Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MobileLabelPrinter HM-A300Q USERMANUAL Rev.1.0 XiamenHaninElectronicTechnologyCo.,Ltd. Address:Room305A,AngyeBuilding,PioneeringPark,TorchHigh-tech,Zone,Xiamen E-mail:[email protected] Web:www.hprt.com CautionSymbol Nevertouchthethermalheadimmediatelyaftertheprinterhasbeenused.Letthethermal headcoolforafewminutesbeforetouchingit. Thissymbolisindicatethatitiseasilydamaged.Observetheprecautionsforhandling electrostaticsensitivedevices. SafetyPrecautions Tousethisproductinsafety,pleasefollowtheprecautionsgivenbelow. WARNING Ifyounoticesmoke,astrangesmell,orastrangesound,turnoffthepowerimmediately,and removetheUSBcableand/orbatterypack.Thencontactthedealer. Ifanyforeignmaterial(metalscraps,water,orotherfluid)enterstheprinter,immediatelyturnoff theprinterandremovetheUSBcableand/orbatterypack.Then,contactyourdealerforadvice. Continueduseoftheprintercouldresultinafire. Neverattempttorepairtheprinteryourself.Alsodonotdisassembleormodifytheproduct.Doing socouldleadtoinjury,fire,orelectricshock. Donottouchthetearbar. Thereisatearbarinsidethepaperoutletslot.Neitherputyourhandinthepaperoutletslot whileprintingisinprogress,orputyourhandintotheoutletevenwhenprintingisnotinprogress. Theprintercovercanbeopenedwhenreplacingthepaper.However,sincethetearbarisonthe insideoftheprintercover,becarefulnottoplaceyourfaceorhandstooclosetothetearbar. Duringandimmediatelyafterprinting,theareaaroundthethermalheadisveryhot.Donottouchit, asyoucouldbeburned. Ifanybatteryfluidgetsonyourskinorclothing,immediatelywashtheaffectedareawithfresh water.Otherwise,skindamagemayresult. Thebatterypackmaybehotimmediatelyaftertheproducthasbeenused. Pleasebesuretoread UsingthePrinter Somesemiconductorscanbedamagedbystaticelectricity.Besuretoturnofftheprinterwhen insertingorremovingthebatterypack. Donotdroptheprinterorhititagainstahardobject. Donotopentheprintercoverwhiletheprinterisprinting. Beforeyouopentheprintercover,makesurethatprintingdataisnotbeingsenttotheprinter. DonotunplugorpluginaUSBcablewhiletheprinterisprintingorduringcommunication. DonottouchaUSBconnectorwhiletheprinterisprinting. Turnofftheprinterwhenyouarenotusingit. Whentheprinterisusedinalowtemperatureenvironment,thebattery'sperformancewillbe diminished,andtheamountoftimethatyoucanusetheprinterformaybereduced. Donotpulloutpaperwhiletheprintercoverisclosed. TheheatingelementandthedriverICofthethermalheadareeasilydamaged.Donottouchthem withmetalobjects,sandpaper,etc. Printingqualitymaysufferifthethermalheadheatingelementbecomessoiledbybeingtouched withyourhands.Donottouchthethermalheadheatingelement. ThereisariskofdamagetothedriverICofthethermalheadfromstaticelectricity.Neverdirectly touchtheIC. Donotoperatetheprinterifthereismoistureonthefrontsurfaceoftheheadfromcondensation, etc. ThermalPaperHandling Onlyusethermalpaperwiththedesignatedspecifications.Theprintingqualityandworkinglifeof thethermalheadcannotbeguaranteedifanypaperotherthanthatrecommendedisused.In particular,ifionconcentrationof[Na+,K+,Cl-]ishigh,itmaydrasticallyreducetheworkinglifeof thethermalhead.Pleaseexercisecaution. Storethethermalpaperinacool,dry,darklocation. Donotrubthethermalpaperwithahardobject. Donotleavethethermalpaperincontactwithplasticfilm,aneraser,oradhesivetapeforalong periodoftime. Donotstackthethermalpaperonfreshdiazocopiesorwet-typecopies. Donotusechemicalglueonthethermalpaper. Donotusethermalpaperthathasbeenstoredforalongperiod. OperatingEnvironmentforthePrinter Beforeactuallyunpackingtheprinter,rememberthefollowingpointswhendoingthis. Donotusetheprinterinanenvironmentinwhichitwillbesubjecttostrongshakingwhileitis printing. Becarefultoensurethattheprinterisnotexposedtodirectsunlight. Theappropriateenvironmentforusingtheprinterisdescribedbelow. Temperature:-10°Cto52°C Humidity:10%RHto85%RH(nocondensation) Donotplacetheprinternearacopyingmachineorotherdevicethatproducesastrong electromagneticfield. Keeptheprintersufficientlyremovedfromheatersandothersourcesofheat. Usetheprinterinaclean,low-humidityenvironmentthatisfreefromdust. Avoidusingtheprinterinhigh-humidityrooms. PrinterMaintenance Pleaseperformthefollowingmaintenanceevery6months. Thermalhead Dipacottonswabinanalcoholsolvent(ethanol,methanol,orisopropylalcohol),andcleanthe heatingareaofthehead. Platen Whileturningtheplaten,useasoftdryclothtolightlyrubtheentiresurfaceoftheplatenand removeanyforeignobjects. Paperstorageunitandthesurroundingarea Removeanydirt,dust,piecesofpaper,etc.,fromthepaperstorageunit. Contents 1.ProductOverview ....................................................................................................................................... 1 1.1Printer&Accessories ....................................................................................................................... 2 1.2AppearanceandComponents .......................................................................................................... 3 2.Setup ........................................................................................................................................................... 4 2.1BatteryPack ...................................................................................................................................... 4 2.1.1InsertingintothePrinter ....................................................................................................... 4 2.1.2ChargingtheBattery ............................................................................................................. 5 2.2Bluetooth .......................................................................................................................................... 8 2.3LoadingPaper ................................................................................................................................... 9 2.4MenuSettings ................................................................................................................................ 11 3.PrinterFeatures .......…
Text truncated - open the document above for the full version.
Xiamen Hanin Electronic Technology Co., Ltd. Model difference statement Product Name: Mobile Label Printer Model N o.: HM-A300Q, HM-Z3, HX-800, HM-A300, Q3, Q3PLUS, F35, M35, KM-300BU, HM-A310, HM-A320, HM-A330, HM-A350, HM-A360, HM-A380, HM-A388, HM-A390, BMA3, BMAU31, BMAU32, BMAU33, BMAU34, BMAU35, BMAX31, BMAX32, BMAX33, BMAX34,BMAX35, HM-A316, HM-A318, HM-A326, HM-A328, HM-A358,HM-A366, HM- A368, HM-A398, MA31, HM-Q3, MA31Q, iMOVE 3, HM-A300C We (Xiamen Hanin Electronic Technology Co., Ltd. Room 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen) hereby state that all the models are the same circuit and RF module, except the model name and appearance of the color Signature: Name / title: Qinqin Yu / Certified Engineer Tel: 15705965171 Email: [email protected] Date: 6.24.2021
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Xiamen Hanin Electronic Technology Co., Ltd. Address: Room 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen Product Name: Mobile Label Printer Model Number: HM-A300Q, HM-Z3, HX-800, HM-A300, Q3, Q3PLUS, F35, M35, KM-300BU, HM-A310, HM-A320, HM-A330, HM-A350, HM-A360, HM- A380,HM-A388, HM-A390, BMA3, BMAU31, BMAU32, BMAU33, BMAU34, BMAU35, BMAX31, BMAX32, BMAX33, BMAX34,BMAX35, HM-A316, HM- A318, HM-A326, HM-A328, HM-A358,HM-A366, HM-A368, HM-A398, MA31, HM-Q3, MA31Q, iMOVE 3, HM-A300C FCC Identifier: 2AUTE-A300Q We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Qinqin Yu Date: 7/1/2021 Title: Certified Engineer Signature of applicant:
C5266091_X10_Ed.2 1/1 Xiamen Hanin Electronic Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 7/1/2021 Subject: Request for Confidentiality FCC ID: 2AUTE-A300Q To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Qinqin Yu Title: Certified Engineer
1 - Page 1 of 5 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] APPENDIX 1- EUT PHOTO Photo 1 (For model HM-A300Q) Photo 2 1 - Page 2 of 5 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 1 - Page 3 of 5 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5 Photo 6 1 - Page 4 of 5 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 7 Photo 8 1 - Page 5 of 5 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 9
1 - Page 1 of 4 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] APPENDIX 1- EUT PHOTO Photo 1 (For model HM-A300Q) Photo 2 1 - Page 2 of 4 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 1 - Page 3 of 4 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5 Photo 6 1 - Page 4 of 4 - Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 7 Photo 8 PCB antenna
Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi210122025-01E3 Date of issue: June 16, 2021 Applicant: Xiamen Hanin Electronic Technology Co.,Ltd. Product name: Mobile Label Printer Model(s): HM-A300Q FCC ID: 2AUTE-A300Q Series model: Please refer to the remark Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 7- Report No.: MTi210122025-01E3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Series model Remark: HM-Z3, HX-800, HM-A300, Q3, Q3PLUS, F35, M35, KM-300BU,HM-A310, HM- A320, HM-A330, HM-A350, HM-A360, HM-A380,HM-A388, HM-A390, BMA3, BMAU31, BMAU32, BMAU33, BMAU34, BMAU35, BMAX31, BMAX32, BMAX33, BMAX34,BMAX35, HM-A316, HM-A318, HM-A326, HM-A328, HM- A358,HM-A366, HM-A368, HM-A398, MA31, HM-Q3, MA31Q, iMOVE 3, HM- A300C - Page 3 of 7- Report No.: MTi210122025-01E3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 4 of 7- Report No.: MTi210122025-01E3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] TEST RESULT CERTIFICATION Applicant’s name .................... : Xiamen Hanin Electronic Technology Co.,Ltd. Address .................................. : Room 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen Manufacturer's Name ............. : Xiamen Hanin Electronic Technology Co.,Ltd. Address .................................. : Room 305A, Angye Building, Pioneering Park, Torch High-tech, Zone, Xiamen Product description Product name ........................... : Mobile Label Printer Trademark ............................. : HPRT, iDPRT Model Name .......................... : HM-A300Q Serial Model ............................ HM-Z3, HX-800, HM-A300, Q3, Q3PLUS, F35, M35, KM- 300BU,HM-A310, HM-A320, HM-A330, HM-A350, HM-A360, HM- A380,HM-A388, HM-A390, BMA3, BMAU31, BMAU32, BMAU33, BMAU34, BMAU35, BMAX31, BMAX32, BMAX33, BMAX34,BMAX35, HM-A316, HM-A318, HM-A326, HM-A328, HM- A358,HM-A366, HM-A368, HM-A398, MA31, HM-Q3, MA31Q, iMOVE 3, HM-A300C Standards ............................... : N/A Test procedure ....................... : KDB 447498 D01 v06 Date of Test Date (s) of performance of tests ............ : Jan. 28, 2021 ~Mar. 05, 2021 Test Result ............................................. : Pass This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Testing Engineer : (Danny Xu) Technical Manager : (Leo Su) Authorized Signatory : (Tom Xue) - Page 5 of 7- Report No.: MTi210122025-01E3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................................................ 6 2. SAR TEST EXCLUCSION THRESHOLDS ........................................................................................................................ 7 - Page 6 of 7- Report No.: MTi210122025-01E3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing…
Text truncated - open the document above for the full version.
Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi210122025-01E1 Date of issue: June 16, 2021 Applicant: Xiamen Hanin Electronic Technology Co.,Ltd. Product name: Mobile Label Printer Model(s): HM-A300Q FCC ID: 2AUTE-A300Q Series model: Please refer to the remark Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 47 - Report No.: MTi210122025-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Series model Remark: HM-Z3, HX-800, HM-A300, Q3, Q3PLUS, F35, M35, KM-300BU,HM-A310, HM-A320, HM-A330, HM-A350, HM-A360, HM-A380,HM-A388, HM-A390, BMA3, BMAU31, BMAU32, BMAU33, BMAU34, BMAU35, BMAX31, BMAX32, BMAX33, BMAX34,BMAX35, HM-A316, HM-A318, HM-A326, HM-A328, HM-A358,HM-A366, HM-A368, HM-A398, MA31, HM-Q3, MA31Q, iMOVE 3, HM-A300C - Page 3 of 47 - Report No.: MTi210122025-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 4 of 47 - Report No.: MTi210122025-01E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Table of Contents 1. GENERAL INFORM AT I O N ................................................................................................................................... 7 1.1. DESCRIPTION OF EUT ................................................................................................................................................... 7 1.2. OPERATION CHANNEL LIST .............................................................................................................................................. 7 1.3. TEST CHANNEL LIST ....................................................................................................................................................... 8 1.4. ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 8 1.5. DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 8 2. SUMMARY OF TEST RESULT S .......................................................................................................................... 9 3. TEST FACILITIES AND ACCREDITATIONS .................................................................................................... 10 3.1. TEST LABORATORY ...................................................................................................................................................... 10 3.2. ENVIRONMENTAL CONDITIONS ...................................................................................................................................... 10 3.3. MEASUREMENT UNCERTAINTY ...................................................................................................................................... 10 3.4. TEST SOFTWARE ......................................................................................................................................................... 10 4. EQUIPMENT LIST ............................................................................................................................................... 11 5. TEST RESULT ..................................................................................................................................................... 12 5.1. ANTENNA REQUIREMENT ............................................................................................................................................. 12 5.1.1 Standard Requirement ...................................................................................................................................... 12 5.1.2 EUT Antenna ..................................................................................................................................................... 12 5.2. PEAK OUTPUT POWER TEST ......................................................................................................................................... 13 5.2.1 Limit .................................................................................................................................................................. 13 5.2.2 Test setup .......................................................................................................................................................... 13 5.2.3 Test Procedure ................................................................................................................................................... 13 5.2.4 Te s t Results ........................................................................................................................................................ 13 5.3. CONDUCTED EMISSION .....................................…
Text truncated - open the document above for the full version.
Model: HM-A300Q Radiated emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.60 mW |

Portable Photo Printer
Equipment Class
DTS - Digital Transmission System
Mobile Printer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterBarcode Printer, Label Printer, Barcode Label Printer, Direct Thermal Printer, Direct Thermal Label Printer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Barcode Printer
Equipment Class
NII - Unlicensed National Information Infrastructure TX
1) Portable Photo Printer, 2) Mini Photo Printer, 3) Dye-Sublimation Photo Printer, 4) Photo Printer
Equipment Class
DTS - Digital Transmission System