FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Plugwise B.V./
  3. ZB9-SENSE

ZB9-SENSEPlugwise Network Device

Plugwise B.V.
Plugwise Network Device - FCC ID ZB9-SENSE - Plugwise B.V.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 02, 2012
Application Purpose
Original Equipment
Date of Application
Oct 01, 2012
Equipment Note
Plugwise Network Device
Frequency Range
2405.00000000 - 2480.00000000
Company
Plugwise B.V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Declarations Compliance statement (part 15.19) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with any of the Pugwise products mentioned in the list below. FCC ID: ZB9-STICK ZB9-CIRCLE-PLUS ZB9-CIRCLE ZB9-STEALTH-PLUS ZB9-STEALTH ZB9-STEALTH-PLUS ZB9-STEALTH ZB9-SWITCH ZB9-SCAN ZB9-SENSE Plugwise user manual attestation. Version 2012.1 Product: Stick Circle+ Circle Stealth+ Stealth Sting+ Sting Switch Scan Sense

Users Manual

Sense 200.106.110211 Climate monitoring and management Manual 23 Sense Manual Thank you for buying this extension to your Plugwise system. With the Sense, you can wirelessly measure the temperature and air humidity in a room. In this way, you easily obtain insight into the climate in one or more rooms. The temperature sensor has a range of 0 to 60 ̊C; the air-humidity sensor has a range of 5 to 95% RH. You can also link switch actions to certain measurement values. This does not require the computer to be left on. This manual describes the installation of a single Sense, but the same steps can be followed if you want to install multiple Senses at the same time. Before you start • We recommend that you follow this manual carefully; it is essential to take the steps in the correct order. • To be able to use the Sense, you will require a Plugwise network consisting of at least a Stick or Stretch and a Circle+. A Plugwise network can never contain more Senses than 5 times the number of Circles. What this manual explains for the Circle also applies to the Stealth and the Sting, or a combination thereof. • Ensure that you use the latest version of Source and that your modules have the latest firmware version. You can check this by clicking the Updates button in Source. The Sense is only supported if all other modules have firmware version 2.36 (as of 13-05-2011) or later. If this is not yet the case, prior to the installation of the Sense, the other modules must first be updated. In Source, check whether the Stick and all of the modules are online. • In Source, check whether the tick at the bottom left of the screen shows that the Stick is online: • In Source, check in the tree at ‘Overviews’ to see whether all devices are online. This is indicated by grey and yellow lights: • Only insert the battery when you start to use the Sense. A Sense uses a great deal more power if it is not connected to a Plugwise network. • To use the Sense, it must be connected to a Plugwise network. The Sense can then be mounted on a wall. These steps are explained in more detail below. • Check whether all components are present. If a component is missing, please contact us as soon as possible. Contents of the package • Per Sense: 1 3,6V AA battery This manual SenseMounting plate Sens e 200 .106 .11021 1 Clima te monit oring and management Manual 45 1. Adding the Sense to your Plugwise network ÌStart Source and select Settings, Add Modules. ÌWhen you are asked to select a network, select the network to which the Sense must be added. ÌFill in the ID of the Sense. This ID is indicated on the stickers that are attached to the back. ÌClick the button with the green arrow: Next, insert the AA battery in the Sense. Note the + and - marks. ÌIf you want to install multiple Senses, add the IDs for all of the Senses to the list. The Plugwise network will then search for the Senses with the new IDs in the list. Wait until Source indicates that the Sense is online. The circle with the question mark will then change into the following icon: If the Sense is not found within several minutes, check whether the Plugwise network is operating correctly (refer to ‘Before you start’). If the Stick and the other modules are available in Source and the Sense is still not shown as being online, follow the instructions to delete the network settings under ‘Delete network settings’, see: ‘Advanced use’. ÌClick ‘Next’ and then ‘Finish’. ÌThe Sense is now connected to your network. 2. Attaching the Sense to the wall Up/Window > < Reset ÌTake the Sense to the location where it must be installed. This must be within 5 to 10 metres of a Circle. ÌCheck whether Source still indicates that the Sense is online. It can take several minutes for the network to process the new location of the Sense. ÌAttach the Sense mounting plate to the wall. The Up/ Window arrow on the inside of the mounting plate indicates the top. Ensure that the Plugwise logo on the front ends up in a horizontal position (see the corresponding figure). The optimal height of the Sense is 1.50 to 1.80 metres above the floor. In addition, the Sense must not be installed in direct sunlight, above a central heater and preferably not near a door or window. This can negatively impact the functioning of the Sense. ÌWhen the mounting plate is attached to the wall, slide the Sense from above onto the plate until you feel the Sense click into place. 3. Use Communication in the network The Sense contacts one of the Circles in your network. This Circle transmits the measurement data to the other Circles. If the Circle that the Sense tries to contact is unavailable, a connection will be made with another Circle. This can take several seconds. The time interval between two transmissions of measurement data can be specified. As standard, the Sense is set to a transmission interval of 15 minutes. The computer does not need to be switched on to be able to use the Sense. Switching and insight The Sense can be set up to send switch commands if certain temperature or air-humidity values are exceeded: an On or Off command can be sent to appliances or lighting specified in advance within the Plugwise network. While doing so, the Sense does not take into account other switching actions in the network, such as those from the Plugwise Switch or Plugwise Source. As standard, switching actions from the Sense are switched off. It is not recommended to use the Sense as a thermostat. An overview of the options for linking switching actions to the Sense in Source as well as other software functions is available in the latest Source manual. The manual is available at www.plugwise.com/manuals. 67 Removing Sense If the Sense will (temporarily) no longer be used, it can be removed from the Plugwise network. ÌStart Source and go to Settings, Devices. ÌThe list of ‘Non-assigned modules’ is displayed to the right of the screen. Right-click the Sense and then click ‘Delete’. ÌThe Sense will now be ignored by the network.…

Text truncated - open the document above for the full version.

Cover Letter(s)

TÜV Rheinland EPS B.V. Eiberkamp 10 9351VT Leek The Netherlands www.tuv.com/nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Cover letter Date June 14. 2012 Our reference .. Your reference -- Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TÜV Rheinland EPS B.V. TÜV Rheinland EPS B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. ® TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval. ACB Attn.: Mrs. M. Bosley Certification Department 6731 Whittier Avenue, Suite C110 McLean, Virginia 22101 USA Dear Mrs. Bosley, On behalf of our customer Plugwise B.V., we hereby would like to apply for a original certification for the following device: FCC ID : ZB9-SENSE Brand : Plugwise Model : Sense Description : Digital Transmission System (DTS) The following PDF files (exhibits) are electronically submitted: 1. Cover letter (this document) 2. Request or confidentiality 3. Authorization letter 4. Form 731 5. Antenna information 6. Bill of material (BOM)- Not required-Not provided 7. Block diagram 8. Circuit diagram 9. Interior photographs 10. Exterior photographs 11. Label information 12. Operational description 13. Test report in conformity with 47 CFR Part 15 14. Test setup photographs 15. User/installation manual Best regards, TÜV Rheinland EPS B.V. R .van der Meer Test Engineer

Cover Letter(s)

TÜV Rheinland EPS B.V. Eiberkamp 10 9351VT Leek The Netherlands www.tuv.com/nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Request for confidentiality Date June 14, 2012 Our reference -- Your reference -- Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TÜV Rheinland EPS B.V. TÜV Rheinland EPS B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. ® TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval. ACB Attn.: Mrs. M. Bosley Certification Department 6731 Whittier Avenue, Suite C110 McLean, Virginia 22101 USA Dear Mrs. Bosley, Pursuant to section 0.457(d)(2)(i) and Section 0.459 of the FCC rules we herewith request the following exhibits, related to this application for FCC ID: ZB9-SENSE be withheld from public inspection and to be kept confidential. The contents of these exhibits may not be disclosed to other parties than Plugwise B.V. and TÜV Rheinland EPS B.V.: 1. Circuit diagram 2. Block diagram 3. Operational description The reason for this request for confidentiality is that the information contained in the exhibits as listed above has been classified as company confidential. Disclosure of any portion of this information to other parties would cause substantial competitive harm. Best regards, TÜV Rheinland EPS B.V. R .van der Meer Test Engineer

Cover Letter(s)

TÜV Rheinland EPS B.V. Eiberkamp 10 9351VT Leek The Netherlands www.tuv.com/nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Antenna info Date August 27, 2012 Our reference -- Your reference -- Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TÜV Rheinland EPS B.V. TÜV Rheinland EPS B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. ® TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval. ACB Attn.: Mrs. M. Bosley Certification Department 6731 Whittier Avenue, Suite C110 McLean, Virginia 22101 USA Dear Mrs. Bosley, On behalf of our customer Plugwise B.V. , we hereby declare that the antenna of the following device: FCC ID: ZB9-SENSE Brand: Plugwise Model: Sense Description: Digital Transmission System (DTS) . The antenna is fixed to the PCB and part of the device. The antenna used is a chip antenna, Manufacturer:MURATA Model: ANCV12G44SAA127. Max Gain = -5.9 dBi. See for details the photographs of the interior of the device (exibit 09). Best regards, TÜV Rheinland EPS B.V. R. van der Meer Test Engineer

External Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland EPS B.V. P.O. Box 37 9350 AA Leek (NL) Eiberkamp 10 9351 VT Leek (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 Internet: www.tuv-eps.com E-mail: [email protected] Project number: 12030804_ZB9-SENSE.p02 Page 1 of 5 PHOTOGRAPHS OF THE EXTERIOR OF A DIGITAL TRANSMISSION SYSTEM BRAND PLUGWISE, MODEL SENSE FCC listed Industry Canada VCCI Registered R&TTE, LVD, EMC Notified Body : : : : 90828 2932G-2 R-1518, C-1598 1856 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-S.p02 Page 2 of 5 Description of test item Test item : Digital Transmission System (DTS) Manufacturer : Applied Micro Electronics “AME” BV Brand : Plugwise Model(s) : Sense Serial number(s) : -- Revision : n.a. Receipt date : April 20, 2012 Applicant information Applicant's representative : Mr. R. Van Rooijen Company : Plugwise B.V. Address : Wattstraat 56 Postal code : 2171TR City : Sassenheim Country : The Netherlands Telephone number : +31 252433070 Telefax number : +31 252433079 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-S.p02 Page 3 of 5 Table of contents 1 PHOTOGRAPHS OF THE EQUIPMENT. ....................................................................................................................... 4 1.1 EXTERNAL VIEW. ............................................................................................................................................................ 4 1.1.1 Front view.............................................................................................................................................................. 4 1.1.2 Rear view .............................................................................................................................................................. 5 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-S.p02 Page 4 of 5 1 Photographs of the equipment. 1.1 External view. 1.1.1 Front view Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-S.p02 Page 5 of 5 1.1.2 Rear view

ID Label/Location Info

Plugwise Sense ver. 20120614 FCC marking sticker: Position on backside: BATTERY Use only Lithium AA battery 3,6V < Reset 000D6F0000 XXX XXX 000D6F0000 XXX XXX 30 mm FCC ID: ZB9-SENSE FCC ID: ZB9-SENSE

Internal Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland EPS B.V. P.O. Box 37 9350 AA Leek (NL) Eiberkamp 10 9351 VT Leek (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 Internet: www.tuv-eps.com E-mail: [email protected] Project number: 12030804_ZB9-SENSE.p01 Page 1 of 6 PHOTOGRAPHS OF THE INTERIOR OF A DIGITAL TRANSMISSION SYSTEM BRAND PLUGWISE, MODEL SENSE FCC listed Industry Canada VCCI Registered R&TTE, LVD, EMC Notified Body : : : : 90828 2932G-2 R-1518, C-1598 1856 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-SENSE.p01 Page 2 of 6 Description of test item Test item : Digital Transmission System (DTS) Manufacturer : Applied Micro Electronics “AME” BV Brand : Plugwise Model(s) : Sense Serial number(s) : -- Revision : n.a. Receipt date : April 20, 2012 Applicant information Applicant's representative : Mr. R.van Rooijen Company : Plugwise B.V. Address : Wattstraat 56 Postal code : 2171TR City : Sassenheim Country : The Netherlands Telephone number : +31 252433070 Telefax number : +31 252433079 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-SENSE.p01 Page 3 of 6 Table of contents 1.1 OVERVIEW, OPENED EUT. ............................................................................................................................................. 4 1.2 PCB ................................................................................................................................................................................ 5 1.2.1 PCB front view ...................................................................................................................................................... 5 1.2.2 PCB rear view ...................................................................................................................................................... 6 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-SENSE.p01 Page 4 of 6 1.1 Overview, opened EUT. Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-SENSE.p01 Page 5 of 6 1.2 PCB 1.2.1 PCB front view Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission System (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804_ZB9-SENSE.p01 Page 6 of 6 1.2.2 PCB rear view Antenna

