FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. INTERNATIONAL DEVELOPMENT COMPANY/
  3. 2AP35-LV30RM01A

2AP35-LV30RM01ARemote Controller

INTERNATIONAL DEVELOPMENT COMPANY
Remote Controller - FCC ID 2AP35-LV30RM01A - INTERNATIONAL DEVELOPMENT COMPANY
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 28, 2022
Application Purpose
Original Equipment
Date of Application
Dec 28, 2022
Equipment Note
Remote Controller
Frequency Range
2420.00000000 - 2470.00000000
Company
INTERNATIONAL DEVELOPMENT COMPANY
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SIZE: 210*95mm ( INSTRUCCIONES BACK INSTRUCTIONS FRONT FCC WARNING: WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. ********************************************************************************************** NOTES: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ADVERTENCIA: Los cambios o modificaciones a esta unidad que no hayan sido expresamente aprobados por la parte responsable del cumplimiento, puede invalidar la garantía del usuario de operar el equipo. ********************************************************************************************** ADVERTENCIA FCC NOTAS: Este equipo ha sido probado y cumple con los límites de dispositivos digitales de Clase B en virtud de la Parte 15 de las Normas FCC. Estos límites están diseñados para ofrecer una protección razonable contra las interferencias dañinas en instalaciones residenciales. Este equipo genera, utiliza y puede irradiar energía de radiofrecuencia y, si no se instala y utiliza siguiendo estas instrucciones, puede provocar interferencias dañinas a las comunicaciones de radio. Sin embargo, no se garantiza que no se produzcan interferencias en una instalación particular. Si el equipo provoca interferencias dañinas a la recepción de radio o televisión, lo cual puede determinarse encendiendo y apagando el equipo, el usuario debe corregir esa interferencia siguiendo una o varias de las siguientes medidas: Este dispositivo cumple con la parte 15 de las reglas de la FCC. La operación está sujetaa las dos condiciones siguientes: (1) este dispositivo no puede causar daños interferencia, y (2) este dispositivo debe aceptar cualquier interferencia recibida, incluyendo interferencias que pueden causar operación no deseada. Reorientar o reubicar la antena receptora. Aumentar la separación entre el equipo y el recibidor. Conectar el equipo a una salida de un circuito distinto al que está conectado el recibidor. Solicitar ayuda al vendedor o a un técnico especializado en radio/TV. • • • • EXPOSICIÓN A RF:Este equipo cumple con los límites de FCC de exposición a la radiación establecidos para ambientes no controlados. RF Exposure: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.

Cover Letter(s)

Agent Authorization Company: INTERNATIONAL DEVELOPMENT COMPANY Address: 899 Henrietta Creek Road, Roanoke, Texas 76262, United States Product Name: Remote Controller Model Number(s): LV30RM01A-06 Product Description: Remote Controller We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-12-07 Name: zhiquan li Title: Manager Company: INTERNATIONAL DEVELOPMENT COMPANY

Cover Letter(s)

INTERNATIONAL DEVELOPMENT COMPANY Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 2022-12-07 Subject; Request for Confidentiality FCC ID: 2AP35-LV30RM01A To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Pursuant to Public Notice DA 04-1705 of the Commission' s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuanttoKDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: zhiquan li Title: Manager

External Photos

Test Model No.: LV30RM01A‐06

ID Label/Location Info

FCC Label and Location Pressure-sensitive printed labels: Label location:

Internal Photos

Test Model No.: LV30RM01A‐06

RF Exposure Info

FCC ID: 2AP35-LV30RM01A RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. Frequency (MHz) Output power to antenna (dBm) Ant gain(dBi) EIRP(dBm) ERP(dBm) ERP(mw) Distance (cm) P th (mW) 2470 -8.53 2.36 -6.17 -8.32 0.147 0.5 2.7 ERP = EIRP −2.15 dB WORSE CASE 0.147mW<2.7mW Remark: Then SAR evaluation is not required

Test Report

Report No.: BL-SZ22B0928-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 12 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China TEST REPORT Applicant: Zhongshan Quanxin Lighting & Electrical Corp., Ltd. Address: Zone A, Building 1, No.1, Hongji Road, West District, Zhongshan City, Guangdong Province Equipment Type: Antenna Model Name: LV30RM01A Brand Name: N/A Test Standard: ANSI/IEEE Std 149-1979 Sample Arrival Date: Nov. 23, 2022 Test Date: Nov. 25, 2022 Date of Issue: Dec. 08, 2022 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Mai Jintian Checked by: Zou Liu Approved by: Wei Yanquan (Chief Engineer) _______________ _______________ _______________ Report No.: BL-SZ22B0928-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 12 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Revision History Version Issue Date Revisions Rev. 01 Dec. 08, 2022 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ........................................................................................................ 3 1.1 Test Laboratory ................................................................................................................... 3 1.2 Test Location ....................................................................................................................... 3 2 PRODUCT INFORMATION ....................................................................................................... 4 2.1 Applicant Information ........................................................................................................... 4 2.2 Manufacturer Information .................................................................................................... 4 2.3 General Description for Equipment under Test (EUT) ......................................................... 4 2.4 Ancillary Equipment ............................................................................................................. 4 2.5 Technical Information .......................................................................................................... 4 3 SUMMARY OF TEST RESULTS ............................................................................................... 5 3.1 Test Standards .................................................................................................................... 5 3.2 Test Verdict ......................................................................................................................... 5 3.3 Test Uncertainty .................................................................................................................. 5 4 GENERAL TEST CONFIGURATIONS ...................................................................................... 6 4.1 Test Condition ..................................................................................................................... 6 4.2 Test Equipment List ............................................................................................................. 6 4.3 Test Setup ........................................................................................................................... 7 ANNEX A TEST RESULTS ........................................................................................................... 8 A.1 Gain and Efficiency ............................................................................................................. 8 ANNEX B RADIATION PATTERN ................................................................................................ 9 ANNEX C TEST SETUP PHOTOS ............................................................................................. 11 ANNEX D EUT PHOTO .............................................................................................................. 11 Report No.: BL-SZ22B0928-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 12 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1 GENERAL INFORMATION 1.1 Test Laboratory Name Shenzhen BALUN Technology Co., Ltd. Address Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Phone Number +86 755 6685 0100 1.2 Test Location Name Shenzhen BALUN Technology Co., Ltd. Location Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ22B0928-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 12 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Zhongshan Quanxin Lighting & Electrical Corp., Ltd. Address Zone A, Building 1, No.1, Hongji Road, West District, Zhongshan City, Guangdong Province 2.2 Manufacturer Information Manufacturer N/A Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Name Antenna Model Name Under Test LV30RM01A Antenna Type PCB Antenna Dimensions 12.7*8.2 mm 2.4 Ancillary Equipment Note: Not applicable. 2.5 Technical Information Test Frequencies 2402MHz, 2450MHz, 2470MHz Report No.: BL-SZ22B0928-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 5 / 12 Web: www.titcgroup.com Template No.: TRP-Passive…

Text truncated - open the document above for the full version.

Test Report

Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 19 Appendix for 15.247 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result GFSK SISO 2420 1 9.280 Pass 2450 1 8.699 Pass 2470 1 8.566 Pass Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 19 1.1.2 Test Graph GFSK_LCH_2420MHz_Ant1_NTNV GFSK_MCH_2450MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 19 GFSK_HCH_2470MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 19 1.2 6dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit GFSK SISO 2420 1 0.966 >=0.5 Pass 2450 1 0.814 >=0.5 Pass 2470 1 0.876 >=0.5 Pass Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 19 1.2.2 Test Graph GFSK_LCH_2420MHz_Ant1_NTNV GFSK_MCH_2450MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 19 GFSK_HCH_2470MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 19 2. Maximum Conducted Output Power 2.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit GFSK SISO 2420 -9.41 <=30 Pass 2450 -8.71 <=30 Pass 2470 -8.53 <=30 Pass Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 19 2.2 Test Graph GFSK_LCH_2420MHz_Ant1_NTNV GFSK_MCH_2450MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 19 GFSK_HCH_2470MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 19 3. Maximum Power Spectral Density 3.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit GFSK SISO 2420 -16.76 <=8 Pass 2450 -16.68 <=8 Pass 2470 -16.39 <=8 Pass Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 19 3.2 Test Graph GFSK_LCH_2420MHz_Ant1_NTNV GFSK_MCH_2450MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 19 GFSK_HCH_2470MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 19 4. Unwanted Emissions In Non-restricted Frequency Bands 4.1 Ref 4.1.1 Test Result Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) GFSK SISO 2420 1 -12.21 2450 1 -11.68 2470 1 -11.58 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 19 4.1.2 Test Graph GFSK_LCH_2420MHz_Ant1_NTNV GFSK_MCH_2450MHz_Ant1_NTNV Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 19 GFSK_HCH_247…

Text truncated - open the document above for the full version.

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS202211000008F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 33 TEST REPORT Applicant: INTERNATIONAL DEVELOPMENT COMPANY Address of Applicant: 899 Henrietta Creek Road, Roanoke, Texas 76262, United States Manufacturer/Factory: 1. Zhongshan Quanxin Lighting Electrical Co., Ltd. 2. Solana Smart Lighting Co., Ltd. Address of Manufacturer/Factory: 1. Hong Ji Street, Shalang, Long Ping Cun, West District, Zhongshan Guangdong 528411 China 2. No.268 Moo 7, Huasamrong Sub-district, Plaengyao District, Chachoengsao Province, Thailand 24190 Equipment Under Test (EUT) Product Name: Remote Controller Model No.: LV30RM01A-06 FCC ID: 2AP35-LV30RM01A Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: November 03, 2022 Date of Test: November 04-21, 2022 Date of report issued: November 22, 2022 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 33 2 Version Version No. Date Description 00 November 22, 2022 Original Prepared By: Date: November 22, 2022 Project Engineer Check By: Date: November 22, 2022 Reviewer Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 33 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT ..................................................................................................................... 9 7.2 CONDUCTED OUTPUT POWER ........................................................................................................... 10 7.3 CHANNEL BANDWIDTH ...................................................................................................................... 11 7.4 POWER SPECTRAL DENSITY ............................................................................................................. 12 7.5 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 13 7.5.1 Conducted Emission Method ..................................................................................................... 13 7.5.2 Radiated Emission Method ........................................................................................................ 14 8 TEST SETUP PHOTO ............................................................................................................................ 33 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 33 Report No.: GTS202211000008F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 33 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass AC Power Line Conducted Emission 15.207 N/A Conducted Output Power 15.247 (b)(3) Pass Channel Bandwidth 15.247 (a)…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Model No.: LV30RM01A‐06 Radiated Emission

Contact Information

Applicant

zhiquan li(Manager)
[email protected]+86-0760-88868888Fax: +86-0760-88868888

Technical Contact

INTERNATIONAL DEVELOPMENT COMPANY
[email protected]

United States

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.42 GHz - 2.47 GHz140.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from INTERNATIONAL DEVELOPMENT COMPANY

Solar LED Light - FCC ID 2AP35-SR07PM04H41 - INTERNATIONAL DEVELOPMENT COMPANY
2AP35-SR07PM04H41

Solar LED Light

Jan 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Solar LED Light - FCC ID 2AP35-SR32SL02H-08 - INTERNATIONAL DEVELOPMENT COMPANY
2AP35-SR32SL02H-08

Solar LED Light

Dec 07, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Solar LED Light - FCC ID 2AP35-SR58FA01H-08 - INTERNATIONAL DEVELOPMENT COMPANY
2AP35-SR58FA01H-08

Solar LED Light

Dec 07, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LED Garage Light - FCC ID 2AP35-D303353 - INTERNATIONAL DEVELOPMENT COMPANY
2AP35-D303353

LED Garage Light

Nov 06, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
LOW VOLTAGE BLUETOOTH SPEAKER PATH ACCESSOR - FCC ID 2AP35-LV0BAA01H - INTERNATIONAL DEVELOPMENT COMPANY
2AP35-LV0BAA01H

LOW VOLTAGE BLUETOOTH SPEAKER PATH ACCESSOR

Sep 21, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter