FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Adam Hall GmbH/
  3. 2AFF6009PIUAM

2AFF6009PIUAMActive PA Box

Adam Hall GmbH
Active PA Box - FCC ID 2AFF6009PIUAM - Adam Hall GmbH
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 08, 2020
Application Purpose
Original Equipment
Date of Application
Jan 08, 2020
Equipment Note
Active PA Box
Frequency Range
2402.00000000 - 2480.00000000
Company
Adam Hall GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER ́S MANUAL BEDIENUNGSANLEITUNG MANUEL D`UTILISATION MANUAL DE USUARIO INSTRUKCJA OBSŁUGI MANUALE D‘ USO 操作说明书 操作說明書 MAUI ® P900 POWERED COLUMN PA SYSTEM BY PORSCHE DESIGN STUDIO GRAPHITE BLACK PLATINUM GREY COCOON WHITE LDMAUIP900B LDMAUIP900G LDMAUIP900W 操作說明書 CONTENTS / INHALTSVERZEICHNIS / CONTENU / CONTENIDO / TREŚĆ / CONTENUTO / 目录 / 目錄 ENGLISH PREVENTIVE MEASURES 3-4 INTRODUCTION 5 ASSEMBLY 5 CONNECTION AND OPERATION 5 CONNECTIONS, OPERATING AND DISPLAY ELEMENTS 6-8 WIRING EXAMPLES 9 OPTIONAL ACCESSORIES 10 TECHNICAL DATA 10-12 MANUFACTURER’S DECLARATIONS 12 DEUTSCH SICHERHEITSHINWEISE 13-14 EINFÜHRUNG 14-15 AUFBAU 15 ANSCHLUSS UND BETRIEB 15 ANSCHLÜSSE, BEDIEN- UND ANZEIGEELEMENTE 16-18 VERKABELUNGSBEISPIELE 19 OPTIONALES ZUBEHÖR 20 TECHNISCHE DATEN 20-22 HERSTELLERERKLÄRUNGEN 22 FRANCAIS MESURES PRÉVENTIVES 23-24 INTRODUCTION 24 STRUCTURE 25 RACCORDEMENT ET FONCTIONNEMENT 25 RACCORDEMENTS, ÉLÉMENTS DE COMMANDE ET D’AFFICHAGE 26-28 EXEMPLES DE CÂBLAGE 29 ACCESSOIRE DISPONIBLE EN OPTION 30 CARACTÉRISTIQUES TECHNIQUES 30-32 DÉCLARATIONS DU FABRICANT 32 ESPAÑOL MEDIDAS DE SEGURIDAD 3-34 INTRODUCCIÓN 34 MONTAJE 35 CONEXIÓN Y FUNCIONAMIENTO 35 CONEXIONES, ELEMENTOS DE MANEJO Y ELEMENTOS DE VISUALIZACIÓN 36-38 EJEMPLOS DE CABLEADO 39 ACCESORIOS OPCIONALES 40 DA TOS TÉCNICOS 40-42 DECLARACIONES DEL FABRICANTE 42 POLSKI ŚRODKI OSTROŻNOŚCI 43-44 WPROWADZENIE 44 MONTAŻ 45 GNIAZDA I DZIAŁANIE 45 PRZYŁĄCZA, ELEMENTY OBSŁUGI I WSKAŹNIKI 46-48 PRZYKŁADY OKABLOWANIA 49 AKCESORIA OPCJONALNE 50 DANE TECHNICZNE 50-52 OŚWIADCZENIA PRODUCENTA 53 ITALIANO MISURE PRECAUZIONALI 54-55 INTRODUZIONE 55 MONTAGGIO 56 CONNESSIONE E ACCENSIONE 56 CONNESSIONI, ELEMENTI DI COMANDO E VISUALIZZAZIONE 57-59 ESEMPI DI CABLAGGIO 60 ACCESSORI OPZIONALI 61 DATI TECNICI 61-63 DICHIARAZIONI DEL PRODUTTORE 63 简体中文 安全提示 64-65 引言 65 安装 66 连接与运行 66 接口、操作和显示元件 67-69 接线示例 70 可选配件 71 技术参数 71-73 制造商声明 73 繁體中文 安全注意事項 74-75 簡介 75 安裝 76 連接和操作 76 連接器、操縱及顯示元件 77-79 安裝說明 80 可選配件 81 技術數據 81-83 製造商聲明 83 3 DEUTSCH ENGLISH FRANCAIS ESPAÑOL POLSKI ITALIANO 简体中文 繁體中文 ENGLISH YOU‘VE MADE THE RIGHT CHOICE! We have designed this product to operate reliably over many years. LD Systems stands for this with its name and many years of experience as a manufacturer of high-quality audio products. Please read this User‘s Manual carefully, so that you can begin making optimum use of your LD Systems product quickly. You can find more information about LD-SYSTEMS at our Internet site WWW.LD-SYSTEMS.COM PREVENTIVE MEASURES 1. Please read these instructions carefully. 2. Keep all information and instructions in a safe place. 3. Follow the instructions. 4. Observe all safety warnings. Never remove safety warnings or other information from the equipment. 5. Use the equipment only in the intended manner and for the intended purpose. 6. Use only sufficiently stable and compatible stands and/or mounts (for fixed installations). Make certain that wall mounts are properly installed and secured. Make certain that the equipment is installed securely and cannot fall down. 7. During installation, observe the applicable safety regulations for your country. 8. Never install and operate the equipment near radiators, heat registers, ovens or other sources of heat. Make certain that the equipment is always installed so that is cooled sufficiently and cannot overheat. 9. Never place sources of ignition, e.g., burning candles, on the equipment. 10. Ventilation slits must not be blocked. 11. Keep a minimum distance of 20 cm around and above the device. 12. Do not use this equipment in the immediate vicinity of water (does not apply to special outdoor equipment - in this case, observe the special instructions noted below. Do not expose this equipment to flammable materials, fluids or gases. Avoid direct sunlight! 13. Make certain that dripping or splashed water cannot enter the equipment. Do not place containers filled with liquids, such as vases or drinking vessels, on the equipment. 14. Make certain that objects cannot fall into the device. 15. Use this equipment only with the accessories recommended and intended by the manufacturer. 16. Do not open or modify this equipment. 17. After connecting the equipment, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards. 18. During transport, make certain that the equipment cannot fall down and possibly cause property damage and personal injuries. 19. If your equipment is no longer functioning properly, if fluids or objects have gotten inside the equipment or if it has been damaged in another way, switch it off immediately and unplug it from the mains outlet (if it is a powered device). This equipment may only be repaired by authorized, qualified personnel. 20. Clean the equipment using a dry cloth. 21. Comply with all applicable disposal laws in your country. During disposal of packaging, please separate plastic and paper/cardboard. 22. Plastic bags must be kept out of reach of children. 23. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user ́s authority to operate the equipment. FOR EQUIPMENT THAT CONNECTS TO THE POWER MAINS 24. CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never deactivate the protective ground of a power cord. 25. If the equipment has been exposed to strong fluctuations in temperature (for example, after transport), do not switch it on immediately. Moisture and condensation could damage the equipment. Do not switch on the equipment until it has reached room temperature. 26. Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or pow…

Text truncated - open the document above for the full version.

Cover Letter(s)

Adam Hall GmbH Adam-Hall-Str.1 61267 Neu Anspach Germany TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: 2AFF6 009PIUAM To whom it may concern: Date: 2019/11/25 We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) Where our agent signs the application fo「cert巾cationon our behalf, I acknowledge that all responsib由ty for complying with the terms and conditions fo「Cert巾cation,as specified by SGS North America, Inc., st仆l resides with Adam Hall GmbH. This authorization is valid until furthe「writtennotice from the applicant Name (Printed): Michael Roesch Adam Hall GmbH Telephone: +49(0)6081-9419753 Title:Quality Manager @ 岫 m 佃 ,, . m b H Ada m-H all­ Ada m Hal lG Str. 1 Phone: 06081 1 941 9 _0 6 1 267 Neu-A ·F ax: 0 6 0 81 nsp ach a 知 心 肛 om / 94 1 9 - 1 00 0

Cover Letter(s)

Adam Hall GmbH Adam - Hall - Str.1 61267 Neu Anspach To: SGS North America Inc 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Adam Hall GmbH Adam Hall Str.1 61267 Neu Anspach, Germany Regarding: Confidentiality Request regarding application for FCC ID 2AFF6 009PIUAM LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission's rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Desc 「 iptions The documents above contain proprietary information not 「 eleased to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely , ;;;;; 三/ tw a d a m h a ir Adam Hall GmbH Adam-Hall-Str. 1·61267 Neu-Anspach Phone: 06081 / 9419-0 ·Fax: 06081 /9419-1000 adamhall.com

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 7 Page 1 of 7 External Photos Applicant: Adam Hall GmbH Address of Applicant: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Equipment Under Test (EUT): Product Name: Active PA Box Model No.: MAUI ® P900 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 7 Page 2 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 7 Page 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 7 Page 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 5 of 7 Page 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 6 of 7 Page 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 7 of 7 Page 7 of 7 End

ID Label/Location Info

Label location

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 19 Page 1 of 19 Internal Photos Applicant: Adam Hall GmbH Address of Applicant: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Equipment Under Test (EUT): Product Name: Active PA Box Model No.: MAUI ® P900 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 19 Page 2 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 19 Page 3 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 19 Page 4 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 5 of 19 Page 5 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 6 of 19 Page 6 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 7 of 19 Page 7 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 8 of 19 Page 8 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 9 of 19 Page 9 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 10 of 19 Page 10 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 11 of 19 Page 11 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 12 of 19 Page 12 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 13 of 19 Page 13 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 14 of 19 Page 14 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 15 of 19 Page 15 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 16 of 19 Page 16 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 17 of 19 Page 17 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 18 of 19 Page 18 of 19 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 19 of 19 Page 19 of 19 End

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476402 Page: 1 of 7 Parlam Zhan E&E Section Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. 1 Cover Page RF MPE REPORT Application No.: SHEM1806004764CR Applicant: Adam Hall GmbH FCC ID: 2AFF6009PIUAM Equipment Under Test (EUT): NOTE: The following sample(s) was/were submitted and identified by the client as Product Name: Active PA Box Model No.(EUT): MAUI ® P900 Trade Mark: LD SYSTEMS Standards: FCC Rules 47 CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt: 2019-06-14 Date of Test: 2019-08-27 to 2019-08-29 Date of Issue: 2019-09-06 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476402 Page: 2 of 7 Revision Record Version Description Date Remark 00 Original 2019-09-06 / Authorized for issue by: Vincent Zhu / Project Engineer Parlam Zhan /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476402 Page: 3 of 7 2 Contents Page 1 COVER PAGE ................................................................................................................................................. 1 2 CONTENTS ..................................................................................................................................................... 3 3 GENERAL INFORMATION ......................................................................................................................... 4 3.1 CLIENT INFORMATION .................................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................. 4 3.2 TECHNICAL SPECIFICATIONS .......................................................................................................................... 4 3.3 TEST LOCATION ............................................................................................................................................. 5 3.4 TEST FACILITY ............................................................................................................................................... 5 4 TEST STANDARDS AND LIMITS ............................................................................................................... 6 4.1 FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS: ................................................................................. 6 5 MEASUREMENT AND CALCULATION ................................................................................................... 6 5.1 MAXIMUM TRANSMIT POWER ........................................................................................................................ 6 5.2 MPE CALCULATION ....................................................................................................................................... 7 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476402 Page: 4 of 7 3 General Information 3.1 Client Information Applicant: Adam Hall GmbH Address of Applicant: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Manufacturer: Adam Hall GmbH Address of Manufacturer: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Factory: Speaker Electronic (Jiashan) Co., Ltd Address of Factory: No. 8 Development Zone Road, Huimin Sub-district, Jiashan County, Zhejiang, 314112, P.R. China 3.1 General Description of E.U.T. Power supply: AC 100-120/200-240V,50/60Hz Test voltage: AC 120V/60Hz Cable: AC Cable 1.8m 3.2 Technical Specifications Antenna Gain 2 dBi Antenna Type Dipole Antenna Channel Spacing 1MHz Modulation Type GFSK, π/4DQPSK, 8DPSK Number of Channels 79 Operation Frequency 2402MHz to 2480MHz Spectrum Spread Technology Frequency Hopping Spread Spectrum(FHSS) SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476402 Page: 5 of 7 3.3 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch 588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China Tel: +86 21 6191 5666 Fax: +86 21 6191 5678 No tests were sub-contracted. 3.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • CNAS (No. CNAS L0599) CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of testing. • NVLAP (Certificate No. 201034-0) SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0. • FCC –Designation Number: CN5033 SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited testing laboratory. Designation Number: CN5033. Test Firm Registration Number: 479755. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. EMC Laboratory has been recognized by ISED as an accredited testing laboratory. IC Registration No.: 8617A-1. CAB Identifie…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476401 Page: 1 of 107 Parlam Zhan E&E Section Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. TEST REPORT Application No.: SHEM1806004764CR FCC ID: 2AFF6009PIUAM Applicant: Adam Hall GmbH Address of Applicant: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Manufacturer: Adam Hall GmbH Address of Manufacturer: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Factory: Speaker Electronic (Jiashan) Co., Ltd Address of Factory: No. 8 Development Zone Road, Huimin Sub-district, Jiashan County, Zhejiang, 314112, P.R. China Equipment Under Test (EUT): EUT Name: Active PA Box Model No.: MAUI ® P900 Trade mark: LD SYSTEMS Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2019-06-14 Date of Test: 2019-08-27 to 2019-08-29 Date of Issue: 2019-09-06 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476401 Page: 2 of 107 Revision Record Version Description Date Remark 00 Original 2019-09-06 / Authorized for issue by: Bill Wu / Project Engineer Parlam Zhan /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476401 Page: 3 of 107 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(c) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.6 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 7.8.8 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM180600476401 Page: 4 of 107 3 Contents Page 1 COVER PAGE.............................................................................................................................................. 1 2 TEST SUMMARY ......................................................................................................................................... 3 3 CONTENTS .................................................................................................................................................. 4 4 GENERAL INFORMATION ......................................................................................................................... 6 4.1 DETAILS OF E.U.T.................................................................................................................................. 6 4.2 DESCRIPTION OF SUPPORT UNITS ........................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ................................................................................................................ 6 4.4 TEST LOCATION ..................................................................................................................................... 7 4.5 TEST FACILITY ....................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ................................................................................................................ 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 7 5 EQUIPMENT LIST ....................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ................................................................................... 9 6.1 ANTENNA REQUIREMENT ........................................................................................................................ 9 6.1.1 Test Requirement: ...............................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 4 Page 1 of 4 Test Setup Photos-FCC Applicant: Adam Hall GmbH Address of Applicant: Adam-Hall-Str. 1, 61267 Neu-Anspach, Germany Equipment Under Test (EUT): Product Name: Active PA Box Model No.: MAUI ® P900 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 4 Page 2 of 4 1 Contents Page 1 CONTENTS............................................................................................................... 2 2 EQUIPMENT UNDER TEST PICTURES ............................................................ 3 2.1 Conducted Emission Test Setup ....................................................................... 3 2.2 Radiated Emission Test Setup .......................................................................... 3 2.3 RF Conducted Test Setup ................................................................................. 4 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 4 Page 3 of 4 2 EQUIPMENT UNDER TEST PICTURES 2.1 Conducted Emission Test Setup 2.2 Radiated Emission Test Setup 30MHz to 1GHz SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 4 Page 4 of 4 Above 1GHz 2.3 RF Conducted Test Setup End

Contact Information

Applicant

Michael Roesch
[email protected]+49 6081 9419753Fax: +49 6081 9419 1753

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Parlam Zhan
[email protected]86 21 61915666

588 West Jindu Road, Xinqiao, Songjiang · Shanghai · China

Test Firm

SGS-CSTC Standards Technical Services Co.,Ltd.Lola Yuan
[email protected]+86 (0)21 6191 5609

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz7.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted.

Other Applications from Adam Hall GmbH

CARDIOID COLUMN PA SYSTEM - FCC ID 2AFF6-3G44IUAM - Adam Hall GmbH
2AFF6-3G44IUAM

CARDIOID COLUMN PA SYSTEM

Aug 21, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SPEAKER BOX - FCC ID 2AFF6-21YNNADL - Adam Hall GmbH
2AFF6-21YNNADL

SPEAKER BOX

Jan 08, 2026

Equipment Class

DTS - Digital Transmission System
Mixing Amplifier - FCC ID 2AFF6-021AMIDL - Adam Hall GmbH
2AFF6-021AMIDL

Mixing Amplifier

Aug 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Stage luminaire - FCC ID 2AFF6-SUPOLC - Adam Hall GmbH
2AFF6-SUPOLC

Stage luminaire

Feb 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HID Stage Luminaire - FCC ID 2AFF6-SOTOLC - Adam Hall GmbH
2AFF6-SOTOLC

HID Stage Luminaire

Feb 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter