FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Adam Hall GmbH/
  3. 2AFF6-2HLC

2AFF6-2HLCStage luminaire

Adam Hall GmbH
Stage luminaire - FCC ID 2AFF6-2HLC - Adam Hall GmbH
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 02, 2022
Application Purpose
Original Equipment
Date of Application
Dec 02, 2022
Equipment Note
Stage luminaire
Frequency Range
2402.00000000 - 2479.00000000
Company
Adam Hall GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER ́S MANUAL BEDIENUNGSANLEITUNG MANUEL D ́UTILISATION MANUAL DE USUARIO INSTRUKCJA OBSŁUGI MANUALE D ́USO H2 FC PENDANT LIGHT RGBAL WITH W-DMX™ CLH2FC(WH) CONTENTS / INHALTSVERZEICHNIS / CONTENU / CONTENIDO / TREŚĆ / CONTENUTO ENGLISH SAFETY INFORMATION 3 INTRODUCTION 5 CONNECTIONS, OPERATING AND DISPLAY ELEMENTS 5 OPERATION 6 DIFFUSERS 13 SUSPENDED INSTALLATION 15 CABLING THE CONNECTION TERMINAL 16 OPTIONAL ACCESSORIES 17 DMX TECHNOLOGY 18 TECHNICAL DATA 19 MANUFACTURER ́S DECLARATIONS 20 DEUTSCH SICHERHEITSHINWEISE 21 EINFÜHRUNG 23 ANSCHLÜSSE, BEDIEN- UND ANZEIGEELEMENTE 23 BEDIENUNG 24 STREUSCHEIBEN 31 HÄNGENDE INSTALLATION 33 ANSCHLUSSTERMINAL VERKABELN 34 OPTIONALES ZUBEHÖR 35 DMX TECHNIK 36 TECHNISCHE DATEN 37 HERSTELLERERKLÄRUNGEN 38 FRANCAIS MESURES PRÉVENTIVES 39 INTRODUCTION 41 RACCORDEMENTS, ÉLÉMENTS DE COMMANDE ET D’AFFICHAGE 41 MODE D’EMPLOI 42 DIFFUSEURS 50 INSTALLATION SUSPENDUE 52 CÂBLAGE DE LA BORNE DE RACCORDEMENT 53 ACCESSOIRES DISPONIBLES EN OPTION 54 TECHNIQUE DMX 55 CARACTÉRISTIQUES TECHNIQUES 56 DECLARATIONS 57 ESPAÑOL MEDIDAS DE SEGURIDAD 58 INTRODUCCIÓN 60 CONEXIONES, ELEMENTOS DE MANEJO Y ELEMENTOS DE VISUALIZACIÓN 60 MANEJO 61 DIFUSORES 68 INSTALACIÓN EN SUSPENSIÓN 70 CABLEADO DEL TERMINAL DE CONEXIONES 71 ACCESORIOS OPCIONALES 72 TECNOLOGÍA DMX 73 DATOS TÉCNICOS 74 DECLARACIÓN DEL FABRICANTE 75 POLSKI ŚRODKI OSTROŻNOŚCI 76 WPROWADZENIE 78 PRZYŁĄCZA, ELEMENTY OBSŁUGI I WSKAŹNIKI 78 OBSŁUGA 79 DYFUZORY 86 MONTAŻ WISZĄCY 88 OKABLOWANIE LISTWY PRZYŁĄCZENIOWEJ 89 AKCESORIA DODATKOWE 90 TECHNIKA DMX 91 DANE TECHNICZNE 92 DEKLARACJE PRODUCENTA 93 ITALIANO MISURE PRECAUZIONALI 94 INTRODUZIONE 96 CONNESSIONI, ELEMENTI DI COMANDO E DI VISUALIZZAZIONE 96 UTILIZZO 97 DIFFUSORI 104 INSTALLAZIONE A SOSPENSIONE 106 CABLAGGIO DEL TERMINALE DI COLLEGAMENTO 107 ACCESSORI OPZIONALI 108 TECNOLOGIA DMX 109 DATI TECNICI 110 DICHIARAZIONI DEL PRODUTTORE 111 DMX DMX CONTROL / DMX STEUERUNG / PILOTAGE DMX / CONTROL DMX / STEROWANIE DMX / CONTROLLO DMX 112 3 DMX DEUTSCH FRANCAIS ESPAÑOL ENGLISH ITALIANO POLSKI ENGLISH YOU HAVE MADE THE RIGHT CHOICE! This device was developed and produced under the highest standards of quality in order to ensure smooth operation for many years. Please read these operating instructions carefully so that you can use your new Cameo Light product quickly and optimally. You can find more information on Cameo Light on our website WWW.CAMEOLIGHT.COM. SAFETY INFORMATION 1. Please read through these instructions carefully. 2. Store all information and instructions in a secure location. 3. Follow the instructions. 4. Heed all warnings. Do not remove any safety warnings or other information from the device. 5. Use the device only in the intended manner. 6. Use only stable and suitable stands and/or mounts (for fixed installations). Make sure that wall mounts are properly installed and secured. Make sure that the device is securely installed and will not fall. 7. During installation, heed all safety provisions that apply in your country. 8. Do not install and operate the device in the vicinity of heaters, heat reservoirs, ovens, or other heat sources. Make sure that the device is installed in such a way that it is sufficiently cooled and will not overheat. 9. Do not place any ignition sources, e.g. candles, on the device. 10. Do not block the ventilation slits. 11. The device was designed to be used only in interior spaces, do not operate the device in the direct vicinity of water (this does not apply to specialty outdoor devices - in this case, please note the special instructions given in the following). Do not bring the device into contact with combustible materials, fluids, or gases. 12. Make sure that no water can drop or splash into the device. Do not place any containers filled with fluids, such as vases or drinking vessels, onto the device. 13. Ensure that no objects can fall into the device. 14. Operative the device using only those accessories recommended and specified by the manufacturer. 15. Do not open the device, and do not modify it. 16. After connecting the device, inspect all cable paths in order to avoid damage or accidents, such as those caused by tripping over said cables. 17. During transport, ensure that the device will not fall and potentially cause material damage and personal harm. 18. If your device no longer functions properly, fluids or objects have made their way into the device interior, or the device is otherwise damaged, switch it off immediately and remove it from the power outlet (provided the device is active). This device is to be repaired only by authorized specialists. 19. Use a dry towel to clean the device. 20. Follow all laws on disposal applicable in your country. Please separate plastic and paper or cardboard when disposing of the packaging. 21. Plastic bags must be kept out of reach of children. FOR DEVICES CONNECTED TO A POWER SUPPLY: 22. ATTENTION: If the device power cable is equipped with a ground pin, it must be inserted into an outlet with a grounding conductor. Never disable the grounding conductor of a power cable. 23. Do not immediately switch on the device when it has been exposed to stark temperature deviations (for example after transport). Humidity and condensation could damage the device. Switch on the device only when it has reached room temperature. 24. Before you connect the device to the outlet, first ensure that voltage and frequency of the power supply complies with the values given on the device. If the device has a voltage selector switch, connect the device to the outlet only if the device values comply with the values of the power supply. If the provided power cable or power adapter does not fit your power outlet, contact an electrician. 25. Do not step on the power cable. Make sure that live cables, in particular those at the power socket or at the power adapter and the device socket, are not bent. 26. With regard to the device cables, always make sure that the power cable or power adapter is a…

Text truncated - open the document above for the full version.

External Photos

Page 1 of 4 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Antenna

ID Label/Location Info

Page 1 of 1 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L3.5cm x 3.0cm) Label Location Stage luminaire Model: CLH2FC FCC ID: 2AFF6-2HLC

Internal Photos

Page 1 of 5 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10

RF Exposure Info

Page 1 of 3 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID 2AFF6-2HLC Product name Stage luminaire Test Model CLH2FC Additional Model No. CLH2FCWH, CLH2T, CLH2TWH, CLH2D, CLH2DWH Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power supply Input: AC 100-240V, 50/60Hz, 195W Modulation Type GFSK Antenna Type External Antenna Antenna Gain 2.16dBi(Max.) Hardware version / Software version / FCC Operation frequency 2402MHz ~ 2479MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. Page 2 of 3 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information Internal Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna Internal Antenna 2402MHz ~ 2479MHz 2.16dBi 2.4G Antenna Page 3 of 3 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 6. Conducted Power < 2.4G Max Conducted Power > Mode Channel Frequency(MHz) Max Conducted Power (dBm) GFSK 0 2402 19.57 41 2442 19.13 78 2479 19.62 7. Manufacturing Tolerance < 2.4G > GFSK (Peak) Channel Channel 0 Channel 41 Channel 78 Target (dBm) 19.0 19.0 19.0 Tolerance ±(dB) 1.0 1.0 1.0 8. Measurement Results As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained. < 2.4G > Band/Mode RF output power Antenna Gain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBm mW GFSK 20.0 100.0000 2.16 0.0327 1.0000 Remark: 1. Output power including tune-up tolerance; 2. MPE evaluate distance is 20cm from user manual provide by manufacturer; 9. Conclusion The measurem…

Text truncated - open the document above for the full version.

Test Report

3# Antenna Study Project Name:3# Debugging frequency band: 2400-2500MHz Valuation date:2022.11.2108 Client Name:立讯检测 1 Internal Antenna 2 Testing 3D microwave darkroom(6m*6m*6m) Testing environment External Antenna 3 Antenna •Antenna name: 2.4G •Antenna Type:PIFA •Covers :2400-2500MHz 4 S Parameter_Return Loss&VSWR 5 Efficiency and Gain-Smith Frequency ID 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) 2400.0 2410.0 2420.0 2430.0 2440.0 2450.0 2460.0 2470.0 2480.0 2490.0 2500.0 Gain (dBi) 0.91 1.18 0.80 0.74 0.85 1.36 1.99 2.16 1.74 1.61 1.47 Efficiency (%) 31.20 32.60 32.74 35.08 37.03 38.93 43.16 44.60 43.12 44.12 44.76 Freespace Environment Performance – WIFI 6

Test Report

Page 1 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 2.4G (Conducted Measurement) Product Name: Stage luminaire Test Model: CLH2FC Environmental Conditions Temperature: 23.5  C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Li Huan Page 2 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 20dB Bandwidth Condition Mode Frequency (MHz) Antenna 20 dB Bandwidth (MHz) Limit 20 dB Bandwidth (MHz) Verdict NVNT GFSK 2402 Ant1 0.85 N/A Pass NVNT GFSK 2442 Ant1 0.821 N/A Pass NVNT GFSK 2479 Ant1 0.966 N/A Pass Page 3 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 20dB Bandwidth NVNT GFSK 2402MHz Ant1 20dB Bandwidth NVNT GFSK 2442MHz Ant1 Page 4 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 20dB Bandwidth NVNT GFSK 2479MHz Ant1 Page 5 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT GFSK 2402 Ant1 19.57 21 Pass NVNT GFSK 2442 Ant1 19.13 21 Pass NVNT GFSK 2479 Ant1 19.62 21 Pass Page 6 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT GFSK 2402MHz Ant1 Power NVNT GFSK 2442MHz Ant1 Page 7 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT GFSK 2479MHz Ant1 Page 8 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Carrier Frequencies Separation Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT GFSK Ant1 2401.974 2402.964 0.99 0.567 Pass NVNT GFSK Ant1 2442.014 2442.956 0.942 0.547 Pass NVNT GFSK Ant1 2477.956 2478.944 0.988 0.644 Pass Page 9 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs CFS NVNT GFSK 2402MHz Ant1 CFS NVNT GFSK 2442MHz Ant1 Page 10 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity CFS NVNT GFSK 2479MHz Ant1 Page 11 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Dwell Time Condition Mode Frequency (MHz) Antenna Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT GFSK 2402 Ant1 0.352 176.352 501 31600 400 Pass NVNT GFSK 2442 Ant1 0.352 176.352 501 31600 400 Pass NVNT GFSK 2479 Ant1 0.353 176.853 501 31600 400 Pass Page 12 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Dwell NVNT GFSK 2402MHz Ant1 One Burst Dwell NVNT GFSK 2402MHz Ant1 Accumulated Page 13 of 29 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 35 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR Adam Hall GmbH Stage luminaire Test Model: CLH2FC Additional Model No.: Please Refer to Page 6 Prepared for : Adam Hall GmbH Address : Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : August 03, 2022 Number of tested samples : 2 Sample No. : A080322051-1, A080322051-2 Serial number : Prototype Date of Test : August 03, 2022 ~ October 11, 2022 Date of Report : October 12, 2022 Page 2 of 35 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCSA080322051EA Date of Issue ................................... : October 12, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Adam Hall GmbH Address ........................................... : Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Test Specification Standard.......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Stage luminaire Trade Mark ...................................... : Cameo Test Model ...................................... : CLH2FC Ratings ............................................ : Input: AC 100-240V, 50/60Hz, 195W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Kay Hu/ Administrator Cary Luo/ Technique principal Gavin Liang / Manager Page 3 of 35 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA080322051EA October 12, 2022 Date of issue Test Model.............................. : CLH2FC EUT......................................... : Stage luminaire Applicant............................... : Adam Hall GmbH Address................................... : Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Telephone............................... : / Fax.......................................... : / Manufacturer......................... : CKC Lighting Co., Ltd(Lite Angle Limited) Address................................... : Guan Keng Gongye Yuan, Building#A, 2nd Floor, Dashi, P anyu, Guangzhou 510300, China Telephone............................... : / Fax.......................................... : / Factory................................... : CKC Lighting Co., Ltd(Lite Angle Limited) Address................................... : Guan Keng Gongye Yuan, Building#A, 2nd Floor, Dashi, P anyu, Guangzhou 510300, China Telephone............................... : / Fax.......................................... : / Page 4 of 35 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 October 12, 2022 Initial Issue --- Page 5 of 35 FCC ID: 2AFF6-2HLC Report No.: LCSA080322051EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................... 6 1…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2 Page 2 of 2 FCC ID: 2AFF6-2HLC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photo(s) of Conducted Emissions Measurement Fig. 3

Contact Information

Applicant

Michael Roesch
[email protected]+49 6081 9419753Fax: +49 6081 9419 1753

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz91.60 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Adam Hall GmbH

CARDIOID COLUMN PA SYSTEM - FCC ID 2AFF6-3G44IUAM - Adam Hall GmbH
2AFF6-3G44IUAM

CARDIOID COLUMN PA SYSTEM

Aug 21, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SPEAKER BOX - FCC ID 2AFF6-21YNNADL - Adam Hall GmbH
2AFF6-21YNNADL

SPEAKER BOX

Jan 08, 2026

Equipment Class

DTS - Digital Transmission System
Mixing Amplifier - FCC ID 2AFF6-021AMIDL - Adam Hall GmbH
2AFF6-021AMIDL

Mixing Amplifier

Aug 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Stage luminaire - FCC ID 2AFF6-SUPOLC - Adam Hall GmbH
2AFF6-SUPOLC

Stage luminaire

Feb 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HID Stage Luminaire - FCC ID 2AFF6-SOTOLC - Adam Hall GmbH
2AFF6-SOTOLC

HID Stage Luminaire

Feb 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter