Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Nov 15, 2011
Application Purpose
Original Equipment
Date of Application
Nov 15, 2011
Equipment Note
ION-M7P Repeater
Frequency Range
746.00000000 - 757.00000000
Company
Andrew Wireless System
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗

External Photos

↗
↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗
↗
↗
↗
↗

Internal Photos

↗
↗
↗
↗
↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Optical Remote Unit ION™-M7P (M-cabinet) Manual MF0143A8A Manual for ION™-M7P Page 2 MF0143A8A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. FUNCTIONAL DESCRIPTION 13 2.1. PURPOSE 13 2.2. THE ION-M7P (INTELLIGENT OPTICAL NETWORK; MMR) 13 2.3. COMPONENTS OF THE ION-M7P REMOTE UNIT 14 2.3.1. Fan-Protection Kit 14 2.3.2. Accessories 14 3. COMMISSIONING 15 3.1. MECHANICAL INSTALLATION 15 3.1.1. General 15 3.1.2. Wall-Mounting Procedure 16 3.1.3. Pole-Mounting Procedure 17 3.1.4. Mounting of Fan Protection 19 3.2. ELECTRICAL INSTALLATION 20 3.2.1. General 20 3.2.2. Connections 21 3.2.3. Grounding 22 3.3. CONNECTION OF THE ANTENNA CABLES 23 3.4. POWER CONNECTION 24 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 25 3.5.1. Protective Plug 27 3.5.2. Protective-Tube Kit 29 3.6. COMMISSIONING 31 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 Manual for ION™-M7P Page 4 MF0143A8A.doc 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. SPECIFICATIONS 43 6.2.1. Electrical Specifications 43 6.2.2. Mechanical Specifications 43 6.2.3. Environmental and Safety Specifications 43 6.3. SPARE PARTS 44 7. INDEX 45 Page 5 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M7P .................................................................. 21 figure 3-6 RS485 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 DC mains plug ........................................................................................ 24 figure 3-11 Protective-plug assembly ....................................................................... 27 figure 3-12 Tube-kit installation................................................................................. 30 figure 4-1 Flange connector, 5 poles........................................................................ 36 figure 4-2 Flange connector, 7 poles........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 12 table 3-1 RS485 connector, PIN assignment............................................................ 22 table 4-1 Status LED alarms..................................................................................... 35 Manual for ION™-M7P Page 6 MF0143A8A.doc For your notes: 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed…

Text truncated - open the document above for the full version.

Users Manual

Optical Remote Unit ION™-M7P (M-cabinet) Manual MF0143A8A Manual for ION™-M7P Page 2 MF0143A8A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. FUNCTIONAL DESCRIPTION 13 2.1. PURPOSE 13 2.2. THE ION-M7P (INTELLIGENT OPTICAL NETWORK; MMR) 13 2.3. COMPONENTS OF THE ION-M7P REMOTE UNIT 14 2.3.1. Fan-Protection Kit 14 2.3.2. Accessories 14 3. COMMISSIONING 15 3.1. MECHANICAL INSTALLATION 15 3.1.1. General 15 3.1.2. Wall-Mounting Procedure 16 3.1.3. Pole-Mounting Procedure 17 3.1.4. Mounting of Fan Protection 19 3.2. ELECTRICAL INSTALLATION 20 3.2.1. General 20 3.2.2. Connections 21 3.2.3. Grounding 22 3.3. CONNECTION OF THE ANTENNA CABLES 23 3.4. POWER CONNECTION 24 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 25 3.5.1. Protective Plug 27 3.5.2. Protective-Tube Kit 29 3.6. COMMISSIONING 31 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 Manual for ION™-M7P Page 4 MF0143A8A.doc 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. SPECIFICATIONS 43 6.2.1. Electrical Specifications 43 6.2.2. Mechanical Specifications 43 6.2.3. Environmental and Safety Specifications 43 6.3. SPARE PARTS 44 7. INDEX 45 Page 5 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M7P .................................................................. 21 figure 3-6 RS485 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 DC mains plug ........................................................................................ 24 figure 3-11 Protective-plug assembly ....................................................................... 27 figure 3-12 Tube-kit installation................................................................................. 30 figure 4-1 Flange connector, 5 poles........................................................................ 36 figure 4-2 Flange connector, 7 poles........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 12 table 3-1 RS485 connector, PIN assignment............................................................ 22 table 4-1 Status LED alarms..................................................................................... 35 Manual for ION™-M7P Page 6 MF0143A8A.doc For your notes: 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed…

Text truncated - open the document above for the full version.

Users Manual

Optical Remote Unit ION™-M7P (M-cabinet) Manual MF0143A8A Manual for ION™-M7P Page 2 MF0143A8A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. FUNCTIONAL DESCRIPTION 13 2.1. PURPOSE 13 2.2. THE ION-M7P (INTELLIGENT OPTICAL NETWORK; MMR) 13 2.3. COMPONENTS OF THE ION-M7P REMOTE UNIT 14 2.3.1. Fan-Protection Kit 14 2.3.2. Accessories 14 3. COMMISSIONING 15 3.1. MECHANICAL INSTALLATION 15 3.1.1. General 15 3.1.2. Wall-Mounting Procedure 16 3.1.3. Pole-Mounting Procedure 17 3.1.4. Mounting of Fan Protection 19 3.2. ELECTRICAL INSTALLATION 20 3.2.1. General 20 3.2.2. Connections 21 3.2.3. Grounding 22 3.3. CONNECTION OF THE ANTENNA CABLES 23 3.4. POWER CONNECTION 24 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 25 3.5.1. Protective Plug 27 3.5.2. Protective-Tube Kit 29 3.6. COMMISSIONING 31 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 Manual for ION™-M7P Page 4 MF0143A8A.doc 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. SPECIFICATIONS 43 6.2.1. Electrical Specifications 43 6.2.2. Mechanical Specifications 43 6.2.3. Environmental and Safety Specifications 43 6.3. SPARE PARTS 44 7. INDEX 45 Page 5 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M7P .................................................................. 21 figure 3-6 RS485 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 DC mains plug ........................................................................................ 24 figure 3-11 Protective-plug assembly ....................................................................... 27 figure 3-12 Tube-kit installation................................................................................. 30 figure 4-1 Flange connector, 5 poles........................................................................ 36 figure 4-2 Flange connector, 7 poles........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 12 table 3-1 RS485 connector, PIN assignment............................................................ 22 table 4-1 Status LED alarms..................................................................................... 35 Manual for ION™-M7P Page 6 MF0143A8A.doc For your notes: 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed…

Text truncated - open the document above for the full version.

Users Manual

Optical Remote Unit ION™-M7P (M-cabinet) Manual MF0143A8A Manual for ION™-M7P Page 2 MF0143A8A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. FUNCTIONAL DESCRIPTION 13 2.1. PURPOSE 13 2.2. THE ION-M7P (INTELLIGENT OPTICAL NETWORK; MMR) 13 2.3. COMPONENTS OF THE ION-M7P REMOTE UNIT 14 2.3.1. Fan-Protection Kit 14 2.3.2. Accessories 14 3. COMMISSIONING 15 3.1. MECHANICAL INSTALLATION 15 3.1.1. General 15 3.1.2. Wall-Mounting Procedure 16 3.1.3. Pole-Mounting Procedure 17 3.1.4. Mounting of Fan Protection 19 3.2. ELECTRICAL INSTALLATION 20 3.2.1. General 20 3.2.2. Connections 21 3.2.3. Grounding 22 3.3. CONNECTION OF THE ANTENNA CABLES 23 3.4. POWER CONNECTION 24 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 25 3.5.1. Protective Plug 27 3.5.2. Protective-Tube Kit 29 3.6. COMMISSIONING 31 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 Manual for ION™-M7P Page 4 MF0143A8A.doc 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. SPECIFICATIONS 43 6.2.1. Electrical Specifications 43 6.2.2. Mechanical Specifications 43 6.2.3. Environmental and Safety Specifications 43 6.3. SPARE PARTS 44 7. INDEX 45 Page 5 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M7P .................................................................. 21 figure 3-6 RS485 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 DC mains plug ........................................................................................ 24 figure 3-11 Protective-plug assembly ....................................................................... 27 figure 3-12 Tube-kit installation................................................................................. 30 figure 4-1 Flange connector, 5 poles........................................................................ 36 figure 4-2 Flange connector, 7 poles........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 12 table 3-1 RS485 connector, PIN assignment............................................................ 22 table 4-1 Status LED alarms..................................................................................... 35 Manual for ION™-M7P Page 6 MF0143A8A.doc For your notes: 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed…

