Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EcoFlow AppSupport User Manual V0.1 EcoFlow Smart Generator 3000 (Dual Fuel) Low Generator Set Scan the QR code for User Manual or visit: https://www.ecoflow.com/support/download/ SAVE THESE INSTRUCTIONS, WARNING: IMPORTANT SAFETY INSTRUCTIONS Disclaimer 1 Terms and Abbreviations 1 Safety Guidelines 1 Safety Warning 1 General Safety Guidelines 1 Restrictions on Use 2 Special Requirements 2 Operation 2 Maintenance, Storage, and Transportation 3 Important Safety Labels 4 Generator Ground Circuit 5 Status of the Neutral Conductor 5 Powercord: Using Extension Cords 5 Exhaust and Evaporative Emissions Control Warranty Statement 6 FCC Statement 8 IC Statement 9 Package List 10 Getting Started 11 Appearance 11 Display Screen 13 Preparation Before Use 14 Operation 17 Maintenance and Servicing 20 Checking the Spark Plug 21 Adjusting the Carburetor 21 Replacing the Engine Oil 21 Cleaning the Air Filter 22 Cleaning the Fuel Filter Strainer 22 Cleaning the Muffler 23 Replacing the Rechargeable Battery 23 Storage and Transportation 24 Draining the Fuel 24 Storing the Generator 24 Rechargeable Battery 24 Use after storage 24 Transportation 25 Troubleshooting Guide 26 Specifications 27 Circuit Diagram 28 CONTENTS ENGLISH 1 | Disclaimer Please read the product document and ensure that you understand it fully before using the product. After reading this document, keep it for future reference. Improper use of this product may cause serious injury to yourself or others, or cause product damage and property loss. Once you use this product, it is deemed that you understand, approve and accept all the terms and content in this document. EcoFlow is not liable for any loss caused by the user's failure to use the product in compliance with the product document. In compliance with laws and regulations, EcoFlow reserves the right to the final interpretation of this document and all documents related to the product. This document is subject to changes (updates, revisions, or termination) without prior notice. Please visit EcoFlow's official website to obtain the latest product information: https://www.ecoflow.com/. The images in this manual are for demonstration only. Please refer to the actual product for accurate details. Please note that this document is a beta version. The final design, components, and specifications of our products may differ from what is shown or described here. EcoFlow reserve the right to make changes at any time without prior notice. Terms and Abbreviations The following abbreviations or terms are used in this document: TermDefinition The generatorRefers to "EcoFlow Smart Generator 3000 (Dual Fuel)" LPGStands for "Liquefied Petroleum Gas" GASStands for "Gasoline" IoTStands for Wi-Fi and Bluetooth connections ACStands for "Alternating Current" DCStands for "Direct Current" RPMStands for "Revolutions Per Minute" Safety Guidelines SAVE THESE INSTRUCTIONS, WARNING: IMPORTANT SAFETY INSTRUCTIONS Safety Warning The safety of you and others, as well as of property are of the primary importance. Please carefully read the extremely important safety warnings we have written in the User Manual and the sticker of the generator set. This is to remind you of the potential dangers which may harm you and others. Before each safety warning is a symbol and one of the three following words: danger, warning or caution. These words indicate: If you fail to follow the instructions, your life will be at risk or you will be severely injured. If you fail to follow the instructions, your life may be at risk or you may be seriously injured. If you fail to follow the instructions, your generator set and other property may be damaged. General Safety Guidelines • Carbon Monoxide Hazards 1. Exhaust gas from the generator contains toxic carbon monoxide fumes. Inhaling these fumes may lead to shock, loss of consciousness or even death 2. Do not use the generator indoors, including in homes, garages, basements, and other enclosed or partially- enclosed areas. 3. Keep the generator away from doors, windows, and vents to prevent CO from entering indoors. 4. Leave at least three feet of space on all sides of the generator to ensure adequate ventilation. | 2 5. Install battery-powered carbon monoxide alarms in your home to alert for CO level. • Electrical Hazards 6. Do not use the generator in damp environments. 7. Do not operate the generator with a damaged cord or plug. 8. Do not overload the generator. Ensure the connected loads do not exceed its wattage capacity to prevent damage. 9. Earthing the Generator: The generator is equipped with a grounding system that connects its frame components to the ground terminal in the AC outlet. Before use, always ensure the grounding terminal is connected to appropriate grounding equipment, such as a grounding rod. Grounding codes can vary by location. Check with your local electrical regulation for specific requirements. 10. Floating Neutral: The grounding system does not connect to the AC neutral line. 11. Electrical Backfeeding Hazards: Do not connect the generator to a building’s electrical system unless a licensed electrician has installed an isolation switch. Check with your local electrical regulation for specific requirements. • Fire Hazards 12. Keep any combustibles at least 1m / 3ft away. The generator’s components or exhaust system can become very hot during operation. 13. Keep fuel away from sparks, open flames, and any other ignition sources. • Environment Requirements 14. Follow the environment temperature requirements specified in the product specification to use or store the generator. Avoid degradation or damage to the generator, or risks to personal safety due to excessively high or low temperatures. 15. Usage in High Altitude Areas: In high altitude areas, the atmospheric pressure may reduce the amount of air intake, decline the performance and increase the fuel consumption of standard carburetors. Moreover, the dense mixture may contaminate the spark plug and lead to…
Text truncated - open the document above for the full version.
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref:Attestation Statements Part 2.911(d) (5) (i) Filing SUBJECT: FCC Application for FCC ID: 2A2P9-PGGE307 To Whom It May Concern: EcoFlow Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signatory [Vicky Guan, Engineer]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref:Attestation Statements Part 2.911(d) (5) (ii) Filing SUBJECT: FCC Application for FCC ID: 2A2P9-PGGE307 To Whom It May Concern: EcoFlow Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Signatory [Vicky Guan, Engineer]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d) (7) Filing Grantee Code: 2A2P9 Applicant FRN: 0031193519 EcoFlow Inc.certifies that, as of the date of the filing of the application, EcoFlow Technology Inc is our designated U.S. agent for service of process for the above referenced Grantee Code.EcoFlow Inc.accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. EcoFlow Technology Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced Grantee Code. Designated U.S. Agent Information: Company Name: EcoFlow Technology Inc U.S. Agent FRN: 0033593781 Address: 200 CONTINENTAL DRIVE SUITE 401, OFFICE 434, NEW AR DE19713, NEWARK, DE 19713, United States Contact Person: devin.li Phone: (626) 998-0366 Email: [email protected] Sincerely, Company: EcoFlow Inc.Designated Agent: EcoFlow Technology Inc Company Representative: Vicky GuanDesignated Agent Representative: devin.li Signature:Signature:
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 FEDERAL COMMUNICATIONS COMMISSION AUTHORIZATION AND EVALUATION DIVISION 7435 OAKLAND MILLS ROAD COLUMBIA, MD 21046 SUBJECT: FCCApplication for FCC ID: 2A2P9-PGGE307 Confidentiality Request To whom it may concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. ☒ Block Diagram ☐ Tune-Up Information ☒ Operational Description ☐ Security Information ☒ Schematics ☐ Software Defined Radio (SDR) Information ☐ Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ User Manual ☐For 45 days, pursuant to Public Notice DA04-1705. or ☐For 180 days pursuant to KDB 726920 D01. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signatory [Vicky Guan, Engineer]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: FCC Application for FCC ID: 2A2P9-PGGE307 To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and foundto comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B device. I understand the following FCCrequirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain thename, address, and phone number of the responsible party, which must be located within the United States.According to 2.909(b), the responsible party is either the Manufactureror if the product is imported the Importer . Sincerely, Signatory [Vicky Guan, Engineer]
EcoFlowInc. RM401,Plant#1,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict,Shenzhen,China Date: 2024-09-05 FEDERAL COMMUNICATIONS COMMISSION AUTHORIZATION AND EVALUATION DIVISION 7435 OAKLAND MILLS ROAD COLUMBIA, MD 21046 SUBJECT: FCCApplication for FCC ID: 2A2P9-PGGE307 POWER OF ATTORNEY To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, EcoFlow Inc. are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Signatory [Vicky Guan, Engineer]
ReferenceNo.:WTX24X07173520WPage2of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EXHIBIT2-EUTEXTERNALPHOTOGRAPHS EUTView1 EUTView2 ReferenceNo.:WTX24X07173520WPage3of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EUTView3 EUTView4 ReferenceNo.:WTX24X07173520WPage4of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EUTView5 EUTView6 ReferenceNo.:WTX24X07173520WPage5of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EUTView7
Reference No.: WTX24X07173520WPage 1 of 15 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn ANNEX EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format Specifications: The label shall be securely affixed to a permanently attached part of the device, in a location where it is visible or easily accessible to the user, and shall not be readily detachable. The label shall be sufficiently durable to remain fully legible and intact on the device in all normal conditions of use throughout the device’s expected lifetime. Proposed Label Location on EUT FCCIDLabel Location
ReferenceNo.:WTX24X07173520WPage6of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EXHIBIT3-EUTINTERNALPHOTOGRAPHS EUTHousingand BoardView1 EUTHousingand BoardView2 ReferenceNo.:WTX24X07173520WPage7of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn EUTHousingand BoardView3 Solder Board-Component View1 ReferenceNo.:WTX24X07173520WPage8of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn Solder Board-Component View2 Solder Board-Component View3 ReferenceNo.:WTX24X07173520WPage9of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn Solder Board-Component View4 Solder Board-Component View5 ReferenceNo.:WTX24X07173520WPage10of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn Solder Board-Component View6 Solder Board-Component View7 ReferenceNo.:WTX24X07173520WPage11of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn Solder Board-Component View8 Solder Board-Component View9 ReferenceNo.:WTX24X07173520WPage12of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn Solder Board-Component View10 AntennaView1 ExternalPCBantenna ReferenceNo.:WTX24X07173520WPage13of15 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cn AntennaView2 OnboardPCBantenna
1.RFExposureRequirements 1.1GeneralInformation ClientInformation Applicant:EcoFlowInc. Addressofapplicant: RM401,Plant#l,RunhengIndustrialZone,FuhaiStreet,Bao'an District,Shenzhen,518000China Manufacturer:EcoFlowInc. Addressofmanufacturer: RM401,Plant#l,RunhengIndustrialZone,FuhaiStreet,Bao'an District,Shenzhen,518000China GeneralDescriptionofEUT: ProductName:EcoFlowSmartGenerator3000(DualFuel) TradeNameECOFLOW;EFECOFLOW ModelNo.:EF-SG-H03-1 AddingModel(s):/ RatedVoltage:BatteryDC12.8V;OutputAC120V BatteryCapacity:1500mAh PowerAdapter:/ FCCID:2A2P9-PGGE307 EquipmentType:Mobiledevice TechnicalCharacteristicsofEUT: Bluetooth BluetoothVersion:V5.1(BLEmode) FrequencyRange:2402-2480MHz RFOutputPower: OnboardPCBantenna:1Mbps:5.77dBm(Conducted) 2Mbps:5.68dBm(Conducted) ExternalPCBantenna:1Mbps:7.49dBm(Conducted) 2Mbps:7.86dBm(Conducted) DataRate:1Mbps,2Mbps Modulation:GFSK QuantityofChannels:40 ChannelSeparation:2MHz TypeofAntenna:PCBAntenna AntennaGain: OnboardPCBantenna:2.89dBi ExternalPCBantenna:4.06dBi Wi-Fi SupportStandards:802.11b,802.11g,802.11n,802.11ax FrequencyRange: 2412-2462MHzfor802.11b/g/n/ax(HT/HE20) 2422-2452MHzfor802.11n(HT40) RFOutputPower:OnboardPCBantenna:18.38dBm(Conducted) ExternalPCBantenna:17.18dBm(Conducted) TypeofModulation:CCK,OFDM,QPSK,BPSK,16QAM,64QAM,256QAM,1024QAM QuantityofChannels:11for802.11b/g/n/ax(HT/HE20);7for802.11n(HT40) ChannelSeparation:5MHz TypeofAntenna:PCBAntenna AntennaGain: OnboardPCBantenna:2.89dBi ExternalPCBantenna:4.06dBi 1.2RFExposureExemption Accordingto§1.1307(b)(3)andKDB447498D04InterimGeneralRFExposureGuidancev01,system operatingundertheprovisionsofthissectionshallbeoperatinginamannerthatthepublicisnotexposedto radiofrequencyenergylevelinexcesslimitformaximumpermissibleexposure. OptionA:FCCRulePart1.1307(b)(3)(i)(A):Theavailablemaximumtime-averagedpowerisnomorethan 1mW,regardlessofseparationdistance. OptionB:FCCRulePart1.1307(b)(3)(i)(B):Theavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,islessthanorequaltothethresholdP th (mW)describedinthe followingformula.P th isgivenby: OptionC:FCCRulePart1.1307(b)(3)(i)(C):Theminimumseparationdistance(Rinmeters)fromthebodyof anearbypersonforthefrequency(finMHz)atwhichthesourceoperates,theERP(watts)isnomorethanthe calculatedvalueprescribedforthatfrequency.Rmustbeatleastλ/2π,whereλisthefree-spaceoperating wavelengthinmeters. SingleRFSourcesSubjecttoRoutineEnvironmentalEvaluation RFSourcefrequency(MHz)ThresholdERP(watts) 0.3-1.341,920R 2 1.34-303,450R 2 /f 2 30-3003.83R 2 300-1,5000.0128R 2 f 1,500-100,00019.2R 2 ForMultipleRFsources:FCCRulePart1.1307(b)(3)(ii): (A)Theavailablemaximumtime-averagedpowerofeachsourceisnomorethan1mWandthereisa separationdistanceoftwocentimetersbetweenanyportionofaradiatingstructureoperatingandthe nearestportionofanyotherradiatingstructureinthesamedevice,exceptifthesumofmultiplesourcesis lessthan1mWduringthetime-averagingperiod,inwhichcasetheymaybetreatedasasinglesource (separationisnotrequired). (B)InthecaseoffixedRFsourcesoperatinginthesametime-averagingperiod,orofmultiplemobileor portableRFsourceswithinadeviceoperatinginthesametimeaveragingperiod,ifthesumofthe fractionalcontributionstotheapplicablethresholdsislessthanorequalto1asindicatedinthefollowing equation. 1.3CalculatedResult Radio Access Technology Prediction Frequency Output Power Antenna Gain Duty Cycle Tune-Up Time-AveragedPower ERP (MHz)(dBm)(dBi)(%)(dBm)(dBm) Onboard PCB antenna 24025.772.89100 6.006.74 External PCB antenna 24027.864.061008.009.91 Onboard PCB antenna 241218.382.8910019.0019.74 External PCB antenna 241217.184.0610018.0019.91 Frequency Option Min.DistanceMax.PowerExposureLimit Ratio Result (MHz)(cm)(dBm)(mW)(mW)Pass/Fail 2402C20.006.744.72768.000.01Pass 2402C20.009.919.79768.000.01Pass 2412C20.0019.7494.19768.000.12Pass 2412C20.0019.9197.95768.000.13Pass Note:1.Time-AveragedPower=OutputPower*DutyCycle;ERP=Time-AveragedPower+Antenna gain-2.15dB 2.OptionA,BandCrefersasclause1.2. 3.ForoptionB,Max(time-averagedpower,effectiveradiatedpower(ERP))convertstoMax.Power.For optionC,ERPconvertstoMax.Power; 4.ForoptionB,P th (mW)convertstoExposureLimit(mW);ForoptionC,ERP(W)convertstoExposure Limit(mW). 5.Ratio=Tune-UpERP(mW)/ExposureLimit(mW) ModeforSimultaneousMulti-bandTransmission: RadioAccess Technology Ratio1Ratio2 Simultaneous Ratio Limit Result Pass/Fail ------------ Note:Theradioequipmentcan'ttransmitonmultipleantennassimultaneouslyinthesameband. Result:Pass
Antennatestreport Test Laboratory ShenzhenMorlabCommunicationsTechnologyCo.,Ltd. Address FL.1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Contact:EDWARD.LYU+8675536698555 ModelPCBAntenna ManufacturerDongguanYoubiElectronicsCo.,LTD Address Building79,NewSunIndustrialCity,LincunCommunity,TangxiaTown,Dongguan City,GuangdongProvince 1.Testprocedures StandardsDescriptionofTestItemResult ANSI/IEEE149-2021 IEEERecommendedPracticeforAntenna Measurements Compliant 2.TestItemsandEquipment Testitems Testequipment SParameter 1.ReturnLoss2.VSWR Networkanalyzer (AgilentE5071B) ThewholemachineofPassive parameters 1.Frequency2.Gain 3.RadiationPattern 1.3Dmicrowave darkroom(6m*6m*6m) 2.Networkanalyzer (AgilentE5071B) 3.TestEquipment EquipementNameSerialNo. Type Manufacture Cal.Date Cal.DueDate NetworkAnalyzerMY46110140E5071CAgilent2024.05.302025.05.29 OTAChamberTJ2235-Q1793 AMS-8923- 150 ETS2022-11-302025-11-29 AntennaMeasurement System 1685 EMQuest EMQ-100 V1.13Build 21267 ETSN/AN/A 4.Nameofcommercialtestsoftware SoftwareNameSerialNo. Version Manufacturer AntennaMeasurementSystem1685 "EMQuestEMQ-100 V1.13Build21267" ETS 5.Theuncertaintyiscalculatedusingthemethodssuggestedinthe“GuidetotheExpression ofUncertaintyinMeasurement"(GUM)publishedbyISO.Whenthetestresultisa criticalvalue,wewillusethemeasurementuncertaintygivethejudgmentresultbasedon the95%Confidenceintervals. 6.DUTSetupPhoto 7.PCBAntennaPhysicalSize(unit:mm) 8.AntennaElectricalSpecification On-boardAntenna Freq2.4~2.483GHz Gain4.06dBi VSWR<2 Impedance50ohm PolarizationLinear TypeofAntennaPCBAntenna OutlineDimensions45mm*12mm*1mm ManufactureEcoFlow Efficiency≥53.19% ConnectorTypeMicrostriplines OperatingTemperature-40°C~+85°C StorageTemp-40°C~+85°C 9.2.4GAntennaType&Gain Type:PCBAntenna On-boardAntenna Frequency( MHz) Gain(dBi)efficiency 240058.004.03 241057.014.06 242054.823.95 243053.453.74 244053.193.57 245054.213.52 246054.903.55 247054.163.45 248054.633.60 249053.723.50 250058.004.03 10.PatternandGain PCBAntenna PHI=0DEG Gain G a i n ( d B i ) Angle (°) Scale: 5/div Min: -20 Max: 5 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz PHI=90DEG Gain G a i n ( d B i ) Angle (°) Scale: 2/div Min: -18 Max: 2 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz THETA=90DEG Gain G a i n ( d B i ) Angle (°) Scale: 5/div Min: -20 Max: 5 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz Testerby:EDWARD.LYU
Antennatestreport Test Laboratory ShenzhenMorlabCommunicationsTechnologyCo.,Ltd. Address FL.1-3,BuildingA,FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Contact:EDWARD.LYU+8675536698555 ModelOn-boardAntenna ManufacturerDongguanYoubiElectronicsCo.,LTD Address Building79,NewSunIndustrialCity,LincunCommunity,TangxiaTown,Dongguan City,GuangdongProvince 1.Testprocedures StandardsDescriptionofTestItemResult ANSI/IEEE149-2021 IEEERecommendedPracticeforAntenna Measurements Compliant 2.TestItemsandEquipment Testitems Testequipment SParameter 1.ReturnLoss2.VSWR Networkanalyzer (AgilentE5071B) ThewholemachineofPassive parameters 1.Frequency2.Gain 3.RadiationPattern 1.3Dmicrowave darkroom(6m*6m*6m) 2.Networkanalyzer (AgilentE5071B) 3.TestEquipment EquipementNameSerialNo. Type Manufacture Cal.Date Cal.DueDate NetworkAnalyzerMY46110140E5071CAgilent2024.05.302025.05.29 OTAChamberTJ2235-Q1793 AMS-8923- 150 ETS2022-11-302025-11-29 AntennaMeasurement System 1685 EMQuest EMQ-100 V1.13Build 21267 ETSN/AN/A 4.Nameofcommercialtestsoftware SoftwareNameSerialNo. Version Manufacturer AntennaMeasurementSystem1685 "EMQuestEMQ-100 V1.13Build21267" ETS 5.Theuncertaintyiscalculatedusingthemethodssuggestedinthe“GuidetotheExpression ofUncertaintyinMeasurement"(GUM)publishedbyISO.Whenthetestresultisa criticalvalue,wewillusethemeasurementuncertaintygivethejudgmentresultbasedon the95%Confidenceintervals. 6.DUTSetupPhoto 7.PCBAntennaPhysicalSize(unit:mm) 8.AntennaElectricalSpecification On-boardAntenna Freq2.4~2.483GHz Gain2.89dBi VSWR<2 Impedance50ohm PolarizationLinear TypeofAntennaPCBAntenna OutlineDimensions27mm*8.5mm*1.5mm ManufactureEcoFlow Efficiency≥52.18% ConnectorTypeMicrostriplines OperatingTemperature-40°C~+85°C StorageTemp-40°C~+85°C 9.2.4GAntennaType&Gain Type:PCBAntenna On-boardAntenna FrequencyGain(dBi)efficiency 240055.612.43 241054.862.24 242052.991.99 243052.031.91 244052.182.00 245053.262.20 246054.452.29 247054.192.25 248054.722.46 249054.032.89 10.PatternandGain On-boardAntenna PHI=0DEG Gain G a i n ( d B i ) Angle (°) Scale: 2/div Min: -12 Max: 2 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz PHI=90DEG Gain G a i n ( d B i ) Angle (°) Scale: 5/div Min: -20 Max: 5 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz THETA=90DEG Gain G a i n ( d B i ) Angle (°) Scale: 5/div Min: -20 Max: 5 0 180 30 210 60 240 90270 120 300 150 330 2300 MHz 2310 MHz 2320 MHz 2330 MHz 2340 MHz 2350 MHz 2360 MHz 2370 MHz 2380 MHz 2390 MHz 2400 MHz 2410 MHz 2420 MHz 2430 MHz 2440 MHz 2450 MHz 2460 MHz 2470 MHz 2480 MHz 2490 MHz 2500 MHz 2510 MHz 2520 MHz 2530 MHz 2540 MHz 2550 MHz 2560 MHz 2570 MHz 2580 MHz 2590 MHz 2600 MHz Testerby:EDWARD.LYU
WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 1 of 33 TESTREPORT ReferenceNo.......................:WTX24X07173520W002 FCCID....................................:2A2P9-PGGE307 Applicant...............................:EcoFlowInc. Address.................................: RM401,Plant#l,RunhengIndustrialZone,FuhaiStreet,Bao'anDistrict, Shenzhen,518000China Manufacturer........................:ThesameasApplicant Address.................................:ThesameasApplicant ProductName......................:EcoFlowSmartGenerator3000(DualFuel) ModelNo...............................:EF-SG-H03-1 Standards..............................:FCCPart15.247 DateofReceiptsample.....:2024-07-24 DateofTest...........................:2024-07-24to2024-08-27 DateofIssue........................:2024-08-28 TestReportFormNo.......... : WTX_Part15_247W TestResult............................:Pass Remarks: Theresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbe reproduced,exceptinfull,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithout specificstampoftestinstituteandthesignaturesofapprover. PreparedBy: WaltekTestingGroup(Shenzhen)Co.,Ltd. Address:1/F.,Room101,Building1,HongweiIndustrialPark,Liuxian2ndRoad, Block70Bao'anDistrict,Shenzhen,Guangdong,China Tel.:+86-755-33663308Fax.:+86-755-33663309Email:[email protected] Testedby:Approvedby: MikeShiJasonSu ReferenceNo.:WTX24X07173520W002 WaltekTestingGroup(Shenzhen)Co.,Ltd. Http://www.waltek.com.cnPage 2 of 33 TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................4 1.1PRODUCTDESCRIPTIONFOREQUIPMENTUNDERTEST(EUT)........................................................................4 1.2TESTSTANDARDS.................................................................................................................................................5 1.3TESTMETHODOLOGY...........................................................................................................................................5 1.4TESTFACILITY.......................................................................................................................................................5 1.5EUTSETUPANDTESTMODE..............................................................................................................................6 1.6MEASUREMENTUNCERTAINTY.............................................................................................................................7 1.7TESTEQUIPMENTLISTANDDETAILS..................................................................................................................8 2.SUMMARYOFTESTRESULTS.........................................................................................................................11 3.ANTENNAREQUIREMENT.................................................................................................................................12 3.1STANDARDAPPLICABLE......................................................................................................................................12 3.2EVALUATIONINFORMATION................................................................................................................................12 4.POWERSPECTRALDENSITY...........................................................................................................................13 4.1STANDARDAPPLICABLE.................................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 68.90 mW |
WiFi/Bluetooth wireless Module
Equipment Class
DTS - Digital Transmission SystemPower Station
Equipment Class
DTS - Digital Transmission SystemPower Station
Equipment Class
NII - Unlicensed National Information Infrastructure TXWiFi/Bluetooth wireless Module
Equipment Class
DTS - Digital Transmission SystemEcoFlow 4G Dongle SEP
Equipment Class
PCB - PCS Licensed Transmitter