Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
V1.0 Attestation Letter Date: Feb. 20, 2020 Federal Communications Commission Authorization and Evaluation Division FCC ID: Y9E-IAD18009 We, IAdea Corporation, declare that the device does not support channel 12 ~ 13 in 2.4 GHz band and any non-US channels in all the operational mode(s) for the following product. Product: Smart Signboard Model: IAD-18001 FCC ID: Y9E-IAD18009 If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! Sincerely, __________________ Name: Yung-Tsai Wang Position: Director of product development IAdea Corporation Web site: www.iadea.com IAdea Corporation 3F, No. 21, Lane 168, Xingshan Road, Neihu Dist., Taipei City 11469, Taiwan, R.O.C. Tel : 886-2-2791-1110/ Fax: 886-2-2791-1170 Yung-Tsai WangYung-Tsai Wang
IAdea Corporation 3F, No. 21, Lane 168, Xingshan Road, Neihu Dist., Taipei City 11469, Taiwan, R.O.C. Tel : 886-2-2791-1110/ Fax: 886-2-2791-1170 Authority to Act as Agent Date: February 19, 2020 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: AUDIX Technology(Shenzhen)Co.,Ltd. is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: ____10 months_____ By: __________________________ (Signature 1 ) (Company Name) Client's name/Title: Yung-Tsai Wang/Director of product development Contact information/(Tel): Clyde.Wang/+1-949-305-6489x200 On behalf of: IAdea Corporation__
Request for Confidentiality Date: February 19, 2020 Subject: Confidentiality Request for: Y9E-IAD18009 Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 9.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐Short Term☒PermanentBlock Diagrams ☐Short TermExternal Photos ☐Short Term☐Permanent * 1 Internal Photos ☐Short Term☒PermanentOperation Description/Theory of Operation ☐Short Term☐PermanentParts List & Placement/BOM ☐Short Term☐PermanentTune-Up Procedure ☐Short Term☒Permanent Schematics ☐Short TermTest Setup Photos ☐Short Term☐Permanent * 3 User’s Manual IAdea Corporation_ has spent substantial effort in developing this product and it is one of t he first of its kind in industry. Having the subject information easily available to "competition" woul d negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) 2 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _____________/ Director of product development_ (Signature/Title 3 ) IAdea Corporation 3F, No. 21, Lane 168, Xingshan Road, Neihu Dist., Taipei City 11469, Taiwan, R.O.C. Tel : 886-2-2791-1110/ Fax: 886-2-2791-1170 Client's name/Title: Yung-Tsai Wang/Director of product development Contact information/(Tel): Clyde.Wang/+1-949-305-6489x200
AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 1 of 15 Appendix B. Photo of the EUT Figure 1 General Appearance of the EUT Figure 2 General Appearance of the EUT
IAdea XDS-1098 label label Part NO.: 内销中文字体要求高度1.8mm以上 Yes No Q40MRP1005905A 针对带有UL logo的标签,其厂家须在 最小包装上标示UL Recognized Component Mark 公司名称, 型号及 UL file no. 捷联电子(福建)有限公司 TPV Electronics (Fujian) Co., Ltd. 地址(Add):中国福建省福清市元洪路上郑 Shangzheng,Yuanhong Road, Fuqing City, Fujian Province, China 电话(Tel):+86-591-85285555 85285559 传真(Fax):+86-591-85285447 郵編(Postcode):350301 条码印刷: barcode print: 1.所有条码读码等级:C级及以上, 客户有特殊要求除外; REVISION VERSION A 备注Remark: 安规签核Safety parts: Yes No xiaoling.zheng Dec-12-19 NOTE: 1.印刷如上图 Printing as the drawing 2.尺寸:具体见上图所示 (公差:+/-0.2mm),R=1mm Dimension:as the above drawing(Tolerance:+/-0.2mm),R=1mm 3.材质:50#PET带不干背胶(材质需经过UL认证). Material:50#PET with grid glue on the backside (material must be certified by UL laboratory) 4.底色:透明;字体颜色:50% 黑色 Backgound color:transparent Fonts color:50% black 5.贴附位置:后壳ID槽内 6.粘力:将label切成25mm宽,一端粘贴于钢板上,以180°方向的力拉胶带另一端,所得拉力即为粘力。用粘力测试仪进行测试. Stickiness strength :Cut label into 25mm width ,one end paste on the plate , with 180 ° direction pulling the other end of the tape, the pull is stickiness strength. With stickiness strength instrument for testing. 7.正常耐温测试:在钢板上耐温范围为-20~100°C,在80~100°C保持8小时后不翘角,不分层,不脱落,不起泡等. 在塑胶、纸箱上耐温范围为-20~65° C, 在65°C保持8小时后不翘角,不分层,不脱落,不起泡等. The normal temperature test: The range of temperature on plate is -20 ~ 100 ° C . In 80 ~ 100 ° C to maintain 8 hours , the label should not be warp,delamination,frothy and so on. The range of temperature on plastic and carton is -20 ~ 65 ° C. In 65 ° C to maintain 8 hours ,the label should not be warp, delamination,frothy and so on. 8.耐温湿度循环测试:循环条件:温度-20~65°C,湿度30~90%,时间 96小时后不翘角不分层不脱落不起泡等. Temperature and humidity cycle test : Cycle conditions:In temperature of -20 ~ 65 ° C and humidity of 30~90%to maintain 96 hours , the label should not be warp,delamination,frothy and so on. 9.裁切需均匀且印刷不可有溢墨及颜色不均等不良现象. Printing ink can not have overflow and printing color can not be uneven etc. 10.其它测试要求详见(FQ-背胶类产品测试检验规格). 备註: 1. Rating label材料为50#透明网格PET, 字符50%黑色 Input:12V 1.5A USB output: 5V 500mA each XDS-1098 XDS-1098 Y9E-IAD18009 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Input:12V 1.5A USB output: 5V 500mA each XDS-1098 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 2 of 15 Figure 3 Inside of the EUT Figure 4 Inside of the EUT Antenna AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 3 of 15 Figure 5 Inside of the EUT Figure 6 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 4 of 15 Figure 7 Inside of the EUT Figure 8 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 5 of 15 Figure 9 Inside of the EUT Figure 10 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 6 of 15 Figure 11 Inside of the EUT Figure 12 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 7 of 15 Figure 13 Inside of the EUT Figure 14 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 8 of 15 Figure 15 Inside of the EUT Figure 16 Inside of the EUT Antenna Port AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 9 of 15 Figure 17 Inside of the EUT Figure 18 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 10 of 15 Figure 19 Inside of the EUT Figure 20 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 11 of 15 Figure 21 Inside of the EUT Figure 22 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 12 of 15 Figure 23 Inside of the EUT Figure 24 Inside of the EUT AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 13 of 15 Figure 25 Inside of the EUT Figure 26 Power Adapter AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 14 of 15 Figure 27 Power Adapter Figure 28 Power Adapter AUDIX Technology (Shenzhen) Co., Ltd. Audix Technology (Shenzhen) Co., Ltd. Appendix B Page 15 of 15 Figure 29 Power Adapter
Audix Technology (Shenzhen) Co., Ltd. Tel: 0755 26639496 No. 6, Kefeng Road, Science & Technology Park, Fax: 0755 26632877 Nanshan District , Shenzhen, Guangdong, China Maximum Permissive Exposure FCC ID: Y9E-IAD18009 EUT: Smart Signboard Model No.: IAD-18001 1. According to FCC CFR 47 §1.1310, the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b). Table 1 Limits for Maximum Permissible Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A) Limits for Occupational / Control Exposures (f = frequency) 30-300 61.4 0.163 1.0 6 300-1500 --- --- f/300 6 1500-100,000 --- --- 5.0 6 (B) Limits for General Population / Uncontrolled Exposures (f = frequency) 30-300 27.5 0.073 0.2 30 300-1500 --- --- f/1500 30 1500-100,000 --- --- 1.0 30 Audix Technology (Shenzhen) Co., Ltd. Tel: 0755 26639496 No. 6, Kefeng Road, Science & Technology Park, Fax: 0755 26632877 Nanshan District , Shenzhen, Guangdong, China 2. MPE Calculation Sony Corporation declares that the product described above has been evaluated and found to comply with the RF exposure limits for humans, as specified based on ANSI/FCC recommendation. RF Exposure Calculations: S = (P * G) / (4* π * r^2) or r = √(P * G) / (4 * π * S) 2.1. Estimation Result Mode Frequency (MHz) Output power (dBm) Output power (mW) antenna Gain (dBi) antenna Gain (linear) MPE (mW/cm 2 ) 11b 2412 15.69 37.07 1.98 1.58 0.011640 2437 15.81 38.11 1.98 1.58 0.011966 2462 15.25 33.50 1.98 1.58 0.010518 11g 2412 11.77 15.03 1.98 1.58 0.004720 2437 13.56 22.70 1.98 1.58 0.007128 2462 11.80 15.14 1.98 1.58 0.004753 11n HT20 2412 10.31 10.74 1.98 1.58 0.003372 2437 13.09 20.37 1.98 1.58 0.006397 2462 10.80 12.02 1.98 1.58 0.003775 11n HT40 2422 10.61 11.51 1.98 1.58 0.003614 2437 10.32 10.76 1.98 1.58 0.003380 2452 10.44 11.07 1.98 1.58 0.003475 Based on safety distance (r) 20cm, the antenna gain (G) is 1.58 Numerical, and the highest power output (P) is 38.11mW, the power density (S) is 0.011966mW/cm 2 .
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 1 of 123 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of IAdea Corporation Smart Signboard IAD-18001 FCC ID: Y9E-IAD18009 Prepared for : IAdea Corporation 3F, No.21, Lane 168, Xingshan Road, Neihu Dist. Taipei, 114 Taiwan Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F20013 Date of Test : Dec.04,2019~Jan.20,2020 Date of Report : Feb.20,2020 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 2 of 123 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 5 1.1. Description of Standards and Results ...................................................................................... 5 2. GENERAL INFORMATION ............................................................................................. 6 2.1. Description of Equipment Under Test .................................................................................... 6 2.2. Tested Supporting System Details .......................................................................................... 7 2.3. Block diagram of connection between the EUT and simulators ............................................. 7 2.4. Test Information ...................................................................................................................... 7 2.5. Test Facility ............................................................................................................................. 8 2.6. Measurement Uncertainty (95% confidence levels, k=2) ....................................................... 8 3. POWER LINE CONDUCTED EMISSION TEST .......................................................... 9 3.1. Test Equipments ...................................................................................................................... 9 3.2. Block Diagram of Test Setup .................................................................................................. 9 3.3. Power Line Conducted Emission Test Limits ......................................................................... 9 3.4. Configuration of EUT on Test .............................................................................................. 10 3.5. Operating Condition of EUT ................................................................................................. 10 3.6. Test Procedure ....................................................................................................................... 10 3.7. Power Line Conducted Emission Test Results ...................................................................... 10 4. RADIATED EMISSION TEST ........................................................................................ 13 4.1. Test Equipment ..................................................................................................................... 13 4.2. Block Diagram of Test Setup ................................................................................................ 14 4.3. Radiated Emission Limit ....................................................................................................... 15 4.4. EUT Configuration on Test ................................................................................................... 15 4.5. Operating Condition of EUT ................................................................................................. 16 4.6. Test Procedure ....................................................................................................................... 16 4.7. Radiated Emission Test Results ............................................................................................ 16 5. CONDUCTED SPURIOUS EMISSIONS ....................................................................... 68 5.1. Test Equipment ..................................................................................................................... 68 5.2. Block Diagram of Test Setup ................................................................................................ 68 5.3. Limit ...................................................................................................................................... 68 5.4. Test Procedure ....................................................................................................................... 68 5.5. Test result .............................................................................................................................. 68 6. BAND EDGE COMPLIANCE TEST.............................................................................. 77 6.1. Test Equipment ..................................................................................................................... 77 6.2. Limit ...................................................................................................................................... 77 6.3. Test Procedure ....................................................................................................................... 77 6.4. Test Results ........................................................................................................................... 77 7. 6dB Bandwidth Test ........................................................................................................ 110 7.1. Test Equipment ................................................................................................................... 110 7.2. Block Diagram of Test Setup .............................................................................................. 110 7.3. Limit ........................................................................…
Text truncated - open the document above for the full version.
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 71 of 123 Test CH6: 2437MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 72 of 123 Test CH11: 2462MHz Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 73 of 123 Test CH6: 2437MHz Test CH11: 2462MHz
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 74 of 123 Test Mode: IEEE 802.11n HT40 Test CH3: 2422MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 75 of 123 Test CH6: 2437MHz Test CH9: 2452MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 76 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 77 of 123 6. BAND EDGE COMPLIANCE TEST 6.1. Test Equipment Item Equipment ManufacturerModel No. Serial No. Last Cal. Cal. Interval 1. PXA Signal AnalyzerAgilent N9030A MY51380221 Jun.30,19 1 Year 2. Amplifier HP 8449B 3008A02495 Apr.23,19 1 Year 3. Horn Antenna ETS 3115 9607-4580 Dec.13,18 3 Year 4. RF Cable EMCI EMC102-KM-KM 3500170702 May.13,1 9 1 Year 6.2. Limit All the lower and upper band-edges emissions appearing within 2310MHz to 2390MHz and 2483.5MHz to 2500MHz restricted frequency bands shall not exceed the limits shown in 15.209, all the other emissions outside operation frequency band 2400MHz to 2483.5MHz shall be at least 20dB below the fundamental emissions, or comply with 15.209 limits. 6.3. Test Procedure Use the test method descried in ANSI C63.10 clause 6.10: 1. The EUT is placed on a turntable, which is 1.5m above the ground plane and worked at highest radiated power. 2. The turntable was rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest emission. 4. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the emission: (a) PEAK: RBW=1MHz; VBW=3MHz; Sweep=AUTO (b) AVERAGE: RBW=1MHz; VBW=10Hz; Sweep=AUTO 6.4. Test Results Pass (The testing data was attached in the next pages.) AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 78 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 79 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 80 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 81 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 82 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 83 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 84 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 85 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 86 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 87 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 88 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 89 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 90 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 91 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 92 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 93 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 94 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 95 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 96 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 97 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 98 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 99 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 100 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 101 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 102 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 103 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 104 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 105 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 106 of 123 AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 107 of 123 AUDIX…
Text truncated - open the document above for the full version.
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 112 of 123 Test Mode: IEEE 802.11b Test CH1: 2412MHz Test Mode: IEEE 802.11g Test CH1: 2412MHz Test CH6: 2437MHz Test CH6: 2437MHz Test CH11: 2462MHz Test CH11: 2462MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 113 of 123 Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz Test Mode: IEEE 802.11n HT40 Test CH3: 2422MHz Test CH6: 2437MHz Test CH6: 2437MHz Test CH11: 2462MHz Test CH9: 2452MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 114 of 123 8. OUTPUT POWER TEST 8.1. Test Equipment Item Equipment ManufacturerModel No. Serial No. Last Cal. Cal. Interval 1. PXA Signal Analyzer Agilent N9030A MY51380221 Jun.30,191 Year 2. Power meter HP 436A 2016A07891 Oct.13,191 Year 3. Power sensor Agilent 8482B MY41090514 Oct.13,191 Year 4. Attenuator Agilent 8491B MY39269201 Oct.13,191 Year 5. RF Cable EMCI EMC102-KM-KM 3500170702 May.13,19 1 Year 8.2. Limit (FCC Part 15C 15.247 b(3)) For systems using digital modulation in the 2400—2483.5MHz, The Peak output Power shall not exceed 1W(30dBm), As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum power control level. 8.3. Test Procedure 1, Connected the EUT’s antenna port to Spectrum Analyzer. 2, Use the test method descried in ANSI C63.10 clause 11.9.2.2.2: 1) Set span to at least 1.5 times the OBW. 2) Set RBW = 1% to 5% of the OBW, not to exceed 1 MHz. 3) Set VBW ≥ [3 × RBW]. 4) Number of points in sweep ≥ [2 × span / RBW]. (This gives bin-to-bin spacing ≤ RBW / 2, so that narrowband signals are not lost between frequency bins.). 5) Sweep time = auto. 6) Detector = RMS (i.e., power averaging), if available. Otherwise, use sample detector mode. 7) If transmit duty cycle < 98%, use a sweep trigger with the level set to enable triggering only on full power pulses. The transmitter shall operate at the maximum power control level for the entire duration of every sweep. If the EUT transmits continuously (i.e., with no OFF intervals) or at duty cycle ≥ 98%, and if each transmission is entirely at the maximum power control level, then the trigger shall be set to “free run.”. 8) Trace average at least 100 traces in power averaging (rms) mode. 9) Compute power by integrating the spectrum across the OBW of the signal using the instrument’s band power measurement function, with band limits set equal to the OBW band edges. If the instrument does not have a band power function, sum the spectrum levels (in power units) at intervals equal to the RBW extending across the entire OBW of the spectrum. Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset. AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 115 of 123 8.4. Test Results EUT: Smart Signboard M/N: IAD-18001 Test date: 2019-12-04 Pressure: 102.1±1.0 kpa Humidity: 51.1±3.0% Tested by: Allen Test site: RF site Temperature:22.8±0.6 °C Test Mode CH Output power (dBm) Limit (dBm) 11b CH1 15.69 30 CH6 15.81 CH11 15.25 11g CH1 11.77 30 CH6 13.56 CH11 11.80 11n HT20 CH1 10.31 30 CH6 13.09 CH11 10.80 11n HT40 CH3 10.61 30 CH6 10.32 CH9 10.44 Conclusion:PASS AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 116 of 123 Test Mode: IEEE 802.11b Test CH1: 2412MHz Test Mode: IEEE 802.11g Test CH1: 2412MHz Test CH6: 2437MHz Test CH6: 2437MHz Test CH11: 2462MHz Test CH11: 2462MHz AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 117 of 123 Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz Test Mode: IEEE 802.11n HT40 Test CH3: 2422MHz Test CH6: 2437MHz Test CH6: 2437MHz Test CH11: 2462MHz Test CH9: 2452MHz
AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 118 of 123 9. POWER SPECTRAL DENSITY TEST 9.1. Test Equipment Item Equipment ManufacturerModel No. Serial No. Last Cal. Cal. Interval 1. PXA Signal AnalyzerAgilent N9030A MY51380221 Jun.30,19 1 Year 2. Attenuator Agilent 8491B MY39269201 Oct.13,19 1 Year 3. RF Cable EMCI EMC102-KM-K M 3500 170702 May.13,19 1 Year 9.2. Limit For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3kHz band during any time interval of continuous transmission. 9.3. Test Procedure Use the test method descried in ANSI C63.10 clause 11.10.2: a) Set analyzer center frequency to DTS channel center frequency. b) Set the span to 1.5 times the DTS bandwidth. c) Set the RBW to 3 kHz ≤ RBW ≤ 100 kHz. d) Set the VBW ≥ [3 × RBW]. e) Detector = peak. f) Sweep time = auto couple. g) Trace mode = max hold. h) Allow trace to fully stabilize. i) Use the peak marker function to determine the maximum amplitude level within the RBW. j) If measured value exceeds requirement, then reduce RBW (but no less than 3 kHz) and repeat. AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:Y9E-IAD18009 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F20013 Page 119 of 123 9.4. Test Results EUT: Smart Signboard M/N: IAD-18001 Test date: 2019-12-05 Pressure: 102.3±1.0 kpa Humidity: 53.6±3.0% Tested by: Allen Test site: RF site Temperature: 25.5±0.6 °C Test Mode CH Power density (dBm/3KHz) Limit (dBm/3KHz) 11b C…
Text truncated - open the document above for the full version.
No. 6, Kefeng Road, Science & Technology Park,Nans · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 38.11 mW |

Smart Signboard
Equipment Class
NII - Unlicensed National Information Infrastructure TXDigital Signage Media Appliance
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Smart Signboard
Equipment Class
DTS - Digital Transmission System
Digital Signage Media Appliance
Equipment Class
DTS - Digital Transmission System
Digital Signage Media Appliance
Equipment Class
DTS - Digital Transmission System