FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensata Technologies/
  3. 2ATIMHTERX2

2ATIMHTERX2HTERX2

Sensata Technologies
HTERX2 - FCC ID 2ATIMHTERX2 - Sensata Technologies
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Jul 11, 2024
Application Purpose
Original Equipment
Date of Application
Jul 08, 2024
Equipment Note
HTERX2
Frequency Range
433.92000000 - 433.92000000
Company
Sensata Technologies
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

http://www.tpmseuroshop.com/documents/declaration_conformities Unit 11 Technology Park Belfast Road Antrim, Northern Ireland, BT41 1QS The device under test is manufactured by the grantee (Sensata) and sold as an OEM product. Per 47 CFR 2.909, 2.927, 2.931, 2.1033, 15.15(b) etc..., the grantee must ensure the end-user has all applicable / appropriate operating instructions. When end-user instructions are required, as in the case of this product, the grantee must notify the OEM to notify the end- user. Sensata will supply this document to the reseller/distributor dictating what must be included in the end user’s manual for the commercial product. INFORMATION TO BE INCLUDED IN THE END USER'S MANUAL The following information (in blue) must be included in the end product user’s manual to ensure continued FCC and Industry Canada regulatory compliance. The ID numbers must be included in the manual if the device label is not readily accessible to the end user. The compliance paragraphs below must be included in the user's manual. This device complies with Part 15 of the FCC Rules and with Licence exempt RSS standards of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. ****************************************************************************** FCC ID: 2ATIMHTERX2

Attestation Statements

Michael Maingot By: __________________________ ______ __________________ (Signature) (Print name) Title: ___________EMC+RF Approval Manager______________ Company: __Sensata Technologies Ltd____Telephone: ___02894482181_______________________ 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Sensata Technologies Ltd,Unit 10, Antrim Technology Park, Antrim, Co. Antrim, Northern Ireland, BT41 certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: N/A Statement for 47 CFR section 2.911(d)(5)(ii) Sensata Technologies Ltd,Unit 10, Antrim Technology Park, Antrim, Co. Antrim, Northern Ireland, BT41 (“the applicant”) certifies that, as of the date of the filing of this application, the applicant ☐ - is / ☐ - is not identified on the Covered List as an entity producing “covered” equipment. Thank you,

Attestation Statements

Certification designating a U.S. Agent for service of process: As required by section 2.911(d)(7), the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. In either scenario, the designation of the U.S. agent for service of process should be provided as an attachment to the equipment authorization application. The applicant must provide a written certification, which must: i. Be signed by both the applicant and designated agent for service of process, if the agent is different from the applicant. ii. Acknowledge the applicant’s consent and the designated agent’s obligation to accept service of process. iii. Provide a physical U.S. address and email for the designated agent. iv. Acknowledge the applicant’s acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Unofficial information provided by FCC personnel on February 14, 2023, via the monthly call with the TCB Council: The Agent for Process of Service:  cannot be a TCB or affiliated with a TCB (e.g. could not be a person who works for a TCB or a company that owns or is owned by the TCB)  cannot be a [FCC recognised] Lab or affiliated with a test lab (e.g. could not be a person who works for a Lab or a company that owns or is owned by the Lab)  Agent can be Individual Entity or a Company Entity  Agent Entity must be located in US, US address/phone  Entity acting as Agent must have FRN (best practice, put FRN on Agent Letter)  Agent letter does not have to be FCC ID specific, can be general Agent for Grantee For devices being marketed or for which marketing has ceased for less than 1 year, if the Agent for Process of Service changes, then for every TC Number the TCB must request the FCC to put application into Audit Mode and Agent Letter needs to be updated (superseded). NOTE: The U.S. Agent for Service of Process should not be confused with the authorized agent used for signing the 731 form, other cover letters within the application, and/or the agent who may interface with the TCB. U.S. Agent Designation for Service of Process ATTENTION: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA REGARDING: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Approve-IT, Inc. Contact Name: Nathan Grinager Street Address: 8011 34 th Ave South, Suite 342 City/Province/Zip: Bloomington, MN 55425 Telephone No: 651-247-1678 Email: [email protected] FRN #: 0027533835 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: May 30 th , 2023 Signed by (Printed Name/Title): Nathan Grinager / Co-President *This letter is valid indefinitely for all applications submitted within the period of 5/30/2023 – 5/30/2024. The Applicant confirms its explicit consent and acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Sensata Technologies Grantee Code: 2ATIM Contact Name:James Kyle Street Address:Unit 11, technology Park,Antrim,Co Antrim City/Province/Zip: BT41 1QS, UK Telephone No:02894483067 Email:[email protected] Applicant Signature: Date:29.5.2023 Signed by :James Kyle.RF Approval Co-ordinator

Cover Letter(s)

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Re: Certification for Sensata Technologies FCC ID: 2ATIMHTERX2 IC: RSS-GEN/CNR-GEN REQUEST FOR CONFIDENTIALITY Pursuant to USA FCC 47 CFR 0.457(d) and 0.459 and Canada IC RSP-100, Section 10, Sensata Technologies requests that a part of the subject application be held confidential. Sensata Technologies has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to ”competition” would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Exhibit Conf. TypeRational Exh 04 - Block DiagramPermanentIncludes proprietary internal oscillator frequency information. Exh 05 - SchematicsPermanentIncludes proprietary design information Exh 10 - BOM + PlacementPermanentIncludes proprietary design information Exh 12 - Description of Oper.PermanentIncludes proprietary design information Long Term Confidentiality (Permanent):Sensata Technologies requests that any exhibits listed above as permanently confidential be permanently withheld from public review. Wherein Long Term Confidentiality is not an option for specific exhibits with ISED, this request applies only to the FCC application for those exhibits. Short-Term Confidentiality (FCC Only):Sensata Technologies requests that any exhibits selected above as short term confidential be withheld from public view for a period of days (noted above) from the date of the Grant of Equipment Authorization and prior to marketing. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc. 9

Cover Letter(s)

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Attn.:Federal Communications Commission Equipment Approval Services P.O. Box 358315 Pittsburgh, PA 15251-5315 Re: Certification for Sensata Technologies HTERX2 FCC ID: 2ATIMHTERX2 If necessary, we have enclosed application materials for certification of Sensata Technologies HTERX2. It has been verified to comply with CFR Title 47, Part 15.109. Current Variants: There is only a single variant of the EUT. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc. 10

