FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Andrew Wireless System/
  3. XS5-UEUH19P2

XS5-UEUH19P2ION-U Remote Unit for cellular systems

Andrew Wireless System
ION-U Remote Unit for cellular systems - FCC ID XS5-UEUH19P2 - Andrew Wireless System
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Sep 22, 2013
Application Purpose
Original Equipment
Date of Application
Aug 27, 2013
Equipment Note
ION-U Remote Unit for cellular systems
Frequency Range
1930.00000000 - 1990.00000000
Company
Andrew Wireless System
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. HIGH POWER RU MECHANICAL INSTALLATIONN 1.1.1. General Read the health and safety warnings in chapter 1.3. 1. Warning: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. WARNING: IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT. Installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The supporting wall should be solid wood or concrete using appropriate screws and dowels (wall anchors). 3. Warning: It is recommended to use the mounting hardware delivered by the manufacturer only. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded.  Note: Exceeding the specified load limits may cause the loss of warranty! 4. Warning: The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 5. Caution: Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 6. Note: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 7. Note: Observe all additional rules or restrictions regarding mounting that apply to specific Remote Unit types. 8. Note: Observe all additional rules or restrictions regarding mounting that apply to specific Remote Unit types. For details refer to the mechanical specifications in the data sheet for the unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be maintained, as shown in the following illustrations: 9. A spacing of 40 mm (1.66 inch) around the unit is required. 10. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) must be provided. Do not block these air inlets and outlets when mounting the remote unit. The size of each opening must equal at least 12 x 12 cm (144 cm 2 ). Ensure that there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques must be observed for certain mounting procedures according to the following table: Type Tallow-drop screws Hex nuts Spacing bolts PG (plastic) PG (aluminium) Thread M 4 M 8 M 4 M 8 PG 13.5 PG 29 Specified torques 3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table Fehler! Kein Text mit angegebener Formatvorlage im Dokument.-1 Specified torques The mounting procedures for a stand-alone remote unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see the separate accessories manual. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in chapter 1.3. 1. Warning: This unit contains dangerous voltages. Loss of life, severe personal injury, or property damage can be the result if the instructions contained in this manual are not followed. 2. Caution: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Caution: Although the remote unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the remote unit for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Caution: If the mains connector of the remote unit is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 5. Caution: Before connecting or disconnecting the mains connector at the remote unit, ensure that mains power supply is disconnected. 6. Caution: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the Remote Unit. 7. Caution: A connection of the mains supply to a power socket requires the power socket to be nearby the remote unit. 8. Caution: Incorrectly wired connections can destroy electrical and electronic components. 9. Caution: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Note: Use an appropriate torque wrench to tighten the 7/16 DIN-type (1 ¼ -inch opening) antenna connectors to a coupling torque of 25 N-m / 19 ft lb. Torque wrench item no. 244377, available from the CommScope e-catalog, is recommended. Do NOT use your hands or any other tool (e. g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit or increased PIM. 11. Caution: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 12. Caution: The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) …

Text truncated - open the document above for the full version.