Text truncated - open the document above for the full version.

Users Manual

Optical Remote Unit ION™-M7P (M-cabinet) Manual MF0143A8A Manual for ION™-M7P Page 2 MF0143A8A.doc © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. FUNCTIONAL DESCRIPTION 13 2.1. PURPOSE 13 2.2. THE ION-M7P (INTELLIGENT OPTICAL NETWORK; MMR) 13 2.3. COMPONENTS OF THE ION-M7P REMOTE UNIT 14 2.3.1. Fan-Protection Kit 14 2.3.2. Accessories 14 3. COMMISSIONING 15 3.1. MECHANICAL INSTALLATION 15 3.1.1. General 15 3.1.2. Wall-Mounting Procedure 16 3.1.3. Pole-Mounting Procedure 17 3.1.4. Mounting of Fan Protection 19 3.2. ELECTRICAL INSTALLATION 20 3.2.1. General 20 3.2.2. Connections 21 3.2.3. Grounding 22 3.3. CONNECTION OF THE ANTENNA CABLES 23 3.4. POWER CONNECTION 24 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 25 3.5.1. Protective Plug 27 3.5.2. Protective-Tube Kit 29 3.6. COMMISSIONING 31 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 Manual for ION™-M7P Page 4 MF0143A8A.doc 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. SPECIFICATIONS 43 6.2.1. Electrical Specifications 43 6.2.2. Mechanical Specifications 43 6.2.3. Environmental and Safety Specifications 43 6.3. SPARE PARTS 44 7. INDEX 45 Page 5 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M7P .................................................................. 21 figure 3-6 RS485 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 DC mains plug ........................................................................................ 24 figure 3-11 Protective-plug assembly ....................................................................... 27 figure 3-12 Tube-kit installation................................................................................. 30 figure 4-1 Flange connector, 5 poles........................................................................ 36 figure 4-2 Flange connector, 7 poles........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 12 table 3-1 RS485 connector, PIN assignment............................................................ 22 table 4-1 Status LED alarms..................................................................................... 35 Manual for ION™-M7P Page 6 MF0143A8A.doc For your notes: 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jiri Cecka(Manager Quality)
[email protected]+420606620263Fax: +49-9099-69930

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
227746 MHz - 757 MHz20 WG7DAmp
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a maximum gain of 12 dBi. RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3). This device must be professionally installed. EUT connected to Master Unit.

Other Applications from Andrew Wireless System

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1 - FCC ID XS5-H23437HP - Andrew Wireless System
XS5-H23437HP

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1

Apr 10, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems - FCC ID XS5-CAPM2343737 - Andrew Wireless System
XS5-CAPM2343737

Era Repeater for cellular systems

Dec 14, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2BDOD - Andrew Wireless System
XS5-RML2BDOD

ERA L2 Radio Module

Oct 25, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit) - FCC ID XS5-CAPL2CBAND - Andrew Wireless System
XS5-CAPL2CBAND

Era Repeater for cellular systems (DAS - Remote Unit)

Dec 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)