ID Label/Location Info

ID No. FORMAT DIGITS 1-5 PRODUCT CODE DIGITS 6-9 DAY CODE(1-366) ID:01849 XXXX XX XXXXX XX XX DIGITS 10-11 YEAR CODE(0-99) DIGITS 12-16 SERIAL NUMBER (RESET DAILY) DIGITS 19-20 CELL CODE DIGITS 17-18 LINE CODE(1-99) H G D A B C E F 23456789101112 ENG-F-045 ISS 05 1 A B C D E F G H 123456789 101112 FOR REFERENCE ONLY, CHECK LATEST REVISION BEFORE USE. REFER TO PLM FOR CONTROLLED DATA, CHANGE HISTORY AND APPROVALS TECHNOLOGY PARK, ANTRIM, UK, BT41 1QS MATERIAL THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY OF SCHRADER ELECTRONICS LIMITED. THE INFORMATION CONTAINED WITHIN IT MAY NOT BE USED, DISCLOSED OR REPRODUCED IN WHOLE OR PART, WITHOUT THE EXPRESSED WRITTEN CONSENT OF SCHRADER ELECTRONICS LIMITED. NO RIGHT IS GRANTED TO DISCLOSE OR USE ANY INFORMATION CONTAINED WITHIN THIS DRAWING. SCHRADER ELECTRONICS LIMITED IS PART OF THE SENSATA TECHNOLOGIES GROUP. PART NUMBER N/A70803115545 MASS (g)TITLE 49 GENERIC EXTERNAL RECEIVER 2.0 433 70803115545 LASER MARKING DRAWING PROJECT NO. PRJ0014241 REVISION SYMBOL INTERPRET DRAWING PER ASME Y14.5-2009 SEE NOTES FOR GENERAL TOLERANCES UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES DO NOT SCALE DRAWING THIRD ANGLE PROJECTION SIZEDRAWING NO.DRAWING REV. A20002121502 SCALE 2:1CATIA V5R28SHEET 1 OF 1 REVREVISION DESCRIPTIONBYECODATE 01INITIAL RELEASECLECO-57490518/OCT/2023 02 FCC APPROVAL UPDATED, TABLE 4 UPDATED TO REFERENCE CHANGE. CLECO-59323028/FEB/2024 02 02 02 TPMS - ECU 433.92 MHz DATE: YYMMDD M: HTERX2 PART NUMBER: 70803115545 ID: 01849XXXXXXXXXXXXXXX TABLE 1 MECH CODE01849 TABLE 2 BOM No. PART DESCRIPTION MECH CODE CUST. P/N (BOM) 90818115547 GENERIC EXTERNAL RECEIVER 2.0 433 70803115545 0184970803115545 TABLE 3 PRODUCTION LOCATION COUNTRY OF MANUFACTURE ANTRIMUK TABLE 4 PRODUCT MARKINGS ITEMDESCRIPTIONINFORMATIONFORMFONTSIZE REQUIRED (mm) 1FREQUENCYTPMS-ECU 433.92 MHz LASER ARIAL NARROW - BOLD1.5 2MANUFACTURER DATEDATE: YYMMDDARIAL NARROW - BOLD1.5 3MODEL NUMBERM: HTERX2ARIAL NARROW - BOLD1.5 4PART NUMBERPART NUMBER: 70803115545ARIAL NARROW - BOLD1.5 5ID NUMBERID: 01849XXXXXXXXXXXXXXXARRIAL NARROW - BOLD1.5 6USA RF APPROVALFCC ID:2ATIMHTERX2ARRIAL NARROW - BOLD1.5 72D MATRIXAS SHOWNN/A6.0 X 6.0 8MANUFACTURER LOGOSESATA TECHNOLOGIESN/A10(H) 9MEXICO RF APPROVALIFT:XXXXXXXXX-XXXXARRIAL NARROW - BOLD1.5 10CANADA RF APPROVALCAN RSS-Gen /CNR-Gen ARRIAL NARROW - BOLD1.5 11ECE RF APPROVAL E24 LOGON/A6mm MIN XXX-XX-XXXXARRIAL NARROW-BOLD3mm MIN 1 2 4 5 7 3 11 IFT:XXXXXXXXX-XXXX CAN RSS-Gen /CNR-Gen FCC ID:2ATIMHTERX2 8 9 10 6 XXX-XX-XXXX DRAFT E11

RF Exposure Info

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Drive Brighton, MI 48116 Phone: (734) 252-9785, Fax (734) 926-9785 e-mail:[email protected] RF EXPOSURE CALCULATIONS Summary: The EUT with all transmitters is compliant with both the FCC power density limit and the ISED Exposure Evaluation limits. Requirement: According to USA CFR 15 §1.1307 (b )(1 ), s ystems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. For Canada, RSS-102 sets out the requirements and measurement techniques used to evaluate radio frequency (RF) exposure compliance of radiocommunication apparatus designed to be used within the vicinity of the human body.

Test Report

Amber Helm Development L.C. 92723 Michigan Hwy-152 Sister Lakes, Michigan 49047 USA Tel: 888-847-8027 SENRX2-WR2404RX Issued:March 13, 2024 EMC Test Report regarding USA:CFR Title 47, Part 15.109(Emissions) Canada: ISED RSS-GEN (Verification)(Emissions) for HTERX2 Category: Receiver Judgments: Aligns with CFR 47 Part 15.109 Testing Completed: March 13, 2024 TESTING NVLAP LAB CODE 200129-0 Prepared for: Sensata Technologies Unit 11, Antrim Technology Park, Antrim Northern Ireland BT41 1QS United Kingdom Phone: +44 28 9448 2181, Fax: +44 28 9446 8440 Contact: Michael Maingot, [email protected] Data Rec./Rev. by: Rpt. Auth. by: John NantzDr. Joseph Brunett, EMC-002790-NE Rpt. Prep./Rev. by:Date of Issue:March 13, 2024 Dr. Joseph Brunett, EMC-002790-NE A copy of this report will remain on file until March 2034.Page 1 of 13 Date: March 13, 2024Prepared For: Sensata TechnologiesReport No.: SENRX2-WR2404RX Revision History Rev. No.DateDetailsRevised By r0March 13, 2024Initial Release.J. Brunett Contents Revision History2 Table of Contents2 1 Test Report Scope and Limitations4 1.1 Laboratory Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Report Retention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.3 Subcontracted Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.4 Test Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.5 Limitation of Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.6 Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.7 Endorsements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.8 Test Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.9 Traceability and Equipment Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2 Test Specifications and Procedures6 2.1 Test Specification and General Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3 Configuration and Identification of the Equipment Under Test7 3.1 Description and Declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3.1.1EUT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.2Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.3Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.4Test Samples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.5Functional Exerciser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.6Modifications Made . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.7Production Intent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.8Declared Exemptions and Additional Product Notes . . . . . . . . . . . . . . . . . . . . . . . .8 4 Emissions9 4.1 General Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.1.1Radiated Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.1.2Conducted Emissions Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.1.3Power Supply Variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.2 Unintentional Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.2.1Radiated Receiver Spurious . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5 Measurement Uncertainty and Accreditation Documents13 Amber Helm Development L.C.Page 2 of 13 Date: March 13, 2024Prepared For: Sensata TechnologiesReport No.: SENRX2-WR2404RX List of Tables 1.8.0 Test Site List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.9.0 Equipment List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1.0 EUT Declarations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4.2.1 Receiver Chain Spurious Emissions≥30 MHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5.0.0 Measurement Uncertainty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 List of Figures 3.1.0 Photos of EUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3.1.1 EUT Test Configuration Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 4.1.1 Radiated Emissions Diagram of the EUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.1.1 Radiated Emissions Test Setup Photograph(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.0.0 Accreditation Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Amber Helm Development L.C.Page 3 of 13 Date: March 13, 2024Prepared For: Sensata TechnologiesReport No.: SENRX2-WR2404RX 1 Test Report Scope and Limitations 1.1 Laboratory Authorization Test Facility description and attenuation characteristics are on file with the FCC Laboratory, Columbia, Maryland (FCC Reg. No: US5348 and US5356) and with ISED Canada, Ottawa, ON (File Ref. No: 3161A and 24249). Amber Helm Development L.C. holds accreditation under NVLAP Lab Code 200129-0. 1.2 Report Retention For equipment verified to comply with the regulations herein, the manuf…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Maingot(EMC & Type Approval Manager)
[email protected]44 (0) 28 9448 2181Fax: N/A

Technical Contact

Willow Run (WR) Test Labs, Inc.Joseph D Brunett
[email protected]7342529785

7117 Fieldcrest Dr · Brighton · United States

Non-Technical Contact

Willow Run (WR) Test Labs, Inc.Joseph D Brunett
[email protected]7342529785

Test Firm

AHD (Amber Helm Development, L.C.)Gordon Helm
[email protected]269-429-8352Fax: 269-429-9016

Technical Specifications

#Rule PartsFrequency RangePower Output
115B433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Sensata Technologies

Tyre Pressure Monitoring Sensor - FCC ID 2ATIMATFPG3 - Sensata Technologies
2ATIMATFPG3

Tyre Pressure Monitoring Sensor

Oct 02, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
BLE Transmitter - FCC ID 2ATIMBREX - Sensata Technologies
2ATIMBREX

BLE Transmitter

Nov 21, 2022

Equipment Class

DTS - Digital Transmission System
Range Extender - FCC ID 2ATIMREX - Sensata Technologies
2ATIMREX

Range Extender

Apr 20, 2021

Equipment Class

DTS - Digital Transmission System
Wireless Gateway - FCC ID 2ATIMHUBA - Sensata Technologies
2ATIMHUBA

Wireless Gateway

Apr 19, 2021

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter