Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INSTALLATIONINSTRUCTIONS ♦INSTALLATION 1.TurnPowerOff.Indooruseonly. 2.Connectthedimmerswitchasshowninthewiringdiagram:Blackleadtohotwire,whiteleadtoneutral wire,Blackleadtoloadwire,greenleadtogroundwire. ♦MULTIGANGINSTALLATION Wheninstallingmorethanonecontrolinthesamewallbox,itmaybenecessarytoremovethe sidetabsbeforeinstalling(seebelow).Usingpliers,bendeachtabbackandforthuntilthey breakoff.Repeatforeachtabtoberemoved.RemovaloftabsWILLREDUCEMAXIMUM LOADCAPACITY. Thisapplicationguideappliestothefollowingproducts. (Notes:**meansthecolorcode:WH(white)/LA(lightalmond)/BK(black) 01- -02 - LEDindicatorResetButton AirGapSwitch -03- SQR22101**Z Z -wave 600WDIMMERSINGLE POLE FCCID:2AUCU-22601W IC:25381-22601W CANICES-3(B)/NMB-3(B) 2.1SinglePolewiring 2.23-waywiring Notes:L1,L2areinoroutterminalof3waymechanicalswitch(SQR14131XXorSQR14231XX)COMis commonterminal. ♦SPECIFICATIONS Voltage .................................................................................................................................................... 120VAC,60Hz Incandescent ................................................................................................................................................................ 600W DimmableLED............................................................................................................1.25A(150W) OperatingTemperature...............................................................................32°F〜104°F(0°C〜40°C) WireStripLength.....................................................................................................16mm(5/8in.) SupplyConnection..................................................................14AWGwires,suitableforatleast75°C ScrewTorque..................................................................................................................9-12Ib-in WirelessType.........................................................................................................................Z-WAVE WirelessFrequency...........................................................................................908.42MHz TabsRemovedforMulitganginstallation LoadType Maximumload rating(W) DeratingforMultiple 2gang(W) DeratingforMultiple ≥3gang(W) Incandescentlamp600W500W400W DimmableLED 150W150W150W ♦FEATURES WhenusingtheDimmertocontrolLEDlightsinconjunctionwithanotherDimmerto controlIncandescent/HalogenlightsfollowthisDeratingChartforMaximumCapacityon EACHdevice. •PerfectReplacementforregularwallON/OFF&Dimswitch,120VAC •ManualandRemoteON/OFF&Dimcontrolofanypermanentlyinstalledincandescent,dimmableLEDfixture •Presetlightleveloptionallowsthedimmerwillturnontothelightlevelthatitwasadjustedtotheprevioustime whenthelightwason •Canbeusedforsinglepoleor3-Way(Multi-location)withWF3KAuxiliarySwitch(soldseparately) •Air-GapSwitchfeaturemeetsULrequirementanddisconnectpowerfromloadlocally. ♦DESCRIPTION ThisSQR22601**WDimmerSwitchisaperfectwirelessmanualandremoteon/off/dimbrightcontrolreplacement ofregularon/offanddimmerswitch,controllingincandescent,dimmableLED.SlidingAir-Gapswitchtoatotally disconnectpowerwhilereplacinglightbulbsandpreventingfromleakagecurrentfromthefixture(s).Thisdimmer workswith3-WayAuxiliarySwitchthatreducingenergyconsumption,enhancingthevalueoftechnologyofyour home,condominiumsandapartment.TheLEDdimmingperformancemayvarybasedupondimmertype,model, manufacturer,circuitwiringandcircuitloading.Nospecificrecommendationonproductselectionandthereareno warrantiesofperformanceorcompatibilityimplied. WARNING:CALIFORNIAPROPOSITION65 ThisproductcanexposeyoutochemicalsincludingCarbonblack,whichisknowntotheStateof Californiatocausecancer,andBisphenolA(BPA),whichisknowntotheStateofCaliforniato causebirthdefectsorotherreproductiveharm.Formoreinformationgoto www.P65Warnings.ca.gov AirGapSwitch Duringnormaloperation,thereisasmallamountofpowerpassingthroughtheswitchtotheloadevenwhenthe dimmerswitchisturnedoff.Thisdimmerhasanairgapswitchonthelowerrightsidetocompletelydisconnect powertotheload.Slidetheairgapswitchtolefttodisconnectthepowerwhilereplacinglightbulbsandslideitto rightfornormaloperation.Theairgapswitchmustbeallthewayinforthedimmertofunctionandcontrolthe lighting. Ifthecombined WattageofALL LED/bulbson1 dimmeris: ThentheMaximumCOMBINEDWattagedforthe Incandescent/bulbsonEACHattacheddimmer: IfNOTabsare removedthen MaxWattageis : If1sideofTabsare removedthenMax Wattageis: If2sidesofTabs areremovedthen MaxWattageis: OW600W500W400W 1-25W500W400W300W 26-50W400W300W200W 51-75W300W200W100W 76-100W200W100W50W 101-125W100W50WOW 126-150WOWOWOW 3.Checkconnectionstobesuretheyaretightandnobareconductorsareexposed. 4.Insertthisdimmerswitchintothestandardoutletboxcarefully. 5.Makesurethisdimmerswitchtotheboxusingthesuppliedscrews. Installthewallplate (notincluded)inthebelowfigure. ScrewVISAMutli-gang Screwless 6.Restorepoweratthecircuitbreakerandtestthesystem. IfyouareusingONLYLEDbulbsonALLDimmers,DONOTUSEthisDeratingChart. FollowtheLEDDeratingChart. ♦OPERATIONS DimmerSwitchPaddle HAZARDOFELECTRICSHOCK,EXPLOSION,ORARCFLASH •Thisequipmentmustonlybeinstalledandservicedbyqualifiedelectrical personnel. •Turnoffallpowersupplyingthisequipmentbeforeworkingonorinsideequipment. •Alwaysuseaproperlyratedvoltagesensingdevicetoconfirmpowerisoff. •Replacealldevices,doors,andcoversbeforeturningonpowertothisequipment. •ToReducetheRiskofOverheatingandPossibleDamagetoOtherEquipment,Do NotInstalltoControlaReceptacle,aMotor-OperatedApplianceoraFluorescent LightingFixtureoraTransformerSuppliedAppliance. •UsewithCopperwireonly •Indooruseonly. Failuretofollowtheseinstructionswillresultindeathorseriousinjury. -04- -05- Aug,2019 -06- ♦ FCCCOMPLIANCESTATEMENT FederalCommunicationCommissionInterferenceStatement TheequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassB DigitalDevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedto providereasonableprotectionagainstharmfulinterferenceinaresidential installation.Thisequipmentuses,generatesandcanradiateradiofrequ…
Text truncated - open the document above for the full version.
Date:04/17/2018VCB_F-01:OperatingProceduresForm–FCCConfidentialityv02Page1of1 SchneiderElectric(China)Co.,Ltd.,ShenzhenBranch FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2AUCU-22101Z PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequest confidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName 1.BlockDiagram, 2.Schematics, 3.OperationalDescription 1.2AUCU-22101Z-Blockdiagram 2.2AUCU-22101Z-SCH 3.2AUCU-22101Z-Operationaldescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsmaybeharmfultothe applicantandprovideunjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateofthe Grantforthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealso requesttemporaryconfidentialtreatmentofinformationaccompanyingthisapplication asoutlinedbelowforaninitialperiodofxxxx(ie-“45”,“90”or“180”)days: ExhibitTypeFileName N/AN/A Signature: Contactname:TonyHuang Companyname:SchneiderElectric(China)Co.,Ltd.,ShenzhenBranch Address:Room201,BuildingA,No.1QianwanyiRoad,ShengangCooperationZone,Qianhai, Shenzhen,China
Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Authorization v02 Page 1 of 2 Schneider Electric (China) Co., Ltd., Shenzhen Branch Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2020/3/16 SUBJECT: FCC Application for (FCC ID: 2AUCU-22101Z) To Whom It May Concern: We, the undersigned, hereby authorize Aaron Ma in Shenzhen Huaxia Testing Technology Co., Ltd at 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Shenzhen Huaxia Testing Technology Co., Ltd on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Authorization v02 Page 2 of 2 (Must be signed by the person that is listed on the FCC Website) Signature: Contact name: Tony Huang Company name: Schneider Electric (China) Co., Ltd., Shenzhen Branch Address: Room 201, Building A, No. 1 Qianwanyi Road, Shengang Cooperation Zone, Qianhai, Shenzhen, China
FCC ID:2AUCU-22101Z FCC ID:2AUCU-22101Z FCC ID:2AUCU-22101Z
Original format A4 A B C D E F A B C D E F 1 2 34 State: 00 1/1 Document Number: Doc. Rev. Sheet: 1.000 mm Scale: Technical Specification: Units of measure : The information is highly confidential and is the exclusive property of Schneider Electric copyright reserved. This drawing must not be used for any purpose other than that expressly permitted in writing by the owners and must not be disclosed or reproduced in any way without permission from the owners in writing. This drawing must be returned to the owners when the purpose has ceased. Provisional NOTES: *** ARTWORK IS THE MASTER FOR COLOUR, FONT, SIZE & LOGO'S*** 1. TEST FOR MARKINGS: REFER TO CQCS 2. LOCATION OF MARKING: POSITION AS SHOWN 3. FONT: ARIAL ROUNDED 4. TEXT HEIGHT: AS INDICATED Commercial Reference Color White SQR22101**Z 5. SQUARE D LOGO SIZE: 2.73MM(H)*13.79MM(L) Light Almond Black } See the table 120VAC,60Hz 600W INC 1.25A 150W LED TOP YYYYMMDD 0.157 inch (4 mm) 0.094 inch (2.4 mm) 1/2 inch 0.5 inch (12.7mm) (Pantone Cool grey 6C) INDOOR USE ONLY LOAD TRAVELER For supply connector, use wires rated for at least 75°C FCC ID: 2AUCU-22101Z IC: 25381-22101Z 1/2 inch STRIP GAUGE EXXXXXX Made in China HOT NEUTRAL 6. MINIMUM SIZE: GDE6614905 (11mm) 7. MINIMUM SIZE:
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V04 Repor tTemplate Revision Date: 2018-07-06 RF Exposure Evaluation Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No. : CQASZ20200300140E-02 Applicant: Schneider Electric (China) Co., Ltd., Shenzhen Branch Address of Applicant: Room 201, Building A, No. 1 Qianwanyi Road, Shengang Cooperation Zone, Qianhai, Shenzhen, China Equipment Under Test (EUT): EUT Name: Z-wave dimmer Model No.: SQR22101WHZ, SQR22101LAZ, SQR22101BKZ Test Model No.: SQR22101WHZ Brand Name: Schneider Electric, Square D FCC ID: 2AUCU-22101Z Standards: 47 CFR Part 1.1307 47 CFR Part 1.1310 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-03-12 Date of Test: 2020-03-12 to 2020-06-04 Date of Issue: 2020-06-04 Test Result :PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: (Tom Chen) Reviewed By: (Aaron Ma ) Approved By: ( Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-02 Page: 2 of 6 1Version Revision History Of Report ReportNo.Version Description Issue Date CQASZ20200300140E-02Rev.01 Initial report 2020-06-04 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-02 Page: 3 of 6 2 Contents Page 1 VERSION......................................................................................................................................................................2 2CONTENTS..................................................................................................................................................................3 3 GENERAL INFORMATION........................................................................................................................................4 3.1 C LIENTINFORMATION................................................................................................................................................4 3.2 G ENERALDESCRIPTION OFEUT................................................................................................................................4 4 SAR EVALUATION.....................................................................................................................................................5 4.1 RF E XPOSURECOMPLIANCEREQUIREMENT..............................................................................................................5 4.1.1 Standard Requirement..................................................................................................................................5 4.1.2 Limits................................................................................................................................................................5 4.1.3 EUT RF Exposure..........................................................................................................................................6 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-02 Page: 4 of 6 3 General Information 3.1 Client Information Applicant: Schneider Electric (China)Co., Ltd., Shenzhen Branch Address of Applicant: Room 201, Building A, No. 1 Qianwanyi Road, Shengang Cooperation Zone, Qianhai, Shenzhen, China Manufacturer: Schneider Electric (China)Co., Ltd., Shenzhen Branch Address of Manufacturer: Room 201, Building A, No. 1 Qianwanyi Road, Shengang Cooperation Zone, Qianhai, Shenzhen, China 3.2 General Description of EUT Product Name: Z-wave dimmer Model No.: SQR22101WHZ, SQR22101LAZ, SQR22101BKZ Test Model No.: SQR22101WHZ Trade Mark: Schneider Electric, Square D Hardware Version: DC-HW01/AC-HW01 Software Version: V1.08 Frequency Range: 908.4MHz ~ 916MHz Modulation Type:GFSK Number of Channels:3 (declared by the client) Sample Type: MobilePortableFix Location Test Software of EUT:RF test (manufacturer declare ) Antenna Type: External antenna Antenna Gain: 0dBi Power Supply: 120V 60Hz Note: Model: SQR22101WHZ, SQR22101LAZ, SQR22101BKZ Only the model SQR22101WHZ was tested, since the electrical circuit design, layout, components used and internal wiring were identical for the above models, with difference being color of appearance. Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-02 Page: 5 of 6 4 SAR Evaluation 4.1RF Exposure Compliance Requirement 4.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 4.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]≤3.0 for 1-g SAR and≤7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-02 Page: 6 of 6 4…
Text truncated - open the document above for the full version.
Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building,Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 FCC Test Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No. : CQASZ20200300140E-01 Applicant: Schneider Electric (China) Co., Ltd., Shenzhen Branch Address of Applicant: Room 201, Building A, No. 1 Qianwanyi Road, Shengang Cooperation Zone, Qianhai, Shenzhen, China Equipment Under Test (EUT): EUT Name: Z-wave dimmer Model No.: SQR22101WHZ, SQR22101LAZ, SQR22101BKZ Test Model No.: SQR22101WHZ Brand Name: Schneider Electric, Square D FCC ID: 2AUCU-22101Z Standards: 47 CFR Part 15, Subpart C Date of Receipt: 2020-03-12 Date of Test: 2020-03-12 to 2020-06-04 Date of Issue: 2020-06-04 Test Result :PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: (Tom Chen) Reviewed By: (Aaron Ma ) Approved By: ( Jack Ai) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-01 Page: 2 of 33 1 Version Revision History Of Report ReportNo.Version Description Issue Date CQASZ20200300140E-01Rev.01 Initial report 2020-06-04 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-01 Page: 3 of 33 2 Test Summary Test ItemTest RequirementTest methodResult Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203 ANSI C63.10 (2013)PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 (2013)PASS Field Strength of the Fundamental Signal 47 CFR Part 15, Subpart C Section 15.249 (a) ANSI C63.10 (2013)PASS Spurious Emissions 47 CFR Part 15, Subpart C Section 15.249 (a)/15.209 ANSI C63.10 (2013)PASS Restricted bands around fundamental frequency (Radiated Emission) 47 CFR Part 15, Subpart C Section 15.249(a)/15.205 ANSI C63.10 (2013)PASS 20dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.215 (c) ANSI C63.10 (2013)PASS Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200300140E-01 Page: 4 of 33 3 Contents Page 1 VERSION....................................................................................................................................................................2 2 TEST SUMMARY......................................................................................................................................................3 3CONTENTS................................................................................................................................................................4 4 GENERAL INFORMATION.....................................................................................................................................5 4.1 C LIENTINFORMATION..............................................................................................................................................5 4.2 G ENERALDESCRIPTION OFEUT.............................................................................................................................5 4.3 T ESTENVIRONMENT ANDMODE.............................................................................................................................7 4.4 D ESCRIPTION OFSUPPORTUNITS............................................................................................................................ 7 4.5 S TATEMENT OF THE MEASUREMENT UNCERTAINTY................................................................................................ 8 4.6 T ESTLOCATION....................................................................................................................................................... 9 4.7 T ESTFACILITY.........................................................................................................................................................9 4.8 D EVIATION FROMSTANDARDS................................................................................................................................9 4.9 A BNORMALITIES FROMSTANDARDCONDITIONS.................................................................................................... 9 4.10 O THERINFORMATIONREQUESTED BY THECUSTOMER......................................................................................9 4.11 E QUIPMENTLIST...............................................................................................................................................10 5 TEST RESULTS AND MEASUREMENT DATA............................................................................................... 11 5.1 A NTENNAREQUIREMENT.......................................................................................................................................11 5.2 C ONDUCTEDEMISSIONS........................................................................................................................................ 12 5.3 R ADIATEDEMISSION..............................................................................................................................................16 5.4 20 DBBANDWIDTH.................................................................................................................................................22 6 PHOTOGRAPHS.....................................................................................................................................................25 6.1 R ADIATEDEMISSIONTESTSETUP......................................................................................................................... 25 6.2 C ONDUCTEDEMISSION....................................................................................................................................…
Text truncated - open the document above for the full version.
FCC ID:2AUCU-22101Z 1.1 Radiated Emission Test Setup 9KHz~30MHz 30MHz~1GHz: FCC ID:2AUCU-22101Z Above 1GHz: 1.2Conducted Emission
1F Block A of Tongsheng Technology Bldg, Huahui Rd · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.4 MHz - 916 MHz | - |

Z-WAVE+ 15A TR RECEPTACLE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Z-WAVE+ 600W DIMMER SINGLE POLE
Equipment Class
JAB - Part 15 Class B Digital Device
Z-WAVE+ 15A PLUG-IN OUTLET
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WI-FI 15A TR RECEPTACLE
Equipment Class
DTS - Digital Transmission System
WI-FI 600W DIMMER SINGLE POLE
Equipment Class
DTS - Digital Transmission System