FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NEOLAB CONVERGENCE/
  3. 2AALG-NPR-R100

2AALG-NPR-R100NEO SMARTPEN

NEOLAB CONVERGENCE
NEO SMARTPEN - FCC ID 2AALG-NPR-R100 - NEOLAB CONVERGENCE
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 20, 2020
Application Purpose
Original Equipment
Date of Application
Apr 20, 2020
Equipment Note
NEO SMARTPEN
Frequency Range
2402.00000000 - 2480.00000000
Company
NEOLAB CONVERGENCE
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

NPR-R100 User Manual​NeoLAB Convergence Inc. User Manual NPR-R100 (Model Name: NPR-R100) Version : 0.1 Revision Date : 2020-03-31 1. Introduction NPR-R100 is a new accessory of Neo Smartpen that provides recording function for learning and work. You don't have to have a smartphone to record, and if you want to listen to the recorded voice at that time, you can immediately listen to it by tapping the handwritten part without additional action. That is, it is possible to save time to listen to the important part again. 2. Features ● New design ○ It has a simple design so that you can record naturally. ○ The button is placed in an easy-to-use position. ● Easy UX ○ Connection: NEO SMARTPEN and NPR-R100 are connected automatically. Just turn on and put them aside. ○ Record: Just press the record button to start recording immediately. ○ Playback: When you tap a handwritten part, the voice of the part is played. ● Main specifications ○ Up to 150 hours of recorded files can be saved. ○ Up to 10 hours of continuous recording is possible with a single charge. ○ The recording monitoring function allows you to listen to the sound quality currently being recorded. ○ Slim 1.7cm thick and light weight 35g NPR-R100 User Manual​NeoLAB Convergence Inc. 3. In the box ● NPR-R100 x1 ● Micro-USB Cable x1 ● Neck Strap x1 ● Paper Controller x1 ● User Manual x1 4. Exterior diagram 5. How to use ● Turn on & Start recording NPR-R100 User Manual​NeoLAB Convergence Inc. ● Play & Turn off 6. Indicators Status Power/BT LED REC/Play LED Power ON ●​​On Power OFF ●​-​●​-​●​,​ ​○ Off Connection with pen ●​​On Recording ●​-○-​●​-○​ ​Blinking Playing ●​-○-​●​-○​ ​Blinking Pause playback ●​On Low battery ●​-​●​-​●​-​●​ ​Blinking Charging ●​​On File transmission ●​-○-​●​-○​ ​Blinking Low storage / Time information error ●​-○-​●​-○​ ​Blinking Error occurred (reset required) ●​-​●​-​●​-​●​ ​Blinking●​-​●​-​●​-​●​ ​Blinking NPR-R100 User Manual​NeoLAB Convergence Inc. 7. Product Specification Model Name NPR-R100 Storage 16GB (eMMC) Ports Ear jack 3.5Φ x 1, Micro-USB 2.0 x 1 (Charging & Data) Speaker 1W x 1 Bluetooth Bluetooth 4.2, BLE mode support Frequency: 2,402~2,480 MHz Tx Power: ≤3mW(4.77dBm)/MHz Rx Sensitivity: -96.5dBm @ BLE Power Input Power: 5V, USB Micro B type Battery: Li-polymer 3.7V/ 560mAh(Operation range:3.5 ~ 4.2V) Operating time 10 hours of continuous use Dimensions, Weight 95.7mm x 27.1mm x 17.1mm, ≤ 35g Environment Specification Operating Temperature: 10°C ~ 35°C Storage Temperature (~3 Months): -10°C ~ 50°C 8. Precautions ● The NPR-R100's Bluetooth wireless connection works only with Neo Smartpen. Wireless connection and operation with other devices does not work. ● When recording continuously for 2 hours or more, to reduce the risk of loss of the recorded file, the recorded file is saved in two-hour increments (225,032 KB). ● Please do not add / modify / delete any files and folders arbitrarily in NPR-R100 via PC. It may be the main cause of product malfunction. ● The NPR-R100 can be recorded independently without a Neo Smartpen connection, but it is recommended to record while writing after connecting with a pen for convenient recorded file browsing. ● If there is no operation for 15 minutes after power ON, power is automatically turned off to save battery. ● When the storage space is over 80%, an LED display and a beep sound are played every 10 minutes. Please use it after emptying the storage space. ● When the battery is below 20%, an LED indicator and a beep sound are played every 10 minutes. If it is below 5%, recording will not work, so please use it after charging. 9. Warranty ● Please contact the store where you purchased the product or NeoLAB Convergence for customer service/support. -FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: · Reorient or relocate the receiving antenna. ·Increase the separation between the equipment and receiver. ·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. -Caution THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. -IMPORTANT NOTE : FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cover Letter(s)

Rev 11/20/07 #1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 Tel No : +82-2-2284-9241 Fax No : +82-2-3462-2983 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID : 2AALG-NPR-R100 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block diagram Schematics Schematics_PCB Layout Parts list Operational description Operational description_Antenna specification Block diagram(2AALG-NPR-R100).pdf Schematics(2AALG-NPR-R100).pdf Schematics_PCB Layout(2AALG-NPR-R100).pdf Part list(2AALG-NPR-R100).pdf Operational description(2AALG-NPR-R100).pdf Operational description_Antenna specification (2AALG- NPR-R100).pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Cho Min-Gu / Senior Research Engineer NEOLAB CONVERGENCE

Cover Letter(s)

FCC SDoC According to FCC Part 15 Applicant Name : NeoLAB Convergence Address : #1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 Telephone : +82-70-4377-074 Declares that Product : NPR-R100 Model Name : NPR-R100 Report Number : CTK-2020-01694 * Note #1. Test Standard(method) used: FCC Part 15 Subpart B This device complies with Part 15 of the FCC rules. Operations is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Test Laboratory: CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Designation Number : KR0025 Test Firm Registration Number : 805871 Tel : +82-31-339-9970 Fax : +82-31-624-9501 Responsible Party: Company Name : NeoLAB Convergence Company Address : #1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 Phone : Tel : +82-2-2284-9241 Fax : - Name : Cho Min-Gu Signature :

Cover Letter(s)

#1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 Tel No : +82-2-2284-9241 Fax No : +82-2-3462-2983 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: April 14, 2020 SUBJECT: FCC Application for (FCC ID : 2AALG-NPR-R100) To Whom It May Concern: We, the undersigned, hereby authorize Young-taek, Lee at CTK on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by CTK on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Cho Min-Gu/ Senior Research Engineer NEOLAB CONVERGENCE

External Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT External Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com

ID Label/Location Info

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Label Photographs 34 mm 13.6 mm

Internal Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT Internal Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com PCB CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Battery CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Antenna

RF Exposure Info

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 1 of 3 RF EXPOSURE EVALUATION 1.Client Information Company NeoLAB Convergence Contact Point #1501, Mario Tower, 28, Digital-ro 30-gil , Guro-gu, Seoul, Korea 08389 Contact Person Name : Cho Min-gu E-mail : [email protected] Tel : +82-2-2284-9241 Fax : +82-2-3462-2983 2.Product Information FCC ID 2AALG-NPR-R100 Product Description NEO SMARTPEN Model name NPR-R100 Variant Model name - Operating Frequency 2 402 MHz - 2 480 MHz RF Output Power 0.37 dBm (1.089 mW) Antenna Specification Antenna type : Chip Antenna Peak Gain : 3.4 dBi Number of channels 40 Channel Spacing 2 MHz Type of Modulation GFSK(BLE) Power Source DC 3.7 V RF Power setting in Test SW Initial value CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 2 of 3 ** RF Exposure Evaluation** Limits SAR Test Exclusion Thresholds for 100 MHz - 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table, The equation and threshold in Note 1 must be applied to determine SAR test exclusion. Note 1: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by : CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 3 of 3 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]* [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where - f(GHz) is the RF channel transmit frequency in GHz - Power and distance are rounded to the nearest mW and mm before calculation - The result is rounded to one decimal place for comparison - 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1f) is applied to determine SAR test exclusion. Output Power: Mode Frequency (MHz) Maximum output power to antenna (mW) SAR Test Exclusion Threshold (mW) BLE 2 480 1.089 10 Per FCC KDB 447498 D01v06, the SAR exclusion threshold for distances ≤50mm is defined by the following equation : [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]* [√f(GHz)] ≤ 3.0 Base on the maximum conducted power of the antenna to use separation distance, SAR was not required; BLE : [(1.089 / 5) * √2.480] = 0.34 (≤ 3.0) Result : As a result of the calculation above, the SAR test is exempt.

Test Report

TEST REPORT CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-01709 Page (1) / 30) Pages QF-QP15-03 R101 Rev.0 1. Client ◦ Name : NeoLAB Convergence ◦ Address : #1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 ◦ Date of Receipt : 2020-03-27 2. Manufacturer ◦ Name : NeoLAB Convergence ◦ Address : #1501, Mario Tower, 28, Digital-ro 30-gil, Guro-gu, Seoul, Korea 08389 3. Use of Report : For FCC Certification 4. Test Sample / Model : NEO SMARTPEN / NPR-R100 5. Date of Test : 2020-03-30 to 2020-04-13 6. Test Standard(method) used : FCC 47 CFR part 15 subpart C 15.247, ANSI C63.10-2013 7. Testing Environment : Temp.: (23 ± 1) °C, Humidity: (51 ± 3) % R.H. 8. Test Results : Compliance The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full. Affirmation Tested by Bong-seok Kim: (Signature) Technical Manager Young-taek Lee: (Signature) 2020-04-14 Republic of KOREA CTK Co., Ltd. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-01709 Page (2) / (30) Pages QF-QP15-03 R101 Rev.0 REPORT REVISION HISTORY Date Revision Page No 2020-04-14 Issued (CTK-2020-01709) all This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-01709 Page (3) / (30) Pages QF-QP15-03 R101 Rev.0 CONTENTS 1. General Product Description ........................................................................................ 4 1.1 Client Information .............................................................................................. 4 1.2 Product Information ............................................................................................ 4 1.3 Peripheral Devices .............................................................................................. 4 2. Facility and Accreditations ........................................................................................... 5 2.1 Test Facility........................................................................................................ 5 2.2 Laboratory Accreditations and Listings .................................................................. 5 2.3 Calibration Details of Equipment Used for Measurement .......................................... 5 3. Test Specifications ..................................................................................................... 6 3.1 Standards.......................................................................................................... 6 3.2 Mode of operation during the test ......................................................................... 6 3.3 Maximum Measurement Uncertainty ..................................................................... 7 4. Technical Characteristic Test ........................................................................................ 8 4.1 6dB Bandwidth & 99% Bandwidth......................................................................... 8 4.2 Maximum peak Conducted Output Power ............................................................. 11 4.3 Power Spectral Density ..................................................................................... 13 4.4 Band Edge & Conducted Spurious emission .......................................................... 15 4.5 Radiated Emission ............................................................................................ 18 4.6 AC Power Line Conducted Emissions ................................................................... 27 APPENDIX A – Test Equipment Used For Tests ................................................................. 30 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-01709 Page (4) / (30) Pages QF-QP15-03 R101 Rev.0 1. General Product Description 1.1 Client Information Company NeoLAB Convergence Contact Point #1501, Mario Tower, 28, Digital-ro 30-gil , Guro-gu, Seoul, Korea 08389 Contact Person Name : Cho Min-gu E-mail : [email protected] Tel : +82-2-2284-9241 Fax : +82-2-3462-2983 1.2 Product Information FCC ID 2AALG-NPR-R100 Product Description NEO SMARTPEN Model name NPR-R100 Variant Model name - Operating Frequency 2 402 MHz - 2 480 MHz RF Output Power 0.37 dBm (1.089 mW) Antenna Specification Antenna type : Chip Antenna Peak Gain : 3.4 dBi Number of channels 40 Channel Spacing 2 MHz Type of Modulation GFSK(BLE) Power Source DC 3.7 V RF Power setting in Test SW Initial value 1.3 Peripheral Devices -For Conducted Measurement and Radiated Measurement Device Manufacturer Model No. Serial No. Notebook SAMSUNG Electronics NT951SBE 1A8691AM500016R AC Adapter Chicony Power Technology W18-065N1A PD-65AWNKR CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-01709 Page (5) / (30) Pages QF-QP15-03 R101 Rev.0 2. Facility and Accreditations 2.1 Test Facility The measurement facility is located at (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yong-in-si, Gyeonggi-do, Korea. 2.2 Laboratory Accreditations and Listings Country Agency Registration Number USA FCC 805871 CANADA ISED 8737A-2 KOREA NRRA KR0025 2.3 Calibration Details of Equipment Used for Measurement Test equipment and test accessories are calibrated on regular basis. The maximum time between calibrations is one year or …

Text truncated - open the document above for the full version.

Test Setup Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Setup Photos and Configuration Radiated Electric Field Emissions 9 kHz to 30 MHz 30 MHz to 1 GHz CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com 1GHz to 18 GHz 18 GHz to 26.5 GHz CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Conducted Emissions Line Conducted

Contact Information

Applicant

Cho Min-Gu
[email protected]82-70-4377-0740Fax: 82-2-3462-2983

Test Firm

CTK Co., Ltd.Young-Joon Park
[email protected]82-31-339-9871Fax: 82-31-624-9501

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from NEOLAB CONVERGENCE

SMARTPEN - FCC ID 2AALG-NWP-F45 - NEOLAB CONVERGENCE
2AALG-NWP-F45

SMARTPEN

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
NWP-F151 - FCC ID 2AALG-NWP-F151 - NEOLAB CONVERGENCE
2AALG-NWP-F151

NWP-F151

Nov 26, 2022

Equipment Class

DTS - Digital Transmission System
Smart Pen - FCC ID 2AALG-NWP-F130 - NEOLAB CONVERGENCE
2AALG-NWP-F130

Smart Pen

Aug 10, 2021

Equipment Class

DTS - Digital Transmission System
2AALG-NWP-F80

Neo Smartpen

Apr 04, 2021

Equipment Class

DTS - Digital Transmission System
Neo smartpen N2 - FCC ID 2AALG-NWP-F110 - NEOLAB CONVERGENCE
2AALG-NWP-F110

Neo smartpen N2

Sep 18, 2014

Equipment Class

DTS - Digital Transmission System