FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen New Element Medical Equipment Technology Development Co., Ltd./
  3. ZBSWRM-XPN

ZBSWRM-XPNREMOTE & MOBILE VOIDING DIARY MONITORING SYSTEM

Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
REMOTE & MOBILE VOIDING DIARY MONITORING SYSTEM - FCC ID ZBSWRM-XPN - Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 14, 2011
Application Purpose
Original Equipment
Date of Application
Mar 14, 2011
Equipment Note
REMOTE & MOBILE VOIDING DIARY MONITORING SYSTEM
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Table of Contents 1 BASIC INFORMATION ...................................................................................................... 4 1.1 MANUFACTURER.......................................................................................................... 4 1.2 PRODUCT..................................................................................................................... 4 1.3 R EVISION HISTORY...................................................................................................... 4 1.4 PRODUCT CLASSIFICATION........................................................................................... 5 1.5 APPLICABLE STANDARDS............................................................................................. 5 1.6 NOTES ON SAFETY....................................................................................................... 5 2 OVERVIEW.......................................................................................................................... 7 2.1 COMPONENTS............................................................................................................... 7 2.2 W ORKFLOW................................................................................................................. 8 2.3 APPLICATION................................................................................................................ 8 3 URINE COLLECTOR .......................................................................................................... 9 3.1 D ESCRIPTION............................................................................................................... 9 3.2 EXTERIOR STRUCTURE AND FUNCTIONS...................................................................... 9 3.3 BUTTONS.................................................................................................................... 12 3.4 I NDICATOR................................................................................................................. 12 3.5 BATTERY.................................................................................................................... 13 3.5.1 R EPLACING BATTERIES.................................................................................... 13 3.5.2 LOADING BATTERIES....................................................................................... 13 4 OPERATING PROCEDURE.............................................................................................. 14 4.1 URINARY DIARY MODE.............................................................................................. 14 4.1.1 ENABLING THE MODE...................................................................................... 14 4.1.2 COLLECTING URINE VOLUME.......................................................................... 14 4.2 U ROFLOMETRY MODE................................................................................................ 15 4.2.1 E NABLING THE MODE...................................................................................... 15 4.2.2 C OLLECTING UROFLOMETRY........................................................................... 15 4.3 DISABLING THE URINE COLLECTOR........................................................................... 16 2 4.4 CAUTIONS.................................................................................................................. 16 4.5 CLEANING AND MAINTAINING THE COLLECTOR......................................................... 16 5 HEALTH MOBILE PHONE .............................................................................................. 18 5.1 DISTRIBUTING DEVICE............................................................................................... 19 5.2 RECALLING DEVICE................................................................................................... 23 6 FUNCTIONS ON MOBILE PHONE................................................................................. 27 6.1 S OFTWARE INTERFACES............................................................................................. 27 6.2 FUNCTION MENU....................................................................................................... 28 6.2.1 CONFIGURATION.............................................................................................. 29 6.2.2 URINE STAT I S T I C S............................................................................................ 30 6.2.3 R EMINDING...................................................................................................... 31 6.2.4 COLLECTING.................................................................................................... 32 6.2.5 S ENDING.......................................................................................................... 33 6.2.6 LOGGING OUT................................................................................................. 34 6.2.7 EXITING SOFTWARE......................................................................................... 34 6.2.8 R EGULARLY COLLECTING AND UPLOADING.................................................... 34 6.3 RECALL...................................................................................................................... 34 6.4 V IEWING CONFIGURATION......................................................................................... 35 6.5 ABOUT METS_MOBILE .......................................................................................... 35 7 CENTER SERVER ............................................................................................................. 37 7.1 S YSTEM LOGIN........................................................................................................... 37 7.2 L OGOUT..................................................................................................................... 38 7.3 C OMMON OPERATIONS.............…

Text truncated - open the document above for the full version.

Block Diagram

1 1 2 2 3 3 4 4 DD CC BB AA CPU 32.768khz Pressure Sensor BATT A/D Rest Battery Led Key BlueTooth Module DC/DC600mA/3.3V DC/DC600mA/3.3V LIAOLIU Principle Diagram ANTENNA

Cover Letter(s)

Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN POWER OF ATTORNEY Mar.11,2011 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Mar.10,2012. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Shenzhen New Element Medical Equipment Technology Development CO.,Ltd., are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. ------------------------------- Regulatory Affairs(Julia huang)

External Photos

Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Page 50 of 53 Ref No.: WT11020560-S-E-F 17 Photographs - Constructional Details 17.1 EUT-Front View 17.2 EUT-Back View

ID Label/Location Info

Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Page 53 of 53 Ref No.: WT11020560-S-E-F 18 FCC ID Label This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Label Location FCC ID: ZBSWRM-XPN This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation

ID Label/Location Info

FCC ID Label Sample for Model: XYS.WRM-1PN;XYS.WRM-2PN FCC ID: ZBSWRM-XPN This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Page 51 of 53 Ref No.: WT11020560-S-E-F 17.3 PCB1-Front View 17.4 PCB1-Back View Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Page 52 of 53 Ref No.: WT11020560-S-E-F 17.5 PCB2-Front View 17.6 PCB2-Back View

Operational Description

Circuit Description The device is in the sleep state after battery is installed. Press Start to activate it. After that, three indicators are on at the same time. The system resets when the device is initializing. Then the device switches to the working state. The working frequency is 12 MHz. The mode indicator flashes slowly, which indicates that the device is ready for weighing. The indicator is normally on after an object is put on the measuring surface. The device switches to the sleep state automatically after the object is moved away. Then the power mode and Bluetooth indicators are off.When real-time data is required, press the forcible communication button. The Bluetooth indicator flashes. The Bluetooth device and terminal starts to communicate.

Schematics

1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 DD CC BB AA Title NumberRevisionSize A3 Date:2011-2-13Sheet of File:Sheet1.SchDocDrawn By: R5 R6 C4 C5 Y2 C3 C2 GND VCC GND VCC TXD RXD SCKMISO UART_PW GND L1 C6 C7 1 2 Y1 VCC2 1 X1 2 X2 3 GND 4 RST 5 DATA 6 CLK 7 VCC1 8 U2 VCC RTC_RST RTC_SDA BAT1 RTC_RST GND GND R12 VCC COMM_LED R13 WEIGHT_LED CAL_KEY COMM_KEY MOD_KEY R11 R10 R9 GND VCC R1 UART_VDD UART_VDD RXD TXD RST_UART R2 SENS_PW E1 C1 SENS_PW COMM_LEDWEIGHT_LEDPW_LED PW_LED R8R24 C8 R7 VCC VCC GND C2D GND C2CLK GND MOSI VCC MISO SCK CS CS MOSI R15R14 VCC BEEP BEEP R16 R17 VCC GND GND R18 D1D2 E2 GND SI 1 SCK 2 RESET 3 CS 4 WP 5 VCC 6 GND 7 SO 8 U5 1 2 J1 1 2 3 4 J2 GND UART-TX 1 UART-RX 2 UART-CTS 3 UART-RTS 4 PCM-CLK 5 PCM-OUT 6 PCM-IN 7 PCM-SYNC 8 AIO(0) 9 AIO(1) 10 RESET 11 3.3V 12 GND 13 GND 14 USB D- 15 SPI-CSB 16 SPI-MOSI 17 SPI-MISO 18 SPI-CLK 19 USB D+ 20 GND 21 GND 22 PIO0 23 PIO1 24 PIO2 25 PIO3 26 PIO4 27 PIO5 28 PIO6 29 PIO7 30 PIO8 31 PIO9 32 PIO10 33 PIO11 34 蓝牙串口樑块 U3 UART_VDD R25 C12 GND GNDGND GND AGND 9 AV+ 10 AIN0.0 1 AIN0.1 2 AIN0.2 3 AIN0.3 4 P2.0/C2D 11 RES/C2CLK 12 P0.0 13 P0.1 14 P0.2/XTAL1 15 P0.3XTAL2 16 P0.4 17 P0.5 18 P0.6 19 P0.7 20 VDD 21 DGND 22 P1.0 23 P1.1 24 P1.2 25 P1.3 26 P1.4 27 P1.5 28 P1.6/IDA0 29 P1.7/IDA1 30 VREF+ 31 VREF- 32 C8051F350/2 AIN0.4 5 AIN0.5 6 AIN0.6 7 AIN0.7 8 U1 R26 CS MOSI MISO CLK R21 R22R23 UART_PW RTC_SCK D4 D5 D6 R31R32R33 VCC INT 4 56 U4B 1 23 U4A 1112 13 U4D 89 10 U4C key interrupt S2 S3 S4 RTC_SDA RTC_SCK R35 VCC R34 VCC RTC_SCK D3 R28 R29 R30 VCC GND R27 VCC S1 D7 R36 E 2 C 3 B 1 Q1 Q2 GNDUART_VDD A 1 A1 C10 IND1 1 1 2 2 C11 RXD TXD RST_UART GND 1 AIO0 2 AIO1 3 AIO3 4 SPK-P-L 5 SPK-N-L 6 SPK-P-R 7 SPK-N-R 8 MIC-N-R 9 MIC-P-R 10 MIC-N-L 11 MIC-P-L 12 GND 13 3V3 14 USB-D+ 15 USB-D- 16 UART-RX 17 UART-TX 18 PCM-IN 19 PCM-SYNC 20 PCM-CLK 21 PCM-OUT 22 PIO6 23 GND 24 PIO5 25 PIO4 26 PIO7 27 PIO11 28 PIO10 29 PIO9 30 PIO3 31 PIO2 32 PIO8 33 PIO1 34 PIO0 35 MFC 36 GND 37 GND 38 RF 39 GND 40 GND 41 RESET 42 SPI_MISO 43 SPI_CLK 44 SPI_CS 45 SPI_MOSI 46 U6 BLUE_IND B 1 C 3 E 2 Q3 Q4 CFG 6*6*5 6*6*5 6*6*5 6*6*6.5 B3F-1022 R3 R4 SI 1 SCK 2 RESET 3 CS 4 WP 5 VCC 6 GND 7 SO 8 U7 Jun Wu 11.0 1 WRM-2PN

Test Report

FCC TEST REPORT Waltek Services Ref No.: WT11020560-S-E-F Page 1 of 49 FCC ID : ZBSWRM-XPN Applicant : Shenzhen New Element Medical Equipment Technology Development CO.,Ltd Adress of Applicant : 4F,Building 422,Bagua 4th Road,Futian District,Shenzhen,China Equipment Under Test (EUT) : Product description : Remote & Mobile Voiding Diary Monitoring System Model No. : XYS.WRM-1PN;XYS.WRM-2PN Standards : FCC 15 Subpart C Paragraph 15.247 Date of Test : Mar.09,2011 Test Engineer : Olic Huang /Engineer Reviewed By : Philo Zhong /Manager PERPARED BY: Waltek Services (Shenzhen) Co., Ltd. 1/F, Fukangtai Building,West Baima Rd.,Songgang Street, Baoan District, Shenzhen 518105,China Tel: +86-755-27553488 Fax: +86-755-27553868 Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Waltek Services Ref No.: WT11020560-S-E-F Page 2 of 49 2 Contents Page 1 COVER PAGE..........................................................................................................................................................1 2 CONTENTS ..............................................................................................................................................................2 3 TEST SUMMARY....................................................................................................................................................4 4 GENERAL INFORMATION..................................................................................................................................5 4.1 CLIENT INFORMATION............................................................................................................................................5 4.2 GENERAL DESCRIPTION OF E.U.T...........................................................................................................................5 4.3 DETAILS OF E.U.T. .................................................................................................................................................5 4.4 DESCRIPTION OF SUPPORT UNITS...........................................................................................................................5 4.5 STANDARDS APPLICABLE FOR TESTING..................................................................................................................5 4.6 TEST FACILITY........................................................................................................................................................6 4.7 TEST LOCATION......................................................................................................................................................6 5 EQUIPMENT USED DURING TEST ...................................................................................................................7 6 CONDUCTED EMISSION TEST ........................................................................................................................10 6.1 TEST EQUIPMENT..................................................................................................................................................10 6.2 TEST PROCEDURE.................................................................................................................................................10 6.3 CONDUCTED TEST SETUP.....................................................................................................................................11 6.4 EUT OPERATING CONDITION...............................................................................................................................11 6.5 CONDUCTED EMISSION LIMITS.............................................................................................................................12 6.6 CONDUCTED EMISSION TEST DATA......................................................................................................................12 7 RADIATION EMISSION TEST...........................................................................................................................13 7.1 TEST EQUIPMENT..................................................................................................................................................13 7.2 MEASUREMENT UNCERTAINTY.............................................................................................................................13 7.3 TEST PROCEDURE.................................................................................................................................................13 7.4 RADIATED TEST SETUP.........................................................................................................................................14 7.5 SPECTRUM ANALYZER SETUP...............................................................................................................................14 7.6 CORRECTED AMPLITUDE & MARGIN CALCULATION............................................................................................15 7.7 SUMMARY OF TEST RESULTS................................................................................................................................15 7.8 EUT OPERATING CONDITION...............................................................................................................................16 7.9 RADIATED EMISSIONS LIMIT.................................................................................................................................16 7.10 RADIATED EMISSIONS TEST RESULT................................................................................................................17 7.11 TEST CONDITION..............................................................................................................................................17 7.12 RADIATED EMISSION DATA.............................................................................................................................18 7.12.1 Test mode: cont…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen New Element Medical Equipment Technology Development CO.,Ltd. FCC ID: ZBSWRM-XPN Page 49 of 53 Ref No.: WT11020560-S-E-F 16 Photographs of Testing Radiation Emission Test View For 30MHz-1000MHz Radiation Emission Test View For 1GHz-25GHz

Contact Information

Applicant

Julia Huang(Regulatory Affairs)
[email protected](86) 755-82445959Fax: (86) 755-82443286

Test Firm

Waltek Services(Shenzhen) Co., Ltd.Philo zhong
[email protected]0086-755-27553488Fax: 0086-755-27553868

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.00 mW
Grant Notes
Power listed is conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Shenzhen New Element Medical Equipment Technology Development Co., Ltd.

REMOTE & MOBILE BLOOD GLUCOSE MONITORING AND DIABETES PATIENT FOLLOW-UP SYSTEM - FCC ID ZBSPFES-1TNB - Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
ZBSPFES-1TNB

REMOTE & MOBILE BLOOD GLUCOSE MONITORING AND DIABETES PATIENT FOLLOW-UP SYSTEM

Apr 17, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
REMOTE & MOBILE AMBULATORY BLOOD PRESSURE MONITORING SYSTEM - FCC ID ZBSWRM-1XY - Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
ZBSWRM-1XY

REMOTE & MOBILE AMBULATORY BLOOD PRESSURE MONITORING SYSTEM

Mar 15, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
REMOTE & MOBILE ECG MONITORING SYSTEM - FCC ID ZBSWRM-XE - Shenzhen New Element Medical Equipment Technology Development Co., Ltd.
ZBSWRM-XE

REMOTE & MOBILE ECG MONITORING SYSTEM

Mar 14, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter