FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Andrew Wireless System/
  3. XS5-ML7851719P

XS5-ML7851719PION M remote unit for cellular networks

Andrew Wireless System
ION M remote unit for cellular networks - FCC ID XS5-ML7851719P - Andrew Wireless System
Click to zoom

Application Details

Equipment Class
AMP - Amplifier
Date of Grant
Jun 09, 2011
Application Purpose
Original Equipment
Date of Application
Jun 09, 2011
Equipment Note
ION M remote unit for cellular networks
Frequency Range
2110.00000000 - 2155.00000000
Company
Andrew Wireless System
Country
Germany

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

Label location

Internal Photos

Internal Pictures

RF Exposure Info

RF Exposure Info / MPE Sample Calculation Model: ION‐M7P/85P/17P/19P FCC‐ID: XS5‐ML7851719P The ION‐M7P/85P/17P/19P is a fiber optic based RF repeater for wireless applications. An RF signal is converted to an optical signal by directly modulating a laser. There is no frequency conversion in this system. The optical signal is converted back to RF at the ION‐M remote unit, amplified and br oadcast from an antenna or into a passive RF distribution system, such as radiating cable. The RF gain in the system is maintained at a constant level throughout the system via AGC and the user does not need to adjust the gain of the system. The user would inject an RF signal to produce the appropriate RF output power from the ION‐M remote unit. The receive path will always terminate in an RF source, such as a base station or repeater, and will not be directly connected to any antenna. The specific device generally will be professionally installed. Hereby the gain of the finally installed antenna(s), cable attenuation and antenna height will be defined site specific at the time of licensing with the appropriate FCC Bureau(s). The maximum permissible exposure limit is defined in 47 CFR 1.1310 (B). Limits for General Population / Uncontrolled Exposures Frequency Range (MHz) Power Density (mW/cm 2 ) 300 – 1500 f/1500 The EUT operates in the 4 frequency bands: 700, 850, 1900 and 2100 MHz. The lowest limit for Power Density is at the lowest frequency in the 700MHz band. At 728MHz the Power Density Limit is 0,485 mW/cm 2 . The max measured conducted output power is: ‐ max composite output power based on one carrier (rated) per path: 21,73W (43,37dBm) The maximum permitted level is to be calculated using general equation: S = P*G/4πR 2 P = 20W; G = antenna‐cable attenuation to be defined (numeric gain); π = 3,1416 The min separation distance between the antenna and any human body is to be calculated (solving for R in cm) with the final actual antenna gain/cable attenuation where the limit of 0,485mW/cm 2 is kept. The antenna(s) used with device must be fixed‐mounted on permanent structures with a distance to any human body to comply with the RF Exposure limit.

Test Report

Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-093-V01.00 Page 1 of 33 Date of issue: 26.04.11 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: 01.04.11 Checked: M. Lehmann Head of ECL Test dates: 1.04 – 05.04.11 Pages: 33 ECL-EMC Test Report No.: 11-093 Equipment under test: ION-M7P/85P/17P/19P 700MHz Path XS5-ML7851719P FCC ID: 2237E-ML7851719P IC ID: FCC 47 CFR Part 27 Subpart H, F:2011 Miscellaneous Wireless Communication Services IC RSS-131:2003 Zone Enhancers for the Land Mobile Service Type of test: Measurement Procedures: 47 CFR Parts 2:2011 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), Part 27:2009 (Miscellaneous Wireless Communication Services), ANSI/TIA-603-C:2004, Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN:2007 General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full ANDREW Wireless Systems GmbH Manufacturer: Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: TEMPTON Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 (0) 911 59835 0 Fax: +49 (0) 911 59835 90 General: General: The purpose of this report is to show compliance to the FCC regulations for devices operating under Part 27 of the Code of Federal Regulations title 47. The purpose of this report is to show compliance to the FCC regulations for devices operating under Part 27 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. without the written approval of the testing laboratory. ECL-EMC-TR-11-093-V01.00 Page 2 of 33 Test Report No.: FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-093-V01.00 Page 3 of 33 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................8 3.1 TEST ENVIRONMENT..........................................................................................................................8 3.2 TEST EQUIPMENT..............................................................................................................................8 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON) ........................................................................................................................9 5 RF POWER OUT: §27.50, §2.1046; RSS-131, RSS-GEN ..................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................11 5.3.1.1 LTE 728 – 746MHz,........................................................................................................12 5.3.1.2 LTE 746 – 757MHz,........................................................................................................12 5.3.2 UPLINK....................................................................................................................................13 5.4 SUMMARY TEST RESULT...................................................................................................................13 6 OCCUPIED BANDWIDTH: §90.210, §2.1049; RSS-GEN...................................................................14 6.1 LIMIT...............................................................................................................................................14 6.2 TEST METHOD.....................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-094-V01.00 Page 1 of 41 Date of issue: 26.04.11 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: Checked: M. Lehmann Head of ECL Test dates: 1.04 – 05.04.11 Pages: 41 ECL-EMC Test Report No.: 11-094 Equipment under test: ION-M7P/85P/17P/19P 850MHz Path XS5-ML7851719P FCC ID: IC ID: 2237E-ML7851719P Type of test: FCC 47 CFR Part 22 Subpart H:2011 Cellular Radiotelephone Service RSS-Gen:2007, RSS-131:2005 Cellular Telephones Employing New Technologies Operating in the Bands 824-849 MHz and 869-894 MHz Measurement Procedures: 47 CFR Parts 2:2009 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), Part 22:2009 (PUBLIC MOBILE SERVICES), ANSI/TIA-603-C:2004, Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN:2007 General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: 11-094 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full ANDREW Wireless Systems GmbH Manufacturer: Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: TEMPTON Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 (0) 911 59835 0 Fax: +49 (0) 911 59835 90 General: General: The purpose of this report is to show compliance to the FCC regulations for devices operating under Part N 22,N°27 of the Code of Federal Regulations title 47. The purpose of this report is to show compliance to the FCC regulations for devices operating under Part N 22,N°27 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. without the written approval of the testing laboratory. ECL-EMC-TR-11-094-V01.00 Page 2 of 41 Test Report No.: 11-094 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-094-V01.00 Page 3 of 41 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................8 3.1 TEST ENVIRONMENT..........................................................................................................................8 3.2 TEST EQUIPMENT..............................................................................................................................8 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON) ........................................................................................................................9 5 RF POWER OUT: §22.913, §2.1046; RSS-131, RSS-GEN ................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................12 5.3.1.1 GSM................................................................................................................................13 5.3.1.2 EDGE..............................................................................................................................13 5.3.1.3 CDMA .............................................................................................................................14 5.3.1.4 W-CDMA.........................................................................................................................14 5.3.1.5 LTE .................................................................................................................................15 5.3.2 UPLINK....................................................................................................................................15 5.4 SUMMARY TEST RESULT....................................…

Text truncated - open the document above for the full version.

Test Report

Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-095-V01.00 Page 1 of 33 Date of issue: 26.04.11 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: Checked: Head of ECL M. Lehmann Test dates: 05.04.11 1.04 – Pages: 33 ECL-EMC Test Report No.: 11-095 Equipment under test: ION-M7P/85P/17P/19P 1700MHz Path XS5-ML7851719P FCC ID: 2237E-ML7851719P IC ID: FCC 47 CFR Part 27 Subpart C: 2011 Miscellaneous Wireless Communication Services IC RSS-139:2009 Advanced Wireless Services Equipment Operating in the Bands 1710-1755 MHz and 2110-2155 MHz Type of test: Measurement Procedures: 47 CFR Parts 2 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), Part 27:2011 (Miscellaneous Wireless Communication Services), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Test Report No.: 11-094 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P ANDREW Wireless Systems GmbH Manufacturer: Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: TEMPTON Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 (0) 911 59835 0 Fax: +49 (0) 911 59835 90 General: General: The purpose of this report is to show compliance to the FCC regulations for devices operating under Part N 22,N°27 of the Code of Federal Regulations title 47. The purpose of this report is to show compliance to the FCC regulations for devices operating under Part N 22,N°27 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-095-V01.00 Page 2 of 33 Test Report No.: 11-094 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-095-V01.00 Page 3 of 33 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................7 3.1 TEST ENVIRONMENT..........................................................................................................................7 3.2 TEST EQUIPMENT..............................................................................................................................7 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON SERVICE PLUS GMBH) .................................................................................9 5 RF POWER OUT: §27.50, §2.1046; RSS-139, RSS-GEN ..................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................11 5.3.1.1 CDMA .............................................................................................................................12 5.3.1.2 W-CDMA.........................................................................................................................12 5.3.1.3 LTE .................................................................................................................................13 5.3.2 UPLINK....................................................................................................................................13 5.4 SUMMARY TEST RESULT...................................................................................................................13 6 OCCUPIED BANDWIDTH: §2.1049; RSS-GEN ..................................................................................14 6.1 LIMIT..........................................................................…

Text truncated - open the document above for the full version.

Test Report

Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full ECL-EMC Test Report No.: 11-096 Equipment under test: ION-M7P/85P/17P/19P 1900MHz Path XS5-ML7851719P FCC ID: 2237E-ML7851719P IC ID: FCC 47 CFR Part 24 Subpart E: 2011 Broadband PCS IC RSS-131:2003 Zone Enhancers for the Land Mobile Service Type of test: Measurement Procedures: 47 CFR Parts 2: 2011(Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), 24 (Broadband PCS), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards IC-GEN General Requirements and Information for the Certification of Radiocommunication Equipment Test result: Passed Date of issue: 26.04.11 Signature: Issue-No.: 01 Author: T. Zahlmann Test engineer Date of delivery: Checked: Head of the ECL M. Lehmann Test dates: 05.04.09 01.04. – Pages: 43 without the written approval of the testing laboratory. ECL-EMC-TR-11-096-V01.00 Page 1 of 43 Test Report No.: 11-095 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P ANDREW Wireless Systems GmbH Manufacturer: Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: HERBERG Service Plus GmbH European Compliance Laboratory (ECL) Thurn-und Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 0911 59835 23 Fax: +49 0911 59835 90 General: General: The purpose of this report is to show compliance to the FCC regulations for unlicensed devices operating under section 15.249 of the Code of Federal Regulations title 47. The purpose of this report is to show compliance to the FCC regulations for unlicensed devices operating under section 15.249 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-096-V01.00 Page 2 of 43 Test Report No.: 11-095 FCC ID: XS5-ML7851719P IC ID: 2237E-ML7851719P The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-11-096-V01.00 Page 3 of 43 Table of contents 1 TEST RESULTS SUMMARY .................................................................................................................5 2 EQUIPMENT UNDER TEST (E.U.T.) ....................................................................................................6 2.1 DESCRIPTION....................................................................................................................................6 2.1.1 DOWNLINK.................................................................................................................................6 2.1.2 UPLINK......................................................................................................................................6 2.1.3 DESCRIPTION OF EUT ................................................................................................................6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS..............................................................7 3 TEST SITE (ANDREW BUCHDORF) ....................................................................................................7 3.1 TEST ENVIRONMENT..........................................................................................................................7 3.2 TEST EQUIPMENT..............................................................................................................................7 3.3 INPUT AND OUTPUT LOSSES...............................................................................................................8 3.4 MEASUREMENT UNCERTAINTY............................................................................................................8 4 TEST SITE (TEMPTON SERVICE PLUS GMBH) .................................................................................9 5 RF POWER OUT: §24.232, §2.1046; RSS-133, RSS-GEN ................................................................10 5.1 LIMIT...............................................................................................................................................10 5.2 TEST METHOD.................................................................................................................................10 5.3 TEST RESULTS................................................................................................................................11 5.3.1 DOWNLINK...............................................................................................................................12 5.3.1.1 GSM................................................................................................................................13 5.3.1.2 GSM-EDGE ....................................................................................................................13 5.3.1.3 CDMA .............................................................................................................................14 5.3.1.4 W-CDMA.........................................................................................................................14 5.3.1.5 LTE .................................................................................................................................15 5.3.2 UPLINK....................................................................................................................................16 5.4 SUMMARY TEST RESULT...................................................................................................................16 6 OCCUPIED BANDWIDTH: §2.…

Text truncated - open the document above for the full version.

Test Setup Photos

Test setup Figure 1. EUT ION-M7P/85P/17P/19P Figure 2. Measurement Equipment and Remote Unit

Contact Information

Applicant

Jiri Cecka(Manager Quality)
[email protected]+420606620263Fax: +49-9099-69930

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
12272.11 GHz - 2.15 GHz20.14 W1M10G7D2.5 ppm
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures. Operating is limited to a maximum antenna hight of 10m above ground per 27.50(d)(2). RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3). This device must be professionally installed. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

Other Applications from Andrew Wireless System

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1 - FCC ID XS5-H23437HP - Andrew Wireless System
XS5-H23437HP

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1

Apr 10, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems - FCC ID XS5-CAPM2343737 - Andrew Wireless System
XS5-CAPM2343737

Era Repeater for cellular systems

Dec 14, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2BDOD - Andrew Wireless System
XS5-RML2BDOD

ERA L2 Radio Module

Oct 25, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit) - FCC ID XS5-CAPL2CBAND - Andrew Wireless System
XS5-CAPL2CBAND

Era Repeater for cellular systems (DAS - Remote Unit)

Dec 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2B25 - Andrew Wireless System
XS5-RML2B25

ERA L2 Radio Module

Sep 28, 2022

Equipment Class