Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 1 of 7 AF 4037 Exterior Pictures Right Side Left Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 2 of 7 Top Side Bottom Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 3 of 7 Front Side Back Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 4 of 7 Node A Chassis Exterior Pictures Right Side Left Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 5 of 7 Top Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 6 of 7 Bottom Side 11.03.11 S:\Allgemein\Projects\E_Projects_Finished\800581 Node A\QA\FCC_IC\Docu_for_FCC_DCMAF4037W4\external pictures\External_Photos.doc Page 7 of 7 Front Side Back Side
Label location Node A System with DCM AF 4037 RF-card
RF Exposure Info / MPE Sample Calculation Model: AF 4037 FCC‐ID: XS5‐AF4037W4 The Node A is designed to amplify signals between multiple mobiles and a base station. The unit consists of a filter and amplifier chain in the downlink and one filter and amplifier chain in the uplink. The uplink and downlink paths are connected via a duplexer on both ends of each path. After that the signals are combined by the crossband coupler with the other frequency bands. In the uplink path, a signal originating from the mobile is divided by the crossband coupler into the different frequency bands and is separated from the downlink signal via the UL IN duplexer. It is then amplified by a low noise amplifier (LNA), which is part of the RF ca rd. The RF card down‐converts the signals to the IF and converts the analogue signal into a digital signal. This signal is forwarded to the Main Board, where digital filtering takes place. After the digital signal processing the signals comes back to the RF card, where the digital signal is converted into an analogue signal, is up‐converted and amplified. Finally, the signal is sent to the PA and combined with the downlink signal. After that the signals from all RF cards are combined at the crossband coupler and forwarded to the Base Station port of the Node A system. In the downlink path, a signal originating from the base station is divided by the crossband coupler into the different frequency bands and is separated from the uplink signal in the donor duplexer. It is then amplified by a low noise amplifier (LNA), which is part of the RF card. The RF card down‐converts the signals to th e IF and converts the analogue signal into a digital signal. This signal is forwarded to the Main Board, where digital filtering takes place. After the digital signal processing the signals comes back to the RF card, where the digital signal is converted into an analogue signal, is up‐converted and amplified. Finally, the signal is sent to the PA and combined with the uplink signal. After that the signals from all RF cards are combined at the crossband coupler and forwarded to the mobile port of the Node A system. The specific device gen erally will be professionally installed. Hereby the gain of the finally installed antenna(s), cable attenuation and antenna height will be defined site specific at the time of licensing with the appropriate FCC Bureau(s). The maximum permissible exposure limit is defined in 47 CFR 1.1310 (B). Limits for General Population / Uncontrolled Exposures Frequency Range (MHz) Power Density (mW/cm 2 ) 300 – 1500 f/1500 The NoteA operates in the frequency range of 450 – 470 MHz, so that the worst case Power Density Limit is 450/150 = 3 W/m 2 . The max measured conducted output power is: ‐ max composite output power based on one carrier (rated) per path: 7,08W (38.5dBm) The maximum permitted level is to be calculated using general equation: S = P*G/4πR 2 P = 20W; G = antenna‐cable attenuation to be defined (numeric gain); π = 3,1416 The min separation distance between the antenna and any human body is to be calculated (solving for R in cm) with the final actual antenna gain/cable attenuation where the limit of 3mW/cm 2 is kept. The antenna(s) used with device must be fixed‐mounted on permanent structures with a distance to any human body to comply with the RF Exposure limit.
Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-050-V01.00_XS5-AF4037W4 Page 1 of 42 Date of issue: 04.08.10 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: 01.03.11 Checked: M. Lehmann Head of the ECL Test dates: 04.08. – 01.03.11 Pages: 42 ECL-EMC Test Report No.: Equipment under test: AF 4037 XS5-AF4037W4 FCC ID: 2237E-AF4037W4 IC ID: FCC 47 CFR Part 90 Subpart K: 2011 Private Land Mobile Radio Service IC RSS-131: 2003 Zone Enhancers for the land Mobil Service Type of test: Measurement Procedures: 47 CFR Parts 2 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), 90 (Private Land Mobile), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: FCC ID: XS5-AF4037W4 IC ID: 2237E-AF4037W4 The test report shall not be reproduced except in full ANDREW Wireless Systems GmbH Manufacturer: Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 TEMPTON Service Plus GmbH Test Location: European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 (0) 911 59835 0 Fax: +49 (0) 911 59835 90 General: General: The purpose of this report is to show compliance to the FCC regulations for licensed devices operating under section 90 of the Code of Federal Regulations title 47. The purpose of this report is to show compliance to the FCC regulations for licensed devices operating under section 90 of the Code of Federal Regulations title 47. This report informs about the results of the RF tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. This report informs about the results of the RF tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. without the written approval of the testing laboratory. ECL-EMC-TR-11-050-V01.00_XS5-AF4037W4 Page 2 of 42 Test Report No.: FCC ID: XS5-AF4037W4 IC ID: 2237E-AF4037W4 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-050-V01.00_XS5-AF4037W4 Page 3 of 42 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 SYSTEM DIAGRAM OF EUT .........................................................................................................7 2.1.5 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................8 3.1 TEST ENVIRONMENT..........................................................................................................................8 3.2 TEST EQUIPMENT..............................................................................................................................8 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON) ........................................................................................................................9 5 RF POWER OUT: §90.205, §2.1046 ...................................................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................11 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................11 5.3.1.1 Analog.............................................................................................................................12 5.3.2 UPLINK....................................................................................................................................13 5.3.2.1 Analog.............................................................................................................................13 5.4 SUMMARY TEST RESULT...................................................................................................................13 6 OCCUPIED BANDWIDTH: §2.1049 ....................................................................................................14 6.1 LIMIT.............................................................................................................................…
Text truncated - open the document above for the full version.
EUT: AF4037 Test Setup: Andrew Test Setup: Tempton
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 9 | 455 MHz - 470 MHz | 630.00 mW | F3E | Amp |

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit)
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)