FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schneider Electric Industrie SAS/
  3. 2AH7L-UPSB

2AH7L-UPSBEcostruxure Panel Server

Schneider Electric Industrie SAS
Ecostruxure Panel Server - FCC ID 2AH7L-UPSB - Schneider Electric Industrie SAS
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 08, 2021
Application Purpose
Original Equipment
Date of Application
Mar 07, 2021
Equipment Note
Ecostruxure Panel Server
Frequency Range
2402.00000000 - 2480.00000000
Company
Schneider Electric Industrie SAS
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EcoStruxure™ Panel Server GDE7411902 www.se.com/support Guarde la hoja de instrucciones para utilizarla en el futuro. Visite nuestra página web en www.se.com para descargar los documentos enumerados anteriormente (manuales de usuario ) así como otros documentos. TENGA EN CUENTA p La instalación, manejo, puesta en servicio y mantenimiento de equipos eléctricos deberán ser realizados sólo por personal cualificado. p Al instalar y utilizar este producto es necesario tener en cuenta todas las regulaciones sobre seguridad correspondientes, ya sean regionales, locales o estatales. p Schneider Electric no se hace responsable de ninguna de las consecuencias del uso de este material. Bewahren Sie die Kurzanleitung als Referenz für den späteren Gebrauch auf. Besuchen Sie unsere Website unter www.se.com um die oben aufgeführten Dokumente (Benutzerhandbücher ) und weitere Dokumente herunterzuladen. BITTE BEACHTEN p Elektrische Geräte dürfen nur von Fachpersonal installiert, betrieben, bedient und gewartet werden. p Bei der Montage und Verwendung dieses Produkts sind alle zutreffenden staatlichen, landesspezifischen, regionalen und lokalen Sicherheitsbestimmungen zu beachten. p Schneider Electric haftet nicht für Schäden, die durch die Verwendung dieses Materials entstehen. Retain instruction sheet for future use. Visit our website at www.se.com to download the documents listed above (user guides ) and other documents. PLEASE NOTE p Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. p All pertinent state, regional, and local safety regulations must be observed when installing and using this product. p No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Instruction de service à conserver pour usage ultérieur. Visitez notre site web www.se.com pour télécharger les documents listés ci-dessus (guide utilisateurs ) et d'autres documents. REMARQUE IMPORTANTE p L’installation, l’utilisation, la réparation et la maintenance des équipements électriques doivent être assurées par du personnel qualifié uniquement. p Toutes les réglementations locales, régionales et nationales pertinentes doivent être respectées lors de l'installation et de l'utilisation de ce produit. p Schneider Electric décline toute responsabilité quant aux conséquences de l’utilisation de ce matériel. U G U G Guarde a folha de instruções para utilização futura. Visite o nosso site web em www.se.com para transferir os documentos indicados acima (manuais de utilizador ) e outros documentos. NOTA p A instalação, utilização e manutenção do equipamento eléctrico devem ser efectuadas exclusivamente por pessoal qualificado. p Todos os regulamentos de segurança relevantes, sejam estatais, regionais ou locais, devem ser tomados em consideração quando instalar e utilizar este produto. p A Schneider Electric não assume qualquer responsabilidade pelas consequências resultantes da utilização deste material. Сохраните эту инструкцию для использования в будущем. Посетите наш веб-сайт www.se.com чтобы загрузить перечисленные выше документы (руководства пользователя ) и другие публикации. ОБРАТИТЕ ВНИМАНИЕ p Установка, эксплуатация, ремонт и обслуживание электрического оборудования может выполняться только квалифицированными электриками. p Во время установки и использования данного продукта следует соблюдать все действующие государственные, региональные и местные правила безопасности. p Компания Schneider Electric не несет никакой ответственности за любые возможные последствия использования данной документации. 请保管好此说明书以供将来使用。 请访问网站 www.se.com 以下载上述文件 (用户指南 )和其他文件。 请注意 p 电气设备的安装、操作、维修和维护工作 仅限于合格人员执行。 p 在安装和使用本产品时,必须遵守国家、 地区和当地的所有相关的安全法规。 p Schneider Electric 不承担由于使用本资料 所引起的 任何后果。 Conservare questo foglio di istruzioni per un utilizzo futuro. Visitate il nostro sito web www.se.com per scaricare i documenti elencati sopra (Guide utente ) e altri documenti. NOTA p Manutenzione, riparazione, installazione e uso delle apparecchiature elettriche si devono affidare solo a personale qualificato. p Durante l'installazione e l'uso di questo prodotto è necessario rispettare tutte le normative locali, nazionali o internazionali in materia di sicurezza. p Schneider Electric non si assume alcuna responsabilità per qualsiasi conseguenza derivante dall’uso di questo materiale. U G U G U G U G U G U G GDE74119-02 04/2021 1/12 www.se.com EcoStruxure Panel Server U G EcoStruxure Panel Server Universal PAS600L Panel Server Power 24V c 2 1 Digital Inputs 6 5 4 3 I1 I1C I2C I2 GDE74119 es fr en DOCA0172EN DOCA0172FR DOCA0172ES DOCA0172DE DOCA0172IT DOCA0172PT DOCA0172RU it pt ru de EPG400 EPG400L it pt zh ru de es Bluetooth ® Wireless Technology Enabled Products Produits activés pour la technologie sans fil Bluetooth® Productos con tecnología inalámbrica Bluetooth® Produkte mit Bluetooth®-basierter Wireless-Technologie Prodotti compatibili con tecnologia wireless Bluetooth® Produtos habilitados para tecnologia sem fio Bluetooth® Изделия с поддержкой технологии беспроводной связи Bluetooth® 支持 Bluetooth® 无线技术的产品 fr en 2/12GDE74119-02 RISCO DE ELECTROCUSSÃO, DE EXPLOSÃO, OU DE ARCO ELÉCTRICO A não observância destas instruções resultará em morte, ou ferimentos graves. RISCHIO DI FOLGORAZIONE, ESPLOSIONI O ARCO ELETTRICO Il mancato rispetto di queste istruzioni provocherà morte o gravi infortuni. GEFAHR VON ELEKTRISCHEM SCHLAG, EXPLOSION ODER LICHTBOGEN p Tragen Sie persönliche Schutzausrüstung (PSA) und befolgen Sie sichere Verfahren im Umgang mit Elektrogeräten. Siehe NFPA 70E, CSA Z462, NOM-029-STPS oder lokale Entsprechung. p Diese Geräte dürfen nur von qualifizierten Elektrikern installiert und gewartet werden. p Schalten Sie vor Arbeiten am bzw. im Innern des Geräts die gesamte Spannungsversorgung ab. p Verwenden Sie für die Prüfung vorhandener Spannung stets einen Spannungsfühler mit zutreffender Bemessungsspannung. p Bringen Sie alle Vorrichtungen, Türen und Ab…

Text truncated - open the document above for the full version.

Attestation Statements

Date: February 1, 2021 We, Schneider Electric Industries SAS declare that the device does not support channel 12 ~ 13 in 2.4GHz band and any non-US channels in all the operational mode(s) for the following product. FCC ID: 2AH7L-UPSB If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! ----------------------------------- Christophe PRETAVOINE / Director for Products Conformity Assessment and Certification Schneider Electric Industrie SAS Tel: +33 4 7660 7062 x367062 E-mail: [email protected]

Cover Letter(s)

Date: 2021-02-01 FCC ID: 2AH7L-UPSB To the attention of Federal Communications Commission Authorization and Evaluation Division Permanent Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ----------------------------------- Christophe PRETAVOINE / Director for Products Conformity Assessment and Certification Schneider Electric Industrie SAS Tel: +33 4 7660 7062 x367062 E-mail: [email protected]

Cover Letter(s)

Date: 2021-02-17 FCC ID: 2AH7L-UPSB To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 90 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ----------------------------------- Christophe PRETAVOINE / Director for Products Conformity Assessment and Certification Schneider Electric Industrie SAS Tel: +33 4 7660 7062 x367062 E-mail: [email protected]

Cover Letter(s)

Date: 2021-02-01 FCC ID: 2AH7L-UPSB A U T H O R I Z A T I O N L E T T E R To Whom It May Concern: Schneider Electric Industries SAS hereby authorizes Andrea Hsia/Supervisor of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (“BV CPS Taoyuan”), to act on its behalf in all matters relating to the Federal Communication Commission (“FCC”) application for equipment authorization in connection with the FCC ID listed above, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia/Supervisor of BV CPS Taoyuan on Schneider Electric Industries SAS’s behalf, within the scope of the powers granted herein, shall have the same effect as acts of its own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ----------------------------------------------- Christophe PRETAVOINE / Director for Products Conformity Assessment and Certification Schneider Electric Industrie SAS Tel: +33 4 7660 7062 x367062 E-mail: [email protected]

External Photos

Reference No.: 200605C50 1 of 6 CONSTRUCTION PHOTOS OF EUT Reference No.: 200605C50 2 of 6 Reference No.: 200605C50 3 of 6 Reference No.: 200605C50 4 of 6 Reference No.: 200605C50 5 of 6 Reference No.: 200605C50 6 of 6

ID Label/Location Info

Schneider Electric. 35 rue Joseph Monier, CS 30323 F - 92506, Rueil Malmaison Cedex EcoStruxure TM Panel Server Made in India Designed by Schneider Electric FCC ID : 2AH7L-UPSB IC : 21522-UPSB Data gateway IEC 62974-1 class 2 PAS600L 24V (±10%) 125mA, < 3W PPYYWWDLXXXX -25°C to 70°C Schneider Electric. 35 rue Joseph Monier, CS 30323 F - 92506, Rueil Malmaison Cedex EcoStruxure TM Panel Server Made in India Designed by Schneider Electric FCC ID : 2AH7L-UPSB IC : 21522-UPSB Data gateway IEC 62974-1 class 2 PAS600L 24V (±10%) 125mA, < 3W PPYYWWDLXXXX -25°C to 70°C Schneider Electric. 35 rue Joseph Monier, CS 30323 F - 92506, Rueil Malmaison Cedex EcoStruxure TM Panel Server Made in India Designed by Schneider Electric FCC ID : 2AH7L-UPSB IC : 21522-UPSB Data gateway IEC 62974-1 class 2 PAS600L 24V (±10%) 125mA, < 3W PPYYWWDLXXXX -25°C to 70°C NNZ1604201 PRODUCT LABEL_PANEL SERVER 04 2/3 Commercial reference Arial Rounded Bold 6pt (Height 1.56mm) Product description Arial Rounded 4.5pt (Height 1.17mm) Rating Arial Rounded 4.5pt (Height 1.17mm) Zone A (Refer tabel) Zone B (Refer tabel) Designed by Schneider Electric Arial Rounded Light 4.5pt (Height 1.17mm) Label Colour: White Glossy Text Colour: SE Grey6 (Cool Grey 11C) 17.3 3.7 0 For Serial Number of the Barcode: PPYYWWDLXXXX • PP = Plant code (for example, Attibele Plant= 54 • YY= Year • ww = Week(Ex:25) • D= Day of week between 1(Monday) and 7 (Sunday) • L = line or machine number or team • xxxx= Running Serial Number PPYYWWDLXXXX Grid for regulatory symbols. The symbols are to be centered on the x & y axis. 0 71624.232.8 20 30.1 37.1 39.1 78.272.771.369.4 67 56.755.252.249.347.2 12.5 23 32.1 23 11.2 9.3 5 3.5 28.2 3.51 2.6 4 10.4 17.2 30.3 49 18.7 COMMERCIAL REFERENCERATINGZone AZone B 110–240V~/ (±10 %) < 3W/10VA -25°C to 70°C 110–277V~/ (±10 %) < 3W/10VA -25°C to 70°C 110–277V~/ (±10 %) < XW/XXVA -25°C to 70°C ----------------------------------------- ---------------- -25°C to 70°C 24V (±10%) 125mA, < 3W -25°C to 70°C 24V (±10%) XXXmA, < XW -25°C to 70°C PAS800P PAS600L SL. No PAS600T PAS600 PAS800L PAS800 IC : XXXXXXXXXX IC : 21522-UPSB 6 1 2 3 4 5 FCC : 2AH7L-UPSB FCC : XXXXXXXXX

Internal Photos

Reference No.: 200605C50 1 of 7 CONSTRUCTION PHOTOS OF EUT Reference No.: 200605C50 2 of 7 Reference No.: 200605C50 3 of 7 Reference No.: 200605C50 4 of 7 Reference No.: 200605C50 5 of 7 Reference No.: 200605C50 6 of 7 Reference No.: 200605C50 7 of 7

RF Exposure Info

Report No.: SA200605C50 Page No. 1 / 6 Report Format Version: 6.1.1 RF Exposure Report Report No.: SA200605C50 FCC ID: 2AH7L-UPSB Test Model: PAS600L Received Date: Jun. 10, 2020 Date of Evaluation: Jul. 22, 2020 Issued Date: Dec. 24, 2020 Applicant: Schneider Electric Industries SAS Address: Electropole Site - 38EQ1, 31 rue Pierre Mendes France, Eybens - 38050 Grenoble cedex 9 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN FCC Registration / Designation Number: 788550 / TW0003 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SA200605C50 Page No. 2 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 2.4 Calculation Result of Maximum Conducted Power ............................................................................. 6 Report No.: SA200605C50 Page No. 3 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SA200605C50 Original Release Dec. 24, 2020 Report No.: SA200605C50 Page No. 4 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Ecostruxure Panel Server Brand: Schneider Electric Test Model: PAS600L Sample Status: Identical Prototype Applicant: Schneider Electric Industries SAS Date of Evaluation: Jul. 22, 2020 Standards: FCC Part 2 (Section 2.1091) References Test Guidance : KDB 447498 D01 General RF Exposure Guidance v06 IEEE C95.3 -2002 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Prepared by : , Date: Dec. 24, 2020 Gina Liu / Specialist Approved by : , Date: Dec. 24, 2020 Dylan Chiou / Senior Project Engineer Report No.: SA200605C50 Page No. 5 / 6 Report Format Version: 6.1.1 2 RF Exposure 2.1 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f 2 )* 30 30-300 27.5 0.073 0.2 30 300-1500 ... ... f/1500 30 1500-100,000 ... ... 1.0 30 f = Frequency in MHz ; *Plane-wave equivalent power density 2.2 MPE Calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA200605C50 Page No. 6 / 6 Report Format Version: 6.1.1 2.4 Calculation Result of Maximum Conducted Power Band Frequency Band (MHz) Max Power (dBm) Antenna Gain (dBi) Distance (cm) Power Density (mW/cm 2 ) Limit (mW/cm 2 ) BT 2402-2480 5.55 4.3 20 0.002 1.00 WLAN 2412-2462 17.73 4.3 20 0.032 1.00 Zigbee 2405-2475 6.32 5.1 20 0.003 1.00 Note: 1. Determining compliance based on the results of the compliance measurement, not taking into account measurement instrumentation uncertainty. 2. The above Antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible Conclusion: Both of the WLAN and BT and Zigbee can transmit simultaneously, the formula of calculated the MPE is: CPD1 / LPD1 + CPD2…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF200605C50 Page No. 1 / 51 Report Format Version: 6.1.1 FCC Test Report Report No.: RF200605C50 FCC ID: 2AH7L-UPSB Test Model: PAS600L Received Date: Jun. 10, 2020 Test Date: Jul. 03 ~ Jul. 16, 2020 Issued Date: Jul. 24, 2020 Applicant: Schneider Electric Industries SAS Address: Electropole Site - 38EQ1, 31 rue Pierre Mendes France, Eybens - 38050 Grenoble cedex 9 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: RF200605C50 Page No. 2 / 51 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ........................................................................................................................... 5 2 Summary of Test Results ........................................................................................................................... 6 2.1 Measurement Uncertainty ..................................................................................................................... 6 2.2 Modification Record .............................................................................................................................. 6 3 General Information ................................................................................................................................... 7 3.1 General Description of EUT .................................................................................................................. 7 3.2 Description of Test Modes ..................................................................................................................... 8 3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 9 3.3 Duty Cycle of Test Signal ..................................................................................................................... 11 3.4 Description of Support Units ............................................................................................................... 12 3.4.1 Configuration of System under Test ......................................................................................... 12 3.5 General Description of Applied Standards and References ............................................................... 12 4 Test Types and Results ............................................................................................................................ 13 4.1 Radiated Emission and Bandedge Measurement .............................................................................. 13 4.1.1 Limits of Radiated Emission and Bandedge Measurement ..................................................... 13 4.1.2 Test Instruments ....................................................................................................................... 14 4.1.3 Test Procedures ........................................................................................................................ 15 4.1.4 Deviation from Test Standard ................................................................................................... 15 4.1.5 Test Set Up ............................................................................................................................... 16 4.1.6 EUT Operating Conditions ........................................................................................................ 17 4.1.7 Test Results .............................................................................................................................. 18 4.2 Conducted Emission Measurement .................................................................................................... 28 4.2.1 Limits of Conducted Emission Measurement ........................................................................... 28 4.2.2 Test Instruments ....................................................................................................................... 28 4.2.3 Test Procedures ........................................................................................................................ 28 4.2.4 Deviation from Test Standard ................................................................................................... 29 4.2.5 Test Setup ............................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF200605C50-1 Page No. 1 / 89 Report Format Version: 6.1.1 FCC Test Report Report No.: RF200605C50-1 FCC ID: 2AH7L-UPSB Test Model: PAS600L Received Date: Jun. 10, 2020 Test Date: Jul. 08 ~ Oct. 21, 2020 Issued Date: Dec. 24, 2020 Applicant: Schneider Electric Industries SAS Address: Electropole Site - 38EQ1, 31 rue Pierre Mendes France, Eybens - 38050 Grenoble cedex 9 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: RF200605C50-1 Page No. 2 / 89 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ........................................................................................................................... 5 2 Summary of Test Results ........................................................................................................................... 6 2.1 Measurement Uncertainty ..................................................................................................................... 6 2.2 Modification Record .............................................................................................................................. 6 3 General Information ................................................................................................................................... 7 3.1 General Description of EUT .................................................................................................................. 7 3.2 Description of Test Modes ..................................................................................................................... 8 3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 9 3.3 Duty Cycle of Test Signal ..................................................................................................................... 11 3.4 Description of Support Units ............................................................................................................... 13 3.4.1 Configuration of System under Test ......................................................................................... 13 3.5 General Description of Applied Standards and References ............................................................... 13 4 Test Types and Results ............................................................................................................................ 14 4.1 Radiated Emission and Bandedge Measurement .............................................................................. 14 4.1.1 Limits of Radiated Emission and Bandedge Measurement ..................................................... 14 4.1.2 Test Instruments ....................................................................................................................... 15 4.1.3 Test Procedures ........................................................................................................................ 16 4.1.4 Deviation from Test Standard ................................................................................................... 17 4.1.5 Test Set Up ............................................................................................................................... 17 4.1.6 EUT Operating Conditions ........................................................................................................ 18 4.1.7 Test Results .............................................................................................................................. 19 4.2 Conducted Emission Measurement .................................................................................................... 47 4.2.1 Limits of Conducted Emission Measurement ........................................................................... 47 4.2.2 Test Instruments ....................................................................................................................... 47 4.2.3 Test Procedures ........................................................................................................................ 48 4.2.4 Deviation from Test Standard .........................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Pavana S(Deputy General Manager - Certification)
[email protected]+917760972017Fax: +33647446360

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]+886-3-2600609Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.40 GHz - 2.48 GHz4.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum conducted output power. This device supports 20 and 40 MHz bandwidth modes for WLAN. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. Only the antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter.

Other Applications from Schneider Electric Industrie SAS

PowerTag F63 3P 480V - FCC ID 2AH7L-MEM1575 - Schneider Electric Industrie SAS
2AH7L-MEM1575

PowerTag F63 3P 480V

Dec 01, 2025

Equipment Class

DTS - Digital Transmission System
Wireless sensor for early detection of overheating cables - FCC ID 2AH7L-HTAGV2 - Schneider Electric Industrie SAS
2AH7L-HTAGV2

Wireless sensor for early detection of overheating cables

Mar 16, 2021

Equipment Class

DTS - Digital Transmission System
PowerLogic Tag Display - FCC ID 2AH7L-PLTDISP - Schneider Electric Industrie SAS
2AH7L-PLTDISP

PowerLogic Tag Display

Dec 20, 2020

Equipment Class

DTS - Digital Transmission System
Energy Sensor - FCC ID 2AH7L-MEM159X - Schneider Electric Industrie SAS
2AH7L-MEM159X

Energy Sensor

Jun 29, 2020

Equipment Class

DTS - Digital Transmission System
Energy Sensor - FCC ID 2AH7L-PLTR - Schneider Electric Industrie SAS
2AH7L-PLTR

Energy Sensor

Jun 28, 2020

Equipment Class

DTS - Digital Transmission System