XTE-NODE102Wireless network module

Ingenu
Wireless network module - FCC ID XTE-NODE102 - Ingenu
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 21, 2015
Application Purpose
Original Equipment
Date of Application
Sep 21, 2015
Equipment Note
Wireless network module
Frequency Range
2402.00000000 - 2475.63000000
Company
Ingenu
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TOTAL REACH NETWORK On-Ramp Wireless Confidential and Proprietary. This document is not to be used, disclosed, or distributed to anyone without express written consent from On-Ramp Wireless, Inc. The recipient of this document shall respect the security of this document and maintain the confidentiality of the information it contains. The master copy of this document is stored in electronic format, therefore any hard or soft copy used for distribution purposes must be considered as uncontrolled. Reference should be made to On-Ramp Wireless, Inc. to obtain the latest revision. microNode Integration Specification On-Ramp Wireless, Inc. 10920 Via Frontera, Suite 200 San Diego, CA 92127 U.S.A. Copyright © 2015 On-Ramp Wireless, Inc. All Rights Reserved. The information disclosed in this document is proprietary to On-Ramp Wireless, Inc. and is not to be used or disclosed to unauthorized persons without the written consent of On-Ramp Wireless, Inc. The recipient of this document shall respect the security of this document and maintain the confidentiality of the information it contains. The master copy of this document is stored in electronic format, therefore any hard or soft copy used for distribution purposes must be considered as uncontrolled. Reference should be made to On-Ramp Wireless, Inc. to obtain the latest version. By accepting this material the recipient agrees that this material and the information contained therein is to be held in confidence and in trust and will not be used, copied, reproduced in whole or in part, nor its contents revealed in any manner to others without the express written permission of On-Ramp Wireless, Inc. On-Ramp Wireless, Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed for any damages arising directly or indirectly by their use or application. The information provided in this document is provided on an “as is” basis. This document contains On-Ramp Wireless, Inc. proprietary information and must be shredded when discarded. This documentation and the software described in it are copyrighted with all rights reserved. This documentation and the software may not be copied, except as otherwise provided in your software license or as expressly permitted in writing by On-Ramp Wireless, Inc. Any sample code herein is provided for your convenience and has not been tested or designed to work on any particular system configuration. It is provided “AS IS” and your use of this sample code, whether as provided or with any modification, is at your own risk. On-Ramp Wireless, Inc. undertakes no liability or responsibility with respect to the sample code, and disclaims all warranties, express and implied, including without limitation warranties on merchantability, fitness for a specified purpose, and infringement. On-Ramp Wireless, Inc. reserves all rights in the sample code, and permits use of this sample code only for educational and reference purposes. This technology and technical data may be subject to U.S. and international export, re-export or transfer (“export”) laws. Diversion contrary to U.S. and international law is strictly prohibited. RPMA® (Random Phase Multiple Access) is a registered trademark of On-Ramp Wireless, Inc. Other product and brand names may be trademarks or registered trademarks of their respective owners. microNode Integration Specification 014-0033-00 Rev. H April 8, 2015 On-Ramp Wireless, Inc. iii 014-0033-00 Rev. H Contents 1 Overview ................................................................................................................ 1 1.1 On-Ramp Total Reach Wireless Network .................................................................................. 1 1.2 microNode .................................................................................................................................. 2 1.3 Referenced Documents ............................................................................................................. 3 2 DC and AC Characteristics .................................................................................. 4 2.1 Absolute Maximum Ratings ....................................................................................................... 4 2.2 Recommended Operating Conditions ........................................................................................ 4 2.3 Effects of Temperature and Voltage .......................................................................................... 6 3 Electrical Interface .............................................................................................. 10 3.1 Signal Descriptions .................................................................................................................. 12 3.1.1 VBATT ............................................................................................................................ 12 3.1.2 POWER_ON ................................................................................................................... 12 3.1.3 RESET_N ....................................................................................................................... 12 3.1.4 MRQ ............................................................................................................................... 13 3.1.5 SRDY .............................................................................................................................. 13 3.1.6 SRQ ................................................................................................................................ 13 3.1.7 USTATUS ....................................................................................................................... 13 3.1.8 SPI System ..................................................................................................................... 13 3.1.9 ANT_SEL .......................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

On-Ramp Wireless, Inc 10920 Via Frontera, Suite 200 San Diego, CA 92127, USA +1 858 592 6008 : phone +1 858 592 6009 : fax [email protected] www.onrampwireless.com April 17, 2015 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD RE: Authority to Act as Agent IC ID: XTE-NODE102 Dear Sir or Madam, We, at On-Ramp Wireless, Inc., 10920 Via Frontera, Ste. 200, San Diego, CA 92127, hereby authorize Juan Manuel Gonzalez, at TÜV SÜD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121, Tel. 858-678-1400, to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on April 17, 2016. Sincerely, Jason Wilson VP Product Management, On-Ramp Wireless, Inc. 10920 Via Frontera, Suite 200, San Diego, CA 92127 Phone: 858-312-8356, Fax: 858-592-6009 [email protected]

Cover Letter(s)

On-Ramp Wireless, Inc 10920 Via Frontera, Suite 200 San Diego, CA 92127, USA +1 858 592 6008 : phone +1 858 592 6009 : fax [email protected] www.onrampwireless.com April 17, 2015 BABT FCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Attn: Director of Certification RE: Confidentiality Request FCC ID: XTE-NODE102 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, On-Ramp Wireless, Inc. hereby requests permanent confidential treatment of information accompanying this application as outlined below:  Schematics  Bill of Materials/Parts List and Placement  Operating Description/Theory of Operation  Block Diagrams On-Ramp Wireless, Inc. also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180 days):  Internal Photos  External Photos  User Manual  Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to On-Ramp Wireless, Inc. and provide unjustified benefits to its competitors. On-Ramp Wireless, Inc. understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Jason Wilson VP Product Management, On-Ramp Wireless, Inc. 10920 Via Frontera, Suite 200, San Diego, CA 92127 Phone: 858-312-8356, Fax: 858-592-6009 [email protected]

Cover Letter(s)

On-Ramp Wireless, Inc 10920 Via Frontera, Suite 200 San Diego, CA 92127, USA +1 858 592 6008 : phone +1 858 592 6009 : fax [email protected] www.onrampwireless.com On-Ramp Wireless, Inc. 1 April 17, 2015 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Request for Single Modular Approval On-Ramp Wireless, Inc. FCC ID: XTE-NODE102 FCC Part 15 Certification Dear Application Examiner, On-Ramp Wireless, Inc. module FCC ID: XTE-NODE102 is seeking FCC authorization as a Single Modular transmitter. The requirements of the FCC Part 15.212 are met for all requirements listed below. 1. The modular transmitter must have its own RF shielding The radio portion of this module has its own RF shielding. Please see the photos provided with the application. 2. The modular transmitter must have buffered modulation/data inputs The module has a memory management unit inside and buffers the data inputs from UART. 3. The modular transmitter must have its own power supply regulation The module contains its own voltage regulation. In case of changes in the supply voltage VCC (for example caused by temperature changes or other effects), the internal voltage will be stabilized. 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204c The module uses a unique surface mount antenna coupling method. The module was certified with a 9dBi monopole antenna and is specified for professional install with antennas of similar type and of less than or equal gain. 5. The modular transmitter must be tested in a stand-alone configuration The module was tested in a stand-alone configuration and was fixed on a development board. Please see the test report provided with this application. 6. The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. Please see the label provided with this application. That label will be affixed to all modules. 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. The module is compliant with all applicable FCC rules. Detailed instructions are provided in the product document entitled “microNode Integration Specification.” On-Ramp Wireless, Inc. 2 8. The modular transmitter must comply with any applicable RF exposure requirements. The device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. This module is approved for use in products operating as a fixed or mobile transmitting device. Kind Regards, Jason Wilson VP Product Management, On-Ramp Wireless, Inc. 10920 Via Frontera, Suite 200, San Diego, CA 92127 Phone: 858-312-8356, Fax: 858-592-6009 [email protected]

External Photos

FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 1 of 2 External Pictures FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 2 of 2

ID Label/Location Info

FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 1 of 2 LABEL Figure 1(Label) FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 2 of 2 Figure 2 (Label Location)

Internal Photos

FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 1 of 2 Internal Pictures FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Project No.: SD72102616 Page 2 of 2

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to isotropic R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:23.41(dBm) Maximum peak output power at antenna input terminal:219.28(mW) Antenna gain(typical):9(dBi) Maximum antenna gain:7.943(numeric) Prediction distance:20(cm) Sourse Based Time Average Duty Cycle:100(%) Pditi f2475 63(MH ) 2 4R PG S   Prediction frequency:2475.63(MHz) MPE limit for uncontrolled exposure at prediction frequency:1.000(mW/cm^2) Power density at prediction frequency:0.3465(mW/cm^2) Power density at prediction frequency:3.465(W/m^2) Margin of Compliance:-4.60(dB) 2 4R PG S  

Test Report

Report No. SD72102616Rev2.0-0215C September 2015 America ReportOn RadioTestingofthe OnRampWirelessInc. microNode2NODE1022.4GHzWirelesstransceivermodule FCCPart15SubpartC§15.247 ICRSS210Issue8December2010 FCCID:XTENODE102 ICID:8655ANODE102 ReportNo.SD72102616Rev2.00215C             REPORTON    TESTREPORTNUMBER  REPORTDATE   RadioTestingofthe OnRampWirelessInc microNode2NODE102  SD72102616Rev2.00215C  September2015  PREPAREDFOROnRampWireless Inc 10920ViaFrontera#200 SanDiego,CA92127   CONTACTPERSONAlainCharles (858) 5926008 [email protected] HardwareEngineer PREPAREDBYKathyMacKenzie Name Title:EMC/WirelessTestTechnician APPROVEDBYJuanManuelGonzalez Name AuthorizedSignatory Title:Commercial/WirelessEMCLabManager  DATED  15September2015  FCCID:XTENODE102 ICID:8655ANODE102 ReportNo.SD72102616Rev2.00215C Page3of59    RevisionHistory SD72102616Rev1.00215C OnRampWireless microNode2NODE102 2.4GHzWirelessTransceiverModule DATEOLDREVISIONNEWREVISIONREASON PAGES AFFECTED APPROVEDBY 08/07/2015InitialReleaseJuanM.Gonzalez 08/27/2015InitialReleaseRev1.0 CorrectionofAntennaGainvaluefrom 2.1dBito9.0dBi(Section1.3.2) 9JuanM.Gonzalez 09/15/2015REV1.0Rev2.0 Addanotefromcustomerexplaining thatpowerreductionwillbeused alongwiththisnew(9dBiAntenna)and Attestationletter(AnnexA) 9,16JuanM.Gonzalez          FCCID:XTENODE102 ICID:8655ANODE102 ReportNo.SD72102616Rev2.00215C Page4of59 CONTENTS  SectionPageNo  1 REPORT SUMMARY ................................................................................................................. 5  1.1Introduction ................................................................................................................................ 6 1.2Brief Summary of Results ........................................................................................................... 7 1.3Product Information .................................................................................................................... 8 1.4EUT Test configuration ............................................................................................................. 10 1.5Deviations from the Standard ................................................................................................... 12 1.6Modification Record ................................................................................................................. 12 1.7Test methodology ..................................................................................................................... 12 1.8Test facility location .................................................................................................................. 12 1.9Test facility Registration ........................................................................................................... 13 2 TEST DETAILS ........................................................................................................................ 14 2.1Peak output power ................................................................................................................... 15 2.2Conducted emissions ............................................................................................................... 17 2.399% EMISSION bandwidth ...................................................................................................... 21 2.4Minimum 6 dB RF bandwidth ................................................................................................... 24 2.5Out-of-band emissions - Conducted ......................................................................................... 27 2.6Band-edge Compliance of RF Conducted Emissions ............................................................... 34 2.7Spurious radiated emissions .................................................................................................... 36 2.8Radiated band edge measurements and Immediate restricted bands ...................................... 44 2.9Power spectral density ............................................................................................................. 48 3 TEST EQUIPMENT USED ....................................................................................................... 51 3.1Test Equipment Used ............................................................................................................... 52 3.2Measurement Uncertainty ........................................................................................................ 53 4 Diagram of test setup ............................................................................................................. 54 4.1Test setup diagram .................................................................................................................. 55 5 ACCREDITATION, DISCLAIMERS AND COPYRIGHT .......................................................... 58 5.1Accreditation, Disclaimers and Copyright ................................................................................. 59   FCCID:XTENODE102 ICID:8655ANODE102 ReportNo.SD72102616Rev2.00215C Page5of59  SECTION1 REPORTSUMMARY RadioTestingofthe OnRampWireless 2.4GHzWirelessTransceiverModule   FCCID:XTENODE102 ICID:8655ANODE102 ReportNo.SD72102616Rev2.00215C Page6of59 1.1INTRODUCTION   The information contained in this report is intended to show verification of the OnRamp Wireless Inc. microNode2NODE1022.4GHzWirelesstransceivermoduletotherequirementsofFCCPart15Subpart C§15.247andICRSS210Issue8December2010.  ObjectiveToperformRadioTesti…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Report No.: SD72102616 Page 1 of 5 Test Set Up Pictures Figure 1(EUT) FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Report No.: SD72102616 Page 2 of 5 Figure 2 (1GHz‐18GHz Front Picture) FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Report No.: SD72102616 Page 3 of 5 Figure 3 (1GHz‐18GHz Back Picture) FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Report No.: SD72102616 Page 4 of 5 Figure 4 (150KHz‐30MHz Front Picture) FCC ID Number XTE‐NODE102 /IC Number 8655A‐NODE102 Report No.: SD72102616 Page 5 of 5 Figure 5 (150KHz‐30MHz Side Picture)

Contact Information

Applicant

Eber Lambert(SR. DIRECTOR, ENGINEERING PROGRAM MANAGEMENT)
[email protected]619-535-3697Fax: 858-592-6009

Test Firm

TUV SUD America Inc.Mac Elliott
[email protected]813-284-2736Fax: 978 977 0182

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz177.82 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Approval. Power Output is conducted. This module must only be installed by the OEM or an OEM integrator. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Ingenu

Sectorized RPMA Access Point - FCC ID XTE-ULPAP210 - Ingenu
XTE-ULPAP210

Sectorized RPMA Access Point

May 12, 2015

Equipment Class

DTS - Digital Transmission System
Meter Communication Module - FCC ID XTE-TRN-2012 - Ingenu
XTE-TRN-2012

Meter Communication Module

Jun 02, 2013

Equipment Class

DTS - Digital Transmission System
Meter Communications Module - FCC ID XTE-TRN-2113 - Ingenu
XTE-TRN-2113

Meter Communications Module

Jun 02, 2013

Equipment Class

DTS - Digital Transmission System
Electric Meter Communications Module - FCC ID XTE-EM110100 - Ingenu
XTE-EM110100

Electric Meter Communications Module

Sep 30, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
The ULP dNode is a wireless network module - FCC ID XTE-ULPD100 - Ingenu
XTE-ULPD100

The ULP dNode is a wireless network module

Sep 10, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter