FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PowerFleet Inc./
  3. 2AG69MSV2

2AG69MSV2Multisense

PowerFleet Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 26, 2024
Application Purpose
Original Equipment
Date of Application
Aug 26, 2024
Equipment Note
Multisense
Frequency Range
2402.00000000 - 2480.00000000
Company
PowerFleet Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

PowerFleet Inc. Section 2.911(d)(5)(i) Certification – Equipment Type Company name: PowerFleet Inc. Address: 123 Tice Boulevard Suite 101, Woodcliff Lake, NJ 07677, United States Product Name: Multisense FCC ID: 2AG69MSV2 Model(s): Environmental Sensor 2.911(d)(5)(i) Equipment Type We, [PowerFleet Inc.] certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Signature: Name: Lior Musi Date: 2024-06-18 Title and Company name: V.P R&D and PowerFleet Inc. NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

PowerFleet Inc. Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: PowerFleet Inc. Address: 123 Tice Boulevard Suite 101, Woodcliff Lake, NJ 07677, United States Product Name: Multisense FCC ID: 2AG69MSV2 Model(s): Environmental Sensor 2.911(d)(5)(ii) Applicant filing We, [PowerFleet Inc.] certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Signature: Name: Lior Musi Date: 2024-06-18 Title and Company name: V.P R&D and PowerFleet Inc. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Cover Letter(s)

PowerFleet Inc. Agent Authorization Company: PowerFleet Inc. Address: 123 Tice Boulevard Suite 101, Woodcliff Lake, NJ 07677, United States Product Name: Multisense Model Number(s): Environmental Sensor Product Description: Multisense We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2024-06-18 Name: Lior Musi Title: V.P R&D Company: PowerFleet Inc.

Cover Letter(s)

< PowerFleet Inc.> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 2024-06-18 Subject; Request for Long Term Confidentiality FCC ID: 2AG69MSV2 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Pursuant to Public Notice DA 04-1705 of the Commission' s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuanttoKDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Lior Musi Title: V.P R&D

ID Label/Location Info

Label location

RF Exposure Info

FCC ID: 2AG69MSV2 RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. For BT LE mode Frequency (MHz) Output power (dBm) Output power (mw) Ant gain (dBi) EIRP (dBm) ERP (dBm) ERP (mw) Distance (cm) P th (mW) 2480 3.73 2.36 -0.86 2.87 0.72 1.18 0.5 2.72 ERP = EIRP −2.15 dB WORSE CASE 2.36mW<2.7mW Remark: Then SAR evaluation is not required

Test Report

Page 1 of 8R-XC-COP30-06V1.1 Report No. : XCL-AC202407-0036 TEST REPORT Product Name:Environmental Sensor/Asset Monitor Model: Mental Sensor/Asset Test Sort:External Commission Test Client:PowerFleet inc Test by:Xingci Lab GUANGDONG XINGCI TESTING TECHNOLOGY RESEARCH Co.,Ltd. Report No.:XCL-AC202407-0036 Page 2 of 8R-XC-COP30-06V1.1 Announcement 1 . This report is invalid without seal. 2 . This report must not be partially duplicated without permission. 3 . The manufacturer would be responsible for the test samples. 4 . Xingci Lab would be only responsible for report items of the test sample , this test result is only used for scientific research, teaching, and internal control, and does not have a proof function to the society. 5 . If the client has any question about the test report, please contact our labas agreed within 15 days. Disagreement couldn’t be accepted over 15 days. 6 . Test report inquires telephone No.:+ 86-757-87744743 Add: No#4, Jinye 2nd road, Yundonghai street, Sanshui, Foshan,Guangdong Province, China,528100 Tel : 0086-(0757)-87744743 Post Code : 528100 Report No.:XCL-AC202407-0036 Page 3 of 8R-XC-COP30-06V1.1 Test Report Product Name Environmental Sensor/Asset Monitor Manufacture Date / Product ModelMental Sensor/AssetBrand Name/ Client NamePowerFleet inc Address123 Tice Blvd. Suite 101 Woodcliff Lake, NJ 07677 Test TypeExternal Commission Test Test Place SG64 Anechoic Chamber (Guangdong Xingci testing technology research Co.,Ltd.) Sample Qty1pcTest DateJul 11, 2024 Test Environment Temperature :( 21 ~ 22 )°C Relative Humidity :( 63 ~ 66 ) % Test Item Electrical performance : Radiation Pattern, Gain,Efficiency,VSWR Test Standard According to the client′s requirements, refer to the following standard : IEEE Std 149 TM -2021 IEEE Recommended Practice for Antenna Measurements Test Description Guangdong Xingci testing technology research Co., Ltd. tested the electrical performance of 1pc of Environmental Sensor/Asset Monitor under the guideline of relevant standard. Please see test result in page 5, Radiation Patterns in page 6, VSWR in page 6. Remarks Tested by: Date : Checked by : Date : Approved by : ( Authorized signatory ) Date : Report No.:XCL-AC202407-0036 Page 4 of 8R-XC-COP30-06V1.1 Sample Description Sample Number ItemSample NumberSerial Number 1 AC2024071105/ Accessories  No□ Yes: Outlook/Appearance  Qualified□ Unqualified : Status at the beginning of Test Working Normally □ Working Abnormally : Status after Test  Working Normally □ Other : Photograph□ No  In pages 7-8 Remarks ( Provided by the customer ) Antenna size : 23.57mm × 5.5mm Device size : 56mm × 23mm Device weight : 7.5402g Report No.:XCL-AC202407-0036 Page 5 of 8R-XC-COP30-06V1.1 Electrical Performance Test Result Item Test Item Technical Requirement Unit Test Frequency (MHz) Test Result 1Gain / dBi 2400-2.67 2410-2.82 2420-2.55 2430-2.60 2440-2.76 2450-2.05 2460-1.76 2470-1.28 2480-0.86 2483.5-0.92 2 Efficiency/% 240016.88 241016.17 242017.03 243017.50 244017.59 245019.99 246020.89 247022.33 248023.14 2483.522.74 3 VSWR//2400-2483.56.13 4 Radiation Pattern //2400-2483.5Page 6 Note:Test Method: Near Field Measurement Method. Report No.:XCL-AC202407-0036 Page 6 of 8R-XC-COP30-06V1.1 Radiation Pattern Vertical Radiation PatternHorizontal Radiation Pattern VSWR Report No.:XCL-AC202407-0036 Page 7 of 8R-XC-COP30-06V1.1 Sample photo Radiation Pattern Test site Report No.:XCL-AC202407-0036 Page 8 of 8R-XC-COP30-06V1.1 VSWR Test site Main instruments and equipment for testing and test system -----------End of Report----------- No.NAMEModel SERIAL NUMBER VALIDITY DATE (DD/MM/YY) 1Analog Signal Generator N5172BMY59100269 05/03/2025 2Analog Signal GeneratorN5181AMY50140747 05/03/2025 3Standard Gain AntennaSH400-440XCA01422/11/2024 4 ENA Series Network Analyzer E5062AXCRE043 06/08/2024 5 Microwave Anechoic Chamber 5m×5m×5m XCC03 23/08/2024 6 SG64 Antenna Test System SATENV 2.0.1.5 Build12 XCXT03N/A

Test Report

Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 15 1. Duty Cycle 1.1 Ant1 1.1.1 Test Result Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 1M SISO 2402 100.000 100.000 100.00 0.00 0.00 2440 100.000 100.000 100.00 0.00 0.00 2480 100.000 100.000 100.00 0.00 0.00 1.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 15 2. Bandwidth 2.1 OBW 2.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 1.045 / Pass 2440 1 1.058 / Pass 2480 1 1.068 / Pass 2.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 15 2.2 6dB BW 2.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.699 >=0.5 Pass 2440 1 0.707 >=0.5 Pass 2480 1 0.750 >=0.5 Pass 2.2.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 15 3. Maximum Conducted Output Power 3.1 Power 3.1.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 3.43 <=30 Pass 2440 3.47 <=30 Pass 2480 3.73 <=30 Pass 3.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 15 4. Maximum Power Spectral Density 4.1 PSD 4.1.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit 1M SISO 2402 -9.16 <=8 Pass 2440 -8.90 <=8 Pass 2480 -9.34 <=8 Pass Note1: Antenna Gain: Ant1: 2.28dBi; 4.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 15 5. Unwanted Emissions In Non-restricted Frequency Bands 5.1 Ref 5.1.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO 2402 1 3.32 2440 1 3.36 2480 1 2.83 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. 5.1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 15 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Report No.:GTS2024050084F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 15 5.2 CSE 5.2.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict 1M SISO 2402 1 3.36 -16.64 Pass 2440 1 3.36 -16.64 Pass 2480 1 3.36 -16.64 Pass Note1: Refer to FCC Part 15.247 (d) and ANSI…

Text truncated - open the document above for the full version.

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS2024050084 F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 24 TEST REPORT Applicant: PowerFleet Inc. Address of Applicant: 123 Tice Boulevard Suite 101, Woodcliff Lake, NJ 07677, United States Manufacturer: PowerFleet Inc. Address of Manufacturer: 123 Tice Boulevard Suite 101, Woodcliff Lake, NJ 07677, United States Equipment Under Test (EUT) Product Name: Multisense Model No.: Environmental Sensor FCC ID: 2AG69MSV2 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: May 10, 2024 Date of Test: May 10, 2024-June 17, 2024 Date of report issued: June 18, 2024 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2024050084 F01 Page 2 of 24 2 Version Version No. Date Description 00 June 18, 2024 Original Prepared By: Date: June 18, 2024 Project Engineer Check By: Date: June 18, 2024 Reviewer Report No.: GTS2024050084 F01 Page 3 of 24 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED OUTPUT POWER ........................................................................................................... 11 7.3 CHANNEL BANDWIDTH ...................................................................................................................... 12 7.4 POWER SPECTRAL DENSITY ............................................................................................................. 13 7.5 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 14 7.5.1 Conducted Emission Method ..................................................................................................... 14 7.5.2 Radiated Emission Method ........................................................................................................ 15 8 TEST SETUP PHOTO ............................................................................................................................ 24 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 24 Report No.: GTS2024050084 F01 Page 4 of 24 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass AC Power Line Conducted Emission 15.207 N/A Conducted Output Power 15.247 (b)(3) Pass Channel Bandwidth 15.247 (a)(2) Pass Power Spectral Density 15.247 (e) Pass Band Edge 15.247(d) Pass Spurious Emission 15.205/15.209 Pass Remarks: 1. Pass: The EUT complies with the essential requirements in the standard. 2. N/A:Not applicable. 3. Test according to ANSI C63.10:2013 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 9kHz-30MHz 3.1dB (1) Radiated Emission 30MHz-200MHz 3.8039dB (1) Radiated Emission 200MHz-1GHz 3.9679dB (1) Radiated Emission 1GHz-18GHz 4.29dB (1) Radiated Emission 18GHz-40GHz 3.30dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 3.44dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Report No.: GTS2024050084 F01 Page 5 of 24 5 General Information 5.1 General Description of EUT Product Name: Multisense Model No.: Environmental Sensor Test sample(s) ID: GTS2024050084-1 Sample(s) Status: Engineer sample S/N: N/A Operation Frequency: 2402MHz~2480MHz Channel Numbers: 4…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Lior Musi(V.P R&D)
[email protected]+972-73-2622330Fax: +972-3-5723100

Technical Contact

PowerFleet Inc.
[email protected]

United States

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.36 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from PowerFleet Inc.

MVAC 3.5 - FCC ID 2AG69MVAC35 - PowerFleet Inc.
2AG69MVAC35

MVAC 3.5

Jan 10, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
LV300\Cellotrack Power LTE - FCC ID 2AG69LV300N - PowerFleet Inc.
2AG69LV300N

LV300\Cellotrack Power LTE

Mar 23, 2023

Equipment Class

DTS - Digital Transmission System
LV500\Cellotrack Solar - FCC ID 2AG69LV5XXN - PowerFleet Inc.
2AG69LV5XXN

LV500\Cellotrack Solar

Mar 06, 2023

Equipment Class

DTS - Digital Transmission System
CelloCANiQ-M - FCC ID 2AG69CELLOM - PowerFleet Inc.
2AG69CELLOM

CelloCANiQ-M

Jul 16, 2022

Equipment Class