FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CUB ELECPARTS INC/
  3. ZPNTPM208

ZPNTPM208TPMS TRK 2.4G Orb Sensor (

CUB ELECPARTS INC
TPMS TRK 2.4G Orb Sensor ( - FCC ID ZPNTPM208 - CUB ELECPARTS INC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 24, 2025
Application Purpose
Original Equipment
Equipment Note
TPMS TRK 2.4G Orb Sensor (
Frequency Range
2402.00000000 - 2480.00000000
Company
CUB ELECPARTS INC
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model:TPM208 Series:B121-068 TPMS TRK 2.4G Orb Sensor Caution: 1. The TPMS Sensor is designed to be used in commercial truck and bus, over 3.5 tons, with tubeless tires or trailer/Class A or C motorhome. 2. The sensor is NOT intended to be used where vehicle speed exceeds 120 km/h (75 mph) Installation: 1. Dismount the tire from the rim. If applicable, take out any existing TPMS sensors 2. Make sure the Retrofit Receiver already learned the ball sensor ID. Please refer to the receiver user manual to know the learning procedure. If the procedure needs the wheel position Number, please use the Cub Truck tool to program the correct wheel position ID to the sensor (keep any other sensors at least 5 meters away from the tool), then throw it into the corresponding tire. Please check the user manual of the product kit to know the relationship between wheel ID and tire location for different types of vehicles. 3. Clean the surface of the wheel near the valve stem with an isopropyl alcohol and allow it to dry completely. Write the wheel position ID with a paint marker pen on the TPMS sticker label included with the ball sensor. Adhere the sticker to the clean surface near the valve stem. This will serve as an indicator that a sensor is present in the wheel and of the wheel position ID. CE Compliance Notice All CE marked Truck TPMS Sensor products are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the Declaration of Conformance will be provided upon request. FCC Statement FCC ID:ZPNTPM208 FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. User Guide of Cub Orb TPMS Sensor If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and a human body. ISED Statement HVIN:TPM208 IC ID:9959A-TPM208 This device contains licence-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, (2) this device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and a human body. L’émetteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et un corps humain. Warranty CUB warrants that the TPMS sensor shall be free from defects in workmanship and material during warranty period. CUB does not assume any liability in case of faulty, incorrect installation of the product, or by using other products causing TPMS sensor malfunction on the part of customer or user. And the agent or importer or seller will fully handle the problem of local sales and maintenance. CUB ELECPARTS INC NO.6, LANE 546, SEC.6, CHANGLU RD., FUHSIN TOWNSHIP, CHANGHUA COUNTY 50648, TAIWAN http://www.cubelec.com.tw October 2025 Model:TPM208 Series:B121-068 TPMS TRK 2.4G Orb Sensor 注意事項: 1. TPMS 感測器設計用於 商用卡車與巴士(總重超過 3.5 噸),並需搭配 無內胎輪胎,亦可使用於 拖車 / A 或 C 類房車。 2. 本感測器不適用於車速超過 120 公里/小時(75 英里/小時)的情況。 安裝步驟: 1. 拆卸輪胎與移除既有感測器 將輪胎從輪圈上拆卸下來,如輪胎內已有其他 TPMS 感測器,請一併取出並妥善處理。 2. 感測器 ID 學習與輪位設定 確認接收器已成功學習球型感測器的 ID,請參閱接收器使用手冊,依照「感測器 ID 學習」程序進 行操作,若學習程序需要輸入 輪位編號(Wheel Position Number),請依下列方式操作:使用 C ub Truck 工具 將正確的輪位 ID 寫入感測器,進行設定時,請確保其他感測器距離工具至少 5 公尺 ,避免干擾,完成設定後,將感測器投入對應的輪胎,不同車型的輪位 ID 與輪胎位置對應方式, 請參閱產品套件使用手冊內的對照圖表。 3. 輪圈標示與貼紙黏貼 使用 異丙醇(Isopropyl Alcohol) 清潔氣嘴(Valve Stem)附近的輪圈表面,並完全乾燥,使用 油性記號筆在隨附的 TPMS 感測器貼紙 上標註對應的輪位 ID,將貼紙黏貼於剛清潔乾淨的氣嘴附 近位置,此貼紙可作為該輪已安裝感測器及輪位 ID 的標示,方便後續維護與識別。 CE 宣告 所有帶有CE標誌的Truck TPMS Sensor產品均符合基本要求以及指令 2014/53/EU 的其他相關規定。 NCC 「取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率、加 大功率或變更原設計之特性及功能。低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經 發現有干擾現象時,…

Text truncated - open the document above for the full version.

Attestation Statements

Attestation Statements Not Covered Entity Applicant Date: October 20, 2025 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: ZPNTPM208 CUB ELECPARTS INC. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature June Wu / Administrator Address: No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, 506,Taiwan Tel.: +886-4-7782010 Email: [email protected]

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: October 28, 2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: ZPNTPM208 CUB ELECPARTS INC. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. CUB ELECPARTS INC. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Printed Name: June Wu Title: Administrator Address: No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, 506,Taiwan Tel.: +886-4-7782010 Email: [email protected]

Attestation Statements

Certification Designating a US Agent for Service of Process Date: October 20, 2025 To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: ZPNTPM208 CUB ELECPARTS INC. (“the applicant”) certifies that as of the date of the filing of the application, FCC US Agent, LLC (“the agent”) is our designated U.S. agent. We acknowledge the applicant’s consent and the designated agent for service of process’s obligation to accept service of process. The applicant accepts to maintain an agent for service of process for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. APPLICANT Company Name: CUB ELECPARTS INC. Contact Person: June Wu Address: No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, 506, Taiwan Tel.: +886-4-7782010 Email: [email protected] FCC FRN: 0020982906 U.S. Agent Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely yours, The Applicant The Agent Company Name CUB ELECPARTS INC. FCC US Agent, LLC Contact Person June Wu Tim Payne Signature

Cover Letter(s)

TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Authority to Act as Agent Date: February 14, 2025 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA To Whom It May Concern: I appoint TÜV Rheinland Taiwan Ltd., Ivan Hsieh to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with CUB ELECPARTS INC., No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, 506, Taiwan. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: February 14, 2025 Agreement is valid for 12 months from the above date. By: __________________________ June Wu (Signature) (Print name) Administrator +886-4-7782010 (Title) (Telephone) On behalf of: CUB ELECPARTS INC. (Company Name)

Cover Letter(s)

TCB FCC Request for Confidentiality Letter Number: MS-0044715 Revision: 1 Effective date: Sep 12, 2022 Author: William Graff Owner: William Graff MS-0044715 Page 1 of 1 Revision 1 Date: October 20, 2025 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: ZPNTPM208 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction CUB ELECPARTS INC. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of specify number of days not to exceed 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _________________________________ June Wu / Administrator (Signature/Title) (Print name) Tel: +886-4-7782010 Email: [email protected]

External Photos

Appendix EP Photographs of EUT Page 1 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 2 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 3 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208

ID Label/Location Info

CDE " )NI S H! Vd)]l] Bn:>.:10 NOISSl�l:l]d 1:1011:ld lnOHllM Al l:!Vd a1:11H ANV 01 ' H! Vd NI 1:10 ]lOHM NI `o]SOl)S I a ]8 lON llVHS A]Hl . :)NI Sll:!Vd:)]l] Bn:>.:l。kL8]d。l:ld ]Hl ]l:IV N °_LV=U0」=_1<3= =_ 3]L 。 ]lVl]l:l S丶L_°N<9N =一 v1:1a s = 41 23 A REV E 4 N 。z EC 5 , 。N 6 DESCRIPTION 7 ENGR 8 DATE B fCC ID:ZPNTPM208 IC ·9959A·TPM?OR 氬XXXXXXXXXXXXXX 「PM208 `溟 氯�@[)=[]� 臨:嘏綴巖呂 SN:- B c D E SY門BOlDESCRI卫「lO\j N O o r EVEL [\ ]「][\[ [廿\卫ACTE卫 SIGNI「][AN「[廿\\\[][\ 且\ ]付[\P [ [ ]「][「0OL「0日1N \P E C I I O \| 8 ]門PO\I \N I D I門[N\I O\j O | ME N 5 | ON「0lE R ANC E R ANG [ 二 二 S | ] [ < I � I~ | O 土0 I I土0. 2 2|0~40 I土o 2 I土0 4 ANGLE TOLERANCE RANGE V 土 I 0 土2 ° PROJEC丁ION ME丁廿OD 每三 UN丁 mm APPROVED SCALE PART NO. ORIGINAL MODEL DWG. NO. WEIGHT NAME 士5% VER 24O,|0O I土0 31土05 C廿ECKED 2 | OO QI _4-RD0007�02 2 土0 41土08 3 DES I GNED F 4 5 6 己�CUB且tCPARTS I NC. 7 S丨ZE | S H T A4 II / I 8 Product Name: TPMS TRK 2.4G Orb Sensor Model Name: TPM208 Brand: Cub

Internal Photos

Appendix EP Photographs of EUT Page 4 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 5 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 6 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 7 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 8 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 9 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Antenna Appendix EP Photographs of EUT Page 10 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Appendix EP Photographs of EUT Page 11 of 11 CN25ZFF9 001 CN25VRCF 001 CN25DDO9 001 CN25F46Y 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208

RF Exposure Info

Prü fbericht - Produkte Test Report - Products Prü fbericht-Nr.: Test report no.: CN25VRCF 001 Auftrags-Nr.: Order no.: 48282155 Seite 1 von 11 Page 1 of 11 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-09-18 Auftraggeber: Client: CUB ELECPARTS INC. No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, Taiwan Prü fgegenstand: Test item: TPMS TRK 2.4G Orb Sensor Bezeichnung / Typ-Nr.: Identification / Type no.: TPM208 Auftrags-Inhalt: Order content: FCC Certification Prü fgrundlage: Test specification: IEEE Std C95.1 47 CFR §2.1091 47 CFR §1.1310 KDB 447498 D04 Wareneingangsdatum: Date of sample receipt: 2025-09-26 Prü fmuster-Nr.: Test sample no: A004105240-010 ~ 012 A004105240-007 ~ 009 Prü fzeitraum: Testing period: 2025-10-02 - 2025-10-22 Ort der Prü fung: Place of testing: TÜ V Rheinland Taiwan Ltd. New Taipei Branch Prü flaboratorium: Testing laboratory: TÜ V Rheinland Taiwan Ltd. Taipei Testing Laboratories Prü fergebnis*: Test result*: Pass ü berprü ft von: compiled by: Ryan Chen genehmigt von: authorized by: Brenda Chen Datum: Date: 2025-10-30 Ausstellungsdatum: Issue date: 2025-10-30 Stellung / Position: Senior Project Manager Stellung / Position: Senior Project Manager Sonstiges / Other: Zustand des Prü fgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prü fbericht bezieht sich nur auf das o.g. Prü fmuster und darf ohne Genehmigung der Prü fstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prü fzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland Taiwan Ltd. 11F., No. 758, Sec. 4, Bade Rd., Taipei 105, Taiwan, R.O.C. Mail: [email protected] ∙ Web: www.tuv.com V101023GCNSR Prü fbericht - Produkte Test Report - Products Prü fbericht-Nr.: Test report no.: CN25VRCF 001 Seite 2 von 11 Page 2 of 11 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜ V Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Ü berprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜ V Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformit…

Text truncated - open the document above for the full version.

Test Report

Prü fbericht - Produkte Test Report - Products Prü fbericht-Nr.: Test report no.: CN25ZFF9 001 Auftrags-Nr.: Order no.: 48282155 Seite 1 von 26 Page 1 of 26 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-09-18 Auftraggeber: Client: CUB ELECPARTS INC. No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, Taiwan Prü fgegenstand: Test item: TPMS TRK 2.4G Orb Sensor Bezeichnung / Typ-Nr.: Identification / Type no.: TPM208 Auftrags-Inhalt: Order content: FCC Part 15C Test report (BLE) Prü fgrundlage: Test specification: FCC 47CFR Part 15: Subpart C Section 15.247 Wareneingangsdatum: Date of sample receipt: 2025-09-26 Prü fmuster-Nr.: Test sample no: A004105240-010 ~ 012 A004105240-007 ~ 009 Prü fzeitraum: Testing period: 2025-10-02 - 2025-10-22 Ort der Prü fung: Place of testing: TÜ V Rheinland Taiwan Ltd. New Taipei Branch Prü flaboratorium: Testing laboratory: TÜ V Rheinland Taiwan Ltd. Taipei Testing Laboratories Prü fergebnis*: Test result*: Pass zusammengestellt von: compiled by: Ryan Chen genehmigt von: authorized by: Brenda Chen Datum: Date: 2025-10-30 Ausstellungsdatum: Issue date: 2025-10-30 Stellung / Position: Senior Project Manager Stellung / Position: Senior Project Manager Sonstiges / Other: Zustand des Prü fgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prü fbericht bezieht sich nur auf das o.g. Prü fmuster und darf ohne Genehmigung der Prü fstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prü fzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland Taiwan Ltd. 11F., No. 758, Sec. 4, Bade Rd., Taipei 105, Taiwan, R.O.C. Mail: [email protected] ∙ Web: www.tuv.com V101023GCNSR Prü fbericht - Produkte Test Report - Products Prü fbericht-Nr.: Test report no.: CN25ZFF9 001 Seite 2 von 26 Page 2 of 26 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜ V Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Ü berprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜ V Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conform…

Text truncated - open the document above for the full version.

Test Report

CUB ELECPARTS INC. No. 6, Lane 546, Sec. 6, Changlu Road, Fuhsin Township, Changhua County, Taiwan TPMS TRK 2.4G Orb Sensor TPM208 Antenna Specification Sample Photo A. Electrical Characteristics Frequency 2402~2480 MHz S.W.R. <= 2.0 Gain 2 dBi Efficiency (%) 45% Polarization circular Impedance 50 Ohm B. Material & Mechanical Characteristics Material of Radiator NI-SWC C. Environmental Operation Temperature - 40 °C ~ + 125 °C Storage Temperature - 40 °C ~ + 125 °C Dimension Model CUB_21-006708-01 is a small loop antenna that operate from 2402 MHz to 2480 MHz 2440MHz Theta = 90 Phi = 0 Theta = 90 Phi = 90 Theta = 0 Phi = 0 Theta = 90 Phi = 180 Theta = 90 Phi = 270 Theta = 180 Phi = 0

Test Setup Photos

Appendix SP Photographs of Test Setup Page 1 of 3 CN25ZFF9 001 CN25DDO9 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Photograph 1: Test Setup for Spurious Emissions (Front View 1) Photograph 2: Test Setup for Spurious Emissions (Front View 2) Appendix SP Photographs of Test Setup Page 2 of 3 CN25ZFF9 001 CN25DDO9 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Photograph 3: Test Setup for Spurious Emissions (Back View 1) Photograph 4: Test Setup for Spurious Emissions (Back View 2) Appendix SP Photographs of Test Setup Page 3 of 3 CN25ZFF9 001 CN25DDO9 001 Product: TPMS TRK 2.4G Orb Sensor Type Identification: TPM208 Photograph 5: Test Setup for Spurious Emissions (Back View 3) Photograph 6: Test Setup for Spurious Emissions (Back View 4)

Contact Information

Applicant

June Wu(Quality System Dept. / Administrator)
[email protected]Fax: +886-4-7782009

Test Firm

TUV Rheinland Taiwan Ltd. Taipei Testing Lab.Ivan Hsieh
[email protected]Fax: +886-2-2172-1322

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Other Applications from CUB ELECPARTS INC

ZPNB122110

mmWave Radar

Jan 16, 2026

Equipment Class

VRD - Part 95 Vehicular Radar Systems
2.4 GHz Ball Sensor - FCC ID ZPNTPM201 - CUB ELECPARTS INC
ZPNTPM201

2.4 GHz Ball Sensor

Jun 03, 2021

Equipment Class

DTS - Digital Transmission System
TPMS SENSOR - FCC ID ZPNTPM202 - CUB ELECPARTS INC
ZPNTPM202

TPMS SENSOR

Sep 23, 2020

Equipment Class

DTS - Digital Transmission System
433 MHz Ball Sensor - FCC ID ZPNTPM101 - CUB ELECPARTS INC
ZPNTPM101

433 MHz Ball Sensor

Sep 14, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Blind Spot Detection System - FCC ID ZPNUNIVERSALBSD - CUB ELECPARTS INC
ZPNUNIVERSALBSD

Blind Spot Detection System

Apr 16, 2020

Equipment Class

VRD - Part 95 Vehicular Radar Systems