Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SAFETY TRAINING INFORMATION Your FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. radio generators RF electromagnetic energy during transmit mode. This radio is designed for and classified as͞KĐĐƵƉĂƚŝŽŶĂůUseKŶůLJ͕͟meaning it must be used only during the course of employment by individuals aware of the hazards, and the ways to minimize such hazards. This radio is NOT intended for use by the͞'ĞŶĞƌĂůWŽƉƵůĂƚŝŽŶ͟in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure limits for͞KĐĐƵƉĂƚŝŽŶĂůUseKŶůLJ͘͟Inaddition , your FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans: ᪽ FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ᪽American National Standards Institute (C95.1-1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. ᪽American National Standards Institute (C95.3-1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields±RF and Microwave. ᪽The following accessories are authorized for use with this product. Use of accessories other than those (listed in the instruction) specified may result in RF exposure levels exceed the FCC requirements for wireless RF exposure. To ensureLJŽƵ͛ƌĞLJŽƵƌexpose to RF electromagnetic energy is within the FCC allowable limits for occupational use, always adhere to the following guidelines: ᪽ DO NOToperate the radio without a proper antenna attached, as this may damaged the radio and may also cause you to exceed FCC RF exposure limits. A proper antenna is the antenna supplied with this radio by the manufacturer or antenna specifically authorized by the manufacturer for use with this radio. ᪽DO NOTWUDQVPLWVIRUPRUHWKDQRIWRWDOUDGLRXVHWLPH ³GXW\F\FOH ́ 7UDQVPLWWLQJPRUHWKDQRIWKH time can cause FCC RF exposure compliance requLUHPHQWVWREHH[FHHGHG7KHUDGLRLVWUDQVPLWWLQJZKHQWKH³7;LQGLFDWRU ́OLJKWVUHG <RXFDQFDXVHWKHUDGLRWRWUDQVPLWE\SUHVVLQJWKH³377 ́VZLWFK ᪽ALWAYSkeep the antenna at least 2.5 cm (1 inch) away from the body when transmitting and only use the belt-clip which is listed in instructions when attaching the radio to your belt, etc., to ensure FCC RF exposure compliance requirement s are not exceeded. To provide the recipients of your transmission the best sound quality, hold the antenna at least 5 cm (2 inches) from your mouth, and slightly off to one side. T he information listed above provides the user with the information needed to make him or her aware of RF exposure, andwhattodotoasͲsure that this radio operates with the FCC RF exposure limits of this radio. Electromagnetic Interference/Compatibility During transmissions, your FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. radio generates RF energy that can possibly cause interference with other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so.DO NOToperate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, aircraft, and blasting sites. Occupational/Controlled Use The radio transmitter is used in situations in which persons are exposed as consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Note: This product could program the frequence on computer through interface by manufacturer, the end user could use it for charging only.
Dec. 20, 2013 Federal Communication Commission Authorization and Evaluation Division FCC ID: ZP5UV-B5 Re: Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the applicant hereby requests confidential treatment of information applied this application as outlined below: 1: Block Diagram 2: Circuit Diagram 3: Operational Description 4: Parts List 5: Turn Up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rules 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Contact person: SHAOFENG WANG Title: Manager
Jan.08, 2014 Federal Communication Commission Authorization and Evaluation Division Subject: FCC ID: ZP5UV-B5 Justification Letter for Expanded Frequency Range 136MHz- 174MHz and 400MHz- 470MHz Gentlemen; We, FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. for justification to expanded the freq range to 136MHz- 174MHz and 400MHz- 470MHz. And when the products put into the US market, we make sure it will comply with all relative rule parts of FCC. Sincerely, FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Shaofeng Wang/Manager
FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. CHANGFU INDUSTRIAL ZONE, XIAMEI,NAN’AN, QUANZHOU, FUJIAN, CHINA Date: Dec. 20 , 2013 Statement We, FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. states that our device, FCC ID: ZP5UV-B5, has no space to put the label except the battery compartment of this device. It is visible to the users as they purchase the products and install the battery. Regards Company: FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Contact Person: SHAOFENG WANG Title: Manager
External Photos WHOLE VIEW OF EUT TOP VIEW OF EUT BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT
FCC ID Label Location FCC RF Warning Label Walkie Talkie FCC ID: ZP5UV-B5 Model : UV-B5 Frequency Range:136MHz to 174MHz,400MHz to 470MHz
Internal Photos OPEN VIEW OF EUT INTERNAL VIEW‐1 OF EUT INTERNAL VIEW‐2 OF EUT INTERNAL VIEW‐3 OF EUT INTERNAL VIEW‐4 OF EUT
Report No.:AGC01303131102FH01 Page 1 of 94 SAR Test Report Report No.: AGC01303131102FH01 FCC ID : ZP5UV-B5 APPLICATION PURPOSE : Original Equipment Product Designation : Walkie Talkie Brand Name : BAOFENG Model Name : UV-B5 Client : FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Date of Issue : Dec.02,2013 STANDARD(S) : IEEE Std. 1528:2003 47CFR § 2.1093 IEEE/ANSI C95.1 REPORT VERSION : V1.01 Attestation of Global Compliance(Shenzhen) Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.:AGC01303131102FH01 Page 2 of 94 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.01 / Dec.02,2013 Valid Original Report Report No.:AGC01303131102FH01 Page 3 of 94 Test Report Certification Applicant Name FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Applicant Address CHANGFU INDUSTRIAL ZONE, XIAMEI,NAN’AN, QUANZHOU, FUJIAN, CHINA Manufacturer Name FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. Manufacturer Address CHANGFU INDUSTRIAL ZONE,XIAMEI, NAN’AN,QUANZHOU, FUJIAN, CHINA Product Name Walkie Talkie Brand Name BAOFENG Model Name UV-B5 Difference Description N/A Applicable Standard IEEE Std. 1528:2003 47CFR § 2.1093 IEEE/ANSI C95.1 Test Date Nov.29, 2013 Performed Location Attestation of Global Compliance (Shenzhen)Co., Ltd. 2F, Building 2, No.1-No.4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang Street, Bao'an District, Shenzhen, China Report Template AGCRT-EC-PPT/SAR (2013-03-01) Tested By Eric Zhou Dec.02,2013 Checked By Angela Li Dec.02,2013 Authorized By Solger Zhang Dec.02,2013 Report No.:AGC01303131102FH01 Page 4 of 94 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ......................................................................................................... 5 2. GENERAL INFORMATION .............................................................................................................................. 6 2.1. EUT Description ....................................................................................................................................... 6 2.2. Test Procedure ......................................................................................................................................... 7 2.3. Test Environment ..................................................................................................................................... 7 3. SAR MEASUREMENT SYSTEM........................................................................................................................ 8 3.1. Specific Absorption Rate (SAR)................................................................................................................ 8 3.2. SAR Measurement Procedure ................................................................................................................. 9 3.3. COMOSAR System Description ............................................................................................................. 10 3.4. COMOSAR E-Field Probe ...................................................................................................................... 12 3.5. Isotropic E-Field Probe Specification ...................................................................................................... 12 3.6 Robot ...................................................................................................................................................... 13 3.7. Video Positioning System ....................................................................................................................... 13 3.8. Device Holder ........................................................................................................................................ 14 3.9. Elliptic Phantom ..................................................................................................................................... 14 4. TISSUE SIMULATING LIQUID ....................................................................................................................... 15 4.1. The composition of the tissue simulating liquid ....................................................................................... 15 4.2. Tissue Calibration Result ........................................................................................................................ 16 4.3. Tissue Dielectric Parameters for Head and Body Phantoms .................................................................. 17 5. SAR MEASUREMENT PROCEDURE ............................................................................................................ 18 5.1. SAR System Validation Procedures ....................................................................................................... 18 5.2. SAR System Validation .......................................................................................................................... 19 6. EUT TEST POSITION ...................................................................................................................................... 21 6.1. Body Worn Position ................................................................................................................................ 21 7. SAR EXPOSURE LIMITS ............................................................................................................................... 22 8. TEST EQUIPMENT LIST ................................................................................................................................ 23 9. MEASUREMENT UNCERTAINTY .................................................................................................................. 24 10. CONDUCTED POWER MEASUREMENT ..................................................................................................... 25 11. TEST RESULTS .....................................................…
Text truncated - open the document above for the full version.
Report No.: AGC01303131102FE02 Page 1 of 61 FCC Part 90 Test Report Report No.: AGC01303131102FE02 FCC ID : ZP5UV-B5 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Walkie Talkie BRAND NAME : BAOFENG MODEL NAME : UV-B5 CLIENT : FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. DATE OF ISSUE : Dec.02, 2013 STANDARD(S) : FCC Part 90 Rules REPORT VERSION : V 1.01 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC01303131102FE02 Page 2 of 61 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.01 / Dec.02, 2013 Valid Original Report Report No.: AGC01303131102FE02 Page 3 of 61 VERIFICATION OF COMPLIANCE Applicant: FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. CHANGFU INDUSTRIAL ZONE, XIAMEI, NAN’AN, QUANZHOU, FUJIAN, CHINA Manufacturer: FUJIAN NAN'AN BAOFENG ELECTRONICS CO., LTD. CHANGFU INDUSTRIAL ZONE, XIAMEI, NAN’AN,QUANZHOU, FUJIAN, CHINA Product Description: Walkie Talkie Brand Name: BAOFENG Model Name: UV-B5 Date of Test: Nov.24, 2013 to Nov.29, 2013 We hereby certify that: The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C 63.4:2003 and TIA/EIA 603. The sample tested as described in this report is in compliance with the FCC Rules Part 90 requirements. The test results of this report relate only to the tested sample identified in this report. Prepared By Wall Huang Dec.02, 2013 Checked By Kidd Yang Dec.02, 2013 Authorized By Solger Zhang Dec.02, 2013 Report No.: AGC01303131102FE02 Page 4 of 61 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................... 6 1.1 PRODUCT DESCRIPTION ................................................................................................................ 6 1.3 TEST METHODOLOGY .................................................................................................................... 7 1.4 TEST FACILITY ................................................................................................................................. 7 1.5 SPECIAL ACCESSORIES ................................................................................................................. 7 1.6 EQUIPMENT MODIFICATIONS ........................................................................................................ 7 2. SYSTEM TEST CONFIGURATION ........................................................................................................ 8 2.1 EUT CONFIGURATION ..................................................................................................................... 8 2.2 EUT EXERCISE ................................................................................................................................ 8 2.3 GENERAL TECHNICAL REQUIREMENTS ...................................................................................... 8 2.4 CONFIGURATION OF TESTED SYSTEM ...................................................................................... 8 3. SUMMARY OF TEST RESULTS ............................................................................................................ 9 4. DESCRIPTION OF TEST MODES ....................................................................................................... 10 5. CONDUCTED LIMITS .......................................................................................................................... 11 5.1 PROVISIONS APPLICABLE ........................................................................................................... 11 5.2 MEASUREMENT PROCEDURE .................................................................................................... 11 5.3 TEST SETUP BLOCK DIAGRAM ................................................................................................... 12 5.4 TEST EQUIPMENT USED .............................................................................................................. 12 5.5 TEST RESULT ................................................................................................................................. 13 6. FREQUENCY TOLERANCE ................................................................................................................ 15 6.1 PROVISIONS APPLICABLE ........................................................................................................... 15 6.2 MEASUREMENT PROCEDURE .................................................................................................... 15 6.3 TEST SETUP BLOCK DIAGRAM .................................................................................................... 16 6.4 TEST EQUIPMENT USED:.............................................................................................................. 16 6.5 TEST RESULT ................................................................................................................................. 16 7. EMISSION BANDWIDTH ..................................................................................................................... 23 7.1 PROVISIONS APPLICABLE ........................................................................................................... 23 7.2 MEASUREMENT PROCEDURE .................................................................................................... 23 7.3 TEST SETUP BLOCK DIAGRAM ................................................................................................... 23 7.4 MEASUREMENT EQUIPMENT USED: .......................................................................................... 23 7.5 MEASUREMENT RESULT: ..........................…
Text truncated - open the document above for the full version.
Te s t Setup Photos RADIATED TEST SETUP
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 9 | 406.1 MHz - 470 MHz | 4.96 W | 10K4F3E | 0.91 ppm |

Walkie Talkie
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Dual Band Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Two Way Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face