Users Manual

DRAFT ION ® -U EU H 19P2 Extension Unit User's Manual MF0200A0A Page 2 7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx User’s Manual for ION ® U DISCLAIMER: This document has been developed by CommScope, and is intended for the use of its customers and customer support personnel. The information in this document is subject to change without notice. While every effort has been made to eliminate errors, CommScope disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not claim to cover all details or variations in equipment, nor to provide for every possible incident to be met in connection with installation, operation, or maintenance. This document describes the performance of the product under the defined operational conditions and does not cover the performance under adverse or disturbed conditions. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, contact CommScope. CommScope reserves the right to change all hardware and software characteristics without notice. COPYRIGHT: © Copyright 2013 CommScope Inc. All Rights Reserved. This document is protected by copyright. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical photocopying, recording, or otherwise without the prior written permission of CommScope. TRADEMARKS All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. Andrew Wireless Systems GmbH, 08-July-2013 Table of contents 7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx User’s Manual for ION ® U Page 3 TABLE OF CONTENTS 1. GENERAL 6 1.1. USED ABBREVIATIONS 6 1.2. HEALTH AND SAFETY WARNINGS 7 1.3. ABOUT COMMSCOPE 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. INTRODUCTION 14 2.1. PURPOSE 14 2.2. ION-U HIGH POWER REMOTE AND EXTENSION UNITS 14 3. FUNCTIONAL DESCRIPTION 15 3.1.1. Fan Protection Kit 15 3.1.2. Accessories 15 4. COMMISSIONING 16 4.1. HIGH POWER RU MECHANICAL INSTALLATION 16 4.1.1. General 16 4.1.2. Wall-Mounting Procedure 18 4.1.3. Pole Mounting Procedure 19 4.1.4. Mounting of Fan Protection 20 4.2. ELECTRICAL INSTALLATION 22 4.2.1. General 22 4.2.2. Connections 23 4.2.3. Grounding (Earthing) 25 4.2.4. Connection of the Antenna Cable 25 4.2.5. Mains Power Connection 27 4.2.6. Extension Unit Port Connection 28 4.3. COMMISSIONING 30 5. ALARMS 33 5.1. BITE AND ALARMS 33 5.2. HANDLING OF ALARMS 33 5.3. ALARM STATUS 33 5.4. STATUS LED ALARMS 33 5.5. TROUBLESHOOTING 35 Table of contents Page 4 7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx User’s Manual for ION ® U 6. MAINTENANCE 36 6.1. GENERAL 36 6.2. REPLACING THE FAN UNIT 37 6.3. CLEANING THE HEAT SINK 39 7. APPENDIX 40 7.1. ILLUSTRATIONS 40 7.2. SPECIFICATIONS 43 7.3. SPARE PARTS 43 8. INDEX 44 figures and tables 7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx User’s Manual for ION ® U Page 5 FIGURES AND TABLES figure 3-3 Shroud with RU and EU ............................................................................. 15 figure 4-1 Wall Mounting ............................................................................................. 18 figure 4-2 Pole mounting kit ........................................................................................ 19 figure 4-3 Pole mounting drawing ............................................................................... 20 figure 4-4 Mounting procedure for fan protection ....................................................... 21 figure 4-5 ION-U H 17P2 Connectors ......................................................................... 23 figure 4-6 Grounding bolt ............................................................................................ 25 figure 4-7 Grounding bolt, schematic view ................................................................. 25 figure 4-8 Antenna port to CBC wiring ........................................................................ 26 figure 4-9 Mains power connector .............................................................................. 27 figure 4-10 Mains power cable - AC ........................................................................... 28 figure 4-11 EU (Extension Unit) connector ................................................................. 28 figure 4-12 Extension unit cable bridge ...................................................................... 29 figure 5-1 Alarm triggering .......................................................................................... 34 figure 7-1 Installation drawing-front and rear views ................................................... 40 figure 7-2 Installation drawing-side views ................................................................... 41 figure 7-3 Installation drawing-short version .............................................................. 42 table 1-1 List of international contact addresses ........................................................ 13 table 4-1 Specified torques ......................................................................................... 17 table 4-2: ION-U High Power EU Connectors ............................................................ 24 table 4-3 AC power cable ........................................................................................... 28 table 4-4 EU Connector .............................................................................................. 28 table 5-1 Status LED alarms ....................................................................................... 34 1. General Page 6 7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx User’s Manual for ION ® U 1…

Text truncated - open the document above for the full version.

External Photos

External Photos ION-U EU H 19P2

ID Label/Location Info

Label Location 11,5cm 6,5cm

Internal Photos

Internal Photos Fans and Cooling Frontflange ECPD+, Pic Board PSU and Amplifier PCS Duplexer Amplifier PCS Fin.Ampl. PCS eCPD+ Pic Modul Application Board

RF Exposure Info

RF Exposure Info / MPE Sample Calculation Model: ION-U EU H 19P2 FCC-ID: XS5-UEUH19P2 The ION-U is an optical fiber based DAS system that efficiently takes the outputs of multiple Base Transceiver Stations (BTS) sectors and converts those RF signals to optical to send them over fiber optic cables to remote units to provide coverage in indoor and outdoor locations. The system supports both low power and high power remotes units and SISO and MIMO operation. The ION-U H 19P2 is a high-power multi-operator 1900 MHz band Extension Unit (EU). It works in conjunction with a Master Unit in the ION-U optical distribution system and is connected to the main Remote Unit via an extension cable bridge. The Extension Unit adds an additional band (1900 MHz) to the main Remote Unit using the same fiber allowing multiple operators to transport signals to the DAS. The additional service or frequency band provided by the Extension Unit is achieved without any impact on the installed network. The compact mechanical design is specifically architected to be mounted inside poles or next to the main Remote Unit with a minimal visual impact. A shroud is available to mount the RU and EU in a single protected structure. The specific device generally will be professionally installed. Hereby the gain of the finally installed antenna(s), cable attenuation and antenna height will be defined site specific at the time of licensing with the appropriate FCC Bureau(s). The maximum permissible exposure limit is defined in 47 CFR 1.1310 (B). S = power density limit [W/m] P = power [W] R = distance [m] 2 4 n nn n R GP S   => n nn n S GP R 4  (to calculate the distance at one frequency) If we have more bands, than we have to calculated as a percentage: The additional of the terms have to be lower than 1. 1 4 .... 4 44 1.... 2 3 2 3 33 2 2 2 22 1 2 1 11 ln 3 3 2 2 1 1   n n nn n cacalcalcal S R GP S R GP S R GP S R GP S S S S S S S S   We are looking for a distance of ensures that the formula is satisfied. n RRRR... 321 1 4 ... 444 2 3 2 33 2 2 22 1 2 11  n nn SR GP SR GP SR GP SR GP  R S GP S GP S GP S GP R S GP S GP S GP S GP n nn n nn     4 ... 444 4 ... 444 3 33 2 22 1 11 2 3 33 2 22 1 11 With n nn n S GP R 4  => n nn n S GP R 4 2  RRRRR n  22 3 2 2 2 1 ... What you have to do for calculate the minimum distance were the power density limit is met: 1) If you have one path, you have to put you special values in the following formula. n nn n S GP R 4  (Distance for one carrier) Limits for General Population / Uncontrolled Exposures Frequency Range (MHz) Power Density (mW/cm 2 ) 300 – 1500 S = f/1500 1550 – 100,000 S = 1 2) If you have more than one path, you must add the individual terms quadratic. n nn n S GP R 4  (Distance for individual carrier) RRRRR n  22 3 2 2 2 1 ... (See previous page) For example: The EUT operates in one frequency band: 1930 MHz – 1990 MHz. The max measured conducted output power is 47.8 dBm. Calculation with maximum possible antenna gain and without cable loss: Frequency [MHz] Max Power out [dBm] Max. possible Antenna gain, without cable loss [dBi] Max. Distance [m] 1930 47.8 14.35 3.613 For more accurate calculation, the cable loss and actual antenna gain have to be included in the finally system. The antenna(s) used with device must be fixed-mounted on permanent structures with a distance to any human body to comply with the RF Exposure limit.

Test Report

EMC Test Report No.: 13-203 Test Site: FCC Test Site No.: 96997 IC OATS No.: IC3475A-1 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-13-203-V01.00 Page 1 of 37 Date of issue: 01.08.13 Signature: Issue-No.: 01 Author: Date of delivery: 22.07.13 Checked: Test dates: 12.07. – 23.07.13 Pages: 37 ECL-EMC Test Report No.: 13-203 Equipment under test: ION-U EU H 19P2 1900MHz Path FCC ID: XS5-UEUH19P2 Type of test: FCC 47 CFR Part 24 Subpart E Broadband PCS Measurement Procedures: 47 CFR Parts 2 (Frequency Allocations and Radio Treaty Matters; General Rules and Regulations), 24 (Broadband PCS), ANSI/TIA-603-C (2004), Land Mobile FM or PM Communications Equipment Measurement and Performance Standards Test result: Passed EMC Test Report No.: 13-203 FCC ID: XS5-UEUH19P2 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-13-203-V01.00 Page 2 of 37 Manufacturer: ANDREW Wireless Systems GmbH Industriering 10 D-86675 Buchdorf Tel.: +49 (0)9099 69 0 Fax: +49 (0)9099 69 140 Test Location: Bureau Veritas Consumer Products Services Germany GmbH European Compliance Laboratory (ECL) Thurn-und-Taxis-Straße 18 D-90411 Nürnberg Tel.: +49 40 74041 0 Fax: +49 40 74041-2755 General: The purpose of this report is to show compliance to the FCC regulations for unlicensed devices operating under section 15.249 of the Code of Federal Regulations title 47. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. EMC Test Report No.: 13-203 FCC ID: XS5-UEUH19P2 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-13-203-V01.00 Page 3 of 37 Table of contents 1 TEST RESULTS SUMMARY ................................................................................................................. 5 2 EQUIPMENT UNDER TEST (E.U.T.) .................................................................................................... 6 2.1 DESCRIPTION .................................................................................................................................... 6 2.1.1 DOWNLINK ................................................................................................................................. 6 2.1.2 UPLINK ...................................................................................................................................... 6 2.1.3 DESCRIPTION OF EUT ................................................................................................................ 6 2.1.4 BLOCK DIAGRAM OF MEASUREMENT REFERENCE POINTS .............................................................. 7 2.1.5 DOWNLINK SYSTEM GAIN AND OUTPUT POWER ........................................................................... 7 3 TEST SITE (ANDREW BUCHDORF) .................................................................................................... 8 3.1 TEST ENVIRONMENT .......................................................................................................................... 8 3.2 TEST EQUIPMENT .............................................................................................................................. 8 3.3 INPUT AND OUTPUT LOSSES ............................................................................................................... 8 3.4 MEASUREMENT UNCERTAINTY ............................................................................................................ 8 4 TEST SITE (BUREAU VERITAS CPS) .................................................................................................. 9 5 RF POWER OUT: FCC §24.232, §2.1046 ........................................................................................... 10 5.1 LIMIT............................................................................................................................................... 10 5.2 TEST METHOD ................................................................................................................................. 11 5.3 TEST RESULTS ................................................................................................................................ 11 5.3.1 DOWNLINK ............................................................................................................................... 12 5.3.1.1 CDMA ............................................................................................................................. 13 5.3.1.2 W-CDMA......................................................................................................................... 13 5.3.1.3 LTE ................................................................................................................................. 14 5.3.2 UPLINK .................................................................................................................................... 15 5.4 SUMMARY TEST RESULT ................................................................................................................... 15 6 OCCUPIED BANDWIDTH: FCC §2.1049; RSS-GEN ......................................................................... 16 6.1 LIMIT............................................................................................................................................... 16 6.2 TEST METHOD ................................................................................................................................. 16 6.3 TEST RESULTS ................................................................................................................................ 17 6.3.1 DOWNLINK ...............................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test setup Figure 1. EUT ION-U H 17P2 and ION-U EU H 19P2 Figure 2. Measurement Equipment

Contact Information

Applicant

Jiri Cecka(Manager Quality)
[email protected]+420606620263Fax: +49-9099-69930

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.93 GHz - 1.99 GHz60.256 WG7DAmp
Confidentiality
Long Term
Grant Notes
Output is at the antenna terminal (downlink) of an individual remote unit device. This transmitter operates as a band extension unit connected to a remote unit (FCC ID XS5-UH17P2) as part of a system along with master unit component(s) as described in this filing, and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with master unit connected to a base station in the uplink path; operations if any with master unit connected to antenna or amplifier in the uplink require separate equipment authorization. Antennas installed for each remote unit must provide a minimum separation distance from all persons as described in this filing.

Other Applications from Andrew Wireless System

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1 - FCC ID XS5-H23437HP - Andrew Wireless System
XS5-H23437HP

CAP H2 34T/37T F-AC-F1, CAP H2 34T/37T F-DC-F1

Apr 10, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems - FCC ID XS5-CAPM2343737 - Andrew Wireless System
XS5-CAPM2343737

Era Repeater for cellular systems

Dec 14, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2BDOD - Andrew Wireless System
XS5-RML2BDOD

ERA L2 Radio Module

Oct 25, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Era Repeater for cellular systems (DAS - Remote Unit) - FCC ID XS5-CAPL2CBAND - Andrew Wireless System
XS5-CAPL2CBAND

Era Repeater for cellular systems (DAS - Remote Unit)

Dec 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
ERA L2 Radio Module - FCC ID XS5-RML2B25 - Andrew Wireless System
XS5-RML2B25

ERA L2 Radio Module

Sep 28, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)