1 / 6 Helloway TM PTE-L70 In-Building Signal Booster User Manual 2 / 6 SAFTY WARNING WARNING: The human user’s body should always be separated from the antenna of the equipment by at least 25cm (10〞). Do not remove the covers during working. Do not try to repair or replace any components inside of the equipment. Alteration or abuse of the equipment or other components will void this product’s warranty, and could be dangerous to the user. PACKAGE CONTENTS sddg 1 2 1. 1x PTE-L70 Booster with N Female connectors. 2. AC Power Adaptor. 3. Screws Mounting Kits. 4. User manual (this document) INSTALLATION PROCEDURES NOTE: This wireless amplifier can be used for home, office, apartment and all other applicable area. Do not place the equipment in direct sunlight or in an area that has abrupt temperature and humidity changes. The whole Kit includes everything you need to enhance coverage within your area. Installation of the Repeater is very easy and takes minutes. Just mount the outdoor antenna and connect to the booster input connector. At the output of the Repeater connect the indoor coverage antenna then plug-in the power supply, you'll enjoy enhanced coverage service in your home or office. For best performance the external 3 / 6 aerial should be mounted in the location with the strongest signal strength. The effective coverage area of the unit depends on the input signal provided from this antenna. 1. Prepare a location. Place or Fix the equipment on a sturdy, and the surface in a well-ventilated area, makes sure that the air vents are not blocked. 2. Connect the Inside Antenna: The indoor antenna is intended for indoors use only. Remove the cap from the Amplifier connector marked with CELLULAR PHONE. Screw the indoor antenna in to the CELLULAR PHONE connector and make sure to tighten it. 3. Connect the Outside Antenna: The outdoor antenna is for outdoor use only. Select an outside mounting location. For best performance, try to keep the antenna on top of the location. The outside antenna should be located in an area with at least a 30” radius clear of obstructions, and other radiating elements. Remove the cap from the Amplifier connector marked with OUTSIDE ANTENNA. Screw the outside antenna in to the OUTSIDE ANTENNA connector and make sure to tighten it. NOTE: Keep the separation distance between the inside and outside antennas at least 20 feet apart. The outside antenna must be mounted with a separation distance of at least 3 feet from any of the other occupants or nearby persons and must not be co-located or operating in conjunction with any other antenna or amplifier. Antenna gain is 3dBi(Max.). 4. Connect the Power Cord: 1) Connect the power cord to the power connect on the top end of the amplifier marked with DC 6V, 2) connect the other end of the power cord to a grounded alternating current (AC) outlet. Also, if the Power Cord is connected to a power strip, make sure that the power strip is switched on. 3) The LED light is green, indicating that the Amplifier is ready to use. NOTE: To prevent damage to the Amplifier, before plugging in the Amplifier to a DC/AC power outlet, make sure that all of the connections (ANTENA to AMPLIFIER) to the Amplifier are tight and secure. WARNING: The input voltage for the Amplifier is 6V~24V DC. DO NOT use this Amplifier with a regular power supply that NOT range in 6V~24 V . otherwise, it will be damaged 4 / 6 and the user may also be injured. (Optional) 1. Mounting the Amplifier with Velcro: You can leave the Amplifier on top of a flat surface or use the enclosed Velcro straps to mount the Amplifier. There are two Velcro strips (hook-and-loop pairs) in the box for mounting the amplifier. Determine the location where your Amplifier will be placed. Clean the intended surface and allow it to dry. Peel the protective paper from the back of the hook sides of the Velcro. Press the adhesive side of the Velcro strips into place on the bottom of the Amplifier, one strip on each end. Wait 5 minutes for the adhesive to set before attaching the loop side of the Velcro to the hook side. The adhesive bond will reach its maximum strength after 24 hours. With both of the Velcro loop and hook pieces attached to the back of the Amplifier, peel the protective paper off of the back of the loop strips. Press the entire Amplifier into its mounting place. Wait 5 minutes for the adhesive to set. Make sure the Amplifier is firmly seated. To remove the Amplifier, rotate it across the Velcro – do not pull the Amplifier or cables. STARTING THE AMPLFIER The signal is received by the outside antenna from the cell tower, then amplified and transmitted to your phone through the inside antenna. When the phone transmits, the signal is received by the inside antenna, then amplified and transmitted to the cell tower through the outside antenna. Now you are ready to make and receive cell phone calls with powerful signal amplification! Note that it is normal for the Amplifier’s case to be warm during operation. Press any cell phone key to refresh its communication with the base station. If your signal is weak, having this Amplifier installed and operating properly will give you a large increase in the signal strength and quality. The change in the signal strength can be seen on the visual display of your cell phone, and heard on your receiver or headset. To see the difference, try operating your phone in an area that is known to have weak cell phone signals. You will be amazed at the dramatic difference the PHONETONE Signal Amplifier provides! 5 / 6 TROUBLESHOOTING AND SUPPORT During using your Amplifier, if the Amplifier interferes with your radio or other electronic device, move the Amplifier further away from those devices, you might be able to solve it yourself. If necessary,please contact your local dealer or send e-mail to our support team by the following methods: E-mail: [email protected] If you want to know about Phonetone Company and products for more inf…
Text truncated - open the document above for the full version.
Phonetone Technology (Shenzhen) Co., Ltd. Add: Room 404, Building 12, Qianlong Garden, Minzhi Street, Bao'an District, Shenzhen, China Phone: 86-013510329652 Fax: 86-755-28199993 2012-09-25 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: YYO-PTEL70 We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics Diagram - Block Diagram - Operation description - BOM List - Tune-Up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 4 1. EXTRIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 4 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 4 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 4 Fig.7 Fig.8
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Shenzhen Phonetone Technology Co. , Ltd. Product Name: Cell Phone Signal Booster Model Number: PTE- L 70 FCC ID: YYO- PTEL 70 50mm
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 3 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 3 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 3 Fig.5 Fig.6
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 5.7. MPE 5.7.1. Limit According to §1.1310 and §2.1091 MPE is calculated. F = frequency in MHz * = Plane-wave equivalent power density 5.7.2. Maximum Permissible Exposure Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG/4πR 2 S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna. Note: 1. Manufacturer declared that the maximum antenna gain is 3.0 dBi. 2. Manufacturer declared that the nearest distance between human and the EUT is 0.25m. 3. Only record worst case data. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 LTE- Downlink 746-757MHz Max Peak output Power at antenna input terminal 25.03 dBm Max Peak output Power at antenna input terminal 318.42 mW Prediction distance 25 cm Prediction frequency 752 MHz Antenna Gain(typical) 3.00 dBi Antenna Gain(numeric) 2.00 Power density at prediction frequency( S) 0.081 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.501 mW/cm 2 LTE- Uplink 776-787MHz Max Peak output Power at antenna input terminal 23.03 dBm Max Peak output Power at antenna input terminal 200.91 mW Prediction distance 25 cm Prediction frequency 782 MHz Antenna Gain(typical) 3.00 dBi Antenna Gain(numeric) 2.00 Power density at prediction frequency( S) 0.051 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.521 mW/cm 2 5.7.3 Test Results The power density level worst case at 25 cm downlink middle Channel is 0.081mW/cm², uplink middle channel is 0.051mW/cm², which is below the uncontrolled exposure limit of LTE band.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 106 RADIO TEST REPORT For Shenzhen Phonetone Technology Co., Ltd. Cell phone signal booster Model No.: PTE-L70 Prepared for : Shenzhen Phonetone Technology Co., Ltd. Address : Room 404, Building 12, Qianlong Estate, Minzhi Sub-district, Bao’an District, Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Date of receipt of test sample : September 07, 2012 Number of tested samples : 1 Serial number : Prototype Date of Test : September 07, 2012 – October 30, 2012 Date of Report : October 30, 2012 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 106 RADIO TEST REPORT FCC CFR 47 PART 27 Report Reference No. .............. : LCS120907045TF Date of Issue ................................ : October 30, 2012 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................ : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure........ : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name....................... : Shenzhen Phonetone Technology Co., Ltd. Address ........................................ : Room 404, Building 12, Qianlong Estate, Minzhi Sub-district, Bao’an District, Shenzhen, China Test Specification Standard ....................................... : FCC CFR 47 PART 2, FCC CFR 47 PART 27 Test Report Form No................. : LCSEMC-1.0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Cell phone signal booster Trade Mark .................................. : Model/ Type reference................. : PTE-L70 Ratings ......................................... : DC 6V, Rated current: 2.5A Result ......................................... : Positive Compiled by: Supervised by: Approved by: Ada Liang / File administrators Vito Cao/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 106 RADIO -- TEST REPORT Test Result: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS120907045TF October 30, 2012 Date of issue Type / Model........................... : Cell phone signal booster EUT......................................... : PTE-L70 Applicant............................... : Shenzhen Phonetone Technology Co., Ltd. Address.................................. : Room 404, Building 12, Qianlong Estate, Minzhi Sub-district, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Shenzhen Phonetone Technology Co., Ltd. Address................................... : Room 404, Building 12, Qianlong Estate, Minzhi Sub-district, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Factory................................... : Shenzhen Phonetone Technology Co., Ltd. Address................................... : Room 404, Building 12, Qianlong Estate, Minzhi Sub-district, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 106 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................................. 5 1.1. DESCRIPTION OF DEVICE (EUT) ...........................................................................................................................5 1.2. POWER SUPPLY AND LINE FILTERS....................................................................................................................... 5 1.3. DESCRIPTION OF TEST FACILITY........................................................................................................................... 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY............................................................................................ 6 1.5. MEASUREMENT UNCERTAINTY............................................................................................................................ 6 1.6. TEST ENVIRONMENT.............................................................................…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emission Measurement Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:YYO-PTEL70 Report No.: LCS120907045TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 1.2. Photo of Conducted Emission Measurement Fig.1
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 27 | 776 MHz - 787 MHz | 200.91 mW | G7D | Amp |

Cell Phone Signal Booster
Equipment Class
B2W - Part 20 Wideband Consumer Booster (CMRS)
Cell Phone Signal booster
Equipment Class
B2W - Part 20 Wideband Consumer Booster (CMRS)