FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Trackimo INC./
  3. 2AAI6-VST001

2AAI6-VST001GPS Tracker

Trackimo INC.
GPS Tracker - FCC ID 2AAI6-VST001 - Trackimo INC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 12, 2020
Application Purpose
Original Equipment
Date of Application
Apr 12, 2020
Equipment Note
GPS Tracker
Frequency Range
2402.00000000 - 2480.00000000
Company
Trackimo INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

VST001 Band PSI EU4 Rev 1.0 1 C2 General Product Name : GPS Tracker Model Name :VST001 Manufacture: Trackimo INC. VST001 Band PSI EU4 Rev 1.0 2 C2 General [VST001] (model ID) Safety and Warranty information EN | DE | ES | IT VST001 Band PSI EU4 Rev 1.0 3 C2 General EN Product Safety Information Please read this safety information before you use the device. Following the warnings will help prevent injury to yourself or others and damage to your device. Additional safety warnings may be given for the operation of specific Apps on your device, you should also follow these instructions. Pictograms and Graphic Symbols Read the Safety Information section of this user guide before using this device. Failure to comply with safety warnings can result in serious injury. This device is not intended for use by young children. If you allow a child to use it ensure the child is strictly supervised. This device contains small parts which are a choking hazard Keep away from pacemakers and other personal medical devices Switch off when instructed in hospitals and medical facilities Switch off when instructed in aircrafts and airport Do not take this device near explosive environments Do not use while refuelling or near gas or flammable liquids Do not dispose of this device or its battery in a fire VST001 Band PSI EU4 Rev 1.0 4 C2 General Avoid contact with magnetic media Avoid Extreme Temperatures Do not try and disassemble This device will not communicate with emergency services Only use approved accessories This device may produce a bright or flashing light RF Exposure This device contains a radio transmitter and a receiver. When it is ON, it receives and transmits RF energy. Specific Absorption Rate (SAR) Your mobile device is a radio transmitter and receiver. It is designed not to exceed the limits for exposure to radio waves recommended by international guidelines. These guidelines were developed by the independent scientific organisation ICNIRP and include safety margins designed to assure the protection of all persons, regardless of age and health. The guidelines use a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit for mobile devices is 2 W/kg. The highest SAR value for this device when tested complied with this limit. Regulatory information VST001 Band PSI EU4 Rev 1.0 5 C2 General The following safety approvals and notices apply in specific regions as noted. Here by, the manufacturer declares that the wireless device is in compliance with the essential requirements and other relevant provisions of the Radio Equipment Directive 2014/53/EU. A full copy of the Declaration of Conformity can be found at [insert URL here] Product Handling You alone are responsible for how you use your device and any consequences of its use. Use of your device is subject to safety measures designed to protect users and their environment. • Your device has an IP67 water and dust resistance rating. However, the device is not designed for swimming, diving, or prolonged submersion in water. * IP67 tests are carried out in accordance with [IEC 60529] • Do not expose your device or its accessories to extreme temperatures, minimum –20 and maximum +45 degrees Celsius. Any temperatures below -20 degrees Celsius the display module / battery may have reduced function due to freezing. After recovering to room temperature full function will be regained. Do not leave the device in your car along, because temperatures in parked cars can exceed this range. • Do not expose your device or its accessories to open flames or lit tobacco products. • Do not use your device in a sauna or steam room. VST001 Band PSI EU4 Rev 1.0 6 C2 General • Do not charge your device while it is wet. • Do not drop, throw or try to bend your device or its accessories. • Do not use harsh chemicals, cleaning solvents, or aerosols to clean the device or its accessories. • Do not paint your device or its accessories. • Do not attempt to disassemble your device or its accessories, only authorised personnel must do so. • Please check local regulations for disposal of electronic products. • Do not carry your device in your back pocket as it could break when you sit down. Small Children Do not leave your device and its accessories within the reach of small children or allow them to play with it. They could hurt themselves or others, or may accidentally damage the device. Your device contains small parts with sharp edges that may cause an injury or which could become detached and create a choking hazard. Demagnetisation To avoid the risk of demagnetisation, do not allow electronic devices or magnetic media close to your device for a long time. Avoid other magnetic sources as these may cause the internal magnetometer or other sensors to malfunction and provide incorrect data. Seizures/Blackouts This device is capable of producing bright flashing lights. VST001 Band PSI EU4 Rev 1.0 7 C2 General Electrical Safety Use only approved accessories and chargers. Do not connect with incompatible products or accessories. Take care not to touch or allow metal objects, such as coins or key rings, to contact or short-circuit the battery terminals, charger, and device charging point or any electrical contacts on accessories. Do not touch your charger with wet hands. Doing so may cause an electric shock. Do not touch the power cord with wet hands or disconnect the charger by pulling the cord. Doing so may result in electrocution. Faulty and Damaged Products Do not attempt to disassemble the device or its accessory. Only qualified personnel should service or repair the device or its accessory. If your device or its accessory has been submerged in water or other liquid, punctured, or subjected to a severe fall, do not use it until you have taken it to be checked at an authorised service centre. Battery Handling and Safety (For Products with Non-removable Battery) The battery in this device is not user removable. Do not make any attempt to remove the batt…

Text truncated - open the document above for the full version.

Cover Letter(s)

Trackimo INC. TCBJ FORM-4 Issued by: TCB Administrator Revision 6 12/06/10 2020.04.08 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, Trackimo INC. hereby authorize (Shenzhen STS Test Services Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Name: Shlomo Shur Signature:

Cover Letter(s)

Trackimo INC. TCBJ FORM-4 Issued by: TCB Administrator Revision 6 12/06/10 2020.04.08 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (GPS Tracker / VST001 /FCC ID: 2AAI6-VST001) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the • Schematics • Block diagram • Operation description • Tune up Procedure • Part List These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. required to be submitted with this application be permanently withheld from public review. Please contact me if there is any information you may need. Sincerely, Name: Shlomo Shur Signature:

External Photos

Page 1 of 4 Report No.: STS2003192 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Page 2 of 4 Report No.: STS2003192 Photo 3 Photo 4 Page 3 of 4 Report No.: STS2003192 Photo 5 Photo 6 Page 4 of 4 Report No.: STS2003192 Photo 7

ID Label/Location Info

FCC Label GPS Tracker Model name: VST001 FCC ID: 2AAI6-VST001 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Page 1 of 4 Report No.: STS2003192 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 BT Antenna GPS Antenna GSM Antenna Page 2 of 4 Report No.: STS2003192 Photo 3 Photo 4 Page 3 of 4 Report No.: STS2003192 Photo 5 Photo 6 Page 4 of 4 Report No.: STS2003192 Photo 7

RF Exposure Info

VST001_SAR Setup photo Body Front side(separation distance is 5mm) Body Back side(separation distance is 5mm)

RF Exposure Info

Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from STS, All Test Data Presented in this report is only applicable to presented Test sample. ShenZhen STS Test Services Co.,Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:[email protected] S T L A B S Testing Engineer : (Aaron Bu) Technical Manager : (Jason Lu) Authorized Signatory : (Vita Li) SAR Dipole Performance Measurement Report EUT Type: SAR Validation Dipole and Waveguide Model Name: DIP 0G835-332, DIP 1G900-333 Brand Name: SATIMO Test Conclusion: Pass Test Date: 14 Aug. 2019~15 Aug. 2019 Date of Issue: 17 Aug. 2019 ISSUED BY Shenzhen STS Test Services Co., Ltd. 1. Equipment List Kind of Equipment Manufacturer Type No. Serial No. Last Calibration Calibrated Until PC Acer N/A N/A N/A N/A E-Field Probe MVG SSE5 SN 14/16 EP309 2018.12.13 2019.12.12 Dielectric Probe Kit MVG SCLMP SN 32/14 OCPG67 2018.12.01 2019.11.30 Phantom1 MVG SAM SN 32/14 SAM115 N/A N/A Phantom2 MVG SAM SN 32/14 SAM116 N/A N/A Attenuator Agilent 99899 DC-18GHz N/A N/A Directional coupler Narda 4226-20 3305 N/A N/A Network Analyzer Agilent 8753ES US38432810 2019.03.02 2020.03.01 Multi Meter Keithley Multi Meter 2000 4050073 2018.10.13 2019.10.12 Signal Generator Agilent N5182A MY50140530 2018.10.16 2019.10.15 Power Amplifier DESAY ZHL-42W 9638 2018.10.13 2019.10.12 Power Meter R&S NRP 100510 2018.10.26 2019.10.25 Power Sensor R&S NRP-Z11 101919 2018.10.13 2019.10.12 Power Sensor Agilent E9301A MY41497725 2018.10.13 2019.10.12 hygrothermograph MiEO HH660 N/A 2018.10.11 2019.10.10 Thermograph Elitech RC-4 S/N EF7176501537 2018.10.15 2019.10.14 ISSUED BY Shenzhen STS Test Services Co., Ltd. 2.<Justification of the extended calibration> Referring to KDB 865664 D01, if dipoles are verified in return loss<-20dB, (within 20% of prior calibration),and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Body 835 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.08.15 -23.87 - 49.0 - 2018.08.15 -22.21 -6.95 52.59 3.59 2019.08.14 -24.25 9.19 52.65 0.06 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 835MHz ISSUED BY Shenzhen STS Test Services Co., Ltd. Body 1900 MHz Date of Measurement Return Loss (dB) Delta (%) Impedance Delta(ohm) 2017.08.15 -20.22 - 48.8 - 2018.08.16 -23.26 15.03 47.11 -1.79 2019.08.15 -24.15 3.83 48.71 1.60 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. <Dipole Verification Data> Body 1900 MHz

RF Exposure Info

Ref : ACR.345.3.19.SATU.A SHENZHEN STS TEST SERVICES CO., LTD. 1/F, BUILDING 2, ZHUOKE SCIENCE PARK, CHONGQING ROAD FUYONG, BAO’ AN DISTRICT, SHENZHEN,CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 41/18 EPGO334 Calibrated at MVG US 2105 Barrett Park Dr. - Kennesaw, GA 30144 Calibration Date: 06/04/2019 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in MVG USA using the CALISAR / CALIBAIR test bench, for use with a COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.345.3.19.SATU.A Page: 2/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Jérôme LUC Product Manager 12/11/2019 Checked by : Jérôme LUC Product Manager 12/11/2019 Approved by : Kim RUTKOWSKI Quality Manager 12/11/2019 Customer Name Distribution : Shenzhen STS Test Services Co., Ltd. Issue Date Modifications A 12/11/2019 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.345.3.19.SATU.A Page: 3/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Measurement Results .............................................................................. 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment .................................................................................................... 10 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.345.3.19.SATU.A Page: 4/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number SN 41/18 EPGO334 Product Condition (new / used) New Frequency Range of Probe 0.45 GHz-6GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.191 M Dipole 2: R2=0.216 M Dipole 3: R3=0.197 M A yearly calibration interval is recommended. 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEEE 1528 and CEI/IEC 62209 standards. Figure 1 – MVG COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEEE 1528 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.345.3.19.SATU.A Page: 5/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole with the dipole mounted under the flat phantom in the test configuration suggested for system validations and checks. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. The hemispherical isotropy is determined by inserting the probe in a thin plastic box filled with tissue-equivalent liquid, with the plastic box illuminated with the fields from a half wave dipole. The…

Text truncated - open the document above for the full version.

RF Exposure Info

Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from STS, All Test Data Presented in this report is only applicable to presented Test sample. ShenZhen STS Test Services Co.,Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:[email protected] FCC SAR TEST REPORT Report No.: STS2003192H02 Issued for Trackimo INC. 450 Seventh Avenue, Suite 1408, New York, United States Product Name: GPS Tracker Brand Name: N/A Model Name: VST001 Series Model: N/A FCC ID: 2AAI6-VST001 Test Standard: ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 ( 2.1093) IEEE 1528: 2013 Max. Report SAR (1g): Body: 0.413 W/kg S T L A B S Page 2 of 37 Report No.: STS2003192H02 Test Report Certification Applicant’s name ................. : Trackimo INC. Address ................................. : 450 Seventh Avenue, Suite 1408, New York, United States Manufacture's Name ............ : Trackimo INC. Address ................................. : 450 Seventh Avenue, Suite 1408, New York, United States Product description Product name ........................ : GPS Tracker Brand name ......................... : N/A Model name ......................... : VST001 Series Model .......................... : N/A Standards ............................. : ANSI/IEEE Std. C95.1-1992 FCC 47 CFR Part 2 ( 2.1093) IEEE 1528: 2013 The device was tested by Shenzhen STS Test Services Co., Ltd. in accordance with the measurement methods and procedures specified in KDB 865664 The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of Test Date (s) of performance of tests ............. : 16 Mar. 2020~17 Mar. 2020 Date of Issue .......................................... : 22 Mar. 2020 Test Result.............................................. : Pass Testing Engineer : ( Aaron Bu) Technical Manager : (Jason Lu) Authorized Signatory : (Vita Li) Page 3 of 37 Report No.: STS2003192H02 Table of Contents 1.General Information 5 1.1 EUT Description 5 1.2 Test Environment 6 1.3 Test Factory 6 2.Test Standards and Limits 7 3. SAR Measurement System 8 3.1 Definition of Specific Absorption Rate (SAR) 8 3.2 SAR System 8 4. Tissue Simulating Liquids 11 4.1 Simulating Liquids Parameter Check 11 5. SAR System Validation 13 5.1 Validation System 13 5.2 Validation Result 13 6. SAR Evaluation Procedures 14 7. EUT Test Position 15 8. Uncertainty 16 8.1 Measurement Uncertainty 16 8.2 System validation Uncertainty 17 9. Conducted Power Measurement 18 9.1 Test Result 18 9.2 Tune-up Power 19 9.3 SAR Test Exclusions Applied 20 10. EUT and Test Setup Photo 21 10.1 EUT Photo 21 10.2 Setup Photo 24 11. SAR Result Summary 26 11.1 Body SAR 26 12. Equipment List 28 Appendix A. System Validation Plots 29 Appendix B. SAR Test Plots 33 Appendix C. Probe Calibration and Dipole Calibration Report 37 Page 4 of 37 Report No.: STS2003192H02 Revision History Rev. Issue Date Report No. Effect Page Contents 00 22 Mar. 2020 STS2003192H02 ALL Initial Issue Note: Format version of the report - V01 Page 5 of 37 Report No.: STS2003192H02 1. General Information Environmental evaluation measurements of specific absorption rate (SAR) distributions in emulated human head and body tissues exposed to radio frequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 1.1 EUT Description Product Name GPS Tracker Brand Name N/A Model Name VST001 Series Model N/A FCC ID 2AAI6-VST001 Model Difference N/A Battery Rated Voltage: 3.8V Charge Limit: 4.35V Capacity: 500mAh Device Category Portable Product stage Production unit Exposure Environment General Population / Uncontrolled IMEI N/A Hardware Version V0.2 Software Version V21 Frequency Range GSM 850: 824.2~848.8MHz PCS1900: 1850.2~1909.8MHz Bluetooth: 2402~2480MHz GPS: 1575.42MHz Max. Reported SAR(1g) (Limit:1.6W/kg) Band Mode Body (W/kg) PCB GSM 850 0.084 PCB GPRS 850 0.353 PCB GSM 1900 0.342 PCB GPRS 1900 0.413 DTS Bluetooth Note 0.007 1-g Sum SAR 0.420 FCC Equipment Class Licensed Portable Transmitter (PCB) Digital Transmission System (DTS) Operating Mode GSM: GSM Voice; GPRS Class 12 BLE: V4.0 Antenna Specification GSM: PIFA Antenna BT: PIFA Antenna Note: 1. Bluetooth SAR was estimated 2. The EUT battery must be fully charged and checked periodically during the test to ascertain uniform power Page 6 of 37 Report No.: STS2003192H02 1.2 Test Environment Ambient conditions in the SAR laboratory: Items Required Temperature (°C) 18-25 Humidity (%RH) 30-70 1.3 Test Factory ShenZhen STS Test Services Co.,Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration No.: 625569 IC Registration No.: 12108A A2LA Certificate No.: 4338.01 Page 7 of 37 Report No.: STS2003192H02 2. Test Standards and Limits No. Identity Document Title 1 47 CFR Part 2 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations 2 ANSI/IEEE Std. C95.1-1992 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz 3 IEEE Std. 1528-2013 Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques 4 FCC KDB 447498 D01 v06 Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies 5 FCC KDB 865664 D01 v01r04 SAR Measurement 100 MHz to 6 GHz 6 FCC KDB 865664 D02 v01r02 RF Exposure Reporting (A). Limits for Occupational/Controlled Exposure (W/kg) Whole-Body Partial-Body Hands, Wrists, Fe…

Text truncated - open the document above for the full version.

Test Report

Any reproduction of this document must be done in full. No single part of this document may be reproduced without permission from STS, All Test Data Presented in this report is only applicable to presented Test sample. Shenzhen STS Test Services Co., Ltd. A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:[email protected] RADIO TEST REPORT Report No.:STS2003192W06 Issued for Trackimo INC. 450 Seventh Avenue, Suite 1408, New York, United States Product Name: GPS Tracker Brand Name: N/A Model Name: VST001 Series Model: N/A FCC ID: 2AAI6-VST001 Test Standard: FCC Part 15.247 S T L A B S Page 2 of 44 Report No.: STS2003192W06 TEST RESULT CERTIFICATION Applicant’s Name ..................: Trackimo INC. Address ..................................: 450 Seventh Avenue, Suite 1408, New York, United States Manufacture's Name .............: Trackimo INC. Address ..................................: 450 Seventh Avenue, Suite 1408, New York, United States Product Description Product Name .........................: GPS Tracker Brand Name ..........................: N/A Model Name ...........................: VST001 Series Model ...........................: N/A Test Standards ......................: FCC Part15.247 Test Procedure .......................: ANSI C63.10-2013 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of STS, this document may be altered or revised by STS, personal only, and shall be noted in the revision of the document. Date of Test ............................................ : Date of receipt of test item ...................... : 10 Mar. 2020 Date (s) of performance of tests ............. : 10 Mar. 2020 ~ 25 Mar. 2020 Date of Issue ........................................... : 25 Mar. 2020 Test Result ............................................... : Pass Testing Engineer : (Chris Chen) Technical Manager : (Sean she) Authorized Signatory : (Vita Li) Page 3 of 44 Report No.: STS2003192W06 Table of Contents 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 12 2.6 EQUIPMENTS LIST 13 3. EMC EMISSION TEST 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.2 TEST PROCEDURE 15 3.3 TEST SETUP 15 3.4 EUT OPERATING CONDITIONS 15 3.5 TEST RESULTS 16 4. RADIATED EMISSION MEASUREMENT 18 4.1 RADIATED EMISSION LIMITS 18 4.2 TEST PROCEDURE 20 4.3 TEST SETUP 21 4.4 EUT OPERATING CONDITIONS 21 4.5 FIELD STRENGTH CALCULATION 22 4.6 TEST RESULTS 23 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 30 5.1 LIMIT 30 5.2 TEST PROCEDURE 30 5.3 TEST SETUP 30 5.4 EUT OPERATION CONDITIONS 30 5.5 TEST RESULTS 31 6. POWER SPECTRAL DENSITY TEST 35 6.1 LIMIT 35 6.2 TEST PROCEDURE 35 6.3 TEST SETUP 35 Page 4 of 44 Report No.: STS2003192W06 Table of Contents 6.4 EUT OPERATION CONDITIONS 35 6.5 TEST RESULTS 36 7. BANDWIDTH TEST 38 7.1 LIMIT 38 7.2 TEST PROCEDURE 38 7.3 TEST SETUP 38 7.4 EUT OPERATION CONDITIONS 38 7.5 TEST RESULTS 39 8. PEAK OUTPUT POWER TEST 41 8.1 LIMIT 41 8.2 TEST PROCEDURE 41 8.3 TEST SETUP 41 8.4 EUT OPERATION CONDITIONS 41 8.5 TEST RESULTS 42 9. ANTENNA REQUIREMENT 43 9.1 STANDARD REQUIREMENT 43 9.2 EUT ANTENNA 43 10. EUT TEST PHOTO 44 Page 5 of 44 Report No.: STS2003192W06 Revision History Rev. Issue Date Report NO. Effect Page Contents 00 25 Mar. 2020 STS2003192W06 ALL Initial Issue Page 6 of 44 Report No.: STS2003192W06 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.247 (c) Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2013. Page 7 of 44 Report No.: STS2003192W06 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : A 1/F, Building B, Zhuoke Science Park, No.190 Chongqing Road, HepingShequ, Fuyong Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.68dB 2 Unwanted Emissions, conducted ±2.988dB 3 All emissions, radiated 30-1GHz ±6.7dB 4 All emissions, radiated 1G-6GHz ±5.5dB 5 All emissions, radiated>6G ±5.8dB 6 Conducted Emission (9KHz-150KHz) ±4.43dB 7 Conducted Emission (150KHz-30MHz) ±5dB Page 8 of 44 Report No.: STS2003192W06 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name GPS Tracker Trade Name N/A Model Name VST001 Series Model N/A Model Difference N/A Product Description The EUT is a GPS Tracker Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Radio Technology: BLE Bluetooth Version: 4.0 Bluetooth Configuration: LE Number Of Channel: 40 Antenna Designation: Please refer to the Note 3. Antenna Gain (dBi) 1.39 d…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2AAI6-VST001 DTS Setup photo Model name: VST001 DTS conduction DTS radiation L Page 2 of 2 FCC ID: 2AAI6-VST001 DTS radiation H

Contact Information

Applicant

Shlomo Shur(CTO)
[email protected]2035227553Fax: 7184250442

Technical Contact

Shenzhen STS Test Services Co., Ltd.Bovey Yang
[email protected]86-0755 36886288

A 1/F, Building B, Zhuoke Science Park, No.190 · Baoan District, Shenzhen, Guangdong · China

Test Firm

SHENZHEN STS TEST SERVICES CO.,LTD.Bovey Yang
[email protected]+86 755-36886288

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz143.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Trackimo INC.

GPS Tracker - FCC ID 2AAI6-TRKI005-C - Trackimo INC.
2AAI6-TRKI005-C

GPS Tracker

Mar 20, 2026

Equipment Class

DTS - Digital Transmission System
NickWatch V1 - FCC ID 2AAI6-NICKW001-2 - Trackimo INC.
2AAI6-NICKW001-2

NickWatch V1

Nov 08, 2023

Equipment Class

PCT - PCS Licensed Transmitter worn on body
GPS Tracker - FCC ID 2AAI6-TRKM110-T - Trackimo INC.
2AAI6-TRKM110-T

GPS Tracker

Dec 18, 2022

Equipment Class

PCB - PCS Licensed Transmitter
GPS Tracker - FCC ID 2AAI6TRKM010 - Trackimo INC.
2AAI6TRKM010

GPS Tracker

Sep 17, 2020

Equipment Class

PCB - PCS Licensed Transmitter
GPS Tracker - FCC ID 2AAI6TRKM110 - Trackimo INC.
2AAI6TRKM110

GPS Tracker

Aug 20, 2020

Equipment Class

PCB - PCS Licensed Transmitter