FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Viatom Technology Co., Ltd./
  3. 2ADXK-7600

2ADXK-7600Bluetooth Clinical Electrical Thermometer

Shenzhen Viatom Technology Co., Ltd.
Bluetooth Clinical Electrical Thermometer - FCC ID 2ADXK-7600 - Shenzhen Viatom Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 17, 2020
Application Purpose
Original Equipment
Date of Application
Aug 17, 2020
Equipment Note
Bluetooth Clinical Electrical Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Viatom Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User’sManual BluetoothClinicalElectrical Thermometer ModelDT1/DT2 2 1.TheBasics Thismanualcontainstheinstructionsnecessarytooper atetheproductsafelyandinaccordancewithitsfunctio nandintendeduse.Observanceofthismanualisapr erequisiteforproperproductperformanceandcorrecto perationandensurespatientandoperatorsafety.Profess ionals,non-professionals,andpatientscanoperatemedi caldeviceinaccordancewiththeinstructions. 1.1Safety  Getmedicalattentionifyouhavehighfeveror prolongedfever,especiallyyoungchildren.Read carefullyandfollowtheinstructionstoensureaccurate temperaturemeasurement.  Keepoutofreachofunsupervisedchildren. Componentsmaybeharmfulifswallowed.  Thisdeviceisdesignedfororal,rectal,oraxillaryuse only.  Pleasenotethattemperaturemeasuringareaffectedby manyfactors,includingstrongphysicalactivitybefore thetest,drinkinghotorcolddrinks,andmeasurement methods.  Avoidtakingtemperaturefor30minutesafterphysical exercise,bathing,dining,ordrinkinghotorcold beverages.  Stopusingthethermometerifitoperateserraticallyor ifthedisplaymalfunctions.  Allowthethermometertowarmnaturallytoroom temperaturebeforeusing.Performancemaybe affectedifoperatedorstoredoutsidestated temperatureandhumidityrangesorifthepatient's temperatureisbelowtheambient(room)temperature.  Pleasenotethattheuseofthisproductinhigh temperatureorhumiditymaycauseinaccurate temperaturemeasurementresults.  Donotboil,bite,bend,drop,ordisassemblethe 3 thermometer.  Donotsharethethermometerwithmorethanone personwithoutdisinfection,oritmaycause cross-infection.  Donottrytosterilizebyimmersingthethermometer headinalcoholorhotwater(watertemperature exceeds50°C).  Donotuseforcetosqueezetheproduct.Ifthe appearanceisdamaged,stopusingitimmediately.  Precisioncomponentsareusedintheconstructionof thisdevice.Extremesintemperature,humidity,direct sunlight,shockordustshouldbeavoided.  Cleanthedevicewithadry,softclothoracloth dampenedwithwaterandaneutraldetergent.Never usealcohol,benzene,thinnerorotherharshchemicals tocleanthedevice.  Measurementsmaybedistortedifthedeviceisused closetotelevision,microwaveoven,cellulartelephone, X-rayorotherdeviceswithstrongelectricalfields.  Usedequipment,partsandbatteryarenottreatedas ordinaryhouseholdwaste,andmustbedisposedof accordingtotheapplicablelocalregulations.  Pleasekeepthethermometerclosetotheskinwhen measuring.Ifitisloose,thetemperaturemeasurement resultcouldbeinaccurate.  Duringthemeasurement,pleaseavoidstrenuous activity,eatingorstrongemotionalupsanddowns,and usethisproductinarelativelystableindoor environment.  Whenreusingthedevice,confirmthatthedeviceis clean.  Donotmodifythedevice.Itmaycauseaccidentsor damagetothedevice.  Donotself-diagnosethemeasurementresultsandstart treatmentbyyourself.Alwaysconsultyourdoctorfor evaluationoftheresultsandtreatment. 4  Adultsarerequiredtoshavingtheskinbefore measuringtheirtemperature.Makesurethattheskin thatisincontactwiththethermometerisflatand wrinkle-free.  Donotusethedevicewhereflammablegasessuchas anestheticgasesarepresent.Itmaycausean explosion.  Pleasenotethattheuseofthisproductinhigh temperatureorhumiditymaycauseinaccurate temperaturemeasurementresults.  Theeffectivewirelesstransmissiondistanceofthis productinabarrier-freeenvironmentis10meters.If thedistanceexceedsthislimit,thisproductmaynot workproperly.Pleaseusethisproductintheeffective wirelesstransmissiondistance.  Thebatteryinsidethisproductcannotbereplaced.  Alltheillustrationsprovidedinthismanualarefor referenceonly.  Pleaserefertotheactualproduct.  Whenthedeviceisabnormalordamaged,pleasedo notusethedeviceagain,youcancontactthemanufacturer.  Ifnecessary,toobtaininformationontheuseand maintenanceoftheequipmentortoreportabnormal conditions,pleasecontactthemanufacturer. 5 2.Introduction 2.1IntendedUse Theproductisusedtomeasurebodytemperatureinthe homeandinthemedicalsector. 2.2Contraindications  ThosewhoareallergictostainlesssteelorPCplastic shouldnotusethisproduct. 2.3Symbols SymbolMeaning ApplicationparttypeBF Manufacturer CE0197 InconformitywithDirective93/42/EEC EuropeanRepresentative Symbolfor“ENVIRONMENTPROTECTION– Wasteelectricalproductsshouldnotbe disposedofwithhouseholdwaste.Please recyclewherefacilitiesexist.Checkwithyour localauthorityorretailerforrecyclingadvice”. IP22 Againstingressofsolidforeignobjects ≥12.5mmdiameter,Againstdripping(15°tilted) Followoperatinginstructions 6 2.4Abouttheproduct Productname:BluetoothClinicalElectricalThermometer Softwarereleaseversion:V1 Productmodel: ModelandConfigurationseethetablebelow. 1.On/Offbutton On/Off:longpressittoachievethisfunction. Whenyouwanttotakeyourtemperatureagain, shortly pressittore-measureyourtemperature. 2.Displayscreen Itvisuallydisplaysthetemperaturemeasurementresults. 3.Indicatorlight Greenlight:itmeansyourbodytemperatureisnormal. Yellow light:itmeansyouhaveamoderatefever. Redlight:itmeansyouhaveaultrahighfever. 4. Probetip No.Model Temperat ure measure ment function Bluetooth transmissio nfunction 1 DT1 √√ 2 DT2 √× 1 2 3 4 7 Itcanmeasurethetemperature. 2.5Screendisplayinformation Temperature display Unit/ Measurement 8 3.Usingthethermometer 3.1ChargetheBattery UsetheUSBcabletochargetheproduct.ConnecttheUSB cabletoaUSBchargerortothePC.Therewillbeabattery logoflashonthedevicewhencharging.Whenthebatteryis low,thedisplayscreenwilldisplayalowpowerprompt. Note:Thedevicecannotbeusedduringcharging.When charging,youmustuseaclassIIadapterconforming toIEC/EN60601-1,andtheoutputisDC5V1A.Ifit isnotfollowed,theremaybeariskofelectricshock. 3.2BeforeMeasurement 1.Pleaselongpresstheonkeytostarttheproduct. 2.Displayhistory Thehistoryrecordappearsonthescreen,indicatingthat thevalueisthelastmeasuredtemperature. 9 3.3Measurement Note: Beforemeasuringtemperature,pleasecleanthetemperature measuringheadwithorrubbingalcohol.Rinseitwithcoolwater. Thethermometersupportsmeasuringtemperatureofmultiplebody parts. Fortheinfantsunder3monthsold,itisrecommendedtomeasure rectaltemperature. Pleasefollowthebelowinstructions. Measuringoraltemperatu…

Text truncated - open the document above for the full version.

External Photos

Report No. : EED32M00172401Page 50 of 58 PHOTOGRAPHS OF EUT Constructional Details Test model No.: DT1 View of Product-1 View of Product-2 Report No. : EED32M00172401Page 51 of 58 View of Product-3 View of Product-4 Report No. : EED32M00172401Page 52 of 58 View of Product-5 View of Product-6 Report No. : EED32M00172401Page 53 of 58 View of Product-7 View of Product-8

ID Label/Location Info

DT1-Main Unit Below Cover-Marked 210-02362-01 LaoShiwei 2020.6.5 Xiao Qiang Jiang Xiaolong Wang Bing 2020.6.5 2020.6.5 2020.6.5 Bluetooth Clinical Electrical Thermometer Model:DT1 Power:3.7V Li-ion 90mAh Charge Specificaon:5V 1A Measuring Site:Mouth/Axilla/Rectum Manufactured by:Shenzhen Viatom Technology Co.,Ltd. SN:2006710001 www.viatomtech.com FCC ID:2ADXK-7600

Internal Photos

Report No. : EED32M00172401Page 54 of 58 View of Product-9 View of Product-10 Report No. : EED32M00172401Page 55 of 58 View of Product-11 View of Product-12 Report No. : EED32M00172401Page 56 of 58 View of Product-13 View of Product-14 Report No. : EED32M00172401Page 57 of 58 View of Product-15 View of Product-16 Report No. : EED32M00172401Page 58 of 58 View of Product-17 *** End of Report *** The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced except in full.

RF Exposure Info

ReportNo.:EED32M00172402Page1of8 1COVERPAGE RFExposureEvaluationReport Product:BluetoothClinicalElectricalThermometer Trademark:N/A Model/Typereference:DT1 SerialNumber:N/A ReportNumber:EED32M00172402 FCCID: 2ADXK-7600 DateofIssue:Aug.07,2020 TestStandards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D01GeneralRFExposureGuidancev06 Testresult:PASS Preparedfor: ShenzhenViatomTechnologyCo.,Ltd. 4E,Building3,TingweiIndustrialPark, No.6liufangRoad,Block67,Xin'anStreet, BaoanDistrict.Shenzhen,518101,Guangdong,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: SunlightSunJokYang Approvedby:Date:Aug.07,2020 SamChuang CheckNo.:3970354078 ReportNo.:EED32M00172402Page2of8 2Version VersionNo.DateDescription 00Aug.07,2020Original ReportNo.:EED32M00172402Page3of8 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION.............................................................................................................................................................................2 3CONTENTS.........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD .......................................................................................4 4.4T EST L OCATION ............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS .....................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS .........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER .............................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ..............................................................................................................6 5.1.1StandardRequirement......................................................................................................................................6 5.1.2Limits....................................................................................................................................................................6 5.1.3EUTRFExposure..............................................................................................................................................7 PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS..........................................................................................8 ReportNo.:EED32M00172402Page4of8 4GeneralInformation 4.1ClientInformation Applicant:ShenzhenViatomTechnologyCo.,Ltd. AddressofApplicant:4E,Building3,TingweiIndustrialPark,No.6LiufangRoad,Block67, Xin'anStreet,BaoanDistrict,Shenzhen,518101,Guangdong,China Manufacturer:ShenzhenViatomTechnologyCo.,Ltd. AddressofManufacturer:4E,Building3,TingweiIndustrialPark,No.6LiufangRoad,Block67, Xin'anStreet,BaoanDistrict,Shenzhen,518101,Guangdong,China Factory:ShenzhenViatomTechnologyCo.,Ltd. AddressofFactory:4E,Building3,TingweiIndustrialPark,No.6LiufangRoad,Block67, Xin'anStreet,BaoanDistrict,Shenzhen,518101,Guangdong,China 4.2GeneralDescriptionofEUT ProductName: BluetoothClinicalElectricalThermometer ModelNo.(EUT): DT1 TradeMark: N/A EUTSupportsRadios application: 5.0BTSinglemode,2402MHzto2480MHz 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHzto2480MHz ModulationType:GFSK TestPowerGrade: Default TestSoftwareofEUT: NrF AntennaType: ChipAntenna AntennaGain:0dBi PowerSupply:DC5V MaxConductedPeak OutputPower: -14.384dBm TheMaxConductedPeakOutputPowerdatarefertothereport EED32M00172401 SampleReceivedDate: Jun.15,2020 SampletestedDate: Jun.15,2020toJul.17,2020 Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ReportNo.:EED32M00172402Page5of8 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32M00172402Page6of8 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthecorrespondingSARExclusionThresholdcondition,listed below,issatisfied. 5.1.2Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdi…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32M00172401Page1of58 1 COVERPAGE TESTREPORT Product:BluetoothClinicalElectrical Thermometer Trademark:N/A Model/Typereference:DT1 SerialNumber:N/A ReportNumber:EED32M00172401 FCCID: 2ADXK-7600 DateofIssue:Aug.07,2020 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: ShenzhenViatomTechnologyCo.,Ltd. 4E,Building3,TingweiIndustrialPark, No.6LiufangRoad,Block67,Xin'anStreet, BaoanDistrict,Shenzhen,518101,Guangdong,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: SunlightSunJokYang Approvedby:Date:Aug.07,2020 SamChuang CheckNo.:3970354078 ReportNo.:EED32M00172401Page 2 of 58 2Version VersionNo.DateDescription 00Aug.07,2020Original ReportNo.:EED32M00172401Page 3 of 58 3TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) ANSIC63.10-2013PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 ANSIC63.10-2013PASS ConductedPeakOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) ANSIC63.10-2013PASS 6dBOccupiedBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) ANSIC63.10-2013PASS PowerSpectralDensity 47CFRPart15SubpartCSection 15.247(e) ANSIC63.10-2013PASS Band-edgeforRF ConductedEmissions 47CFRPart15SubpartCSection 15.247(d) ANSIC63.10-2013PASS RFConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) ANSIC63.10-2013PASS RadiatedSpurious Emissions 47CFRPart15SubpartCSection 15.205/15.209 ANSIC63.10-2013PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15SubpartCSection 15.205/15.209 ANSIC63.10-2013PASS Remark: TestaccordingtoANSIC63.4-2014&ANSIC63.10-2013. Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ReportNo.:EED32M00172401Page 4 of 58 4Content 1COVERPAGE.....................................................................................................................................................................1 2VERSION..............................................................................................................................................................................2 3TESTSUMMARY................................................................................................................................................................3 4CONTENT.............................................................................................................................................................................4 5TESTREQUIREMENT.......................................................................................................................................................5 5.1T ESTSETUP ...................................................................................................................................................................5 5.1.1ForConductedtestsetup...................................................................................................................................5 5.1.2ForRadiatedEmissionstestsetup...................................................................................................................5 5.1.3ForConductedEmissionstestsetup...............................................................................................................6 5.2T EST E NVIRONMENT ......................................................................................................................................................6 5.3T EST C ONDITION ............................................................................................................................................................6 6GENERALINFORMATION...............................................................................................................................................7 6.1C LIENT I NFORMATION ....................................................................................................................................................7 6.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................7 6.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ........................................................................................7 6.4D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................8 6.5T EST L OCATION .............................................................................................................................................................8 6.6D EVIATIONFROM S TANDARDS ......................................................................................................................................8 6.7A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................8 6.8O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ..............................................................................................8 6.9M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................9 7EQUIPMENTLIST............................................................................................................................................................10 8RADIOTECHNICALREQUIREMENTSSPECIFICATION........................................................................................13 AppendixA):6dBOccupiedBandwidth...................................................................................................................15 AppendixB):ConductedPeakOutputPower.......................................................................................................19 AppendixC):Band-edgeforRFConductedEmissions...............................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32M00172401Page 47 of 58 PHOTOGRAPHSOFTESTSETUP TestmodelNo.:DT1 RadiatedspuriousemissionTestSetup-1(Below30MHz) RadiatedspuriousemissionTestSetup-2(Below1GHz) ReportNo.:EED32M00172401Page 48 of 58 RadiatedspuriousemissionTestSetup-3(Above1GHz) RadiatedspuriousemissionTestSetup Thereareabsorbingmaterialsundertheground. ReportNo.:EED32M00172401Page 49 of 58 ConductedEmissionsTestSetup

Contact Information

Applicant

Bing Wang(Manager of R&D)
[email protected]+8675586721162Fax: +8675522649904

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz40.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Shenzhen Viatom Technology Co., Ltd.

2ADXK-8624

Blood Pressure Monitor

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
Smart Wireless Station - FCC ID 2ADXK-1664 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-1664

Smart Wireless Station

Mar 26, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S10 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S10

Pulse Oximeter

Jan 24, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S13 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S13

Pulse Oximeter

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System
Pulse Oximeter - FCC ID 2ADXK-S11 - Shenzhen Viatom Technology Co., Ltd.
2ADXK-S11

Pulse Oximeter

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System