XVREHMID1HVAC Performance Monitoring Kit

Trane US, Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 03, 2026
Application Purpose
Original Equipment
Equipment Note
HVAC Performance Monitoring Kit
Frequency Range
903.00000000 - 926.90000000
Company
Trane US, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered list Attestation Statement Date: June 10, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: FCC ID: XVREHMID1 47 CFR section 2.911(d)(5)(i) Attestation Statement Trane US, Inc. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. * - is / - is not support router function* *If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. *If the device for which the applicant is seeking authorization is a router device newly added to the protected list, a Conditional Approval by DoW/DHS letter or clarification proving that the product's "Manufacturing + Assembly + Design + Development" were all conducted in the United States is required. Trane US, Inc. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a).” Additional Explanation: N/A 47 CFR section 2.911(d)(5)(ii) Attestation Statement Trane US, Inc. (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Signature Contact Name: Daniel Blair Job Title: Strategic Systems Architect Email: [email protected]

Attestation Statements

U.S. Agent Authorized Letter Date: June 10, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Attestation Statements Part 2.911(d)(7) Filing FCC ID: XVREHMID1 To Whom It May Concern: This letter is to confirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information changes. Sincerely, Company: Trane US, Inc. FRN: 0019243005 Address: 6200 Troup Highway, TYLER, Texas, 75707, United States Contact Name: Daniel Blair Title: Strategic Systems Architect Tel.: 903-730-4487 Email: [email protected]

Cover Letter(s)

Authorization Letter Date: June 10, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: XVREHMID1 To Whom It May Concern: We, the undersigned, hereby authorize the following person on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by DEKRA Testing and Certification Co., Ltd. on our behalf shall have the same effect as acts of our own. Agent Company name : DEKRA Testing and Certification Co., Ltd. Address : No. 26, Hwaya 1st Road., Guishan District, Taoyuan City, 33341, Taiwan Contact Name : Stanley Wu Email : [email protected] We are therefore responsible for the contents of the application. Product description : HVAC Performance Monitoring Kit Model No. : D163236G01 Brand : Trane Sincerely, Signature Contact Name: Daniel Blair Job Title: Strategic Systems Architect Email: [email protected]

Cover Letter(s)

Confidential Request Letter Date: June 10, 2026 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for confidentiality FCC ID: XVREHMID1 Long-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Tune-up procedure Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Short-Term Confidentiality (STC) Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Internal Photos User’s Manual External Photos Test Set-up Photos Justification: Due to market confidential, we ask for the short-term confidentiality. Planned Release Date STC: If no date is given, 180 days from grant date will be used. Sincerely, Signature Contact Name: Daniel Blair Job Title: Strategic Systems Architect Email: [email protected]

ID Label/Location Info

INDOOR UNIT LABEL LOCATION

ID Label/Location Info

14-APR-26 UPDATE LABEL INFORMATION 18-MAR-26 INITIAL ISSUE X1X2 NP-F-0039 ALL DIMENSIONS IN MILLIMETRES. 0.3 PCI Private Limited, and is confidential material. REV DESCRIPTION DATE DRAWN BY DATE APPROVED BY (ORIGINATOR'S DEPT HEAD)RELEASED BY (ORIGINATOR)TITLE CUSTOMERSPEC OR DWG NUMBER GENERAL TOLERANCE ONE DECIMAL PL TWO DECIMAL PL ANGULAR MATERIAL OR SOURCE FINISH SCALE 3RD ANGLE FORMAT FOR SPECIFICATION AND DRAWING SHT This document/data record is the property of 20-JAN-2022 SHELLEY MAE C. VENIEGAS 18-MAR-26 ROBIN RAMISO JOEY DELA CRUZ TRANE - 1 1 SHT REVISIONS ARE INDICATED BY TRIANGLED LETTERS. DWG TK TRLB00060 PRODUCT LABEL Font: 5 point Data Matrix Barcode A26F01845237 18V P2 Font: 6 point NOTE:1. To be printed in-house.2. Font: Arial 3. Logo and text must be print in Black 4. MODEL: D163236G01-for Indoor Unit5. SERIAL NUMBER: YY = 2-digit year WW = 2-digit week MM = Trane-Assigned Manufacturer Code (“P1” for Outdoor Module and “P2” for Indoor Module) CCC = count of number of units produced e ach week (Base 31 format recommended but not re quired) X = is fixed 6. VENDOR CODE: P2 for Indoor Unit7. FCC ID: XVREHMID1 8. IC: 6178D-EHMID19. CAN ICES-3(B)/NMB-3(B)- Based on certificatio n 10. DEVICE ID: Will be generated based on progra mmable device. BYYF01845237 temporary place holder Unit Type Character: A = Outdoor Unit B = Indoor Unit YY = Year F0 = Random Code 1845237 = Rando m 7 digits 11. Generate "Data matrix barcode format". The "Start of Record" indicator to be include d in the barcode is "[)>06". [)> 06P D163236G01 1P BAYEHMKTAW00DAA S 2623P2000X 17D 01062026 V Font: 5 point

RF Exposure Info

Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 1 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 Test Report No: 2630761R-RFUSV17S-A RF EXPOSURE EVALUATION D ECLARATION Product Name HVAC Performance Monitoring Kit Brand Name Trane Model No. D163236G01 FCC ID XVREHMID1 Applicant ́s Name / Address Trane US, Inc. 6200 Troup Highway, Tyler, TX 75707, United States Manufacturer’s N ame / Address Trane US, Inc. 6200 Troup Highway, Tyler, TX 75707, United States Te s t Method Requested, Standard FCC CFR Title 47 Part 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. Verdict Summary IN COMPLIANCE Documented By Hailey Peng Approved By Rueyyan Lin Date of Receipt Mar. 26, 2026 Date of Issue Jun. 18, 2026 Report Version V1.0 Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 2 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 INDEX page Competences and Guarantees ................................................................................................................................ 3 General Conditions .................................................................................................................................................. 3 Revision History ....................................................................................................................................................... 4 1. General Information ............................................................................................................................... 5 1.1. EUT Description .................................................................................................................................... 5 1.2. Testing Location Information ................................................................................................................. 5 2. RF Exposure Evaluation ........................................................................................................................ 6 2.1. Test Limit ............................................................................................................................................... 6 2.2. Test Result of RF Exposure Evaluation ................................................................................................. 7 Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 3 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 Competences and Guarantees DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA. General Conditions 1. The test results relate only to the samples tested. 2. The test results shown in the test report are traceable to the national/international standard through the calibration report of the equipment and evaluated measurement uncertainty herein. 3. This report must not be used to claim product endorsement by TAF or any agency of the government. 4. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification Co., Ltd. 5. Measurement uncertainties evaluated for each testing system and associated connections are given here to provide the system information for reference. Compliance determinations do not take into account measurement uncertainties for each testing system, but are based on the results of the compliance measurement. Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 4 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 Revision History Version Description Issued Date V0.1-Draft Initial issue of report Apr. 27, 2026 Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 5 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 1. General Information 1.1. EUT Description RF General Information Evaluation Mode Frequency Range (MHz) Operating Frequency (MHz) Modulation Type LoRa 902 ~ 928 903 ~ 926.9 Chirp Spread Spectrum (CSS) Note: The above EUT information is declared by the manufacturer. 1.2. Testing Location Information Testing Location Information Test Laboratory:DEKRA Testing and Certification Co., Ltd. 1 ADD: No.372-2, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County 31061, Taiwan, R.O.C. (TAF: 3024) TEL: +886-3-582-8001 FAX: +886-3-582-8958 Test site Designation No. TW3024 with FCC. Conformity Assessment Body Identifier (CABID) TW3024 with ISED. 2 ADD: No.372, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County 31061, Taiwan, R.O.C. (TAF: 3024) TEL: +886-3-582-8001 FAX: +886-3-582-8958 Test site Designation No. TW3024 with FCC. Conformity Assessment Body Identifier (CABID) TW3024 with ISED. Test site number for address 1 includes HC-SR02 and HC-CB10. Test site number for address 2 includes HC-CB02, HC-CB04, HC-SR10 and HC-SR12. Report No.:2630761R-RFUSV17S-A TEL : +886-3-582-8001 Page Number : 6 of 7 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 2. RF Exposure Evaluation 2.1. Test Limit (A) Test Limit for Occ…

Text truncated - open the document above for the full version.

Test Report

Report No.:2630761R-RFUSV01S-A TEL : +886-3-582-8001 Page Number : 1 of 21 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 Test Report No: 2630761R-RFUSV01S-A TEST REPORT FCC Rules&Regulations Product Name HVAC Performance Monitoring Kit Brand Name Trane Model No. D163236G01 FCC ID XVREHMID1 Applicant ́s Name / Address Trane US, Inc. 6200 Troup Highway, Tyler, TX 75707, United States Manufacturer’s Name / Address Trane US, Inc. 6200 Troup Highway, Tyler, TX 75707, United States Test Method Requested, Standard FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 Verdict Summary IN COMPLIANCE Documented By Hailey Peng Approved By Rueyyan Lin Date of Receipt Mar. 26, 2026 Date of Issue Jun. 18, 2026 Report Version V1.0 Report No.:2630761R-RFUSV01S-A TEL : +886-3-582-8001 Page Number : 2 of 21 FAX : +886-3-582-8958 Issued Date : Jun. 18, 2026 Report Version : V1.0 INDEX page Competences and Guarantees ............................................................................................................................... 4 General Conditions ................................................................................................................................................. 4 Revision History ...................................................................................................................................................... 5 Summary of Test Result .......................................................................................................................................... 6 Comments and Remarks ........................................................................................................................................ 6 1. General Information ................................................................................................................................. 7 1.1. EUT Description ...................................................................................................................................... 7 1.2. EUT Information ...................................................................................................................................... 8 1.3. Testing Applied Standards ....................................................................................................................... 8 1.4. Testing Location Information ................................................................................................................... 9 1.5. Measurement Uncertainty ....................................................................................................................... 9 1.6. List of Test Equipment ........................................................................................................................... 10 2. Test Configuration of EUT ..................................................................................................................... 11 2.1. Test Condition ........................................................................................................................................ 11 2.2. Test Frequency Mode ............................................................................................................................ 11 2.3. Duty Cycle ............................................................................................................................................. 12 2.4. The Worst Case Measurement Configuration ....................................................................................... 13 2.5. Tested System Details ........................................................................................................................... 14 2.6. Configuration of Tested System ............................................................................................................ 14 3. AC Power Line Conducted Emission .................................................................................................... 15 3.1. Test Setup ............................................................................................................................................. 15 3.2. Test Limit ............................................................................................................................................... 15 3.3. Test Procedure ...................................................................................................................................... 15 3.4. Test Result of AC Power Line Conducted Emission ............................................................................. 15 4. Occupied Bandwidth & DTS Bandwidth ................................................................................................ 16 4.1. Test Setup ............................................................................................................................................. 16 4.2. Test Limit ............................................................................................................................................... 16 4.3. Test Procedures .................................................................................................................................... 16 4.4. Test Result of Occupied Bandwidth & DTS Bandwidth ......................................................................... 16 5. Maximum Conducted Output Power ..................................................................................................... 17 5.1. Test Setup ............................................................................................................................................. 17 5.2. Test Limit ............................................................................................................................................... 17 5.3. Test Procedures .......................................................................…

Text truncated - open the document above for the full version.

Test Report

Antenna Gain Report for Trane EHM (Indoor) 1. Test date and person Test date: 23 Mar 2026 Test person: Xie Jiahua 2. Test setup and equipment Test laboratory PCI fully anechoic OTA chamber ETS Lindgren AMS-8500 and EMQuest v1.19 is used. Equipment used Name Manufacturer Model ENA Series Network Analyzer Keysight E5063A PCI antenna measurement system + anechoic chamber ETS-Lindgren AMS8500 S11 Measurement Setup Setup Overview of Antenna Measurement System (AMS 8500) for Gain, Total Efficiency, and Radiation Pattern Sample Setup in Anechoic Chamber 3. Antenna specifications 3.1 LoRa Antenna Antenna type: PCB trace antenna (internal) Antenna manufacturer name: NA Manufacturing part number: NA Peak gain: Frequency (MHz) Peak Gain (dBi) 902 – 928 0.87 Radiation pattern: f=910MHz: Electrical and mechanical specifications: Electrical Frequency 902 – 928GHz S11 < -8 dB Maximum Gain [email protected] Total Efficiency ~60% Mechanical Dimension 56mm x 11mm

Contact Information

Applicant

Daniel Blair(Strategic Systems Architect)
[email protected]Fax: 903-730-4487

Technical Contact

Trane US, Inc.Daniel Blair
[email protected]Fax: 903-730-4487

6200 Troup Highway · TYLER, Texas, 75707 · United States

Test Firm

DEKRA TESTING AND CERTIFICATION CO., LTD.Warren Lin
[email protected]Fax: +886-3-582-8958

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 926.9 MHz150.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

Other Applications from Trane US, Inc.

XVREHMOD1

HVAC Performance Monitoring Kit

Jul 03, 2026

Equipment Class

DTS - Digital Transmission System
COLOR WIFI Z-WAVE THERMOSTAT - FCC ID XVRZON1054 - Trane US, Inc.
XVRZON1054

COLOR WIFI Z-WAVE THERMOSTAT

Dec 12, 2022

Equipment Class

DTS - Digital Transmission System
Smart Thermostat with Wireless Control - FCC ID XVRZONE950B - Trane US, Inc.
XVRZONE950B

Smart Thermostat with Wireless Control

Jan 29, 2015

Equipment Class

DTS - Digital Transmission System
Color Touchscreen Wi-Fi Thermostat - FCC ID XVR-CONT8501 - Trane US, Inc.
XVR-CONT8501

Color Touchscreen Wi-Fi Thermostat

Apr 01, 2014

Equipment Class

DTS - Digital Transmission System
Color Touchscreen Wi-Fi - FCC ID XVR-CONT8241 - Trane US, Inc.
XVR-CONT8241

Color Touchscreen Wi-Fi

Jan 10, 2014

Equipment Class

DTS - Digital Transmission System