2AQ7B-IP209Smart Outdoor Camera

Shenzhen Interthings Technology Co., Ltd.
Smart Outdoor Camera - FCC ID 2AQ7B-IP209 - Shenzhen Interthings Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 07, 2023
Application Purpose
Original Equipment
Date of Application
Nov 07, 2023
Equipment Note
Smart Outdoor Camera
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Interthings Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model: IPC209 420x128MM Type-C USB cable camerascrew package eset slot R SD Card Status light Microphone On/off DESCRIPTION: Power DC 5V +/- 5% Status lights: Blue light solid on: system setup Blue light blinking fast: waiting for the pairing Blue light blinking slowly: waiting for the WiFi connection Microphone Capture sound for your video SD Card slot Support local micro SD Card storage (Max. 128GB) Reset Press and hold the reset button for 5 seconds to reset the camera (if you have modied the settings, they will return to factory defaults) Before you start write down your network name & password. Note: this item only works on a 2.4GHz Wi-Fi network, not on a 5GHz network. Please consult your router manual for settings. Please follow the instructions and make sure the passwords are correctly inputted. One device can only be paired with one App account at a time, if the device has already been paired with another account, then it can’t be paired to another account. The device can be removed from the app account by being deleted from the app. The device will be reset automatically once the blue light changes to a solid on. FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum 20cm distance between the radiator and your body: Use only the supplied antenna. Out Lights PIR Sensor Lens

Attestation Statements

(Shenzhen Interthings Technology Co., Ltd.) (November 7, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AQ7B-IP209) [Shenzhen Interthings Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Rongli Sun (Shenzhen Interthings Technology Co., Ltd.) (November 7, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AQ7B-IP209) [Shenzhen Interthings Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Rongli Sun

Attestation Statements

Attestation Statements (November 8, 2023) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2AQ7B-IP209) (Shenzhen Interthings Technology Co., Ltd.), the undersigned, hereby authorize (MERKURY INNOVATIONS LLC) to act as our designated U.S. agent for service of process, (Shenzhen Interthings Technology Co., Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (MERKURY INNOVATIONS LLC) accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: Shenzhen Interthings Technology Co., Ltd. Contact Name: Rongli Sun Address: 701, Building 1, Lechuanghui Building, No.1211 Guanguang Road, Longhua District, Shenzhen, China Telephone No: 13538214502 Email: [email protected] FRN:0027836717 U.S. Agent Information: Company Name: MERKURY INNOVATIONS LLC Address: 39 Broadway Suite 1530 New York, NY 10006 United States Contact Name: Joan Blendowski Telephone No: (212) 840-8550 Email: [email protected] FRN: 0019755669 Applicant Signature: Agent Signature: Applicant printed name: Rongli Sun Agent printed name: Joan Blendowski

Cover Letter(s)

Shenzhen Interthings Technology Co., Ltd. Model Difference Data:November 7, 2023 Product description: Smart Outdoor Camera Model name: IPC209, GN-CW064-199, GN-CW264-199, GN-CW964-199 Trade Name: N/A FCC ID: 2AQ7B-IP209 All the model are the same circuit and RF module, except model names . Regards Sincerely Client’s signature : Client’s name / title : Rongli Sun(Account Manager) Contact information / address:701, Building 1, Lechuanghui Building, No.1211 Guanguang Road, Longhua District, Shenzhen, China

Cover Letter(s)

Shenzhen Interthings Technology Co., Ltd. (November 7, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Smart Outdoor Camera / IPC209, GN- CW064-199, GN-CW264-199, GN-CW964-199 / FCC ID: 2AQ7B-IP209) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Rongli Sun Title: Account Manager

Cover Letter(s)

Shenzhen Interthings Technology Co., Ltd. (November 7, 2023) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Rongli Sun Title: Account Manager

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: IPC209 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location:

Internal Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 7 Model: IPC209 Internal Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 6 of 7 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 7 of 7 ANT

RF Exposure Info

FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2AQ7B-IP209 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result 2.4G WIFI 802.11g&2 437 14±1 15 31.6228 1.5704 (1.96dBi) 0.0099 1 Pass

Test Report

TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Smart Outdoor Camera FCC ID: 2AQ7B-IP209 Trademark: N/A Model Number: IPC209, GN-CW064-199, GN-CW264-199, GN-CW964-199 Prepared For: Shenzhen Interthings Technology Co., Ltd. Address: 701, Building 1, Lechuanghui Building, No.1211 Guanguang Road, Longhua District, Shenzhen, China. Manufacturer: Shenzhen Interthings Technology Co., Ltd. Address: 701, Building 1, Lechuanghui Building, No.1211 Guanguang Road, Longhua District, Shenzhen, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Oct. 13, 2023 Sample tested Date: Oct. 13, 2023 to Oct. 18, 2023 Issue Date: Oct. 18, 2023 Report No.: CTB231018054RFX Test Standards FCC Part15.247 ANSI C63.10:2013 Test Results PASS Remark: This is WIFI-2.4GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB231018054RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 63 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 7 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 10 6.1 Block Diagram Of Test Setup ......................................................................................................... 10 6.2 Limit ................................................................................................................................................ 10 6.3 Test procedure ............................................................................................................................... 10 6.4 Test Result ..................................................................................................................................... 12 7. RADIATED SPURIOUS EMISSION ............................................................................................. 14 7.1 Block Diagram Of Test Setup ......................................................................................................... 14 7.2 Limit ................................................................................................................................................ 14 7.3 Test procedure ............................................................................................................................... 15 7.4 Test Result ..................................................................................................................................... 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 38 8.1 Block Diagram Of Test Setup ......................................................................................................... 38 8.2 Limit ................................................................................................................................................ 38 8.3 Test procedure ............................................................................................................................... 38 8.4 Test Result ..................................................................................................................................... 39 9. COUDUCTED OUTPUT POWER ................................................................................................. 46 9.1 Block Diagram Of Test Setup ..............................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: IPC209 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions

Contact Information

Applicant

Rongli Sun(Account Manager)
[email protected]86-755-21040734Fax: 86-755-21040734

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz30.61 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz and 40MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Shenzhen Interthings Technology Co., Ltd.

Digital Frame - FCC ID 2AQ7B-PF326 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-PF326

Digital Frame

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
Smart Two Way Security Camera - FCC ID 2AQ7B-IPC236 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPC236

Smart Two Way Security Camera

Aug 13, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2AQ7B-IPB217

Smart Doorbell

Aug 03, 2026

Equipment Class

DTS - Digital Transmission System
Smart Video Doorbell - FCC ID 2AQ7B-IPB239 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPB239

Smart Video Doorbell

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
Smart PTZ Camera - FCC ID 2AQ7B-IPC267 - Shenzhen Interthings Technology Co., Ltd.
2AQ7B-IPC267

Smart PTZ Camera

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System