Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 20, 2026
Application Purpose
Original Equipment
Equipment Note
GPS Tracker
Frequency Range
2402.00000000 - 2480.00000000
Company
Trackimo INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EN Quick Start Guide The smart GPS tracker Get in touch Quick start guide EN Thank you for choosing Tracki. Our support team is available 7 days a week to help with your queries. We are dedicated to addressing your issues as fast as possible and will always go the extra mile to ensure your satisfaction. Contact us any day at: e-Mail: [email protected] US: +1 (323) 785 2020 (9AM-11PM EST) UK: +44 7700 175 888 (3PM-11PM CET) Power / SOS button Light indicators 2 Charge for 2hrs before first use Take the device outdoors and start tracking * Short-press the button to ensure the device is on. If none of the lights turn on, press the button for 5s 3 Getting started Quick start guide 1 Scan to download, sign in to the TrackiPet app and view the full user manual Buttons and lights Quick start guide Device is starting up (long press 5s) Device is charging (connected to power) Device is fully charged Activate SOS mode (triple press) Device is on but offline (single press) Device is online (single press) Battery is low (flashes continuosly) Device is powering off (long press 3s) 8 Quick start gu ide Changing accessories 1 2 3 4 5 6 7 8 FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This GPS Tracker meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. Thestandards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: GPS Tracker (FCC ID: 2AAI6-TRKI005-C) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certification for when properly worn on the body is 1.481W/kg. This device was tested for typical body-worn operations with the back of the handset kept 5mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 5mm separation distance between the user's body and the back of the handset. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 5mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

Internal Photos

Page 1 of 6 ReportNo.:STS2511172 APPENDIX-PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS Photo1 Photo2 Page 2 of 6 ReportNo.:STS2511172 Photo3 Photo4 BTAntenna LTEAntenna WIFIRXAntenna GPSAntenna Page 3 of 6 ReportNo.:STS2511172 Photo5 Photo6 Page 4 of 6 ReportNo.:STS2511172 Photo7 Photo8 Page 5 of 6 ReportNo.:STS2511172 Photo9 Photo10 Page 6 of 6 ReportNo.:STS2511172 Photo11

Test Setup Photos

Page 1 of 2 FCC ID: 2AAI6-TRKI005-C Setup photo AC Conduction RF Conduction Page 2 of 2 FCC ID: 2AAI6-TRKI005-C RE (Below 1GHz) RE (Above 1GHz)

Test Setup Photos

SARSetupphotosforFCCID:STS2511172H02 Frontside(separationdistanceis5mm) BackSide(separationdistanceis5mm)

