38 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. END OF REPORT RADIATED EMISSIONS ABOVE 1000 MHz (BACK)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 345 MHz - 345 MHz | - |

Wearable Action Button
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Motion Detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Motion Detector
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter