GDE25175-01 04/2020 1/8 PowerLogic TM - PowerTag R 3P/3P+N - A9MEM1590 - A9MEM1591 - A9MEM1592 - A9MEM1593 GDE25175 it pt zh ru de es Wireless Communication Energy Sensor Capteur d’énergie à communication sans fil Sensor de energía a comunicación inalambrica Kabelloser Kommunikationsenergiesensor Sensore a comunicazione wireless Sensor de energia com comunição sem fios Датчик энергии беспроводной связи 无线通讯能量传感器 fr en This instruction sheet must be kept for future use. PLEASE NOTE p Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. p PowerTag devices must not be repaired. p PowerTag devices should not be installed if, while unpacking, any damage is observed. p The PowerTag devices must be installed inside electrical panels or switchboards, behind a door or plate, so that they are inaccessible to unauthorised persons. p The electric panels must meet the requirements of the applicable standards (IEC 61439-1) and installed in compliance with current installation and safety rules (IEC 61140). p All relevant local, regional, and national regulations must be respected while installing and using PowerTag devices. p No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. La présente instruction de service doit être conservée pour une utilisation future. REMARQUE IMPORTANTE p L’installation, l’utilisation, la réparation et la maintenance des équipements électriques doivent être assurés uniquement par du personnel qualifié. p Les appareils PowerTag ne doivent pas être réparés. p Les appareils PowerTag ne doivent pas être installés si vous constatez lors du déballage que ceux-ci sont endommagés. p Les appareils PowerTag doivent être installés à l’intérieur de tableaux ou coffrets électriques, derrière une porte ou un plastron, de telle sorte qu’ils ne soient pas accessibles par une personne non-autorisée. p Les tableaux ou coffrets électriques doivent satisfaire les exigences des normes applicables (CEI 61439-1), et être installés selon les règles d’installation et de sécurité en vigueur (CEI 61140). p Toutes les réglementations locales, régionales et nationales pertinentes doivent être respectées lors de l’installation et de l’utilisation des appareils PowerTag. p Schneider Electric décline toute responsabilité quant aux conséquences de l’utilisation de ce matériel. Se recomienda conservar esta guía de servicio para utilizarla en el futuro. TENGA EN CUENTA p La instalación, manejo, puesta en servicio y mantenimiento de equipos eléctricos deberán ser realizados sólo por personal cualificado. p Los dispositivos PowerTag no pueden repararse. p Si durante el desembalaje observa que los dispositivos PowerTag están dañados, no los instale. p El PowerTag se debe instalar dentro de una caja o panel eléctrico, tras una puerta o una placa para que no puedan acceder a él personas no autorizadas. p Las cajas o paneles eléctricos deben cumplir los requisitos de los estándares correspondientes (IEC 61439-1), y se deben instalar de acuerdo con las normas de instalación y seguridad actuales (IEC 61140). p Durante la instalación y el uso de los dispositivos PowerTag, se deben respetar todas las normativas locales, regionales y nacionales correspondientes. p Schneider Electric no se hace responsable de ninguna de las consecuencias del uso de este material. Bewahren Sie diese Bedienungsanleitung bitte unbedingt zur späteren Verwendung auf. BITTE BEACHTEN p Elektrische Geräte dürfen nur von Fachpersonal installiert, betrieben, bedient und gewartet werden. p PowerTag-Geräte dürfen nicht repariert werden. p Installieren Sie PowerTag-Geräte nicht, wenn Sie bei der Entnahme aus der Verpackung Schäden an dem Produkt feststellen. p Der PowerTag muss in elektrischen Verteilungen oder Anlagen immer Verteilungen oder Anlagen immer hinter einer Tür oder Frontplatte installiert werden, um den Zugriff und das Berühren durch nicht qualifizierte Personen zu verhindern. p Die elektrischen Verteilungen oder Schaltanlagen müssen den industriellen Normen entsprechen (IEC 61439-1) und gemäß aktueller Installations- und Sicherheitsrichtlinien (IEC 61140) installiert sein. p Bei der Installation und Verwendung von PowerTag-Geräten sind alle geltenden örtlichen, regionalen und nationalen Regelungen und Vorschriften einzuhalten. p Schneider Electric haftet nicht für Schäden, die durch die Verwendung dieses Materials entstehen. Conservare le presenti istruzioni di manutenzione per riferimento futuro. NOTA p Manutenzione, riparazione, installazione e uso delle apparecchiature elettriche si devono affidare solo a personale qualificato. p I dispositivi PowerTag non devono essere riparati. p I dispositivi PowerTag non devono essere installati se durante il disimballaggio si notano parti danneggiate. p Il PowerTag deve essere installato in quadri elettrici dove deve essere protetto da uno sportello o una piastra, affinché non vi possa accedere personale non autorizzato. p I quadri devono soddisfare i requisiti delle norme in vigore (IEC 61439-1) ed essere installati in conformità alle norme di sicurezza e di installazione correnti (IEC 61140). p Rispettare tutte le normative locali, regionali e nazionali durante l’installazione e l’uso dei dispositivi PowerTag. p Schneider Electric non si assume alcuna responsabilità per qualsiasi conseguenza derivante dall’uso di questo materiale. Este guia de instalação deve ser guardado para utilização futura. NOTA p A instalação, utilização e manutenção do equipamento eléctrico devem ser efectuadas exclusivamente por pessoal qualificado. p Os dispositivos PowerTag não devem ser reparados. p Os sensores de energia PowerTag não devem ser instalados se, durante a abertura, verificar que estão danificados. p Os PowerTag devem ser instalados no interior de quadros elétricos com porta, de forma a impedir o acesso a pessoas não autorizadas. p Os quadros elétricos devem cumprir os requisitos das normas ap…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (obsolete) 4.0 5.0 Sep-16-2014 Updated company name & logo (current) 5.0 6.0 Jun-27-2018 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 6.0 Schneider Electric Industries SAS 2020.6.11 To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Schneider Electric Industries SAS hereby authorize Bureau Veritas Consumer Product Services, Inc. to act as a Certification Body for certifying for the following project(s): FCC ID: 2AH7L- MEM159X Product Description: Energy Sensor Model: A9MEM1590, A9MEM1591, A9MEM1592,A9MEM1593 Sincerely, Client’s signature Client’s name: Christophe Pretavoine Title : Contact information / address : 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 6.0 Schneider Electric Industries SAS 2020.6.11 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AH7L-MEM159X Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name: Christophe Pretavoine Title : Director for Products certifications and conformity assessment Contact information / address : 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France
SCHNEIDER ELECTRIC INDUSTRIES SAS Declaration of Identical Product Hereby, Name of manufacturer: SCHNEIDER ELECTRIC INDUSTRIES SAS Address: 31 rue Pierre Mendes France - Eybens City: 38050 - Grenoble Country: FRANCE declares that: Product description: Energy Sensor Type designation(s): A9MEM1590 Trademark: Family name A9MEM1591, A9MEM1592, A9MEM1593 is technically identical to: Product description: Energy Sensor Type designation: A9MEM1591, A9MEM1592, A9MEM1593 Trademark: Certificate number (if applicable) Date: 2020.5.26 City: Eybens Name: Signature Except for different model names, other internal structures and PCB layout are identical Christophe Pretavoine
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 191129N012 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 191129N012 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 191129N012 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 191129N012
All information and data contained in this document are the exclusive property of Schneider Electric Industries SAS and may neither be used nor disclosed without its prior written consent Number : State : Revision :Sheet : Scale :Tolerancing standard :Units of measure : GDE227610104 1/1 PRODUCT ASSY POWERTAG ROPE SENSOR SCHNEIDER PRODUCT ASSY POWERTAG ROPE SENSOR SCHNEIDER 1:1 ± 0.2Millimeter V1.001.001PP-YY-ww-D-ll-xxxx RF-Id:FF80 0000 RF-Id:FF80 0000 PPYYWWD Made in Latvia 3N 100−277/173−480 V 50/60 Hz Imax: 2000 A Ib: 300 A 3 VA CAT IV se.com/contact E496043 FCC ID: 2AH7L-MEM159X IC: 21522-MEM159X CS 30323 - F-92506 Schneider Electric Rueil-Malmaison Cedex Range Name Arial Rounded. 6pt Product Name Arial Rounded. 5pt Commercial ref erence Arial Rounded. 4.5pt RF-Id( Variable data) Arial Rounded. 4.5pt RF-Id last four digits Arial Rounded Bold. 5pt 0 1.515.4 2.4 2 Centered with green bar Centered with green bar 8.1 19 33 10.3 35.2 12.5 QR Code (Variable data) Date Code (Variable data) Arial Rounded regular 3pt 6.9 Center 11.6 Center 19 Center 26.4 Center 33.8 45 12.6 4.2 6 50.9 53.9 68.9 22.6 Center 47 7.6 18.7 15.5 13.4 11.5 9.5 Color of markings SE Grey 6 52.4 18.1 13.523.733.944 0 Text Arial Rounded. 4.5pt GDE97321 Imax Ib 28.6 Center Center 41.2 45.9 16.9 17.5 55.3 34.6 Center 40.6 Center 46.6 Center 3.75 3.23.23.23.2 10 556 5 5 Commercial Ref. Product name Imax20060010002000 Ib30100 150 300 Date Code Ref . Com. Ref erence 13x13 mm maxi QR Code FORMAT DU CONTENU / CONTENT FORMAT http://go2se.com/ref=<COMMERCIAL_REF>/sn=<SERIAL-NUMBER>/zb=<RF-Id> • http:/go2se.com • /ref=<COMMERCIAL_REF> is the commercial reference of the product (9 characters) • /sn=<SERIAL-NUMBER> PPYYwwDIIxxxx - PP = Plant code (ex : Schneider VFE: RN) - YY = Year - ww = Week (ex : 25) - D = Day of week between 1 and 7 : 1 (Monday) and 7 (Sunday) - II = Line or machine number or team - xxxx = Unique product number during the day. The number was RAZ at 0am • /zb=<RF-Id> Wireless address of the product (8 characters max.) PPYYWWD A9MEM1593 - PP = Plant code (ex : Schneider VFE: RN) - YY = Year - WW = Week (ex : 25) - D = Day of week between 1 and 7 : 1 (Monday) and 7 (Sunday) RF-id Wireless address of the product : 8 characters - Numbers & capital letters R200 A9MEM1590 R600 A9MEM1591 R1000 A9MEM1592 R2000 A9MEM1593 Creation Printed on 2020/06/23
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 2 Report Version 1 Reference No.: 191129N012 PHOTOGRAPHS OF THE EUT RF ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 2 Report Version 1 Reference No.: 191129N012
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM200421N030 RF EXPOSURE REPORT Applicant Schneider Electric Industries SAS Address 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France Manufacturer or Supplier Schneider Electric Industries SAS Address 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France Product Energy Sensor Brand Name Model A9MEM1590 Additional Model & Model Difference A9MEM1591, A9MEM1592, A9MEM1593, see items 1.1 Date of tests Nov. 29, 2019 ~ Mar. 27, 2020 FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Tom Chen Project Engineer / EMC Department Approved by Glyn He Assistant Manager/ EMC Department Date: May 22, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM200421N030 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE LIMIT ..................................................................................... 5 3. MPE CALCULATION FORMULA ..................................................................... 5 4. CLASSIFICATION ........................................................................................... 5 5. ANTENNA GAIN .............................................................................................. 6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM200421N030 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM191129N012 Original release May 11, 2020 FM200421N030 Based on the original report FM191129N012 changed the address of applicant/ manufacturer, FCC ID, brand name and model No., but it doesn’t need to be retested. May 22, 2020 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM200421N030 1. CERTIFICATION FCC ID: 2AH7L-MEM159X PRODUCT: Energy Sensor BRAND NAME: MODEL NO.: A9MEM1590 ADDITIONAL NO.: A9MEM1591, A9MEM1592, A9MEM1593 TEST SAMPLE: Engineering Sample APPLICANT: Schneider electric industries SAS STANDARDS: FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 NOTES: 1. Additional models (see about table) are identical with the test model A9MEM1590 except the model name for trading purpose Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM200421N030 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Bureau Veritas She…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 41 Report Version 1 Test Report No.: RF200421N030 TEST REPORT Applicant Schneider Electric Industries SAS Address 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France Manufacturer or Supplier Schneider Electric Industries SAS Address 31 rue Pierre Mendes France, Eybens Grenoble cedex 9, 38050 France Product Energy Sensor Brand Name Model A9MEM1590 Additional Model & Model Difference A9MEM1591, A9MEM1592, A9MEM1593, see items 3.1 Date of tests Nov. 29, 2019 ~ Mar. 27, 2020 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Tom Chen Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: May 22, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 41 Report Version 1 Test Report No.: RF200421N030 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT........................................................................................... 6 3.2 DESCRIPTION OF TEST MODES............................................................................................. 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 8 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 10 3.4 DESCRIPTION OF SUPPORT UNITS ..................................................................................... 10 4 TEST TYPES AND RESULTS .......................................................................................................11 4.1. CONDUCTED EMISSION MEASUREMENT ....................................................................... 11 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................ 11 4.1.2 TEST INSTRUMENTS ...................................................................................................... 11 4.1.3 TEST PROCEDURES ..................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 12 4.1.5 TEST SETUP ................................................................................................................... 13 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 13 4.1.7 TEST RESULTS .............................................................................................................. 14 4.2. RADIATED EMISSION MEASUREMENT ........................................................................... 16 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 16 4.2.2 TEST INSTRUMENTS ..................................................................................................... 17 4.2.3 TEST PROCEDURES ..................................................................................................... 18 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 19 4.2.5 TEST SETUP ................................................................................................................... 19 4.2.6 EUT OPERATING CONDITIONS .......................................................…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 191129N012 SET-UP FOR CONDUCTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 191129N012 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 191129N012 Frequency Range< Above 1GHz >
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 11.09 mW |

PowerTag F63 3P 480V
Equipment Class
DTS - Digital Transmission System
Wireless sensor for early detection of overheating cables
Equipment Class
DTS - Digital Transmission System
Ecostruxure Panel Server
Equipment Class
DTS - Digital Transmission System
PowerLogic Tag Display
Equipment Class
DTS - Digital Transmission System
Energy Sensor
Equipment Class
DTS - Digital Transmission System