CONFIDENTIAL making the MFDs thinkβ’ Using Terminal UltraLight October 13, 2014 October 13, 2014 Using Terminal UltraLightCONFIDENTIAL2 TABLE OF CONTENTS 1FCC statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3Using the keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4Logging in at the printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4.1Logging out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5Printing all print jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5.1Print all jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5.2Print with Credit balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6Copying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 6.1Copy and scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 6.2Copy and scan with Credit balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7Terminal specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 8Terminal UltraLight beep and LED code sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 9Beep code sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 10LED code sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 October 13, 2014 Using Terminal UltraLightCONFIDENTIAL3 DOCUMENT DESCRIPTION At a Glance FCC statements Overview Using the keypad Logging in at the printer Logging out Printing all print jobs Print all jobs Print with Credit balance Copying Copy and scan Copy and scan with Credit balance Terminal specifications Terminal UltraLight beep and LED code sequences Beep code sequences LED code sequences October 13, 2014 Using Terminal UltraLightCONFIDENTIAL4 1 FCC STATEMENTS Β§ 15.21 Information to user The user's manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form. Β§ 15.105 Information to the user This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. October 13, 2014 Using Terminal UltraLightCONFIDENTIAL5 2 OVERVIEW YSoft SafeQ Terminal UltraLight provides a compact, fast, and easy-to-use interface for users to access multifunction printers (MFPs) and network printers to perform print, copy, and scan operations. The terminal supports and .Print roamingAuthorized copying The terminal has a touch keypad for user interaction. Users can authenticate with an ID card and/or by entering a PIN. Terminal UltraLight Print & Copy can provide authentication for printing and copying. Terminal UltraLight Print Only can provide authentication only for printing. You use the terminal to log in before using the printer. When logging in with a PIN, touch the keys to enter your PIN; then touch .OK October 13, 2014 Using Terminal UltraLightCONFIDENTIAL6 Terminal UltraLight is equipped with a 2-port Ethernet switch β the MFP or printer connects to the Ethernet network via the terminal. The terminal communicates with the YSoft SafeQ server over the Ethernet network. MFPs and other printers communicate with the YSoft SafeQ server via the terminal. The terminal also includes an Emergency button for performing service procedures. October 13, 2014 Using Terminal UltraLightCONFIDENTIAL7 The terminal also features: Microcomputer Flash ROM (Optional) Card reader β Various optional card readers are available to meet the compatibility requirements of your existing identification cards. (PINs can be used instead of the card reader.) October 13, 2014 Using Terminal UltraLightCONFIDENTIAL8 3 USING THE KEYPAD Terminal UltraLight's capacitive touch keypad does not require finger pressure β a light touch is enough. (The terminal may have been configured to emit a short beep to signal when it registers a touch.) (See .)Terminal UltraLight beep and LED code seqβ¦
Text truncated - open the document above for the full version.
DATE 09/29/2014 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: XUY0YX0ML01016 Product Name: Ultralight P&C 125kHz ASK FSK Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: β’ Schematics β’ Block diagram β’ Operational Description β’ Parts List These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 29th Day of September 2014 By: Pavel Slovak Signature Printed Title: Logistics & Purchasing Manager On behalf of : Y Soft Corporation, a.s. Telephone: +420 533 031 755
FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 1 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 EMI β T E S T R E P O R T - FCC Part 15.209 - Test Report No. : T38386-00-00GK 01. October 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : ML01016 Product Description : Ultralight P&C 125kHz ASK FSK Applicant : Y SOFT Corporation, a.s. Address : Czech Technology Park, Podnikatelska 2902/4 612 00 BRNO, Czech Republic Manufacturer : Y SOFT Corporation, a.s. Address : Czech Technology Park, Podnikatelska 2902/4 612 00 BRNO, Czech Republic Licence holder : Y SOFT Corporation, a.s. Address : Czech Technology Park, Podnikatelska 2902/4 612 00 BRNO, Czech Republic Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 2 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 3 E Q U I P M E N T U N D E R T E S T 5 3.1 Photo documentation of the EUT β Detailed photos see Attachment A 5 3.2 Power supply system utilised 5 3.3 Short description of the Equipment under Test (EUT) 5 4 T E S T E N V I R O N M E N T 6 4.1 Address of the test laboratory 6 4.2 Statement regarding the usage of logos in test reports 6 4.3 Environmental conditions 6 4.4 Statement of the measurement uncertainty 6 4.5 Measurement Protocol for FCC, VCCI and AUSTEL 7 5 T E S T C O N D I T I O N S A N D R E S U L T S 8 5.1 Conducted emissions 8 5.2 Field strength of the fundamental wave 12 5.3 Spurious emissions (magnetic field) 9 kHz β 30 MHz 14 5.4 Emission Bandwidth 16 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 18 FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 3 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1:1992 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 4 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 2 S U M M A R Y GENERAL REMARKS: The carrier frequency is 125.0 kHz. FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 24. June 2014 Testing concluded on : 23. July 2014 Checked by: Tested by: Klaus Gegenfurtner Teamleader Radio Konrad GraΓl FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 5 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 3 E Q U I P M E N T U N D E R T E S T 3.1 Photo documentation of the EUT β Detailed photos see Attachment A 3.2 Power supply system utilised Power supply voltage: : 100-240 V AC / 12.0 V DC / 50-60 Hz 3.3 Short description of the Equipment under Test (EUT) The EuT is a card reading terminal for reading of authentication cards. Number of tested samples: 1 Serial number: See photo documentation of the EuT in Attachment A EUT operation mode: The equipment under test was operated during the measurement under the following conditions: - Continuous Tx mode at 125 kHz - - EUT configuration: The following peripheral devices and interface cables were connected during the measurements: - Model : - Model : - Model : - customer specific cables - unscreened power cables FCC ID: XUY0YX0ML01016 CSA Group Bayern GmbH File No. T38386-00-00GK, page 6 of 18 Ohmstrasse 1-4 ο 94342 STRASSKIRCHEN ο GERMANY Tel.:+49(0)9424-94810 ο Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 4 T E S T E N V I R O N M E N T 4.1 Address of the test laboratory CSA Group Bayern GmbH Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY 4.2 Statement regarding the usage of logos in test reports The accreditation and notification body logos displayed in this test report are only valid for standards listed in the accreditation or notification scope of CSA Group Bayern GmbH. 4.3 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 Β° C Humidity: 30-60 % Atmospheric pressure: 86-106 kPa 4.4 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. It is noted that the expanded measurement uncertainty corresponds to the measurement results from the standard measurement uncertainty multiplied by the coverage factor k = β¦
Text truncated - open the document above for the full version.
T38386-00-00GK FCC ID: XUY0YX0ML01016 Photo documentation of the test set-up Conducted emissions Field strength of the fundamental wave Spurious emissions (magnetic field) 9 kHz β 30 MHz Emission Bandwidth
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |
MFX4 Ultimate Reader
Equipment Class
DTS - Digital Transmission System
External reader module ASK FSK
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Terminal Pro 125kHz ASK FSK
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Multireader HF
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter