Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Optical Remote Unit ION™-M17HP/19P (M-cabinet) User's Manual M0145A0A User’s Manual for ION™-M17HP/19P (M-cab) Page 2 M0145A0A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 05-September-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. INTRODUCTION 13 2.1. PURPOSE 13 2.2. THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR) 13 3. FUNCTIONAL DESCRIPTION 15 3.1. GENERAL 15 3.2. COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT 16 3.2.1. Components Inside the Unit 16 3.2.2. Fan-Protection Kit 17 3.2.3. Accessories 17 4. COMMISSIONING 19 4.1. MECHANICAL INSTALLATION 19 4.1.1. General 19 4.1.2. Wall-Mounting Procedure 21 4.1.3. Pole-Mounting Procedure 22 4.1.4. Mounting of Fan Protection 24 4.2. ELECTRICAL INSTALLATION 25 4.2.1. General 25 4.2.2. Connections 26 4.2.3. Grounding 27 4.2.4. Power Connection 27 4.3. CONNECTION OF THE ANTENNA CABLES 28 4.4. OPTICAL FIBER CABLE CONNECTION RULES 29 4.4.1. Protective Plug 30 4.4.2. Protective-Tube Kit 32 4.5. COMMISSIONING 34 User’s Manual for ION™-M17HP/19P (M-cab) Page 4 M0145A0A.doc 5. ALARMS 37 5.1. BITE AND ALARMS 37 5.2. HANDLING OF ALARMS 37 5.3. ALARM STATUS 37 5.4. STATUS LED ALARMS 37 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 38 5.6. TROUBLESHOOTING 40 6. MAINTENANCE 41 6.1. GENERAL 41 6.2. REPLACING THE FAN UNIT 42 6.3. CLEANING THE HEAT SINK 44 7. APPENDIX 45 7.1. ILLUSTRATIONS 45 7.2. SPECIFICATIONS 46 7.2.1. Electrical Specifications 46 7.2.2. Mechanical Specifications 47 7.2.3. Environmental and Safety Specifications 48 7.3. SPARE PARTS 49 8. INDEX 51 Page 5 FIGURES AND TABLES figure 3-1 Configuration of an ION-M17HP/19P Remote Unit................................... 15 figure 3-2 Remote Unit, front side, fully RF equipped ............................................... 16 figure 3-3 Remote Unit, rear side, fully RF equipped ................................................ 16 figure 4-1 Wall mounting, (metric dimensions).......................................................... 21 figure 4-2 Pole-mounting kit...................................................................................... 22 figure 4-3 Pole mounting (metric dimensions) .......................................................... 23 figure 4-4 Mounting procedure for fan protection, (metric dimensions)..................... 24 figure 4-5 Connector flange of ION-M17HP/19P...................................................... 26 figure 4-6 Grounding bolt with loosened hex nut ...................................................... 27 figure 4-7 Grounding bolt, schematic view................................................................ 27 figure 4-8 AC mains plug .......................................................................................... 28 figure 4-9 Protective-plug assembly ......................................................................... 30 figure 4-10 Tube-kit installation................................................................................. 33 figure 5-1 Flange connector, 5 poles........................................................................ 38 figure 5-2 Flange connector, 7 poles........................................................................ 38 figure 5-3 Alarm inputs and outputs, standard .......................................................... 39 figure 7-1 Installation drawing................................................................................... 45 table 1-1 List of international contact addresses....................................................... 12 table 4-1 Specified torques ....................................................................................... 20 table 5-1 Status LED alarms..................................................................................... 38 User’s Manual for ION™-M17HP/19P (M-cab) Page 6 M0145A0A.doc For your notes: 1 General Page 7 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mo…
Text truncated - open the document above for the full version.
Installation instruction The Remote and the Master Unit has to be mounted by a professional/ special trained installer.
External Pictures
Label Location
RF Exposure Info / MPE Sample Calculation Model: ION‐M17HP/19P FCC‐ID: XS5‐IONM17HP19P The ION‐M17HP/19P is a fiber optic based RF repeater for wireless applications. An RF signal is converted to an optical signal by directly modulating a laser. There is no frequency conversion in this system. The optical signal is converted back to RF at the ION‐M remote unit, amplified and broadcast from an antenna or into a passive RF distribution system, such as radiating cable. The RF gain in the system is maintained at a constant level throughout the system via AGC and the user does not need to adjust the gain of the system. The user would inject an RF signal to produce the appropriate RF output power from the ION‐M remote unit. The receive path will always terminate in an RF source, such as a base station or repeater, and will not be directly connected to any antenna. The specific device generally will be professionally installed. Hereby the gain of the finally installed antenna(s), cable attenuation and antenna height will be defined site specific at the time of licensing with the appropriate FCC Bureau(s). The maximum permissible exposure limit is defined in 47 CFR 1.1310 (B). Limits for General Population / Uncontrolled Exposures Frequency Range (MHz) Power Density (mW/cm 2 ) 1550 – 100,000 1 The EUT operates in the 2 frequency bands: 2100 and 1900 MHz. The limit for Power Density is 1 mW/cm 2 . The max measured conducted output power is 46.0 dBm (40 W) at the 2100 MHz path and 43.0 dBm (20W) at the 1900 MHz path. The maximum permitted level is to be calculated using general equation: S = P*G/4πR 2 P = 40W; G = antenna‐cable attenuation to be defined (numeric gain); π = 3,1416 The min separation distance between the antenna and any human body is to be calculated (solving for R in cm) with the final actual antenna gain/cable attenuation where the limit of 1mW/cm 2 is kept. Example: For f=1930MHz (1 mW/cm 2 and P=46 dBm) and a gain = 9 dBi the calculated distance is R = 1.586 m. The antenna(s) used with device must be fixed‐mounted on permanent structures with a distance to any human body to comply with the RF Exposure limit.
Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-208-V02.00 Page 1 of 36 Date of issue: 10.10.11 Signature: Issue-No.: 02 Author: T. Zahlmann Test engineer Date of delivery: Checked: M. Lehmann Head of ECL Test dates: 05.04 – 05.09.11 Pages: 36 ECL-EMC Test Report No.: 11-208 Equipment under test: ION-M17HP/19P 1700MHz Path FCC ID: XS5-XS5-IONM17HP19P IC ID: 2237E-IONM17HP19P Type of test: FCC 47 CFR Part 27 Subpart C: 2011 Miscellaneous Wireless Communication Services IC RSS-131:2003 Zone Enhancers for the Land Mobile Service Measurement Procedures: 47 CFR Parts 2 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), Part 27:2011 (Miscellaneous Wireless Communication Services), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: 11-208 FCC ID: XS5-IONM17HP19P IC ID: 2237E-IONM17HP19P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-208-V02.00 Page 2 of 36 Manufacturer: ANDREW Wireless Systems GmbH Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: TEMPTON Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 (0) 911 59835 0 Fax: +49 (0) 911 59835 90 General: The purpose of this report is to show compliance to the FCC regulations for devices operating under Part N 22,N°27 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. Test Report No.: 11-208 FCC ID: XS5-IONM17HP19P IC ID: 2237E-IONM17HP19P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-208-V02.00 Page 3 of 36 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................8 3.1 TEST ENVIRONMENT..........................................................................................................................8 3.2 TEST EQUIPMENT..............................................................................................................................8 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON SERVICE PLUS GMBH) .................................................................................9 5 RF POWER OUT: §27.50, §2.1046 .....................................................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................11 5.3.1.1 CDMA .............................................................................................................................12 5.3.1.2 W-CDMA.........................................................................................................................12 5.3.1.3 LTE .................................................................................................................................13 5.3.2 UPLINK....................................................................................................................................13 5.4 SUMMARY TEST RESULT...................................................................................................................13 6 OCCUPIED BANDWIDTH: §2.1049 ....................................................................................................14 6.1 LIMIT...............................................................................................................................................14 6.2 TEST METHOD.................................................................................................................................14 6.3 TEST RESULTS................................................................................................................................14 6.3…
Text truncated - open the document above for the full version.
Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-209-V01.00 Page 1 of 44 Date of issue: 15.09.11 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: Checked: Th. Vogel Deputy head of the EMC Test dates: 05.04. – 05.09.11 Pages: 44 ECL-EMC Test Report No.: 11-209 Equipment under test: ION-M17HP/19P 1900MHz Path FCC ID: XS5-IONM17HP19P IC ID: 2237E-IONM17HP19P Type of test: FCC 47 CFR Part 24 Subpart E: 2011 Broadband PCS IC RSS-131:2003 Zone Enhancers for the Land Mobile Service Measurement Procedures: 47 CFR Parts 2: 2011(Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), 24 (Broadband PCS), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: 11-209 FCC ID: XS5- IONM17HP19P IC ID: 2237E- IONM17HP19P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-209-V01.00 Page 2 of 44 Manufacturer: ANDREW Wireless Systems GmbH Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: HERBERG Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 0911 59835 23 Fax: +49 0911 59835 90 General: The purpose of this report is to show compliance to the FCC regulations for unlicensed devices operating under section 15.249 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. Test Report No.: 11-209 FCC ID: XS5- IONM17HP19P IC ID: 2237E- IONM17HP19P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-209-V01.00 Page 3 of 44 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................8 3.1 TEST ENVIRONMENT..........................................................................................................................8 3.2 TEST EQUIPMENT..............................................................................................................................8 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON SERVICE PLUS GMBH) .................................................................................9 5 RF POWER OUT: §24.232, §2.1046 ...................................................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................12 5.3.1.1 GSM................................................................................................................................13 5.3.1.2 GSM-EDGE ....................................................................................................................13 5.3.1.3 CDMA .............................................................................................................................14 5.3.1.4 W-CDMA.........................................................................................................................14 5.3.1.5 LTE .................................................................................................................................15 5.3.2 UPLINK....................................................................................................................................16 5.4 SUMMARY TEST RESULT...................................................................................................................16 6 OCCUPIED BANDWIDTH: §2.1049 ....................................................................................................17 6.1 LIMIT...............................................................................................................................................17 6.2 TEST METHOD.........................................................…
Text truncated - open the document above for the full version.
Test setup Figure 1. EUT ION-M17HP/19P Figure 2. Measurement Equipment
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 27 | 2.11 GHz - 2.15 GHz | 40 W | NOTE 2 | Amp |

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit)
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module
Equipment Class