FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Andrew Wireless System/
  3. XS5-CAPM2343737

XS5-CAPM2343737Era Repeater for cellular systems

Andrew Wireless System
Era Repeater for cellular systems - FCC ID XS5-CAPM2343737 - Andrew Wireless System
Click to zoom

Application Details

Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
Dec 14, 2023
Application Purpose
Original Equipment
Date of Application
Dec 14, 2023
Equipment Note
Era Repeater for cellular systems
Frequency Range
3700.00000000 - 3980.00000000
Company
Andrew Wireless System
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit must be mounted by professional / specially trained fitter 1.1. MECHANICAL INSTALLATION 1.1.1. Health and Safety for Mechanical Installation 1.2. ELECTRICAL INSTALLATION 1.2.1. Health and Safety for Electrical Installation

Users Manual

CommScope ERA ® CAP M2 Installation Guide Release P/N M0203AH, DRAFT Rev C Dec 2023 DRAFT: CONFIDENTIAL Copyright Statement Copyright statement for DAS and Small Cell documents. Copyright © 2023 CommScope, All rights reserved. THIS DOCUMENT HAS BEEN DEVELOPED BY COMMSCOPE, AND IS INTENDED FOR THE USE OF ITS CUSTOMERS AND CUSTOMER SUPPORT PERSONNEL. THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR COMMSCOPE SALES REPRESENTATIVE FOR A COPY. DRAFT: CONFIDENTIAL CommScope ERA ® CAP M2 Installation Guide , Release P/N M0203AH, DRAFT Rev C2 Contents Copyright Statement...........................................................................................................................2 Chapter 1. Document Overview..........................................................................................................5 Document Revision History...................................................................................................................5 Document Cautions and Notes.............................................................................................................6 Abbreviations Used in this Guide..........................................................................................................6 Safely Working with ERA Hardware......................................................................................................7 Health and Safety Precautions........................................................................................................7 Property Damage Warnings............................................................................................................7 General Installation Safety Requirements...................................................................................... 8 Guard Against Damage from Electro-Static Discharge....................................................................8 Compliance..................................................................................................................................... 8 Equipment Symbols Used / Compliance.......................................................................................11 Maximum Output Power Levels....................................................................................................11 Required Antenna Distances.........................................................................................................12 Chapter 2. CAP M2 Overview............................................................................................................13 Connectors and LED for the CAP M2.................................................................................................. 13 CAP M2 Accessories and Options....................................................................................................... 16 Mounting Kits............................................................................................................................... 16 SFP+ Module Kits.......................................................................................................................... 17 OCTIS ™ Universal Lever Assembly Kits.........................................................................................17 OCTIS Universal Lever Assembly Instructions...............................................................................18 Chapter 3. Plan And Prepare For CAP M2 Installation........................................................................20 Maximum Number of CAP M2s Supported in an ERA System............................................................20 Determine the Power Consumption of the CAP M2...........................................................................20 Determine the CAP M2 Installation Site............................................................................................. 21 CAP M2 Dimensions......................................................................................................................21 CAP M2 Weights........................................................................................................................... 24 Recommended Tools and Material.....................................................................................................25 Unpack and Inspect the CAP M2 and Optional Accessories...............................................................25 Obtain the Required Materials........................................................................................................... 25 Chapter 4. Mount The CAP M2..........................................................................................................27 General Mounting Cautions................................................................................................................27 DRAFT: CONFIDENTIAL CommScope ERA ® CAP M2 Installation Guide , Release P/N M0203AH, DRAFT Rev C3 Wall Mount a CAP M2...................................................................................................................27 Mounting CAP M2 with a Wall Mounting Kit......................................................................................28 Mounting a CAP M2 with a Hybrid Fiber Splice Box Kit (optional)..................................................... 31 Prepare for CAP M2 Hybrid Fiber Splice Box Kit Installation.........................................................3…

Text truncated - open the document above for the full version.

Attestation Statements

Andrew Wireless Systems GmbH Industriering 10 86675 Buchdorf Tel: +49 9099 – 69 0 Fax: +49 9099 – 69 930 www.commscope.com Andrew Wireless Systems GmbH, Industriering 10, D-86675 Buchdorf Geschäftsführer: Dr. Thomas Kummetz, Alisdair Saunders Lamb More, Gillian Coleman Telefon: +49 90 99 69-0, Fax: +49 90 99 69-930, Internet: www.commscope.com Amtsgericht Augsburg, HRB No: 949, German Tax-No: 152/121/50468, VAT: DE127491606 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date 11/10/2023 Covered Equipment Attestation Letter FCC ID: XS5-CAPM2343737 Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Andrew Wireless Systems GmbH (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Andrew Wireless Systems GmbH (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: Era Repeater (DAS) for Cellular Systems If you have any questions, please feel free to contact me. Contact Person: Jiri Cecka Position in the company: Manager Quality & Grantee Contact Person Date: 11/10/2023 Signature of the applicant:

Attestation Statements

Andrew Wireless Systems GmbH Industriering 10 86675 Buchdorf Tel: +49 9099 – 69 0 Fax: +49 9099 – 69 930 www.commscope.com Andrew Wireless Systems GmbH, Industriering 10, D-86675 Buchdorf Geschäftsführer: Dr. Thomas Kummetz, Alisdair Saunders Lamb More, Gillian Coleman Telefon: +49 90 99 69-0, Fax: +49 90 99 69-930, Internet: www.commscope.com Amtsgericht Augsburg, HRB No: 949, German Tax-No: 152/121/50468, VAT: DE127491606 U.S. Agent Designation for Service of Process - Certification Attestation Letter November 11, 2023 PHOENIX TESTLAB GmbH Product Certification Department Koenigswinkel 10 32825 Blomberg, Germany ATTN.: Reviewing Engineer FCC ID: XS5-CAPM2343737 Applicant’s FRN: 0019152750 Per section 2.911(d)(7) of the FCC rules, Andrew Wireless System GmbH (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: CommScope Technologies LLC Physical U.S. Company Address: 2601 Telecom Parkway, Richardson, TX 75082 Agent name: Gerald Reynolds Agent Email Address: [email protected] FRN: 0033464595 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: Cecka Jiri Printed name: Gerald Reynolds Title: Manager Quality Title: Senior Quality Director Company Name: Andrew Wireless Systems Company Name: CommScope Technologies LLC Date: November 11, 2023 Date: November 11, 2023

Cover Letter(s)

Andrew Wireless Systems GmbH Industriering 10 86675 Buchdorf Tel: +49 9099 – 69 0 Fax: +49 9099 – 69 930 www.commscope.com Andrew Wireless Systems GmbH, Industriering 10, D-86675 Buchdorf Geschäftsführer: Dr. Thomas Kummetz, Alisdair Saunders Lamb More, Gillian Coleman Telefon: +49 90 99 69-0, Fax: +49 90 99 69-930, Internet: www.commscope.com Amtsgericht Augsburg, HRB No: 949, German Tax-No: 152/121/50468, VAT: DE127491606 PHOENIX TESTLAB GmbH Product Certification Department Koenigswinkel 10 32825 Blomberg, Germany Date 11/10/2023 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: XS5-CAPM2343737 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform PHOENIX TESTLAB GmbH to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☐ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☒ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☐ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Printed name: Cecka Jiri Title: Manager Quality Company Name: Andrew Wireless Systems GmbH Date: 11/10/2023

Cover Letter(s)

Andrew Wireless Systems GmbH Industriering 10 86675 Buchdorf Tel: +49 9099 – 69 0 Fax: +49 9099 – 69 930 www.commscope.com Andrew Wireless Systems GmbH, Industriering 10, D-86675 Buchdorf Geschäftsführer: Dr. Thomas Kummetz, Alisdair Saunders Lamb More, Gillian Coleman Telefon: +49 90 99 69-0, Fax: +49 90 99 69-930, Internet: www.commscope.com Amtsgericht Augsburg, HRB No: 949, German Tax-No: 152/121/50468, VAT: DE127491606 PHOENIX TESTLAB GmbH Product Certification Department Koenigswinkel 10 32825 Blomberg, Germany Date 11/10/2023 ATTN.: Reviewing Engineer FCC ID: XS5-CAPM2343737 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Sabrina Berghahn & Bernd Steiner from PHOENIX TESTLAB GmbH, to act as our agents in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Cecka Jiri Title: Manager Quality Company Name: Andrew Wireless Systems GmbH Date: 11/10/2023

Cover Letter(s)

Andrew Wireless Systems GmbH Industriering 10 86675 Buchdorf Tel: +49 9099 – 69 0 Fax: +49 9099 – 69 930 www.commscope.com Andrew Wireless Systems GmbH, Industriering 10, D-86675 Buchdorf Geschäftsführer: Dr. Thomas Kummetz, Alisdair Saunders Lamb More, Gillian Coleman Telefon: +49 90 99 69-0, Fax: +49 90 99 69-930, Internet: www.commscope.com Amtsgericht Augsburg, HRB No: 949, German Tax-No: 152/121/50468, VAT: DE127491606 Date 11/10/2023 WARNING LABELING ATTESTATION LETTER FCC ID: XS5-CAPM2343737 To whom it may concern, Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device (per KDB 935210 D02) Warning labelling information: For Industrial Signal Boosters WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Sincerely, Printed name: Cecka Jiri Title: Manager Quality Company Name: Andrew Wireless Systems Date: 11/10/2023

External Photos

CAP M2 34T/37T/37T External Photos Front Rear Bottom Top Left Right

ID Label/Location Info

Label CAP M2 34T/37T/37T F‐AC‐F1 Label CAP M2 34T/37T/37T F‐DC‐F1 Label Location 7677269-05 7845217-00 Label 7845217-00 Label 7677269-05 65mm 50mm

Internal Photos

Internal Photos CAP M2 34T/37T/37T (7856236-1003/-1004) BBC - Base Band Card 7846529-06 PCBA P4324 BBC P7 RM 37T Radio Module c-Band TDD RM 34T Radio Module DoD Band TDD RM 34T 7852700-00 PCBA P4489 RM M2 TDD 35LT-HT/35LT-HT RM 37T 7851882-01 P4479 POP. RM M2 TDD 35C/35C DPEM - Data & Power Entry Module DPEM 7843351-02 PCB P4375 RP5200 DPEM 2 Internal Photos CAP M2 34T/37T/37T (7856236-1003) - AC-PSU AC PSU Internal Photos CAP M2 34T/37T/37T (7856236-1004) - DC-PSU DC PSU

RF Exposure Info

The test results relate only to the tested item. The sample has been provided by the client. Without the written consent of Bureau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. Bureau Veritas Consumer Products Services Germany GmbH www.bureauveritas.de/cps Phone: +49 (0)40 – 740 41 – 0 Schwerin Wilhelm-Hennemann-Str. 8, 19061 Schwerin [email protected] Tuerkheim Businesspark A96, 86842 Tuerkheim [email protected] Managing Director: Sebastian Doose, Stefan Kischka VAT-No.: DE164793120 Reg.No.: Schwerin HRB 3564 Hamburg Oehleckerring 40, 22419 Hamburg [email protected] Nuremberg Thurn-und-Taxis-Str. 18, 90411 Nuremberg [email protected] RPRT-00XX-NU-V01 / TEMP-00XX-DEU-V01 Page 1 of 10 RF Exposure Assessment Report Reference: 2023-0313-MPE-TR-23-0019-V02 on Commscope Inc. ERA CAP M2 34T/37T/37T Medium Power Carrier Access Point FCC ID: XS5-CAPM2343737 according to: OET Bulletin 65 Edition 97-01: August 1997 Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Signature: Date of issue: 08.12.2023 Technical Reviewer: Version: 02 Report Reviewer: TEST REPORT REFERENCE: 2023-0313-MPE-TR-23-0019-V02 Page 2 of 10 Contents 1 Summary .................................................................................................................... 3 2 Administrative Data...................................................................................................... 4 2.1 Testing Laboratory ................................................................................................ 4 2.2 Applicant Data ...................................................................................................... 4 2.3 Manufacturer Data................................................................................................. 4 3 Test object Data .......................................................................................................... 5 4 Assessment ................................................................................................................. 6 4.1 Assessment method and subject of assessment ........................................................ 6 4.2 Exposure limits ..................................................................................................... 7 4.3 Formulas used for calculation .................................................................................. 7 4.4 Calculation ........................................................................................................... 8 Version History Version no. of report Changes to previous version 01 Initial version. 02 a) Editorial change of considerations regarding maximum output power in chapter 4.1. b) Text “Bold marked = worst case band of the radio technology“ in table of chatper 4.4.1 removed. c) Supplemental of measurements in the last line “ 5G MIMO 4*4“ in chapter 4.4.2. TEST REPORT REFERENCE: 2023-0313-MPE-TR-23-0019-V02 Page 3 of 10 1 Summary The RF-exposure assessment according to OET Bulletin 65 Edition 97-01: August 1997 shows, that the worst-case RF exposure values of the assessed radio technologies and bands are below the Limits for General Population/Uncontrolled Exposure: • Table 1 (B) of OET Bulletin 65 • Table 1 (II) to § 1.1310(E)(1) of 47 CFR Ch. I (10–1–21 Edition). COMMENTS: • Assessment limited to supported North American frequency bands • Prediction Distance R = 169 cm TEST REPORT REFERENCE: 2023-0313-MPE-TR-23-0019-V02 Page 4 of 10 2 Administrative Data 2.1 Testing Laboratory Company Name: Bureau Veritas Consumer Products Services Germany GmbH Address: Thurn-und-Taxis-Straße 18 90411 Nürnberg Germany 2.2 Applicant Data Company Name: Andrew Wireless Systems GmbH Address: Industriering 10 86675 Buchdorf Germany Contact Person: Daniel Schwab 2.3 Manufacturer Data Company Name: Andrew Wireless Systems GmbH Address: Industriering 10 86675 Buchdorf Germany Contact Person: Daniel Schwab TEST REPORT REFERENCE: 2023-0313-MPE-TR-23-0019-V02 Page 5 of 10 3 Test object Data Declared EUT data by the supplier Kind of Device product description The ERA product is a digital distribution system with focus on flexibility, easy installing, commissioning, and reliable operation. The system is designed in a way to satisfy all of today’s needs as well as unknown future standards and requirements. The ERA system comprises of two main parts. A base station interface (Master or Head End Unit) that takes RF signals as well as digital signals from the base stations, conditions the signals for the given application and assigns them to the coverage zones. The coverage side is built of one or more Remote Units. The “Remote Unit” (hereinafter referred to as “RU”) is connected via a 10GBASE SFP+ fiber optical link to the ERA Master Unit. This link gives a total RF bandwidth of up to 320 MHz. For higher bandwidth requirements up to 640 MHz, a secondary 10G link can be used in parallel. RF signals between Master Unit and Remote Units are sent digitally over the fiber optical link. At the receiver side these signals are converted back to analog and amplified up to appropriate transmit levels. Product name Medium Power Carrier Access Point Type ERA CAP M2 34T/37T/37T Hardware version 7856326-1004 Rev.: 00 Software version 1.6.0.109 Integrated transmitter Medium Power Carrier Access Point supported Radio technologies Band C 5G N77 Antenna none Supplied document(s) - TEST REPORT REFERENCE: 2023-0313-MPE-TR-23-0019-V02 Page 6 of 10 4 Assessment 4.1 Assessment method and subject of assessment Calculation of power density and comparison with reference levels for general public exposure. Applicability area and limitations: Power density can be calculated in far field region. Applied Standards: • IEEE Std C95.3-2021, D.4.2 Antennas – Main beam on-axis, general method for determining the power density at points in the radiating near-field and …

Text truncated - open the document above for the full version.

Test Report

The test results relates only to the tested item. The sample has been provided by the client. Without the written consent of Burau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. Bureau Veritas Consumer Products Services Germany GmbH www.bureauveritas.de/cps Tel.: +49 (0)40 – 740 41 – 0 Schwerin Wilhelm-Hennemann-Str. 8, 19061 Schwerin [email protected] Tuerkheim Businesspark A96, 86842 Tuerkheim [email protected] Managing Director: Sebastian Doose / Stefan Kischka VAT-No.: DE164793120 Reg.No.: Schwerin HRB 3564 Hamburg Oehleckerring 40, 22419 Hamburg [email protected] Nuremberg Thurn-und-Taxis-Str. 18, 90411 Nuremberg [email protected] RPRT-0168-NU-V01 / TEMP-0059-NU-V01 Page 1 of 103 Test report 2023-0313-EMC-TR-23-0200-V02 Designation: CAP M2 34T/37T/37T F-DC-F1 [34T] Manufacturer: Commscope Serial No(s): BGCMAD2321001 ID No. 7856326-1004 Rev: 00 FCC ID XS5-CAPM2343737 Test Specification(s): ANSI 63.26:2015 FCC Rules and Regulations as listed in 47 CFR, Part 20 and Part 27:2022-07-29 Test Plan: "Info_Blatt_CAP-M2_34T-37T-37T_FCC" from customer. Test Result: Passed Date of issue: 2023-12-08 Signature: Version: 02 Technical Reviewer: Date of delivery: 2023-08-28 Performance date: 2023-09-06 – Report Reviewer: 2023-11-14 EMC Test Report No.: 23-0200 EMC tests on Andrew CAP M2 34T/37T/37T F-DC-F1 [34T] The test results relate only to the tested item. The sample has been provided by the client. Without the written consent of Bureau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. 2023-0313-EMC-TR-23-0200-V02 RPRT-0168-NU-V01 / TEMP-0059-NU-V01 Page 2 of 103 Client: Commscope Andrew Wireless System GmbH Industriering 10 86675 Buchdorf Germany Test laboratory: Bureau Veritas Consumer Products Services Germany GmbH Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 40 74041 0 Test location: Bureau Veritas Consumer Products Services Germany GmbH Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Laboratory accreditation no: DAkkS D-PL-12024-06-04 BNETZA-CAB-19/21-20 FCC Designation Number: DE0023 FCC Test Firm Registration: 366481 Versions management: V 01.00 Initial release V 02.00 Chapter 4.7 “Frequency Stability” added with corresponding commentary; Antenna gain on page 23 corrected from 9 dBi to 15 dBi; In chapter 4.8.3 the two antenna ports corrected to “ANT1 and ANT3”; Overlapping calibration data taken into account in the tables on page 95. EMC Test Report No.: 23-0200 EMC tests on Andrew CAP M2 34T/37T/37T F-DC-F1 [34T] The test results relate only to the tested item. The sample has been provided by the client. Without the written consent of Bureau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. 2023-0313-EMC-TR-23-0200-V02 RPRT-0168-NU-V01 / TEMP-0059-NU-V01 Page 3 of 103 Table of Contents 1 APPLIED STANDARDS AND TEST SUMMARY .................................................................................................................4 1.1 CFR APPLIED STANDARDS .........................................................................................................................................4 1.2 FCC REFERENCE TABLE ...............................................................................................................................................5 1.3 MEASUREMENT SUMMARY .........................................................................................................................................6 2 ADMINISTRATIVE DATA ......................................................................................................................................................11 2.1 TESTING LABORATORY .............................................................................................................................................11 2.2 APPLICANT DATA .........................................................................................................................................................11 2.3 MANUFACTURER DATA ..............................................................................................................................................11 3 TEST OBJECT DATA ..............................................................................................................................................................12 3.1 GENERAL EUT DESCRIPTION ..................................................................................................................................12 3.2 EUT MAIN COMPONENTS ..........................................................................................................................................13 3.3 ANCILLARY EQUIPMENT ............................................................................................................................................13 3.4 AUXILIARY EQUIPMENT.............................................................................................................................................14 3.5 EUT SETUPS ...................................................................................................................................................................15 3.6 OPERATING MODES ....................................................................................................................................................16 3.7 PRODUCT LABELLING ................................................................................................................................................19 4 TEST RESULTS .......................................................................................................................................................................20 4.1 EFFECTIVE RADIATED POWER, MEAN OUTPUT POWER AND ZONE ENHANCER GAIN ......................20 4.2 PEAK TO AVERAGE RATIO ................................................................…

Text truncated - open the document above for the full version.

Test Report

The test results relates only to the tested item. The sample has been provided by the client. Without the written consent of Burau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. Bureau Veritas Consumer Products Services Germany GmbH www.bureauveritas.de/cps Tel.: +49 (0)40 – 740 41 – 0 Schwerin Wilhelm-Hennemann-Str. 8, 19061 Schwerin [email protected] Tuerkheim Businesspark A96, 86842 Tuerkheim [email protected] Managing Director: Sebastian Doose / Stefan Kischka VAT-No.: DE164793120 Reg.No.: Schwerin HRB 3564 Hamburg Oehleckerring 40, 22419 Hamburg [email protected] Nuremberg Thurn-und-Taxis-Str. 18, 90411 Nuremberg [email protected] RPRT-0168-NU-V01 / TEMP-0059-NU-V01 Page 1 of 202 Test report 2023-0313-EMC-TR-23-0199-V02 Designation: CAP M2 34T/37T/37T F-DC-F1 [37T] Manufacturer: Commscope Serial No(s): BGCMAD2321001 ID No. 7856326-1004 Rev: 00 FCC ID XS5-CAPM2343737 Test Specification(s): ANSI 63.26:2015 FCC Rules and Regulations as listed in 47 CFR, Part 20 and Part 27:2022-07-29 Test Plan: "Info_Blatt_CAP-M2_34T-37T-37T_FCC" from customer. Test Result: Passed Date of issue: 2023-1 2-08 Signature: Version: 02 Technical Reviewer: Date of delivery: 2023-0 8-28 Performance date: 2023-0 9-06 – Report Reviewer: 2023-12-06 EMC Test Report No.: 23-0199 EMC tests on Andrew CAP M2 34T/37T/37T F-DC-F1 [37T] The test results relate only to the tested item. The sample has been provided by the client. Without the written consent of Bureau Veritas Consumer Products Services Germany GmbH excerpts of this report shall not be reproduced. 2023-03…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jiri Cecka(Manager Quality)
[email protected]+420606620263Fax: +49-9099-69930

Technical Contact

Andrew Wireless SystemsDaniel Schwab
[email protected]+49 9099 69 448

Industriering 10 · Buchdorf · Germany

Test Firm

Bureau Veritas Consumer Products Services GermanyFlorian Mosandl
[email protected]+49 40 740 41 - 0

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
2273.70 GHz - 3.98 GHz95.5 WG7DAmp
Confidentiality
Long Term
Grant Notes
Output Power listed is the max calculated EIRP based on the conducted output power at each antenna terminal and a maximum antenna gain of 15 dBi without cable loss as defined by the Grantee. This filing has compliance demonstration information and test data for both SISO and 2x2 (34T and 37T) / 4x4 (37T) MIMO industrial booster system configurations. It is authorized to operate only as part of a distributed-antenna booster system. Users and professional installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, for satisfying RF exposure compliance. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of sect;1.1307(b) (3).

Other Applications from Andrew Wireless System

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1 - FCC ID XS5-H23437HP - Andrew Wireless System
XS5-H23437HP

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1

Apr 10, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2BDOD - Andrew Wireless System
XS5-RML2BDOD

ERA L2 Radio Module

Oct 25, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit) - FCC ID XS5-CAPL2CBAND - Andrew Wireless System
XS5-CAPL2CBAND

Era Repeater for cellular systems (DAS - Remote Unit)

Dec 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2B25 - Andrew Wireless System
XS5-RML2B25

ERA L2 Radio Module

Sep 28, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2B66 - Andrew Wireless System
XS5-RML2B66

ERA L2 Radio Module

Sep 26, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)