XS5-M717PION-M Remote Unit for cellular systems

Andrew Wireless System
ION-M Remote Unit for cellular systems - FCC ID XS5-M717P - Andrew Wireless System
Click to zoom

Application Details

Equipment Class
AMP - Amplifier
Date of Grant
May 30, 2012
Application Purpose
Original Equipment
Date of Application
May 30, 2012
Equipment Note
ION-M Remote Unit for cellular systems
Frequency Range
2110.00000000 - 2155.00000000
Company
Andrew Wireless System
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗
↗
↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

RF Exposure Info

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. General Read the health and safety warnings in section 1.3. 1. Do not ins tall the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to pow er dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm 2 ). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Tallow-drop screws Hex nuts Spacing bolts PG (plastic) PG (aluminium) Thread M 4 M 8 M 4 M 8 PG 13.5 PG 29 Specified torques 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table Specified torques  Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in section 1.3. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property dam age can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 inch opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 1.3. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becom ing familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all th e warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well a…

Text truncated - open the document above for the full version.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. General Read the health and safety warnings in section 1.3. 1. Do not ins tall the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to pow er dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm 2 ). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Tallow-drop screws Hex nuts Spacing bolts PG (plastic) PG (aluminium) Thread M 4 M 8 M 4 M 8 PG 13.5 PG 29 Specified torques 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table Specified torques  Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in section 1.3. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property dam age can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 inch opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 1.3. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becom ing familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all th e warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well a…

Text truncated - open the document above for the full version.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. General Read the health and safety warnings in section 1.3. 1. Do not ins tall the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to pow er dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm 2 ). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Tallow-drop screws Hex nuts Spacing bolts PG (plastic) PG (aluminium) Thread M 4 M 8 M 4 M 8 PG 13.5 PG 29 Specified torques 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table Specified torques  Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in section 1.3. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property dam age can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 inch opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 1.3. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becom ing familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all th e warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well a…

Text truncated - open the document above for the full version.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. General Read the health and safety warnings in section 1.3. 1. Do not ins tall the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to pow er dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm 2 ). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Tallow-drop screws Hex nuts Spacing bolts PG (plastic) PG (aluminium) Thread M 4 M 8 M 4 M 8 PG 13.5 PG 29 Specified torques 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table Specified torques  Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in section 1.3. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property dam age can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against over-voltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is highly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an over-current limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 inch opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. Use a voltage limiting device for unstabilized electric networks that frequently generate spikes. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 1.3. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becom ing familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all th e warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well a…

Text truncated - open the document above for the full version.

Users Manual

Optical Remote Unit ION™-M7P/17P & Subassemblies (M-cabinet) Manual MF0145A7A Manual for ION™-M7P/17P (M-cab) & Subassemblies Page 2 MF0145A7A_uc_FCC_modif.doc © Copyright 2012 CommScope, Inc. All rights reserved. CommScope Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet CommScope Solutions accepts no liability for any omissions or faults. CommScope Solutions reserves the right to change all hardware and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 10-May-2012 Page 3 TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT COMMSCOPE SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. INTRODUCTION 14 2.1. PURPOSE 14 2.2. THE ION-M7P/17P (INTELLIGENT OPTICAL NETWORK; MMR) 14 3. FUNCTIONAL DESCRIPTION 16 3.1. COMPONENTS OF THE ION-M7P/17P REMOTE UNIT 16 3.1.1. Fan-Protection Kit 16 3.1.2. Accessories 16 4. COMMISSIONING 17 4.1. MECHANICAL INSTALLATION 17 4.1.1. General 17 4.1.2. Wall-Mounting Procedure 19 4.1.3. Pole-Mounting Procedure 20 4.1.4. Mounting of Fan Protection 22 4.2. ELECTRICAL INSTALLATION 23 4.2.1. General 23 4.2.2. Connections 24 4.2.3. Grounding 25 4.2.4. Power Connection 25 4.3. CONNECTION OF THE ANTENNA CABLES 26 4.4. OPTICAL FIBER CABLE CONNECTION RULES 27 4.4.1. Protective Plug 28 4.4.2. Protective-Tube Kit 30 4.5. COMMISSIONING 32 5. ALARMS 35 5.1. BITE AND ALARMS 35 5.2. HANDLING OF ALARMS 35 Manual for ION™-M7P/17P (M-cab) & Subassemblies Page 4 MF0145A7A_uc_FCC_modif.doc 5.3. ALARM STATUS 35 5.4. STATUS LED ALARMS 35 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 5.6. TROUBLESHOOTING 38 6. MAINTENANCE 39 6.1. GENERAL 39 6.2. REPLACING THE FAN UNIT 40 6.3. CLEANING THE HEAT SINK 42 7. APPENDIX 43 7.1. ILLUSTRATIONS 43 7.2. SPECIFICATIONS 44 7.2.1. Electrical Specifications 44 7.2.2. Mechanical Specifications 44 7.2.3. Environmental and Safety Specifications 44 7.3. SPARE PARTS 45 8. INDEX 46 Page 5 FIGURES AND TABLES figure 4-1 Wall mounting, (metric dimensions).......................................................... 19 figure 4-2 Pole-mounting kit...................................................................................... 20 figure 4-3 Pole mounting (metric dimensions) .......................................................... 21 figure 4-4 Mounting procedure for fan protection, (metric dimensions)..................... 22 figure 4-5 Connector flange of ION-M7P/17P........................................................... 24 figure 4-6 Grounding bolt with loosened hex nut ...................................................... 25 figure 4-7 Grounding bolt, schematic view................................................................ 25 figure 4-8 AC mains plug .......................................................................................... 26 figure 4-9 Protective-plug assembly ......................................................................... 28 figure 4-10 Tube-kit installation................................................................................. 31 figure 5-1 Flange connector, 5 poles........................................................................ 36 figure 5-2 Flange connector, 7 poles........................................................................ 36 figure 5-3 Alarm inputs and outputs, standard .......................................................... 37 figure 7-1 Installation drawing................................................................................... 43 table 1-1 List of international contact addresses....................................................... 13 table 4-1 Specified torques ....................................................................................... 18 table 5-1 Status LED alarms..................................................................................... 36 Manual for ION™-M7P/17P (M-cab) & Subassemblies Page 6 MF0145A7A_uc_FCC_modif.doc For your notes: Manual for ION™-M7P/17P (M-cab) & Subassemblies Page 7 MF0145A7A_uc_FCC_modif.doc 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP 3 rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PDU Power Distribution Unit PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex Manual for …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jiri Cecka(Manager Quality)
[email protected]+420606620263Fax: +49-9099-69930

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
4272.11 GHz - 2.15 GHz20 WG7DAmp
Confidentiality
Long Term
Grant Notes
Antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a maximum gain of 19 dBi. Operating is limited to a maximum antenna hight of 10m above ground per 27.50(d)(2). RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3). This device must be professionally installed. Part of booster system connected to Master Unit.

Other Applications from Andrew Wireless System

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1 - FCC ID XS5-H23437HP - Andrew Wireless System
XS5-H23437HP

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1

Apr 10, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems - FCC ID XS5-CAPM2343737 - Andrew Wireless System
XS5-CAPM2343737

Era Repeater for cellular systems

Dec 14, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2BDOD - Andrew Wireless System
XS5-RML2BDOD

ERA L2 Radio Module

Oct 25, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit) - FCC ID XS5-CAPL2CBAND - Andrew Wireless System
XS5-CAPL2CBAND

Era Repeater for cellular systems (DAS - Remote Unit)

Dec 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2B25 - Andrew Wireless System
XS5-RML2B25

ERA L2 Radio Module

Sep 28, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)