Test Report

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2511172W05 Issued for Trackimo INC. 680 Central Ave Cedarhurst, New York 11516 United States Product Name: GPS Tracker Brand Name: Trackimo, Tracki Model Name: TRKI005-C Series Model(s): N/A FCC ID: 2AAI6-TRKI005-C Test Standards: FCC Part15.247 Page 2 of 54 Report No.: STS2511172W05 TEST REPORT Applicant’s Name ..................: Trackimo INC. Address ..................................: 680 Central Ave Cedarhurst, New York 11516 United States Manufacturer's Name ...........: Trackimo INC. Address ..................................: 680 Central Ave Cedarhurst, New York 11516 United States Product Description Product Name .........................: GPS Tracker Brand Name ...........................: Trackimo, Tracki Model Name ...........................: TRKI005-C Series Model(s) .....................: N/A Standards ..............................: FCC Part15.247 Test Procedure .......................: ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ............................................ : Date of receipt of test item ...................... : 20 Nov. 2025 Date (s) of performance of tests ............. : 20 Nov. 2025 ~ 09 Dec. 2025 Date of Issue ........................................... : 09 Dec. 2025 Test Result ............................................... : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 54 Report No.: STS2511172W05 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 20 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 21 4.6 TEST RESULTS 22 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 29 5.1 LIMIT 29 5.2 TEST PROCEDURE 29 5.3 TEST SETUP 29 5.4 EUT OPERATION CONDITIONS 29 5.5 TEST RESULTS 29 6. POWER SPECTRAL DENSITY TEST 30 6.1 LIMIT 30 6.2 TEST PROCEDURE 30 6.3 TEST SETUP 30 Page 4 of 54 Report No.: STS2511172W05 Table of Contents Page 6.4 EUT OPERATION CONDITIONS 30 6.5 TEST RESULTS 30 7. BANDWIDTH TEST 31 7.1 LIMIT 31 7.2 TEST PROCEDURE 31 7.3 TEST SETUP 31 7.4 EUT OPERATION CONDITIONS 31 7.5 TEST RESULTS 31 8. PEAK OUTPUT POWER TEST 32 8.1 LIMIT 32 8.2 TEST PROCEDURE 32 8.3 TEST SETUP 33 8.4 EUT OPERATION CONDITIONS 33 8.5 TEST RESULTS 33 9. ANTENNA REQUIREMENT 34 9.1 STANDARD REQUIREMENT 34 9.2 EUT ANTENNA 34 APPENDIX 1-TEST DATA 35 DUTY CYCLE 35 MAXIMUM PEAK CONDUCTED OUTPUT POWER 38 -6DB BANDWIDTH 41 MAXIMUM POWER SPECTRAL DENSITY LEVEL 44 BAND EDGE 47 CONDUCTED RF SPURIOUS EMISSION 50 APPENDIX 2- EUT TEST PHOTO 54 Page 5 of 54 Report No.: STS2511172W05 Revision History Rev. Issue Date Report No. Effect Page Contents 00 09 Dec. 2025 STS2511172W05 ALL Initial Issue Page 6 of 54 Report No.: STS2511172W05 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- Note: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 54 Report No.: STS2511172W05 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52dB 5 All emissions, radiated 1G-18GHz ±3.48dB 6 All emissions, radiated>18GHz ±4.18dB 7 Conducted Emission (9KHz-150KHz) ±2.48dB 8 Conducted Emission (150KHz-30MHz) ±2.52dB 9 Occupied Channel Bandwidth ±3.6% 10 Power Spectral Density, conducted ±1.214dB 11 Duty Cycle ±3.2% Page 8 of 54 Report No.: STS2511172W05 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name GPS Tracker Brand Name Trackimo, Tracki Model Name TRKI005-C Series Model(s) N/A Model Difference N/A Product Description The EUT is a GPS Tracker Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Radio Technology: BLE Bluetooth Configuration: …

Text truncated - open the document above for the full version.

Test Report

L1 WIFI2.4G WIFI BTBT ModelVcurve2 Shenzhen Hengxiangtong Antenna Technology Co., Ltd. Manufacter nna posit Frequency MAIN ANT FDD1 2 3 4 5 7 8 12 17 18 19 20 25 26 28 ( A+B) TDD:38 40 41-100M GPS ve Gaiak GaEffiAve Gaineak GaiEffiAve Gaineak GaiEffi (dB)(dBi)(%)(dB)(dBi)(%)(dB)(dBi)(%) 800-26-220.252300-10.4-7.479.07700-21.15-17.30.77 810-25-210.332320-9.84-6.4410.37710-20.23-16.40.95 820-24-200.362340-9.22-5.8911.96720-19.3-15.41.17 830-24-200.422360-8.59-5.3213.83730-18.75-14.71.33 840-23-190.542380-8.16-5.1715.28740-18.21-14.21.51 850-22-180.632400-7.42-418.11750-17.49-13.51.78 860-22-180.72420-6.94-3.3520.25760-16.77-132.1 870-20-170.962440-6.14-2.5624.3770-16.44-12.92.27 880-19-161.182460-5.61-2.1827.47780-16.22-12.82.39 890-18-151.522480-5.15-1.5130.56790-16.13-12.62.44 900-17-142.092500-4.58-0.81 34.86800-15.88-12.62.58 910-15-122.822520-4.21-0.4337.96 920-14-113.72540-4.03-0.5939.56 930-13-9.75.162560-3.77-0.2341.98 940-12-8.66.592580-3.30.3446.75 950-11-8.37.462600-3.150.7648.43 960-12-8.76.862620-2.990.950.23 1700-9.3-611.872640-3.170.6648.24 1720-9.5-5.911.282660-3.52-0.0144.47 1740-9.6-6.210.972680-3.82-0.3841.54 1760-9.4-6.211.372700-3.99-0.5139.93 1780-9.3-6.411.78 1800-8.9-612.9 1820-8.6-5.513.84 1840-8.5-5.314.11 1860-8.2-5.115.16 1880-8.1-4.815.45 1900-7.6-417.54 1920-6.9-3.620.3 1940-6.3-3.323.4 1960-6-325.34 1980-5.5-2.328.24 2000-5.5-2.428.13 2020 -6.4-3.722.9 2040-7.8-4.216.75 2060-8.8-4.913.06 2080-9.2-6.111.92 2100-9.5-6.711.33 2120-9.8-7.410.43 2140-10-7.89.93 2160-10-8.19.45 2180-11-8.78.65 (MHz)(MHz)(MHz) (800~960,1710~2700)MHz(700~800)MHz 700MHZ 750MHZ 800MHZ 850MHZ 960MHZ 1700MHZ 2180MHZ 2300MHZ 2700MHZ Ave GainPeak GainEffi (dB)(dBi)(%) 1560 -7.02-3.3719.86 1565 -6.85-3.3220.68 1570 -6.80-3.3620.88 1575 -6.90-3.3320.40 1580 -7.09-3.5619.55 1585 -7.35-3.9118.40 1590 -7.69-4.1817.02 GPS (MHz) Ave GainPeak GainEffi (dB)(dBi)(%) 2400 -8.16-5.6715.29 2410 -8.01-5.4915.80 2420 -7.69-5.2317.02 2430 -7.50-5.0017.78 2440 -7.15-4.7719.28 2450 -6.96-4.6120.13 2460 -6.79-4.4920.92 2470 -6.65-4.5521.62 2480 -6.46-4.4422.57 2490 -6.37-4.4523.09 2500 -6.27-4.3223.60 2400MHZ BT (MHz) 2500MHZ Ave GainPeak GainEffi (dB)(dBi)(%) 2400-12.20-8.066.02 2410-12.39-7.975.77 2420-12.28-7.795.92 2430-12.18-7.576.05 2440-12.13-7.316.13 2450-12.00-7.316.31 2460-12.10-7.206.17 2470-12.07-7.306.21 2480-12.05-7.066.23 2490-12.03-7.156.26 2500-11.98-7.176.34 2400MHZ 2.4G WiFi (MHz) 2500MHZ

RF Exposure Info

       !"#$"% &'()*+,'-./01222131441567819::;<-:.00'='>'?@'2A)B*'CD EFGHIJKLM NOHFPPNJOQ R SRJILK IT UK SOGNVLPPJRGNSROTWGOFJLOOF WRGOO NSSRJXPJVYZ[\EF GNVJRMOGJNKJNOGN IF R GNGHOJQ LH I JNP]VJROF SLRSJH VJRWFGKFGOGHHLQMGOO INIGHNJOOJQ R P H IGNWFJP JRSROWGOFJLOWRGOO NSSRJXPJVYZ[\ 3 9        !""#"$ %&'()*+&,-./011102033045670899:;,9-//&<&=&>?&1@(A)&BC DEFGHIJKL MNGEOOMINP Q RQIHKJ HS TJ RNFMUKOOIQFMRQNSVFNEIKNNE VQFNN MRRQIWOIUXYZ[DE FMUIQLNFIMJIMNFM HE Q FMFGNIP KG H IMO\UIQNE RKQRIG UIQVEFJEFNFGGKPLFNN HMHFGMINNIP Q O G HFMVEIO IQRQNVFNEIKNVQFNN MRRQIWOIUXYZ[ ]^_`abcdec`fefgh ijklmknop qrs tkuvwxykzkj{xwwxyxwp| j }~ €nmowxyxwp|‚ƒ„…{ jklmxjk{kv †mjkjklmxjk{kv†mjk ‡ˆ‰Š‡‹Œ‡‰Ž‰‹ ‰‡‰Ž ‰‰ˆ‹‘‡‰Ž‰‹ Œ‘‡‰Ž ’ˆ‰ˆŠ‹“‡‰Ž‰‹Œ’‡‰Ž “ˆ‰ˆˆ‹ˆ‡‰Ž‰‹ ŒŠ‡‰Ž ˆˆˆ‹‘‡‰Ž‰‹Œ“‡‰Ž Œ‰‰ˆˆ‹‰‡‰Ž‡‹ ‰ˆ‡‰Ž Œ‡ˆˆˆ‹‰‡‰Ž‡‹ ‰Š‡‰Ž ‡’ˆ‰ˆ’‹‰‡‰Ž‡‹ ‰‡‰Ž ‡Š‡‰ˆ‹‡‰Ž‡‹ ’‰‡‰Ž ‡‰‰ˆ‹‡‰Ž ˆˆ‹ ‡‹ˆ‘‡‰Ž ‡ ‹’Œ ‡Œ‰‰ˆ‹‡‰Ž‡‹ ˆ‘‡‰Ž ‘‰‰‰ˆ‹‡‰Ž‡‹ ˆ‘‡‰Ž ‘‡‰‰ˆ‹‘‡‰Ž‡‹ Š‘‡‰Ž ‘‰‰ˆ‘‹Œ‡‰Ž‡‹ ‡‡‰Ž ‘’ˆ‰ˆ‘‹“‡‰Ž‡‹ Œˆ‡‰Ž ‘Љ‰ˆ‘‹ˆ‡‰Ž‘‹ ‡Š‡‰Ž ‰‰‰ˆ‘‹‰‡‰Ž‘‹ “‡‰Ž ‰‰ˆ‡‹Š‡‰Ž‹ ‰‡‰Ž ˆ‰‰ˆ‡‹‡‰Ž‹ ‡‡‰Ž “‰‰ˆ‡‹‰‡‰Ž‹ ˆˆ‡‰Ž Œ‰‰ˆ‰‹‡‰Ž‹ “‡‰Ž ’‘‰‰ˆ‰‹’‡‰Ž’‹ ‡‡‰Ž ’Љ‰’Œ‹‡‰Ž’‹ Љ‡‰Ž ’Œ‰‰’Œ‹’‡‰Ž’‹ Œˆ‡‰Ž ˆ‘‰‰’Œ‹‰‡‰Žˆ‹ ‰‡‰Ž ˆ‰‰’‹Œ‡‰Žˆ‹ ’‘‡‰Ž ˆ’‰‰’‹“‡‰Žˆ‹ ˆ‡‰Ž ˆˆ‰‰’‹Š‡‰Žˆ‹ Šˆ‡‰Ž ˆŠ‰‰’‹ˆ‡‰Žˆ‹““‡‰Ž ˆ‰‰’‹‘‡‰ŽŠ‹ ‰‰‡‰Ž 3 9        !"#$"% &'()*+,'-./01222131441567819::;<-:.00'='>'?@'2A)B*'CD EFGHIJKLM NOHFPPNJOQ R SRJILK IT UK SOGNVLPPJRGNSROTWGOFJLOOF WRGOO NSSRJXPJVYZ[\EF GNVJRMOGJNKJNOGN IF R GNGHOJQ LH I JNP]VJROF SLRSJH VJRWFGKFGOGHHLQMGOO INIGHNJOOJQ R P H IGNWFJP JRSROWGOFJLOWRGOO NSSRJXPJVYZ[\ ^_`_ab`cbdebfghicej`eh klmnogpaqr psntlkuavwxyz_{ pok|avxvp}gwww c~€~k‚c~ƒ„…†‡ˆ‰„Š‹ŒŠ‹ŽŒrrw~unvz h~lnt‘|lmt~’k“‘tlont“~€~vyyuu on‘ntok“€l~kt”•uux‚•uu –kkt‘ntk“€l~kt”•uux‚•uux —•ruu ˜o€t‘‚v yy_f— et’€l’kmoyu c~€~bu’onl€oy™xšv› cn|bu’onl€oy™xšv› cn|f€u~~l‚wyš^yœ žŸ ¡Ÿ¢£¤ ¥¦§ ̈©ª«¬­® ̄°© ̄®± ̈²©ª«¬­® ̄°© ̄®± ³Ÿ ́ μ¡žŸ¶³Ÿ ́μ¡žŸ¶ · ¹¹ 3 z » 43.33 (4.33) 21.59 (2.16) 9        !"#$"# %&'()*+&,-./011102033045670899:;,9-//&<&=&>?&1@(A)&BC DEFGHIJKL MNGEOOMINP Q RQIHKJ HS TJ RNFMUKOOIQFMRQNSVFNEIKNNE VQFNN MRRQIWOIUXYZ[DE FMUIQLNFIMJIMNFM HE Q FMFGNIP KG H IMO\UIQNE RKQRIG UIQVEFJEFNFGGKPLFNN HMHFGMINNIP Q O G HFMVEIO IQRQNVFNEIKNVQFNN MRRQIWOIUXYZ[ ]  ^_ ` abcdefghijcffklmjnggi opqrstuv twxyqrvqzu `{up|{xvpyty} `z~t ~tuvq|qx{vqzuz€ pyytuv {qy{vqzu {vt t‚v{qy{vqzu {vt jƒ„…nkhi†f „ ‡ˆ j‰Š‹ŒŽjƒ„ ‡k‘d’kig’“‰†”k‘ lgbcdlg’“ ‡k‘d’kig’“‰†”k‘ lgbcdlg’“ •–„–jƒ —˜g™išgh”n‡gl™d†h‹‰ƒ ‡k‘d’kig’“‰†”k‘ lgbcdlg’“ ‡k‘d’kig’“‰†”k ‘ lgbcdlg’“ ‰gi›†lœƒhk‘mgl —†n’gžj”n›kl Ÿ‡„ Š ‹Œ  ŠŒ  ¡ ‰gi›†lœƒhk‘mglƒ¢d‘ghi£¤‹aj„¥¡ ‹ ŠŠŒ  ‰gi›†lœƒhk‘mgl¦ •k‘d§lkid†hœdi —†n’gžj”n›kl Ÿ‡ ̈Ÿ ‹¤ ŠŠ ‹¤Œ  ‰gi›†lœƒhk‘mgl¦ •k‘d§lkid†hœdi ©…¤‹‹ª‹¡ ‹ƒŠŒ  ŠŒ  £ •k‘degl™„dici†m†j‰Ž£‹ —g«glgh”g…l†§g„‡ˆ j‰¡ŠŒŠa…ˆ–‹‹‹ŠŒ  „c‘idfgigl¬gdin‘gm ŠŠ £Š Œ  jd¢hk‘ˆghglki†l —†n’gžj”n›kl j„š Š¤Ž¡Œ  ƒfe‘d«dgl„‡ˆ „ –ª­ ̈ ‹ ̈• ̈ •nklk”igldg’eld†li† ig™i“‰†”k‘lgbcdlg’“ •nklk”igldg’eld†li† ig™i“‰†”k‘lgbcdlg’“ …†›gl„gigl‰® ̈­jš¤Š£ŠŠ‹Œ  ŠŒ  ¡ …†›gl„gigl —†n’gžj”n›kl ‰—‡ª ‹ ‹Ž ̈¤ŠŠŒ  ªdlg”id†hk‘•†ce‘gl¬lmiklФ Š‹Š¡£ •nklk”igldg’eld†li† ig™i“‰†”k‘lgbcdlg’“ •nklk”igldg’eld†li† ig™i“‰†”k‘lgbcdlg’“ ˜gfeglkiclgŒ©cfd’dim jgh™†l ˜g™i†Š¡©Š¡¡ ¤‹ Œ  ŠŒ  ¡ ŠŒ  ¤ ¤Œ  ¤ ŠŒ  Œ  ¤ Š Œ  Š ‹ ¡Œ    Œ  ‹ ŠŠŒ  ¤ 3 9 Page: 1/13 Ref : ACR.14.20.24.BES.A SHENZHEN STS TEST SERVICES CO., LTD. 1/F, BUILDING 2, ZHUOKE SCIENCE PARK, CHONGQING ROAD FUYONG, BAO’ AN DISTRICT, SHENZHEN,CHINA MVG COMOSAR REFERENCE DIPOLE FREQUENCY: 2300 MHZ SERIAL NO.: SN 08/21 DIP2G 300-550- Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 02/14/2024 Accreditations #2-6789 and #2-6814 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited SAR reference dipole calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions. SAR Reference Dipole Calibration Report Page: 1/13 Page: 1/13 Page: 2/13 ACR.14.20.24.BES.A Ref: SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.14.20.24.BES.A Page: 3/13 Template_ACR.DDD.N.YY.MVGB.ISSUE_SAR Reference Dipole vG This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or p…

Text truncated - open the document above for the full version.

RF Exposure Info

Ref : ACR.262.4.2.MVGB.A SHENZHEN STS TEST SERVICES CO., LTD. 1/F., BUILDING 2, ZHUOKE SCIENCE PARK,No.190, CHONGQING ROAD,FUYONG STREET, BAO’ AN DISTRICT, SHENZHEN,GUANGDONG,CHINA MVG COMOSAR REFERENCE DIPOLE FREQUENCY: 750 MHZ SERIAL NO.: SN 30/14 DIP0G750-331 SAR Reference Dipole Calibration Report Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise - 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: Summary: Page: 1/11 3 07/04/2023 Accreditations #2-6789 and #2-6814 Scope available on www.cofrac.fr This document presents the method and results from an accredited SAR reference dipole calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions. SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262.4.2.MVGB.A Customer Name Distribution : Shenzhen STS Test Services Co., Ltd. Name Function Date Signature Prepared by : Jérôme LUC Technical Manager 7/0 /202 Checked by : Jérôme LUC Technical Manager Approved by : Yann Toutain Laboratory Director Issue Date Modifications A Initial release Name Jérôme LUC Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3 4 7/0 /202 3 4 7/0 /202 3 4 7/0 /202 3 4 3 SAR REFERENCE DIPOLE CALIBRATION REPORT TABLE OF CONTENTS 1 Introduction ................................................................................................................ 4 2 Device Under Test ..................................................................................................... 4 3 Product Description ................................................................................................... 4 3.1 General Information _______________________________________________________ 4 4 Measurement Method ................................................................................................ 5 4.1 Return Loss Requirements __________________________________________________ 5 4.2 Mechanical Requirements ___________________________________________________ 5 5 Measurement Uncertainty .......................................................................................... 5 5.1 Return Loss ______________________________________________________________ 5 5.2 Dimension Measurement ___________________________________________________ 5 5.3 Validation Measurement ____________________________________________________ 5 6 Calibration Measurement Results .............................................................................. 6 6.1 Return Loss and Impedance In Head Liquid ____________________________________ 6 6.2 Return Loss and Impedance In Body Liquid ____________________________________ 6 6.3 Mechanical Dimensions ____________________________________________________ 6 7 Validation measurement ............................................................................................ 7 7.1 Head Liquid Measurement __________________________________________________ 7 7.2 SAR Measurement Result With Head Liquid ____________________________________ 8 7.3 Body Liquid Measurement __________________________________________________ 9 7.4 SAR Measurement Result With Body Liquid __________________________________ 10 8 List of Equipment .................................................................................................... 11 Page: 3/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 1 INTRODUCTION This document contains a summary of the requirements set forth by the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations and the measurements that were performed to verify that the product complies with the fore mentioned standards. 2 DEVICE UNDER TEST Device Under Test Device Type COMOSAR 750 MHz REFERENCE DIPOLE Manufacturer MVG Model SID750 Serial Number SN 30/14 DIP0G750-331 Product Condition (new / used) Used A yearly calibration interval is recommended. 3 PRODUCT DESCRIPTION 3.1 GENERAL INFORMATION MVG’s COMOSAR Validation Dipoles are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. The product is designed for use with the COMOSAR test bench only. Figure 1 – MVG COMOSAR Validation Dipole Page: 4/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 4 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards provide requirements for reference dipoles used for system validation measurements. The following measurements were performed to verify that the product complies with the fore mentioned standards. 4.1 RETURN LOSS REQUIREMENTS The dipole used for SAR system validation measurements and checks must have a return loss of -20 dB or better. The return loss measurement shall be performed against a liquid filled flat phantom, with the phantom constucted as outlined in the fore mentioned standards. 4.2 MECHANICAL REQUIREMENTS The IEEE Std. 1528 and CEI/IEC 62209 standards specify the mechanical components and dimensions of the validation dipoles, with the dimensions frequency and phantom…

Text truncated - open the document above for the full version.

RF Exposure Info

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. SAR Test Report Report No.: STS2511172H02 Issued for Trackimo INC. 680 Central Ave Cedarhurst, New York 11516 United States Product Name: GPS Tracker Brand Name: Trackimo, Tracki Model Name: TRKI005-C Series Model(s): N/A FCC ID: 2AAI6-TRKI005-C Test Standard: ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 Max. Report SAR (10&1g) Body: 1.481 W/kg(1g) Page 2 of 97 Report No.: STS2511172H02 TEST REPORT CERTIFICATION Applicant’s name ................. : Trackimo INC. Address ................................. : 680 Central Ave Cedarhurst, New York 11516 United States Manufacturer's Name .......... : Trackimo INC. Address ................................. : 680 Central Ave Cedarhurst, New York 11516 United States Product description Product name ........................ : GPS Tracker Brand name ......................... : Trackimo, Tracki Model name ......................... : TRKI005-C Series Model(s) : .................... N/A Standards ............................. : ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 The device was tested by Shenzhen STS Test Services Co., Ltd. in accordance with the measurement methods and procedures specified in KDB 865664 The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of Test ........................................... : Date (s) of performance of tests ............. : 27 Nov.2025 ~ 28 Nov. 2025 Date of Issue .......................................... : 29 Dec. 2025 Test Result.............................................. : Pass Testing Engineer : (Xin.Liu) Technical Manager : (Shifan. Long) Authorized Signatory : (Bovey Yang) Page 3 of 97 Report No.: STS2511172H02 Table of Contents 1. General Information 5 1.1 EUT Description 5 1.2 Test Environment 7 1.3 Test Factory 7 2. Test Standards and Limits 8 3. SAR Measurement System 9 3.1 Definition of Specific Absorption Rate (SAR) 9 3.2 SAR System 9 4. Tissue Simulating Liquids 12 4.1 Simulating Liquids Parameter Check 12 5. SAR System Validation 16 5.1 Validation System 16 5.2 Validation Result 17 6. SAR Evaluation Procedures 18 7. EUT Test Position 19 7.1 Body-worn Position Conditions 19 7.2 SAR Test Exclusions Applied 20 8. Uncertainty 21 8.1 Measurement Uncertainty 21 9. Conducted Power Measurement 24 9.1 Test Result 24 10. EUT and Test Setup Photo 52 10.1 EUT Photo 52 10.2 Setup Photo 55 11. SAR Result Summary 57 11.1 Body SAR 57 11.2 Repeated SAR 59 11.3 Repeated SAR measurement 59 11.4 Simultaneous Multi-band Transmission Evaluation 61 12. Equipment List 62 Appendix A. System Validation Plots 63 Appendix B. SAR Test Plots 75 Appendix C. Probe Calibration and Dipole Calibration Report 97 Page 4 of 97 Report No.: STS2511172H02 Revision History Rev. Issue Date Report No. Effect Page Contents 00 29 Dec. 2025 STS2511172H02 ALL Initial Issue Page 5 of 97 Report No.: STS2511172H02 1. General Information Environmental evaluation measurements of specific absorption rate (SAR) distributions in emulated human head and body tissues exposed to radio frequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 1.1 EUT Description Product Name GPS Tracker Brand Name Trackimo, Tracki Model Name TRKI005-C Series Model N/A Model Difference N/A Sample number 251119021-4 Battery Model: SD852025P 1S1P Brand: N/A Rated Voltage: 3.8V Charge Limit Voltage: 4.35V Capacity: 800mAh Device Category Portable Product stage Production unit RF Exposure Environment General Population / Uncontrolled Hardware Version UCAT 217 SCH V1.1 Software Version W217_VCURVE2_E_T_V02_release_20251224_1510 3416 Frequency Range LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 7:2500 MHz ~ 2570 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 17: 704 MHz ~ 716 MHz LTE Band 25: 1850 MHz ~ 1915 MHz LTE Band 26: 814 MHz ~ 824 MHz / 824 MHz ~ 849 MHz LTE Band 38: 2570 MHz ~ 2620 MHz LTE Band 40: 2305 MHz ~ 2315 MHz / 2350 MHz ~ 2360 MHz LTE Band 41: 2496 MHz ~ 2690 MHz BLE: 2402 MHz to 2480 MHz Max. Reported SAR(1g): (Limit:1.6&4.0W/kg) Test distance: Body:5mm Band Mode Body Worn (W/kg) PCB LTE Band 2 1.421 PCB LTE B…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shlomo Shur(CTO)
[email protected]Fax: 7184250442

Technical Contact

Trackimo IncShlomo Shur
[email protected]

680 Central Ave, Cedarhurst · New York, New York, 11516 · United States

Test Firm

SHENZHEN STS TEST SERVICES CO.,LTD.Bovey Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions is 0.06W/kg and 1.48W/kg respectively.

Other Applications from Trackimo INC.

NickWatch V1 - FCC ID 2AAI6-NICKW001-2 - Trackimo INC.
2AAI6-NICKW001-2

NickWatch V1

Nov 08, 2023

Equipment Class

PCT - PCS Licensed Transmitter worn on body
GPS Tracker - FCC ID 2AAI6-TRKM110-T - Trackimo INC.
2AAI6-TRKM110-T

GPS Tracker

Dec 18, 2022

Equipment Class

PCB - PCS Licensed Transmitter
GPS Tracker - FCC ID 2AAI6TRKM010 - Trackimo INC.
2AAI6TRKM010

GPS Tracker

Sep 17, 2020

Equipment Class

PCB - PCS Licensed Transmitter
GPS Tracker - FCC ID 2AAI6TRKM110 - Trackimo INC.
2AAI6TRKM110

GPS Tracker

Aug 20, 2020

Equipment Class

PCB - PCS Licensed Transmitter
GPS Tracker - FCC ID 2AAI6-VST001 - Trackimo INC.
2AAI6-VST001

GPS Tracker

Apr 12, 2020

Equipment Class

DTS - Digital Transmission System