Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2 Full manual and troubleshooting: braven.com/manuals GET TO KNOW YOUR BRAVEN BATTERY INDICATOR LIGHTS POWER SWITCH PAUSE- RESUME MUSIC BATTERY CHECK BUTTON PAIRING / ANSWER- END CALL BRAVEN CHARGING PORT VOLUME UP / SKIP TRACK (press and hold) EXTERNAL USB CHARGING PORT VOLUME DOWN / SKIP BACK (press and hold) 3.5 MM AUDIO-IN JACK 20% - 40% - 60% - 80% - 100% 3 ENG TURN ON & BLUETOOTH PAIRING 1. Press the Power button for 2-3 seconds to turn on your BRAVEN. Press the same button again for 2-3 seconds to turn your BRAVEN off. 2. Activate Bluetooth ® on the phone or device you are pairing with (see your device’s instruction manual for information on activating its Bluetooth ® settings). 3. Press and hold the Play Button on your BRAVEN until you hear the BRAVEN pairing sound. 4. Go to your phone or device’s Bluetooth ® settings and select “BRAVEN 850” from the list. 5. If asked for a passcode enter “0000” Your BRAVEN will remember the last 8 devices it has paired with. NOTE: If your BRAVEN does not have an active Bluetooth ® connection and is left on, it will shut itself off after 30 minutes. To restart your BRAVEN you will need to press and hold the power button for 2-3 seconds. 4 Full manual and troubleshooting: braven.com/manuals CHARGING YOUR BRAVEN • Before using your BRAVEN for the first time, charge the unit until all 5 Battery Capacity lights are solid (not flashing), indicating a full charge (typically 2 to 3 hours). • To charge your BRAVEN, plug the included USB-to-Micro-USB cable into a wall power adapter (not included) or into a powered USB port on a computer. Plug the Micro-USB connector end of the cable into the BRAVEN charging port. Your BRAVEN is designed to charge USB devices that draw from 0.3A - 1A (most cell phones & mp3 players – tablets and other 2A devices cannot be charged by your 850) using the full-sized USB port located behind the cap. To use external charging: 1. Turn your BRAVEN on. 2. Plug the USB power cable that came with your phone, mp3 player, or other mobile device into the USB port on your BRAVEN. 3. Plug the other end of the cable into your mobile device, and it will immediately begin charging. CHARGING EXTERNAL DEVICES 6 Full manual and troubleshooting: braven.com/manuals WARNINGS, CAUTIONS & LEGAL INFORMATION To reduce the risk of fire or electric shock, do not expose the BRAVEN to rain or moisture while charging. The BRAVEN should not be exposed to dripping or splashing, and objects filled with liquids, such as vases, should not be placed on or near it while being charged or charging other devices. As with any electronic products, use care not to spill liquids into any part of the product. Liquids can cause a failure and/or a fire hazard. The power supply must be used indoors only. Make no modifications to the product or accessories. Unauthorized alterations may compromise safety, regulatory compliance, and system performance, and will void the warranty. Do not place any flame sources, such as lighted candles, on or near the BRAVEN. The BRAVEN contains small parts that may be a choking hazard and is not suitable for children under age 3. Do not continue charging the battery if it does not reach full charge within the specified charging time. Overcharging may cause the battery to become hot, rupture, or ignite. If you see any heat deformation or leakage, properly dispose of the battery. Do not attempt to charge the battery in temperatures outside the range of 32°-104°F (0°-40°C). If the battery begins to leak, do not allow the liquid to come in contact with your skin or eyes. If contact has been made, wash the affected area with plenty of water and seek medical attention immediately. Do not expose the product or battery to excessive heat, including direct sunlight or fire and storage or use inside cars in hot weather, where it can be exposed to temperatures in excess of 115°F (60°C). Doing so may cause the battery and power supply to generate heat, rupture, or ignite. Using the product in this manner also may result in a loss of performance and a shortened life expectancy. Extended exposure to direct sunlight may damage the external appearance and material qualities. Do not step on, throw, or drop batteries or the power supply or device, or expose them to a strong shock. Do not pierce, crush, dent, or deform the batteries or power supply in any way. If either becomes deformed, properly dispose of it. Do not short-circuit batteries. Do not attempt to service the BRAVEN yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and will void the manufacturer’s warranty. To prevent risk of fire or electric shock, avoid overloading wall outlets, extension cords, or integral convenience receptacles. Your Bluetooth device (mobile phone, music player, tablet, laptop, etc.) must support the A2DP Bluetooth profile in order to work wirelessly with your new BRAVEN speaker. The A2DP profile is supported by most recent mobile products with built-in Bluetooth capability. Please refer to your device’s user manual for details and instruction regarding the Bluetooth profiles it supports. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 7 ENG are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmfu…
Text truncated - open the document above for the full version.
RF_160, Issue 02 Declaration of Authorization We Name: BRAVEN LC Address: 5255 N. Edgewood Drive, Ste. 275 City: Provo Country: United States Declare that: Name Representative of agent: Ms. Cathy Wang Agent Company name: Neutron Engineering, Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification of the following product(s): Product description: portable Audio Model: BRAVEN 850;BRAVEN 855s Trademark: BRAVEN on our behalf. Date: 2013-04-16 City: Provo Name: Daniel Hill Function: COO Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 10-AUG-09 RF_501, Issue 5 Page 1 of 1 Company Name: BRAVEN LC Address: 5255 N. Edgewood Drive, Ste. 275 City: Provo Country: United States To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: Z7RB8 Reference number: BRAVEN 850;BRAVEN 855s Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: 2013-04-18 Name and signature of applicant: Daniel Hill Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Model Declaration Letter We, the undersigning company Name: BRAVEN LC Address: 5255 N. Edgewood Drive, Ste. 275, Provo, Utah, United States, 84604 Hereby confirm that the following products: Product description: portable Audio Model: BRAVEN 850; BRAVEN 855s Trademark: BRAVEN That All versions of the Model RAVEN 850 and BRAVEN 855s are electrically equal and only differs in appearance due to marketing purpose. Company Name: BRAVEN LC Address: 5255 N. Edgewood Drive, Ste. 275, Provo, Utah, United States, 84604 Telephone: 8018515070 Fax No.: 8018515474 E-mail: [email protected] Signature: Name: Daniel Hill
Neutron Engineering Inc. Project No.: 1301C310 Page 2 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 3 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 4 of 13
Neutron Engineering Inc. Project No.: 1301C310 Page 5 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 6 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 7 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 8 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 9 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 10 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 11 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 12 of 13 Neutron Engineering Inc. Project No.: 1301C310 Page 13 of 13
Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 1 of 95 FCC/IC Radio Test Report FCC ID: Z7RB8 IC: 10013A-B8 This report concerns (check one): Original Grant Class II Change Issued Date : Mar. 05, 2013 Project No. : 1301C310 Equipment : portable Audio Model Name : BRAVEN 850; BRAVEN 855s Applicant : BRAVEN LC Address : 5255 North Edgewood Drive, Suite 275, Provo UT 84604, United States. Manufacturer : BRAVEN LC Address : 5255 North Edgewood Drive, Suite 275, Provo UT 84604, United States. Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Feb. 01, 2013 Date of Test: Feb. 01, 2013 ~ Mar. 04, 2013 Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 2 of 95 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 3 of 95 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 10 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 18 4.2.1 RADIATED EMISSION LIMITS 18 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 19 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS: 30MHZ - 1000MHZ 22 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 25 5 . NUMBER OF HOPPING CHANNEL 49 5.1 APPLIED PROCEDURES / LIMIT 49 5.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 49 5.1.2 TEST PROCEDURE 49 5.1.3 DEVIATION FROM STANDARD 49 5.1.4 TEST SETUP 49 5.1.5 EUT OPERATION CONDITIONS 49 5.1.6 TEST RESULTS 50 6 . AVERAGE TIME OF OCCUPANCY 52 Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 4 of 95 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 52 6.1.1 MEASUREMENT INSTRUMENTS LIST 52 6.1.2 TEST PROCEDURE 52 6.1.3 DEVIATION FROM STANDARD 52 6.1.4 TEST SETUP 53 6.1.5 EUT OPERATION CONDITIONS 53 6.1.6 TEST RESULTS 54 7 . HOPPING CHANNEL SEPARATION MEASUREMENT 66 7.1 APPLIED PROCEDURES / LIMIT 66 7.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 66 7.1.2 TEST PROCEDURE 66 7.1.3 DEVIATION FROM STANDARD 66 7.1.4 TEST SETUP 66 7.1.5 EUT OPERATION CONDITIONS 66 7.1.6 TEST RESULTS 67 8 . BANDWIDTH TEST 71 8.1 APPLIED PROCEDURES / LIMIT 71 8.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 71 8.1.2 TEST PROCEDURE 71 8.1.3 DEVIATION FROM STANDARD 71 8.1.4 TEST SETUP 71 8.1.5 EUT OPERATION CONDITIONS 71 8.1.6 TEST RESULTS 72 9 . PEAK OUTPUT POWER TEST 76 9.1 APPLIED PROCEDURES / LIMIT 76 9.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 76 9.1.2 TEST PROCEDURE 76 9.1.3 DEVIATION FROM STANDARD 76 9.1.4 TEST SETUP 76 9.1.5 EUT OPERATION CONDITIONS 76 9.1.6 TEST RESULTS 77 10 . ANTENNA CONDUCTED SPURIOUS EMISSION 81 10.1 APPLIED PROCEDURES / LIMIT 81 10.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 81 10.1.2 TEST PROCEDURE 81 10.1.3 DEVIATION FROM STANDARD 81 10.1.4 TEST SETUP 81 10.1.5 EUT OPERATION CONDITIONS 81 10.1.6 TEST RESULTS 82 11 . EUT TEST PHOTO 94 Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 5 of 95 1. CERTIFICATION Equipment : portable Audio Brand Name : BRAVEN Model Name : BRAVEN 850; BRAVEN 855s Applicant : BRAVEN LC Factory : Premium Loudspeakers (Huizhou) Co, Ltd Address : Tymphany Industrial Area, Xin Lian Village, Xin Xu Town, Hui Yang District, Hui Zhou City, Guanqdonq, China. Date of Test : Feb. 01, 2013 ~ Mar. 04, 2013 Test Item : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.247) / ANSI C63.4 : 2009 / FCC Public Notice DA 00-705, March 30, 2000. Canada RSS-210:2010 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1301C310) were obtained utilizing the test procedures, test instruments, test sites that has …
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 94 of 95 11. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FICP-1-1301C310 Page 95 of 95 Radiated Measurement Photos
No.3 Jinshagang 1st Rd, Shixia, Dalang · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.30 mW |

Braven BRV-XXL Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable wireless speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BLUETOOTH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Audio
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter