Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 29, 2022
Application Purpose
Original Equipment
Date of Application
Dec 29, 2022
Equipment Note
BL262TH9
Frequency Range
903.00000000 - 927.00000000
Company
EcoFlow Inc.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EcoFlow BLADE Quick Start Guide Schnellstartanleitung Guide de Démarrage Rapide Guida Rapida Guía de Inicio Rápido Beknopte Handleiding Краткое Руководство Пользователя X40 X9X9 X10 01 In the box Lieferumfang / Contenu de la boîte / Contenuto della confezione / Contenido de la caja / Inhoud van de doos / Комплект поставки ❷❹❺❸❶ 02 Preparation Vorbereitung / Préparation / Preparazione / Preparación / Voorbereiding / Подготовка A B A B A B A B 5° EN NL RU IT ES DE FR Extension cable for antenna EN NL RU IT ES DE FR For more details, please scan the QR code or visit: https://www.ecoflow.com/support/ download/blade-robotic-lawn-mower Verlängerungskabel für Antenne Câble d'extension pour antenne Prolunga dell'antenna Cable alargador para antena Verlengsnoer voor antenne Удлинительный кабель для антенны Extension cable for power adapter Verlängerungskabel für Netzteil Câble d'extension pour adaptateur électrique Prolunga dell'adattatore Cable alargador para adaptador de corriente Verlengsnoer voor voedingsadapter Удлинительный кабель для адаптера питания 1. Where to place / Platzierung des Mähers / Où placer la tondeuse / Dove posizionare il tagliaerba / Dónde colocar el cortacésped / De grasmaaier plaatsen / Где разместить косилку 2. Install the GNSS antenna / GNSS-Antenne installieren / Installation de l’antenne GNSS / Installazione dell’antenna GNSS / Instalar la antena GNSS / De antenne voor satellietnavigatie installeren / Установка антенны ГНСС 2m2m

Users Manual

❹ ❺ ≈2 hours EcoFlow App Connect EcoFlow App 03 Before Setup 04 Setup ❸ ❶ ❷ AB AB zone 2 05 Start mowing End Start 06 Return to the charging station End Welcome to Ecoflow Blade Get Started Turn on Bluetooth End EndStart EndStart EN NL RU IT ES DE FR If there is any update, please refer to the online quick start guide and user manual. Wenn es ein Update gibt, lesen Sie bitte die Online-Schnellstartanleitung und das Benutzerhandbuch. En cas de mise à jour, reportez-vous au guide de démarrage rapide en ligne et au manuel d'utilisation. In caso di aggiornamenti, consultare la Guida rapida online e il manuale dell'utente. Si hay alguna actualización, consulte la guía de inicio rápido en línea y el manual de usuario. Als er wijzigingen zijn, kunt u de online beknopte handleiding en gebruikershandleiding raadplegen. При наличии обновления обращайтесь к краткому онлайн-руководству по началу работы и руководству пользователя. 3. Install the charging station / Ladestation installieren / Installation de la station de charge / Installazione della stazione di ricarica Instalar la estación de carga / Het oplaadstation installeren / Установка зарядной станции 4. Charge the mower / Mäher aufladen / Charge de la tondeuse / Caricamento del tagliaerba / Cargar el cortacésped / De grasmaaier opladen / Зарядка газонокосилки Download the app / App herunterladen / Télécharger l’application / Download dell'app / Descargar la aplicación / Download de app / Загрузка приложения Set up working area / Arbeitsbereich einrichten / Configuration de la zone de travail / Configurazione dell'area di lavoro / Preparar el área de trabajo / Een werkgebied instellen / Настройка рабочей зоны Keep cables outside of the boundary or secure them with pegs. Halten Sie Kabel außerhalb der Arbeitsbereichs oder sichern Sie sie mit Haken. Gardez les câbles en dehors de la zone de travail ou fixez-les avec des cavaliers. Tenete i cavi fuori dall'area di lavoro o fissateli con dei picchetti. Mantenga los cables fuera del área de trabajo o fíjelos con estacas. Houd kabels buiten het werkgebied of zet ze vast met haringen. Держите кабели за пределами рабочей зоны или закрепите их колышками. Option 1 / Option 1 / Option 1 / Opzioni 1 / Opción 1 / Optie 1 / Вариант 1 Option 2 / Option 2 / Option 1 / Opzioni 2 / Opción 2 / Optie 2 / Вариант 2 Set up path / Pfad einrichten / Configuration de la trajectoire / Configurazione del percorso Crear la ruta / Een pad instellen / Настройка пути Set up no-go zones / „No-Go“-Zonen einrichten / Configuration des zones interdites Configurazione delle zone da evitare / Elegir las zonas restringidas / Verboden zones instellen / Установка запретных зон Power on / Einschalten / Mise sous tension / Accensione / Encendido / Inschakelen / Включение Login / Anmelden / Ouverture de session / Accesso / nicio de sesión / Inloggen / Вход в систему Vor der Einrichtung / Avant la configuration / Prima della configurazione Antes de la preparación y configuración / Voor de installatie / Перед настройкой Einrichtung / Configuration / Configurazione / Configuración / Instellen / НастройкаMähen starten / Commencer à tondre / Inizio della tosatura Empezar a cortar césped / Begin met maaien / Начало скашивания Zur Ladestation zurückkehren / Retour à la station de charge Ritorno alla stazione di ricarica / Volver a la estación de carga Naar het laadstation terugkeren / Возврат к зарядной станции 10% zone 1 1m

Users Manual

https://www.ecoflow.com/support/download/ blade-robotic-lawn-mower Original instructions Safety Instructions Sicherheitshinweise Instructions de Sécurité Istruzioni per la Sicurezza Instrucciones de Seguridad Veiligheidsinstructies Техника Безопасности EcoFlow BLADE EN Disclaimer Thanks for purchasing ECOFLOW BLADE (hereinafter referred to as "the mower"). This is a battery-powered automatic robotic lawn mower, which is specially designed for mowing. Any other usages not clearly approved in this user manual may damage the automatic lawn mower and could result in serious consequence or danger to the user. In order to properly use the product, please carefully read the user manual before using the product. You can reduce the risk by following the instructions and warnings in this manual, but you cannot completely eliminate the risk. Always wear long trousers and work shoes to protect yourself. After reading, please keep the document for future reference. If you do not operate this product correctly, you could cause serious injury to yourself or others, or result in product damage and property damage. Once you use this product, you are deemed to have understood, recognized and accepted all terms and contents of this document. The user undertakes to be responsible for his own actions and all consequences arising therefrom. EcoFlow is not responsible for any loss caused by the user's failure to use the product in accordance with the user manual. In compliance with laws and regulations, EcoFlow reserves the right of final interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit the EcoFlow official website for the latest product information. EN Symbols and Decals WARNING-Read instruction manual before operating the machine. WARNING-Do not ride on the machine. WARNING - Remove the disabling device before working on or lifting the machine (The disabling device means battery pack) *Make sure the battery is removed before working on or lifting the machine. WARNING-It is not permitted to dispose of this product as normal household waste. Ensure that the product is recycled in accordance with local legal requirements. This product conforms to the applicable EC Directives. Class II appliance Class III appliance SMPS incorporating a short-circuit-proof safety isolating transformer (inherently or non- inherently) CLASS 1 LASER PRODUCT. Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC60825-1 Ed.3., as described in Laser Notice No.56, dated May 8, 2019. WARNING-Keep a safe distance from the machine when operating. Keep hands and feet away from the rotating blades. SMPS (Switch mode power supply unit ) Efficiency Level Direct current Alternating current CLASS 1 LASER PRODUCT ~ EN Safety Warnings Before mowing When mowing 1. Please read and follow the instructions & warnings carefully in user manual before operating the mower. 2. The operator is responsible for accidents or hazards occurring to other people on their property. 3. Please regularly inspect the area where the mower is used and remove all the obstacles. 4. DO NOT use the mower if any part of it is damaged, worn or inoperable. 5. DO NOT modify the mower by yourself, please contact after-sales service of EcoFlow if necessary. 6. Please be careful of all the potential hazards that are hidden in the grass. 7. Use the mower in daylight or good artificial light. 8. DO NOT operate the mower in bad weather, such as thunderstorm or snow. 9. Use a residual-current device (RCD) with a tripping current of maximum 30 mA when you connect the power supply to the power outlet. 10. To achieve better mowing results and prolong its service life, please be sure to keep the mower clean and the blades in good condition. Inspection and maintenance should be carried out by an adult every week. Any damaged or worn parts should be replaced. DO NOT perform maintenance when wearing open sandals or barefoot. Always wear long trousers and work shoes when maintaining the mower. 11. We recommend that you replace the blades every quarter depending on their condition. Replace all the three blades and screws at the same time for further use. Only use the right type of screws and original blades as approved by EcoFlow. When replacing the blade, make sure that the mower is completely stopped running and remove the battery temporarily. We recommend that you wear heavy work gloves in case of sharp blades. 1. DO NOT lift up the mower while it is in use. 2. DO NOT allow children to get close to or play with the mower when it is in use. 3. DO NOT touch the rotating blades! Do not put hands or feet under or near the rotating parts. 4. If accident or breakdown happens when the mower is running, please press STOP button immediately. 5. During the manual control, do not overextend it and maintain balance at all times. Secure footing when it is walking on slopes. Always wear long trousers and work shoes. 6. Do not run while operating the mower or its peripherals. 7. If there are abnormal vibrations, please turn off the mower, place it on level ground for about 30 seconds and then restart. If the issue persists, please contact authorized after-sales service. 8. Please make sure the mower has completely stopped and the battery has been removed before you clean, repair or inspect it. 9. If the machine is not used for a long time, remove the battery. Store the machine indoors in a cool and dry place. 1. Never allow children, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge or people unfamiliar with these instructions to use the machine. Local regulations may restrict the age of the operator. 2. WARNING: For the purposes of recharging the battery,only use the detachable supply unit KT180A3600500XX provided with this appliance. 3. For the European Union: use only with the KT180A3600500EU supply unit. For the United Kingdom: use on…

Text truncated - open the document above for the full version.

Cover Letter(s)

EcoFlowInc. AgentAuthorizationLetter (2022-12-30) RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,authorizeMicomLabsInc.,575BoulderCourt,Pleasanton,California94566, USAtoactonourbehalfinallmattersrelatingtoapplicationforequipment authorization,includingthesigningofalldocumentsrelatingtothesematters. Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, Signature: Name:VickyGuan CompanyName:EcoFlowInc. Address:PlantA202,FounderTechnologyIndustrialPark,ShiyanSub-district,Bao ’ anDistrictShenzhen,Guangdong518000China

Cover Letter(s)

EcoFlowInc. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2022-12-29 Subject;RequestforConfidentiality FCCID:2A2P9-BL262TH9 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription SWSECURITYDESCRIPTION PartsList Tuneup Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, EcoFlowInc. Signature: Name:VickyGuan Title:R&DEngineer

ID Label/Location Info

LabelLocation: Label:

Internal Photos

GPSRXANT LoraANT

RF Exposure Info

RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiation asspecifiedin§1.1307(b) FCCID:2A2P9-BL262TH9 EUTSpecification EUTWifiDigitalPhotoFrame Frequencyband(Operating)WLAN:2.412GHz~2.462GHz WLAN:5.18GHz~5.24GHz WLAN:5.745GHz~5.825GHz Others:Bluetooth: 902~928MHz DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ ExposureclassificationOccupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure(S=1mW/cm2) AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Antennagain(Max) 0.7dbi EvaluationappliedMPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaand totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistance wheretheMPElimitisreached. MaxMeasurementResult Operating Mode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power densityat 20cm Power densityLimits (mW/cm2) (dBm)(dBm)(dBm)(dBi)(mW/cm2) Lora21.91121.911±122.9110.70.1955 1 Result:NoStandaloneSARtestisrequired.

Test Report

1 SPECIFICATIONSFORAPPROVAL AntennaName:LoraBaseAntenna ProductName:MH100 IssuedDate:2022-11-15 2 Index SPECIFICATIONSFORAPPROVAL ...........................................................................................1 1.ProductSpecification .......................................................................................................................3 3.TestReport ....................................................................................................................................3 4.ProductDrawing.............................................................................................................................6 3 1.ProductSpecification 2.TestEquipment&Conditions 1.NetworkAnalyzersAgilent8753D/5071C 2.HSPAandLTEprotocoltestsetR&SCMW500-PT 3.CommunicationsTestSetAgilent8960 4.3DChamberTestSystem 3.TestReport 3.1VoltageStandingWaveRatio(VSWR). ElectricalCharacteristics Frequency860MHz~930MHz VSWR<2.0 Efficiency>48% Impedance50Ohm PolarizationLinear Gain ≤ 1.1dB 4 3.2Efficientandgain. PassiveTestForWIFI/BT Freq(MHz) 860870880890900910920930 Effi(%) 63.7764.8663.9560.7257.2753.9951.4748.39 Gain(dBi) 0.981.081.10.940.70.490.24-0.11 5 6 4.ProductDrawing

Test Report

ReportNo.:18220WC20127301FCCID:2A2P9-BL262TH9Page1of49 Code:AB-RF-05-b FCCTestReport ClientName:EcoFlowInc. ClientAddress: PlantA202,FounderTechnologyIndustrial Park,ShiyanSub-district,Bao’anDistrict Shenzhen,Guangdong518000China ProductName:BL262TH9 ReportDate:Dec.29,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20127301FCCID:2A2P9-BL262TH9Page2of49 Code:AB-RF-05-b Contents 1.GeneralInformation..............................................................................................................................................5 1.1.ClientInformation.......................................................................................................................................5 1.2.DescriptionofDevice(EUT)....................................................................................................................5 1.3.AuxiliaryEquipmentUsedDuringTest...................................................................................................6 1.4.DescriptionofTestConfiguration............................................................................................................6 1.5.DescriptionOfTestSetup.........................................................................................................................7 1.6.TestEquipmentList...................................................................................................................................8 1.7.MeasurementUncertainty........................................................................................................................9 1.8.DescriptionofTestFacility........................................................................................................................9 2.SummaryofTestResults...................................................................................................................................10 3.ConductedEmissionTest..................................................................................................................................11 3.1.TestStandardandLimit..........................................................................................................................11 3.2.TestSetup.................................................................................................................................................11 3.3.TestProcedure.........................................................................................................................................11 3.4.TestData...................................................................................................................................................11 4.RadiationSpuriousEmissionandBandEdge...............................................................................................14 4.1.TestStandardandLimit..........................................................................................................................14 4.2.TestSetup.................................................................................................................................................14 4.3.TestProcedure.........................................................................................................................................15 4.4.TestData...................................................................................................................................................16 5.MaximumPeakOutputPowerTest..................................................................................................................22 5.1.TestStandardandLimit..........................................................................................................................22 5.2.TestSetup.................................................................................................................................................22 5.3.TestProcedure.........................................................................................................................................22 5.4.TestData...................................................................................................................................................22 6.6DBOccupyBandwidthTest.............................................................................................................................24 6.1.TestStandardandLimit..........................................................................................................................24 6.2.TestSetup.................................................................................................................................................24 6.3.TestProcedure.........................................................................................................................................24 6.4.TestData...................................................................................................................................................24 7.PowerSpectralDensityTest.............................................................................................................................26 7.1.TestStandardandLimit..........................................................................................................................26 7.2.TestSetup.................................................................................................................................................26 7.3.TestProcedure.........................................................................................................................................26 7.4.TestData...................................................................................................................................................26 8.100kHzBandwidthofFrequencyBandEdgeRequirement........................................................................28 8.1.TestStandardandLimit..............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

PhotoofConductedEmissionMeasurement PhotoofRadiationEmissionTest

Contact Information

Applicant

Vicky Guan
[email protected]075586660185Fax: N.A.

Technical Contact

EcoFlow Inc.
[email protected]

China

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 927 MHz150.70 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from EcoFlow Inc.

2A2P9-PD763764-PD

WiFi/Bluetooth wireless Module

Aug 24, 2026

Equipment Class

DTS - Digital Transmission System
2A2P9-EFTT5PG1

Power Station

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
2A2P9-EFTT5CG1

Power Station

Jul 20, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2A2P9-EFSD006

WiFi/Bluetooth wireless Module

Jun 18, 2026

Equipment Class

DTS - Digital Transmission System
2A2P9-REEFWM36

EcoFlow 4G Dongle SEP

Apr 22, 2026

Equipment Class

PCB - PCS Licensed Transmitter