
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL ITEM NO.: TI3B 1 The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of fire or electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. 2 I. Important Safety Information When using electrical appliances, basic safety precautions should always be followed including the following: 1. Read all instructions 2. Do not touch hot surfaces. Use handles or knobs. 3. To protect against electrical shock do not immerse cord, plugs, or appliance in water or other liquid. 4. Close supervision is necessary when any appliance is used by or near children. 5. Unplug from outlet when servicing. Allow to cool before putting on or taking off parts. 6. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or adjustment. 7. The use of accessory attachments not recommended by the appliance manufacturer may cause injuries. 8. Do not use outdoors, household use only. 9. Do not let cord hang over edge of table or counter, or touch hot surfaces. 10. Do not place on or near a hot gas or electric burner, or in a heated oven. 11. To disconnect, turn any control to off, then remove plug from wall outlet. 12. Do not use appliance for other than intended use. 13. A short power-supply cords to be provided to reduce the risk resulting from becoming entangled in or tripping over a longer cord. 14. Extension cords are available and may be used if care is exercised in their use. 15. If an extension cords power-supply cord is used, a) The marked electrical rating of the extension cord should be at least as great as the electrical rating of the appliance, and b) The cord should be arranged so that it will not drape over the 3 countertop or tabletop where it can be pulled on by children or tripped over unintentionally. 16. Do Not Cook on Broken Cook-Top – If cook-top should break, cleaning solutions and spillovers may penetrate the broken cook-top and create a risk of electric shock. 17. Clean Cook-Top with Caution – If a wet sponge or cloth is used to wipe spills on a hot cooking area, be careful to avoid steam burn, some cleaners can produce noxious fumes if applied to a hot surface. 18. Do not heat the pot empty or overheat it. 19. Do not place metallic objects such as knives, forks, spoons, lids, cans and aluminum foils on the top plate. 20. Allow sufficient space around the cooking area. 21. Never use the unit on low-heat-resistant materials (carpet, vinyl). 22. Do not place a sheet of paper between the pot or the pan and the unit. The paper may get burnt. 23. Be aware that the unit surface will remain hot for a short period of time. 24. Items with a magnetic field, such as: radios, televisions, automatic-banking cards and cassette tapes, can affect the unit. 25. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt modify the plug in any way. 26. Extreme caution must be used when moving an appliance containing hot oil or other hot liquids. 27. If the error code shows on the LED display, turn off or disconnect appliance from power supply. Please refer to solutions on the Error Code List. 28. There is potential interference when it is working. So please keep the device at a distance with people and some items, such as radios, televisions, automatic-banking cards and cassette tapes. This device complies with Part 18 of the FCC Rules. 4 IISPECIFICATION: z Power Rate: 1800W(Left), 1500W(Right), 3300W(Total) z Voltage:120V~60Hz z Temperature:150°F-450°F III HOW TO USE There are 2 plugs for this unit. The UPPER and LOWER LEFT ZONES are controlled by the left plug (total power is 1800W). And the RIGHT ZONE is controlled by the right plug (power is 1500W). WARING: The left and right plug must utilize two separate dedicated 15 amp breakers. There are 3 rows control panels on the glass surface, each control panel controls as below: RIGHT ZONE UPPER LEFT ZONE LOWER LEFT ZONE Control UPPER LEFT ZONE Control RIGHT ZONE Control LOWER LEFT ZONE 5 POWER-ON • Plug the power plug into a suitable outlet. • The control lamp of the POWER switch lights up and an audible signal sounds. • Now the device is in standby mode. • Place compatible ferrous metal cookware in the center of the chosen cook top element. • Now press the POWER key one second switch for to turn the induction cook top on. The control lamp of HEAT and TEMP in the display blinks and an audible signal sounds. HEAT FUNCTION • Press the Function Key HEAT once. The preset power stage "5" is selected and the device turns on. • With the + / - Keys, you can change the settings in a range from 1 to 10 level. Notice for UPPER and LOWER LEFT ZONES only : 1. If only one zone is being used and the other zone is off, the zone being used can be utilized to max level 10. 2. If the UPPER and LOWER LEFT ZONES are both being used in HEAT mode at the same time, the max setting of one zone is level 7 and the max settings of two zones combined will reach level 10. For example, if UPPER LEFT ZONE is set at level “4”, when you adjust the HEAT level of the LOWER LEFT ZONE from 6 to 7, the UPPER LEFT ZONE will automatically reduce to level “3”. 3. If one zone is using TEMP mode and the other zone is using HEAT mode, the max level of the HEAT mode is “5”. 6 TEMPERATURE FUNCTION • Press the Function Key TEMP once to …
Text truncated - open the document above for the full version.
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – Front View EUT – Rear View EUT – Top View EUT – Bottom View EUT – Left Side View EUT – Right Side View
EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information Specifications : Text is Black or white in color and is left justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Label here
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View 1 EUT – Cover off View 2 EUT – Control Pannel Main Board Top View EUT –Control Pannel Main Board Bottom View EUT – Electromagnetic Coil Main Board Top View EUT – Electromagnetic Coil Main Board Bottom View EUT – Power Main Board Top View EUT – Power Main Board Bottom View EUT – Fans View
1 2 34 ABCD 4 3 2 1 D CBA 1 2 LIN 1 2 OUT 1 2 C5 0.24uF/1200VDC R14 2.4K 12 120V N L3 350uH 12 L C6 10uF/400DC F1 15A/250VAC 21 C0N5 FAN BZ 4K +5V C14 10u/50V D1 1N4007 R3 820K 1/2W C9101 C10 104 +18V C25 104 R28 3K +5V R20 1K RK1 1.5mm*26mm C26103 R1 820K 1/2W R118.2K C7 221 C2 2J102J C17104 VDD VR1500R C1 5uF/275AC C8 221 C24104 R2722K +5V TRT 47K 123 HITE AC 1 AC 2 + 3 - 4 BG1 D25XB80 15A/800V Q1 2N3904 Q32N3906 C27104 R29 270K 1/2W D3 1N4148 D6 1N4007 R19 820K 1W R32 820K 1W Q5 SS8050 C19 4u7/450V C12 223 D8 BYV26C C20 1u/50V D7 UF4007 C23 220u/25V Vin 1 GND 2 Vout 3 U3 78L05 C29 220uF/25V C22104 +5V C11 220u/25V Z1 18V/0.5W +18V C28 220u/25V 1 32 4 T1 EE10/8.5V D9 UF4007 R30 22R R2139K +5V Guo PPG PA7 PA7 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 U2 AP8012E D4 1N4148 +5V R21K D2 1N4007 12345 CON1 PA0AN0 R92K +5V IGBT R16 2K PA0 R1539K C3 103 VDD R33 D91N4148 IGBT1 H20R1203 R630K R3847R O1 1 IN1- 2 IN1+ 3 GND 4 IN2+ 5 IN2- 6 O2 7 VCC 8 U4 LM393 R17 10K R18 10K +5V R820K R410K R2310K VDD +18V R22 47K Ω AN0 12345678 910111213141516 U1 D5IN4148 R2530K R24 10K PPG 123 CN1 IGBTH20R1203 R3730K R7 47R 12345678 A B C D 8 7654321 D C B A 1 2 3 4 CON1 TX +5V ABCDEFGDP COM2 COM1 COM0 +5V K4 K3 K2 K1 K6 K5 _ ON/OFF TEMP + RX SEG5/COM3 20 COM2/K3 1 COM3/K4 2 COM4/K5 3 COM5/K6 4 COM6/K7 5 COM7/K8 6 K9 7 K10 8 K11 9 K12 10 VSS 11 VDD 12 RX 13 SEG2/COM0 14 SEG0/164/CLK 15 SEG1/164/AB 16 SEG3/COM1 18 SEG4/COM2 19 TX 17 SEG6/COM4 21 SEG7/COM5 22 COM0/K1 23 COM1/K2 24 U1 T24A R110K +5V EC2 100uF/16V C2 104 1 2 3 4 CON2 B-RX-1 B-TX-1 +5V R210K A BC D E F G DP COM1COM2COM3COM0 SMG1 LED5LED6LED4LED3LED2LED1LED7HEA T TEMPHEA T TEMPTIMERPOWERTIMER TIMER HEAT TX RX +5V EC1 100uF/16V C1 104 1 2 3 4 CON2 B-RX-1 B-TX-1+5V R210K R3 10K U3 OPTOISO1 R6 1K U4 OPTOISO1 +5V1 R45.1K +5V 1 2 3 4 CON1 R5 5.1K +5V1 ABCDEFGDP COM2 COM1 COM0 +5V K4 K3 K2 K1 K6 K5 _ ON/OFF TEMP HEAT + SEG5/COM3 20 COM2/K3 1 COM3/K4 2 COM4/K5 3 COM5/K6 4 COM6/K7 5 COM7/K8 6 K9 7 K10 8 K11 9 K12 10 VSS 11 VDD 12 RX 13 SEG2/COM0 14 SEG0/164/CLK 15 SEG1/164/AB 16 SEG3/COM1 18 SEG4/COM2 19 TX 17 SEG6/COM4 21 SEG7/COM5 22 COM0/K1 23 COM1/K2 24 U1 T24A R11K A BC D E F G DP COM1COM2COM3COM0 SMG1 LED5LED6LED4LED3LED2LED1LED7 HEA T TEMPHEA T TEMPTIMERPOWERTIMER TIMER 1 2 3 4 CON1 TX +5V ABCDEFGDP COM2 COM1 COM0 +5V K4 K3 K2 K1 K6 K5 _ ON/OFF + RX SEG5/COM3 20 COM2/K3 1 COM3/K4 2 COM4/K5 3 COM5/K6 4 COM6/K7 5 COM7/K8 6 K9 7 K10 8 K11 9 K12 10 VSS 11 VDD 12 RX 13 SEG2/COM0 14 SEG0/164/CLK 15 SEG1/164/AB 16 SEG3/COM1 18 SEG4/COM2 19 TX 17 SEG6/COM4 21 SEG7/COM5 22 COM0/K1 23 COM1/K2 24 U1 T24A R110K +5V EC3 100uF/16V C3 104 A BC D E F G DP COM1COM2COM3COM0 SMG1 LED5LED6LED4LED3LED2LED1LED7HEA T TEMPHEA T TEMPTIMERPOWERTIMER TIMER TEMP HEAT R13 100R R11 10K R9 100R +5V +5V
Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. FCC PART 18 TEST REPORT For Fruto Industrial International Ltd. Unit 1921, 19/F, China Shine Plaza, No. 3-15 Lin H Tian He, Guangzhou, China FCC ID: ZBNTI3B Report Type: Original Report Product Type: INDUCTION COOKTOP Test Engineer: Joson Xiao Report Number: RSZ150519552-00 Report Date: 2015-07-27 Reviewed By: Sunny Sun EMC Leader Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ150519552-00 FCC Part 18 Page 2 of 14 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 TEST FACILITY ............................................................................................................................................................. 3 OPERATING CONDITION/TEST CONFIGURATION .......................................................................................... 4 JUSTIFICATION ............................................................................................................................................................. 4 EUT EXERCISE SOFTWARE .......................................................................................................................................... 4 SPECIAL ACCESSORIES ................................................................................................................................................. 4 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 4 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 4 EXTERNAL CABLE ........................................................................................................................................................ 4 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 5 SUMMARY OF TEST RESULT ................................................................................................................................. 6 FCC §18.307 - AC LINE CONDUCTED EMISSIONS .............................................................................................. 7 APPLICABLE STANDARD .............................................................................................................................................. 7 EUT SETUP .................................................................................................................................................................. 7 EMI TEST RECEIVER SETUP ......................................................................................................................................... 8 TEST PROCEDURE ........................................................................................................................................................ 8 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................................... 8 TEST RESULTS SUMMARY ............................................................................................................................................ 9 TEST DATA .................................................................................................................................................................. 9 FCC §18.305 – FIELD STRENGTH .......................................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP AND SPECTRUM ANALYZER SETUP ................................................................................ 12 TEST PROCEDURE ...................................................................................................................................................... 13 CORRECTED AMPLITUDE CALCULATION .................................................................................................................... 13 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 13 TEST DATA ................................................................................................................................................................ 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ150519552-00 FCC Part 18…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.028 MHz - 0.028 MHz | - |

Induction Cooker
Equipment Class
8CC - Part 18 Consumer Device
INDUCTION COOKER
Equipment Class
8CC - Part 18 Consumer Device
Induction cooker
Equipment Class
8CC - Part 18 Consumer Device
Induction cooker
Equipment Class
8CC - Part 18 Consumer Device
Induction cooker
Equipment Class
8CC - Part 18 Consumer Device