FUJIAN NAN'AN BAOFENG ELECTRONICS CO.,LTD. 2/F.,No.1Bldg.,Boyi Industrial Garden,4 th Gongye Rd.Zhicun Dashi Street,Panyu Dis.,Guangzhou,China TEL: (86) 020-34796226 FAX: (86) 020-34796116 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. { FUJIAN NAN'AN BAOFENG ELECTRONICS CO.,LTD.} would like the following documents regarding this submission for FCC ID: ZP5BF-5R to be kept confidential. 1ใ Schematics 2ใ Operational Description 3ใ Block Diagram 4ใ Tune Up Procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, FUJIAN NAN'AN BAOFENG ELECTRONICS CO.,LTD.
FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. CHANGFU INDUSTRIAL ZONE, XIAMEI, NNAโAN, QUANZHOU, FUJIAN, CHINA TEL: 00886-595-86767889 FAX: 00886-595-86753889 Declaration Date: 09 April 2011 Federal Communications Commissions Authorization & Evaluation Division 7435 Oakland Mills Road Colombia, MD 21046 Product Name: Two Way Radio Model: UV-5R FCC ID: ZP5BF-5R Dear whom may be concerned: We declare this equipment meets the requirements of FCC Rules, Parts 90.203 (e) and (g) as applicable. Programming of this product's transmit frequencies can be performed ONLY by the manufacturer or by service or maintenance personnel. The operator cannot program transmit frequencies using the equipment's external operation. We also declare that the device will not be marketed to USA users with the frequency band Which is not allowed by rule part 90. It will be a violation of FCC rules if this device is operated on unauthorized frequencies inside the USA. Sincerely,
Outside View Outside View Outside View Outside View Outside View Li-ion Battery Charger: Adapter:
Distance between device and user body The distance between device and user body at less 1.50 cm
Distance between antenna and user body The distance between antenna and user body at lest 1.50 cm
FCC ID Label Location
Interior View Interior View Interior View
ISO/IEC17025Accredited Lab. Report No: FCC 1203056 File reference No: 2012-04-25 Applicant: FUJIAN NANโAN BAOFENG ELECTRONICS CO., LTD Product: Two Way Radio Model No: UV-5R Trademark: BAOFENG Test Standards: FCC Part 90 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4 and FCC Part 90, regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: April 25, 2012 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO., LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688 Fax (755) 83442996 Report No: 1203056 Page 2 of 74 Date: 2012-04-25 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement๏ผ The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC- Registration No.: IC5205A-01 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-01. Report No: 1203056 Page 3 of 74 Date: 2012-04-25 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration.................................................................................................... 4 1.6 Test Uncertainty.................................................................................................5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 5 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 6.0 Frequency Tolerance..........................................................................................12 7.0 Emission Bandwidth and Mask............................................................................. 17 8.0 Unwanted Radiation.......................................................................................... 37 9.0 Modulation Characteristics................................................................................... 44 10.0 Maximumโฆ
Text truncated - open the document above for the full version.
15.1 Conducted test View-- 15.2 Radiated emission test view Spurious Radiated Emissions test View-- Spurious Radiated Emissions test View--
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 9 | 406.1 MHz - 480 MHz | 1.78 W | 9K20F3E | 1.81 ppm |

Walkie Talkie
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Walkie Talkie
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Dual Band Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face