Test Report

FCC ID: ZB9-SENSE IC: N/A Test Report No.: 12030804.fcc02 Page 1 of 36 Client: Plugwise B.V. Wattstraat 56, 2171TR Sassenheim Test Item: Digital Transmission System (DTS) Plugwise System Wireless light and motion detector, ZigBee device Identification: Serial No.: ---- Project No.: 12030804 Date of Receipt: 2012-04-20 Testing Location: TÜV Rheinland EPS B.V. Eiberkamp 10 9351VT Leek Test Specification: FCC 47 CFR Part 15, Subpart C, Section 15.247 (October 1, 2010) ANSI C63.4-2009 KDB Publication No. 558074 D01: Measurement of Digital Transmission Systems Operating under Section 15.247 (January 18, 2012) Test Result: The test item passed the test specification(s). Testing Laboratory: TÜV Rheinland EPS B.V. Eiberkamp 10 9351 VT Leek Tested by: 2012-09-07 R. van der Meer / Inspector Date Name/Position Signature Reviewed by: 2012-09-07 O. Hoekstra / Reviewer Date Name/Position Signature Other Aspects: N/A Abbreviations: P(ass) = passed F(ail) = failed N/A = not applicable N/T = not tested This report shall not be reproduced, except in full, without the written permission of TÜV Rheinland EPS B.V. The test results relate only to the item(s) tested. . FCC ID: ZB9-SENSE IC: N/A Test Report No.: 12030804.fcc01 Page 2 of 36 TEST SUMMARY 5.1.1 VOLTAGE REQUIREMENTS RESULT: PASS 5.1.2 ANTENNA REQUIREMENTS RESULT: PASS 5.1.3 RESTRICTED BANDS OF OPERATION RESULT: PASS 5.2.1 CONDUCTED OUTPUT POWER RESULT: PASS 5.2.2 6DB BANDWIDTH RESULT: PASS 5.2.3 CONDUCTED SPURIOUS EMISSION RESULT: PASS 5.2.4 PEAK POWER SPECTRAL DENSITY RESULT: PASS 5.2.5 BAND EDGE CONDUCTED EMISSIONS RESULT: Pass 5.2.6 RADIATED SPURIOUS EMISSIONS OF TRANSMITTER RESULT: PASS 5.3.1 AC POWER LINE CONDUCTED EMISSION OF TRANSMITTER RESULT: Not Applicable- Battery operated device FCC ID: ZB9-SENSE IC: N/A Test Report No.: 12030804.fcc01 Page 3 of 36 Contents 1. GENERAL REMARKS ............................................................................................... 4 1.1 COMPLEMENTARY MATERIALS ................................................................................. 4 2. TEST SITES ............................................................................................................ 4 2.1 TEST FACILITIES ..................................................................................................... 4 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ...................................................... 5 2.3 MEASUREMENT UNCERTAINTY ................................................................................. 6 3. GENERAL PRODUCT INFORMATION ........................................................................... 7 3.1 PRODUCT FUNCTION AND INTENDED USE .................................................................. 7 3.2 SYSTEM DETAILS .................................................................................................... 7 3.3 CLOCK FREQUENCIES ............................................................................................. 8 3.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ................................................ 8 4. TEST SET-UP AND OPERATION MODES ..................................................................... 9 4.1 TEST METHODOLOGY .............................................................................................. 9 4.2 OPERATION MODES ................................................................................................ 9 4.3 PHYSICAL CONFIGURATION FOR TESTING ................................................................. 9 4.4 TEST SOFTWARE .................................................................................................. 10 4.5 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................... 11 5. TEST RESULTS R ADI O ....................................................................................... 13 5.1 TECHNICAL REQUIREMENTS ................................................................................... 13 5.1.1 Voltage Requirements ............................................................................................................... 13 5.1.2 Antenna Requirements .............................................................................................................. 13 5.1.3 Restricted Bands of Operation ................................................................................................... 14 5.2 CONDUCTED MEASUREMENTS AT ANTENNA PORT ................................................... 15 5.2.1 Conducted Output Power ........................................................................................................... 15 5.2.2 6dB Bandwidth ........................................................................................................................... 17 5.2.3 Conducted Spurious Emission ................................................................................................... 20 5.2.4 Peak Power Spectral Density .................................................................................................... 24 5.2.5 Band Edge Conducted Emissions ............................................................................................. 27 5.2.6 Radiated Spurious Emissions of Transmitter ............................................................................. 30 5.3 AC POWER LINE CONDUCTED MEASUREMENTS ...................................................... 35 5.3.1 AC Power Line Conducted Emission of Transmitter .................................................................. 35 6. LIST OF TABLES .................................................................................................... 36 7. LIST OF FIGURES .................................................................................................. 36 FCC ID: ZB9-SENSE IC: N/A Test Report No.: 12030804.fcc01 Page 4 of 36 1. General Remarks 1.1 Complementary Materials There is no attachment to this test report. 2. Test Sites 2.1 Test Facilities The Feder…

Text truncated - open the document above for the full version.

Test Setup Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland EPS B.V. Eiberkamp 10 9351VT Leek The Netherlands Telephone: +31 594 505005 Telefax: +31 594 504804 Internet: www.tuv.com/nl E-mail: [email protected] Project number: 12021502.p01 Page 1 of 6 PHOTOGRAPHS OF THE TESTSETUP OF A DIGITAL TRANSMISSION SYSTEM OPERATING IN THE 2G4 ISM-BAND BRAND PLUGWISE, MODEL Sense 12030804.p03 June 26, 2012 FCC listed Industry Canada VCCI Registered R&TTE, LVD, EMC Notified Body : : : : 90828 2932G-2 R-1518, C-1598 1856 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission Sytem (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804.p03 Page 2 of 6 Description of test item Test item : Digital Transmission System (DTS) Manufacturer : Applied Micro Electronics “AME” BV Brand : Plugwise Model : Sense Serial number : -- FCC ID : ZB9-SENSE IC : N.A. Applicant information Applicant's representative : Mr. R.van Rooijen Company : Plugwise B.V. Address : Wattstraat 56 Postal code : 2171TR City : Sassenheim Country : The Netherlands Telephone number : +31 252433070 Telefax number : +31 252433079 Report written by : R. van der Meer Report date : June 26, 2012 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission Sytem (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804.p03 Page 3 of 6 Table of contents 1 PHOTOGRAPHS OF THE TESTSETUP. ....................................................................................................................... 4 1.1 RADIATED EMISSIONS..................................................................................................................................................... 4 1.1.1 Radiated emissions setup .................................................................................................................................. 4 1.1.2 Radiated emissions setup detail ........................................................................................................................ 5 1.2 CONDUCTED TESTS ........................................................................................................................................................ 6 Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission Sytem (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804.p03 Page 4 of 6 1 Photographs of the testsetup. 1.1 Radiated emissions. 1.1.1 Radiated emissions setup Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission Sytem (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804.p03 Page 5 of 6 1.1.2 Radiated emissions setup detail Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: Digital Transmission Sytem (DTS) Applied Micro Electronics “AME” BV Plugwise Sense ZB9-SENSE N/A Project number: 12030804.p03 Page 6 of 6 1.2 Conducted tests

Contact Information

Applicant

Norbert Vroege(CEO)
[email protected]+31882433070Fax: +31252433079

Technical Contact

Plugwise B.V.Remy van Rooijen
[email protected]+31252433074

Wattstraat 56 · Sassenheim · Netherlands

Non-Technical Contact

Plugwise B.V.Remy van Rooijen
[email protected]+31252433074

Test Firm

TUV Rheinland Nederland B.V.Wiebe Boekema
[email protected]31-088-888-7888Fax: 31-653-162-192

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted.

Other Applications from Plugwise B.V.

Plugwise Network Device - FCC ID ZB9-SWITCH - Plugwise B.V.
ZB9-SWITCH

Plugwise Network Device

Oct 02, 2012

Equipment Class

DTS - Digital Transmission System
Plugwise Network Device - FCC ID ZB9-SCAN - Plugwise B.V.
ZB9-SCAN

Plugwise Network Device

Oct 02, 2012

Equipment Class

DTS - Digital Transmission System
Plugwise Network Device - FCC ID ZB9-STEALTH-PLUS - Plugwise B.V.
ZB9-STEALTH-PLUS

Plugwise Network Device

Oct 02, 2012

Equipment Class

DTS - Digital Transmission System
Plugwise Network Device - FCC ID ZB9-STEALTH - Plugwise B.V.
ZB9-STEALTH

Plugwise Network Device

Oct 02, 2012

Equipment Class

DTS - Digital Transmission System
Plugwise Stick - FCC ID ZB9-STICK - Plugwise B.V.
ZB9-STICK

Plugwise Stick

Aug 08, 2011

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral