2ADXK-3622ECG recorder

Shenzhen Viatom Technology Co., Ltd.
ECG recorder - FCC ID 2ADXK-3622 - Shenzhen Viatom Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 11, 2021
Application Purpose
Original Equipment
Date of Application
Apr 11, 2021
Equipment Note
ECG recorder
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Viatom Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I VersionDateDescriptionAuthor User'sManual(ECG recorder) ShenzhenViatomTechnology Co.,Ltd. DocumentNumberReversion 42-DO-00281A AuthorReviewApproval ©ViATOMTECHNOLOGY(UNPUBLISHED)ALLRIGHTS RESERVED ThismaterialistheproprietaryinformationofViATOMTechnology.And anyuse,reproduction,ordistributionofthematerialcontainedherein,unless specificallyauthorizedbyViATOMTechnology,isexpresslyforbiddenand wouldviolatetherightsandinterestsofViATOMTechnology. II ER2ECGrecorder Contents 1.Thebasics......................................................................................1 2.Introduction...................................................................................3 3.UsingInstructions............................................................................6 4.Maintenance..................................................................................9 5.Accessories....................................................................................11 6.Specifications...............................................................................11 7.Electromagneticcompatibility....................................................11 User’sManual 1 1. Thebasics Thismanualcontainstheinstructionsnecessarytooperatethe productsafelyandinaccordancewithitsfunctionandintended use.Observanceofthismanualisaprerequisiteforproper productperformanceandcorrectoperationandensurespatient andoperatorsafety. 1.1Safety WarningsandCautionaryAdvices  Beforeusingthisequipment,pleasereadthismanual carefullyandfullyunderstandthewarningsandrisks.  Thisdeviceisnotintendedtoreplacethemedical diagnosisofaprofessionaldoctor.  Themeasurementresultsofthisdeviceareforreference onlyandcannotbedirectlyusedasabasisforclinical treatment.  Wedonotrecommendtheuseofthisdeviceifyouhavea pacemakerorotherimplantabledeviceinyourbody.Please followthedoctor'sadviceifnecessary.  Thisdevicecannotbeusedwithadefibrillator. Thisdevicecannotbeusedduringctornuclearmagnetic resonance(MRI)procedures.  Thisequipmentmustnotbeusedinaflammable environment(egoxygen-richenvironment).  Thisdeviceisnotintendedforusebyinfantsweighing lessthan10kg.  Donotswimorsubmergethedeviceinthewater.Donot immersethedeviceinwaterorotherliquids.  Donotuseacetoneorothervolatilesolutionstocleanthe device.  Donotstronglycollideorcrushthedevice.Ifthecasingis 2 broken,stopusingit.  Thisdevicecannotbeplacedinapressurevesselorgas sterilizationequipment.  Donotdisassemblethedeviceatwill,otherwiseitmay causemachinemalfunctionoraffectthenormaloperation ofthedevice.  Keepthisdeviceoutofthereachofchildrenorpets 、 pests.  Thisdeviceshouldnotbeusedonpeoplewithsensitive skinorallergies.  Thisequipmentcannotbeplacedinthefollowing environments:directsunlight,hightemperature,high humidity,closetowaterorfiresources,andhigh electromagneticinfluence.  Usersshouldtrytoavoidsweating.Thesweatwillaffect thecontactbetweentheelectrodesandtheskin,affecting thequalityofthemeasurement.  Usersshouldinspectloosenedelectrodes,thatcandegrade performanceorcauseotherproblems  Donotparticipateinviolentorextensivephysicalactivity inordertomakeappropriatemeasurements.  Themeasurementresultsofthisdevicecannotdistinguish alldiseases.Ifyourbodyfeelsunwell,youshouldconsult yourdoctorimmediately,inadditiontothemeasurement resultsofthisdevice.  Donotself-diagnoseandtakemedicationbasedonthe measurementsofthisdevicewithoutconsultingyour doctor.Inparticular,donottakenewmedicationswithout priorpermission.  Thisdeviceisnotasubstituteforprofessionalheartor otherorganfunctionmeasurementequipment.Medical ECGmeasurementrequiresmoreprofessionaland completemeasurements.  Thisdevicecannotbeusedtodiagnoseadisease directly.Pleaseconsultyourdoctor. 3  WerecommendthatyourecordyourECGcurveandthe resultsofthemeasurementsandprovidethemtoyour doctorifnecessary.  Waste(includingtheequipmentitselfisscrapped)is disposedofinaccordancewithrelevantlawsand regulations.  Whentheambienttemperatureis20°C,theminimumand maximumstoragetemperaturefromtheproducttoready foruseis2H(thetimerequired).  Thepatientistheexpecteduser.  Donotpileupthelongtubingattheheadofthebed,asit maywraparoundtheheadorneckofthepatientduring sleep.  Libatteriescapacitywilldecreaseafterchargedischarge for300times.  Theelectrodes(Appliedparts)shouldnotcontactother conductivepartsincludingearth 2. Introduction 2.1IntendedUse Theproductisintendedtomeasure,reviewandstoreadults’ ECGdataathomeorinhealthcareenvironment,doesnotcontain auto-analysisfunction. 2.1.1Contraindications: Theproductisnotintendedforuseinpatientswithcardiac pacemakersorotherimplantabledevices. 4 2.2AboutER2 Figure1 1.ECGelectrode Itisusedtoconnectthebodysurfaceandreceivethe humanbodyECGsignal. 2.LEDindicator Off:Thedeviceisnotactivationorbatteryisrunout, Green:theleadisoff; Greenandflash(Accordingtopatientheartraterhythm): Thedeviceisworkingnormally; Greenandflash(5secondsapart):measurementcompleted andthedeviceisinnormalstandbymode,orwhenthe batteryisfullycharged; Yellow:thedeviceischarging,anditisoffafterbeing fullycharged; Yellowandflash(5secondsapart):thebatteryis low(Standbymode); Blue:ThedeviceisinBluetoothconnectionandthedevice 1 1 3 2 4 5 isinnormalstandbymode; Blueandflash(Accordingtopatientheartraterhythm):The deviceisworkingnormallyandThedeviceisin Bluetoothconnection. 3.Charginginterface Usedtoconnectthechargingcable. 4.Chargingbase Fortheproducttocharge. 2.3Symbols SymbolSignificance TypeCF-AppliedPart Manufacturer Authorizedrepresentativein theEuropeanCommunity ThisproductcomplieswiththeEuropea CouncilDirective 93/42/EEC(MedicalDeviceDirective) Caution,Incorrectusemaycause personalinjuryanddamagesofgoods. Refertoinstructionmanual. IP22 Protectedagainstsprayingwaterand againstaccesstohazardouspartswitha tool,perIEC60529. FollowInstructionsforUse. Non-ionizingradiation SNSerialnumber Indicateseparatecollectionforelectrical andelectronicequipment(WEEE). 0197 6 2.4Productstructureandcomposition ThisproductismainlycomposedofECGrecordermainunit, chargingbase,charg…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32N00009701Page 33 of 48 9PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:ER2 ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32N00009701Page 34 of 48 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32N00009701Page 35 of 48 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32N00009701Page 36 of 48 ViewofProduct-7 ViewofProduct-8

ID Label/Location Info

ER2-Label ECG Recorder Model:ER2 Internal Power:3.7V/90mAh Li-ion rechargeable Charging Base:DC4.5-5.5V,50mA FCC ID:2ADXK-3622 Shenzhen Viatom Technology Co.,Ltd. SN:1904420001 Production Date:2019.04 0197 Not intended for infants weighing less than 10kg.

Internal Photos

ReportNo.:EED32N00009701Page 36 of 48 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32N00009701Page 37 of 48 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32N00009701Page 38 of 48 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32N00009701Page 39 of 48 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32N00009701Page 40 of 48 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32N00009701Page 41 of 48 ViewofProduct-17 ViewofProduct-18 ReportNo.:EED32N00009701Page 42 of 48 ViewofProduct-19 ViewofProduct-20 ReportNo.:EED32N00009701Page 43 of 48 ViewofProduct-21 ViewofProduct-22 ReportNo.:EED32N00009701Page 44 of 48 ViewofProduct-23 ViewofProduct-24 ReportNo.:EED32N00009701Page 45 of 48 ViewofProduct-25 ViewofProduct-26 ReportNo.:EED32N00009701Page 46 of 48 ViewofProduct-27 ViewofProduct-28 ReportNo.:EED32N00009701Page 47 of 48 ViewofProduct-29 ViewofProduct-30 ReportNo.:EED32N00009701Page 48 of 48 ViewofProduct-31 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32N00009702Page1of8 COVERPAGE RFExposureEvaluationReport Product:ECGrecorder Trademark:N/A Model/Typereference:ER2 SerialNumber:N/A ReportNumber:EED32N00009702 FCCID:2ADXK-3622 DateofIssue:Mar.23,2021 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRF ExposureGuidancev06 Testresult:PASS Preparedfor: ShenzhenViatomTechnologyCo.,Ltd 4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: KenCaiAaronMa Approvedby:Date:Mar.23,2021 DavidWang CheckNo.::4538098638 ReportNo.:EED32N00009702Page2of8 1Version VersionNo.DateDescription 00Mar.23,2021Original ReportNo.:EED32N00009702Page3of8 2Contents Page COVERPAGE.........................................................................................................................................................................1 1VERSION..............................................................................................................................................................................2 2CONTENTS..........................................................................................................................................................................3 3GENERALINFORMATION...............................................................................................................................................4 3.1C LIENT I NFORMATION ....................................................................................................................................................4 3.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................4 3.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ........................................................................................4 3.4T EST L OCATION .............................................................................................................................................................5 3.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 3.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 3.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ..............................................................................................5 4SAREVALUATION.............................................................................................................................................................6 4.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ...............................................................................................................6 4.1.1StandardRequirement........................................................................................................................................6 4.1.2EUTRFExposure...............................................................................................................................................7 PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS............................................................................................8 ReportNo.:EED32N00009702Page4of8 3GeneralInformation 3.1ClientInformation Applicant:ShenzhenViatomTechnologyCo.,Ltd AddressofApplicant:4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Manufacturer:ShenzhenViatomTechnologyCo.,Ltd AddressofManufacturer:4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Factory:ShenzhenViatomTechnologyCo.,Ltd AddressofFactory:4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China 3.2GeneralDescriptionofEUT ProductName: ECGrecorder ModelNo.(EUT): ER2 TradeMark: N/A EUTSupportsRadios application: 5.0(BLE) 3.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade: Default(manufacturerdeclare) TestSoftwareofEUT: nRFgoStudio AntennaType: integralantenna AntennaGain: 4.76dBi PowerSupply:DC3.7V MaxConductedPeak OutputPower: BT5.0:-4.01dBm TheMaxConductedPeakOutputPowerdatarefertothereport EED32N00009701 SampleReceivedDate: Jan.07,2021 SampletestedDate: Feb.25,2021toMar.10,2021 CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/were providedbytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32N00009702Page5of8 3.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 3.5DeviationfromStandards None. 3.6AbnormalitiesfromStandardConditions None. 3.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32N00009702Page6of8 4SAREvaluation 4.1RFExposureComplianceRequirement 4.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbody and10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThresholdcondition,listed below,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)]· [√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation 17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhent…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32N00009701Page 1 of 25 AppendixBluetoothLE ReportNo.:EED32N00009701Page 2 of 25 Contents AppendixA:DTSBandwidth ........................................................................................................ 3 TestResult ................................................................................................................................................ 3 TestGraphs .............................................................................................................................................. 4 AppendixB:OccupiedChannelBandwidth ................................................................................. 6 TestResult ................................................................................................................................................ 6 TestGraphs .............................................................................................................................................. 7 AppendixC:Maximumconductedoutputpower ....................................................................... 9 TestResult ................................................................................................................................................ 9 TestGraphs ............................................................................................................................................ 10 AppendixD:Maximumpowerspectraldensity ........................................................................ 12 TestResult .............................................................................................................................................. 12 TestGraphs ............................................................................................................................................ 13 AppendixE:Bandedgemeasurements ...................................................................................... 15 TestResult .............................................................................................................................................. 15 TestGraphs ............................................................................................................................................ 16 AppendixF:ConductedSpuriousEmission ................................................................................. 17 TestResult .............................................................................................................................................. 17 TestGraphs ............................................................................................................................................ 18 AppendixG:DutyCycle ............................................................................................................... 23 TestResult .............................................................................................................................................. 23 TestGraphs ............................................................................................................................................ 24 ReportNo.:EED32N00009701Page 3 of 25 AppendixA:DTSBandwidth TestResult Test Mode AntennaChannel DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6922401.6362402.3280.5PASS 24400.6962439.6362440.3320.5PASS 24800.6962479.6362480.3320.5PASS ReportNo.:EED32N00009701Page 4 of 25 TestGraphs BLE_1M_Ant1_2402 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.402 GHzSpan4 MHz400 kHz/ 3DB RBW 100 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -10.64 dBm 2.401636000 GHz 2 Marker 2 [T1 ] -4.46 dBm 2.401988000 GHz 3 Delta 3 [T1 ] -0.10 dB 692.000000000 kHz D1 -10.465 dBm Date: 25.FEB.2021 10:48:27 BLE_1M_Ant1_2440 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.44 GHzSpan4 MHz400 kHz/ 3DB RBW 100 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -11.08 dBm 2.439636000 GHz 2 Marker 2 [T1 ] -5.06 dBm 2.439984000 GHz 3 Delta 3 [T1 ] -0.08 dB 696.000000000 kHz D1 -11.062 dBm Date: 25.FEB.2021 12:01:43 ReportNo.:EED32N00009701Page 5 of 25 BLE_1M_Ant1_2480 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.48 GHzSpan4 MHz400 kHz/ 3DB RBW 100 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -10.65 dBm 2.479636000 GHz 2 Marker 2 [T1 ] -4.60 dBm 2.479988000 GHz 3 Delta 3 [T1 ] -0.09 dB 696.000000000 kHz D1 -10.605 dBm Date: 25.FEB.2021 13:11:39 ReportNo.:EED32N00009701Page 6 of 25 AppendixB:OccupiedChannelBandwidth TestResult Test Mode AntennaChannel OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.0720.0000.000---PASS 24401.0720.0000.000---PASS 24801.0720.0000.000---PASS ReportNo.:EED32N00009701Page 7 of 25 TestGraphs BLE_1M_Ant1_2402 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.402 GHzSpan4 MHz400 kHz/ 3DB RBW 30 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -6.99 dBm 2.401988000 GHz OBW 1.072000000 MHz T1 Temp 1 [T1 OBW] -24.50 dBm 2.401452000 GHz T2 Temp 2 [T1 OBW] -22.82 dBm 2.402524000 GHz Date: 25.FEB.2021 10:49:13 BLE_1M_Ant1_2440 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.44 GHzSpan4 MHz400 kHz/ 3DB RBW 30 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -7.53 dBm 2.439984000 GHz OBW 1.072000000 MHz T1 Temp 1 [T1 OBW] -25.21 dBm 2.439452000 GHz T2 Temp 2 [T1 OBW] -23.46 dBm 2.440524000 GHz Date: 25.FEB.2021 12:02:30 ReportNo.:EED32N00009701Page 8 of 25 BLE_1M_Ant1_2480 A Offset 0.5 dB LVL Att 40 dB * Ref 30 dBm Center2.48 GHzSpan4 MHz400 kHz/ 3DB RBW 30 kHz SWT 5 ms * VBW 300 kHz * 1 PK VIEW -70 -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 100 of 100 1 Marker 1 [T1 ] -7.19 dBm 2.479984000 GHz OBW 1.072000000 MHz T1 Temp 1 [T1 OBW] -24.39 dBm 2.479452000 GHz T2 Temp 2 [T1 OBW] -22.9…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32N00009701Page1of48 TESTREPORT Product:ECGrecorder Trademark:N/A Model/Typereference:ER2 SerialNumber:N/A ReportNumber:EED32N00009701 FCCID:2ADXK-3622 DateofIssue:Mar.23,2021 TestStandards :47CFRPart15SubpartC Testresult:PASS Preparedfor: ShenzhenViatomTechnologyCo.,Ltd 4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: KenCaiAaronMa Approvedby:Date:Mar.23,2021 DavidWang CheckNo.:4538098638 ReportNo.:EED32N00009701Page 2 of 48 1Content 1CONTENT.............................................................................................................................................................................2 2VERSION..............................................................................................................................................................................3 3TESTSUMMARY................................................................................................................................................................4 4GENERALINFORMATION...............................................................................................................................................5 4.1C LIENT I NFORMATION ....................................................................................................................................................5 4.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................5 4.3T EST C ONFIGURATION ...................................................................................................................................................7 4.4T EST E NVIRONMENT ......................................................................................................................................................7 4.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 4.6T EST L OCATION .............................................................................................................................................................8 4.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................8 5EQUIPMENTLIST..............................................................................................................................................................9 6TESTRESULTSANDMEASUREMENTDATA..........................................................................................................11 6.1A NTENNA R EQUIREMENT .............................................................................................................................................11 6.2C ONDUCTED E MISSIONS .............................................................................................................................................12 6.3M AXIMUM C ONDUCTED O UTPUT P OWER ...................................................................................................................15 6.4DTSB ANDWIDTH .........................................................................................................................................................16 6.5M AXIMUM P OWER S PECTRAL D ENSITY ......................................................................................................................17 6.6B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ....................................................................18 6.7R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................19 7APPENDIXA......................................................................................................................................................................30 8PHOTOGRAPHSOFTESTSETUP..............................................................................................................................31 9PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS......................................................................................33 ReportNo.:EED32N00009701Page 3 of 48 2Version VersionNo.DateDescription 00Mar.23,2021Original ReportNo.:EED32N00009701Page 4 of 48 3TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 PASS DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32N00009701Page 5 of 48 4GeneralInformation 4.1ClientInformation Applicant: ShenzhenViatomTechnologyCo.,Ltd AddressofApplicant: 4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Manufacturer: ShenzhenViatomTechnologyCo.,Ltd AddressofManufacturer: 4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China Factory: ShenzhenViatomTechnologyCo.,Ltd AddressofFactory: 4E,3#,TingweiIndustrialPark,HonglangNorth2nd Road,BaoanDistrict,Shenzhen,China 4.2GeneralDescriptionofEUT ProductName: ECGrecorder ModelNo.: ER2 AddModelNo.: N/A Trademark: N/A ProductType: MobilePortableFixLocation BluetoothVersion:V5.0 OperationFrequency: 2402MHz~24…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32N00009701Page 31 of 48 8PHOTOGRAPHSOFTESTSETUP TestmodelNo.:ER2 RadiatedspuriousemissionTestSetup-1(Below 30MHz) RadiatedspuriousemissionTestSetup-2 (Below1GHz) ReportNo.:EED32N00009701Page 32 of 48 RadiatedspuriousemissionTestSetup-3( Above1GHz) ConductedEmissionsTestSetup

Contact Information

Applicant

Bing Wang(Manager of R&D)
[email protected]+8675586721162Fax: +8675522649904

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power.

Other Applications from Shenzhen Viatom Technology Co., Ltd.

2ADXK-8624

Blood Pressure Monitor

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
Smart Wireless Station - FCC ID 2ADXK-1664 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-1664

Smart Wireless Station

Mar 26, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S10 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S10

Pulse Oximeter

Jan 24, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S13 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S13

Pulse Oximeter

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S11 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S11

Pulse Oximeter

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System