FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou SuperAcme Electronics Technology Co., Ltd./
  3. 2BMXI-CMC2U

2BMXI-CMC2USecurity Indoor Cam

Hangzhou SuperAcme Electronics Technology Co., Ltd.
Security Indoor Cam - FCC ID 2BMXI-CMC2U - Hangzhou SuperAcme Electronics Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 13, 2025
Application Purpose
Original Equipment
Equipment Note
Security Indoor Cam
Frequency Range
2402.00000000 - 2480.00000000
Company
Hangzhou SuperAcme Electronics Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202412-0172-4 Page: 1 of 5 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Maximum Permissible Exposure Evaluation FCC ID: 2BMXI-CMC2U 1. General Information about EUT 1.1 Client Information Applicant : Hangzhou SuperAcme Electronics Technology Co., Ltd. Address : 14th Floor, Building 2, Silergy Plaza, 6 Lianhui St., Binjiang District, Hangzhou, Zhejiang Province,China Manufacturer : Hangzhou SuperAcme Electronics Technology Co., Ltd. Address : 14th Floor, Building 2, Silergy Plaza, 6 Lianhui St., Binjiang District, Hangzhou, Zhejiang Province,China 1.2 General Description of EUT (Equipment Under Test) EUT Name : Security Indoor Cam Models No. : CM-C2U, CM-C1U,CM-C3U,CM-C4U,CM-C5U,CM-C6U, CM-C7U,CM-C8U,CM-C9U,CM-C2LU,CM-C3LU,CM-C4LU, CM-C5LU,CM-C6LU,CM-C7LU,CM-C8LU,CM-C9LU, CM-CB2U,CM-CB3U,CM-CB4U,CM-CB5U,CM-CB6U, CM-CB7U,CM-CB8U,CM-CB9U Model Different : All these models are identical in the same PCB, layout and electrical circuit, The only difference is model name, brand name and product name. Brand Name : CINMOORE Sample ID : HC-C-202412-0172-01-01 Product Description : Operation Frequency: BLE: 2402MHz~2480MHz U-NII-1: 5180MHz~5240MHz U-NII-2A: 5260MHz~5320MHz U-NII-2C: 5500MHz~5700MHz U-NII-3: 5745MHz~5825MHz 802.11b/g/n(HT20)/n(HT40): 2412MHz~2462MHz Power Rating : Adapter:(DYS05100CP-U1) Input: 100-240V~, 50/60Hz 0.15A Output: 5.0V⎓1.0A,5.0W Software Version : N/A Hardware Version : N/A Report No.: TBR-C-202412-0172-4 Page: 2 of 5 TB-RF-074-1.0 1.3 Antenna Information Band Antenna Type Antenna Gain(dBi) BLE FPC 3.24 2.4G Wi-Fi FPC 3.24 U-NII-1 5.1 U-NII-2A 5.48 U-NII-2C 5.34 U-NII-3 4.58 Remark: The above antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible. Report No.: TBR-C-202412-0172-4 Page: 3 of 5 TB-RF-074-1.0 2. Method of Measurement for FCC 1. EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 2. Exposure Evaluation: Equation from page 18 of OET Bulletin 65, Edition 97-01 S=(PG)/4πR 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna Simultaneous transmission MPE Considerations According to KDB447498: All transmitters and antennas in the host must be either evaluated for MPE compliance, by measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1. Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. This means that: ∑ of MPE ratios ≤ 1.0 Report No.: TBR-C-202412-0172-4 Page: 4 of 5 TB-RF-074-1.0 3. Test Result: Test Mode Conducted Power(max) (dBm) Turn-up Power (dB) Max tune up power (dBm) [P] Max. ANT Gain (dBi) [G] Distance (cm) [R] Power Density (mW/ cm 2 ) [S] BLE 8.358 8±1 9 3.24 20 0.00333 2.4G b 16.23 16±1 17 3.24 20 0.02103 2.4G g 15.05 16±1 17 3.24 20 0.02103 2.4G n20 16.17 16±1 17 3.24 20 0.02103 2.4G n40 16.06 16±1 17 3.24 20 0.02103 2.4G ax20 17.54 17±1 18 3.24 20 0.02647 2.4G ax40 17.69 17±1 18 3.24 20 0.02647 5G a 18.00 18±1 19 5.48 20 0.05581 5G n20 16.80 16±1 17 5.48 20 0.03522 5G n40 16.32 16±1 17 5.48 20 0.03522 5G ac20 17.84 17±1 18 5.48 20 0.04433 5G ac40 15.51 16±1 17 5.48 20 0.03522 5G ax20 18.38 18±1 19 5.48 20 0.05581 5G ax40 16.32 17±1 18 5.48 20 0.04433 Report No.: TBR-C-202412-0172-4 Page: 5 of 5 TB-RF-074-1.0 4. Conclusion: As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE), Limits for General Population/ Uncontrolled Exposure Frequency Range (MHz) Power density (mW/ cm 2 ) 300-1,500 F/1500 1,500-100,000 1.0 For: 2402~2480MHz&2412~2462MHz&5180~5825MHz MPE limit S: 1mW/ cm 2 The MPE is calculated as 0.05581 mW / cm2 < limit 1mW / cm2. --- END OF REPORT ---

Test Setup Photos

FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Appendix V EUT Test Photographs Conducted Emission Test Setup Radiated Emission Test Setup-Below 1G FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Photo of Setup for Radiated Emission (Above 1 GHz) DFS test photos -----END OF REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202412-0172-11 Page: 1 of 32 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 RF Test Report FCC ID: 2BMXI-CMC2U Report No. : TBR-C-202412-0172-11 Applicant : Hangzhou SuperAcme Electronics Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : Security Indoor Cam Model No. : CM-C2U Series Model No. : CM-C1U,CM-C3U,CM-C4U,CM-C5U,CM-C6U,CM-C7U,CM-C8U, CM-C9U,CM-C2LU,CM-C3LU,CM-C4LU,CM-C5LU,CM-C6LU, CM-C7LU,CM-C8LU,CM-C9LU,CM-CB2U,CM-CB3U,CM-CB4U, CM-CB5U,CM-CB6U,CM-CB7U,CM-CB8U,CM-CB9U Brand Name : CINMOORE Sample ID : HC-C-202412-0172-01-01&HC-C-202412-0172-02-01 Receipt Date : 2024-12-19 Test Date : 2024-12-19 to 2025-01-02 Issue Date : 2025-01-02 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Rick chen Reviewed By : Henry huang Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202412-0172-11 Page: 2 of 32 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................ 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................ 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 6 1.5 Description of Test Mode ................................................................................................... 7 1.6 Description of Test Software Setting ................................................................................ 8 1.7 Measurement Uncertainty .................................................................................................. 9 1.8 Test Facility........................................................................................................................... 9 2. TEST SUMMARY..................................................................................................................... 10 3. TEST SOFTWARE .................................................................................................................. 10 4. TEST EQUIPMENT AND TEST SITE .................................................................................. 11 5. CONDUCTED EMISSION TEST ........................................................................................... 12 5.1 Test Standard and Limit ................................................................................................... 12 5.2 Test Setup........................................................................................................................... 12 5.3 Test Procedure .................................................................................................................. 12 5.4 Deviation From Test Standard......................................................................................... 12 5.5 EUT Operating Mode ........................................................................................................ 13 5.6 Test Data............................................................................................................................. 13 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 14 6.1 Test Standard and Limit ................................................................................................... 14 6.2 Test Setup........................................................................................................................... 15 6.3 Test Procedure .................................................................................................................. 16 6.4 Deviation From Test Standard......................................................................................... 17 6.5 EUT Operating Mode ........................................................................................................ 17 6.6 Test Data............................................................................................................................. 17 7. RESTRICTED BANDS AND BAND EDGE REQUIREMENT .......................................... 18 7.1 Test Standard and Limit ................................................................................................... 18 7.2 Test Setup........................................................................................................................... 18 7.3 Test Procedure .................................................................................................................. 19 7.4 Deviation From Test Standard......................................................................................... 20 7.5 EUT Operating Mode ........................................................................................................ 20 7.6 Test Data............................................................................................................................. 20 8. BANDWIDTH TEST...........................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202412-0172-1 Page: 1 of 31 TB-RF-074-1.0 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 Radio Test Report FCC ID: 2BMXI-CMC2U Report No. : TBR-C-202412-0172-1 Applicant : Hangzhou SuperAcme Electronics Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : Security Indoor Cam Model No. : CM-C2U Series Model No. : CM-C1U,CM-C3U,CM-C4U,CM-C5U,CM-C6U,CM-C7U,CM-C8U, CM-C9U,CM-C2LU,CM-C3LU,CM-C4LU,CM-C5LU,CM-C6LU, CM-C7LU,CM-C8LU,CM-C9LU,CM-CB2U,CM-CB3U,CM-CB4U, CM-CB5U,CM-CB6U,CM-CB7U,CM-CB8U,CM-CB9U Brand Name : CINMOORE Sample ID : HC-C-202412-0172-01-01&HC-C-202412-0172-02-01 Receipt Date : 2024-12-19 Test Date : 2024-12-19 to 2025-01-02 Issue Date : 2025-01-02 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Rick chen Reviewed By : Henry huang Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202412-0172-1 Page: 2 of 31 TB-RF-074-1.0 Contents CONTENTS ............................................................................................................................................ 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................ 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode ................................................................................................... 7 1.6 Description of Test Software Setting ................................................................................ 8 1.7 Measurement Uncertainty .................................................................................................. 8 1.8 Test Facility........................................................................................................................... 9 2. TEST SUMMARY..................................................................................................................... 10 3. TEST SOFTWARE .................................................................................................................. 10 4. TEST EQUIPMENT AND TEST SITE .................................................................................. 11 5. CONDUCTED EMISSION ...................................................................................................... 12 5.1 Test Standard and Limit ................................................................................................... 12 5.2 Test Setup........................................................................................................................... 12 5.3 Test Procedure .................................................................................................................. 12 5.4 Deviation From Test Standard......................................................................................... 13 5.5 EUT Operating Mode ........................................................................................................ 13 5.6 Test Data............................................................................................................................. 13 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 14 6.1 Test Standard and Limit ................................................................................................... 14 6.2 Test Setup........................................................................................................................... 15 6.3 Test Procedure .................................................................................................................. 16 6.4 Deviation From Test Standard......................................................................................... 17 6.5 EUT Operating Mode ........................................................................................................ 17 6.6 Test Data............................................................................................................................. 17 7. RESTRICTED BANDS AND BAND EDGE REQUIREMENT .......................................... 18 7.1 Test Standard and Limit ................................................................................................... 18 7.2 Test Setup........................................................................................................................... 18 7.3 Test Procedure .................................................................................................................. 19 7.4 Deviation From Test Standard......................................................................................... 19 7.5 EUT Operating Mode ........................................................................................................ 19 7.6 Test Data............................................................................................................................. 19 8. BANDWIDTH TEST.....................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 47 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT ax(VHT40) 2422MHz Ant1 Ref Band Edge NVNT ax(VHT40) 2422MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 48 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT ax(VHT40) 2452MHz Ant1 Ref Band Edge NVNT ax(VHT40) 2452MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 49 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT b 2412MHz Ant1 Ref Band Edge NVNT b 2412MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 50 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT b 2462MHz Ant1 Ref Band Edge NVNT b 2462MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 51 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT g 2412MHz Ant1 Ref Band Edge NVNT g 2412MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 52 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT g 2462MHz Ant1 Ref Band Edge NVNT g 2462MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 53 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT n(HT20) 2412MHz Ant1 Ref Band Edge NVNT n(HT20) 2412MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 54 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT n(HT20) 2462MHz Ant1 Ref Band Edge NVNT n(HT20) 2462MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 55 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT n(HT40) 2422MHz Ant1 Ref Band Edge NVNT n(HT40) 2422MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 56 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Band Edge NVNT n(HT40) 2452MHz Ant1 Ref Band Edge NVNT n(HT40) 2452MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 57 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 7. Conducted RF Spurious Emission Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT ax(VHT20) 2412 Ant1 -47.48 -30 Pass NVNT ax(VHT20) 2437 Ant1 -43.23 -30 Pass NVNT ax(VHT20) 2462 Ant1 -45.98 -30 Pass NVNT ax(VHT40) 2422 Ant1 -45.12 -30 Pass NVNT ax(VHT40) 2437 Ant1 -41.62 -30 Pass NVNT ax(VHT40) 2452 Ant1 -44.76 -30 Pass NVNT b 2412 Ant1 -41.97 -30 Pass NVNT b 2437 Ant1 -42.23 -30 Pass NVNT b 2462 Ant1 -41.36 -30 Pass NVNT g 2412 Ant1 -47.07 -30 Pass NVNT g 2437 Ant1 -47.64 -30 Pass NVNT g 2462 Ant1 -44.78 -30 Pass NVNT n(HT20) 2412 Ant1 -45 -30 Pass NVNT n(HT20) 2437 Ant1 -45.2 -30 Pass NVNT n(HT20) 2462 Ant1 -46.93 -30 Pass NVNT n(HT40) 2422 Ant1 -44.29 -30 Pass NVNT n(HT40) 2437 Ant1 -45.16 -30 Pass NVNT n(HT40) 2452 Ant1 -45.01 -30 Pass Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 58 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Test Graphs Tx. Spurious NVNT ax(VHT20) 2412MHz Ant1 Ref Tx. Spurious NVNT ax(VHT20) 2412MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 59 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Tx. Spurious NVNT ax(VHT20) 2437MHz Ant1 Ref Tx. Spurious NVNT ax(VHT20) 2437MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 60 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Tx. Spurious NVNT ax(VHT20) 2462MHz Ant1 Ref Tx. Spurious NVNT ax(VHT20) 2462MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 61 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Tx. Spurious NVNT ax(VHT40) 2422MHz Ant1 Ref Tx. Spurious NVNT ax(VHT40) 2422MHz Ant1 Emission Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 62 of 89 F…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 1 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 RF Test Data for 2.4G WiFi (Conducted Measurements) General Description of EUT Product Name: Security Indoor Cam Test Model: CM-C2U Sample ID: HC-C-202412-0172-01-01 Environmental Conditions Temperature: 24.6°C Relative Humidity: 48.6% Test Voltage: DC 5V Test Engineer: Rick chen Note: For a more detailed features description, please refer to the report TBR-C-202412-0172-11 The report only show the worst case data. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 2 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Contents 1. Duty Cycle ..................................................................................................................................................................................... 3 2. Maximum Conducted Output Power .......................................................................................................................................... 13 3. -6dB Bandwidth ........................................................................................................................................................................... 14 4. Occupied Channel Bandwidth .................................................................................................................................................... 24 5. Maximum Power Spectral Density Level ................................................................................................................................... 34 6. Band Edge ................................................................................................................................................................................... 44 7. Conducted RF Spurious Emission ............................................................................................................................................. 57 8. Restrict Band ............................................................................................................................................................................... 76 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 3 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 1. Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT ax(VHT20) 2412 Ant1 35.8 4.46 3.45 NVNT ax(VHT20) 2437 Ant1 35.37 4.51 3.45 NVNT ax(VHT20) 2462 Ant1 34.57 4.61 3.57 NVNT ax(VHT40) 2422 Ant1 35 4.56 3.57 NVNT ax(VHT40) 2437 Ant1 34.57 4.61 3.57 NVNT ax(VHT40) 2452 Ant1 35.8 4.46 3.45 NVNT b 2412 Ant1 94.29 0.26 0.12 NVNT b 2437 Ant1 94.18 0.26 0.12 NVNT b 2462 Ant1 94.18 0.26 0.12 NVNT g 2412 Ant1 72.92 1.37 0.71 NVNT g 2437 Ant1 72.92 1.37 0.71 NVNT g 2462 Ant1 72.92 1.37 0.71 NVNT n(HT20) 2412 Ant1 50.47 2.97 1.85 NVNT n(HT20) 2437 Ant1 50.47 2.97 1.85 NVNT n(HT20) 2462 Ant1 50.47 2.97 1.85 NVNT n(HT40) 2422 Ant1 50.48 2.97 1.89 NVNT n(HT40) 2437 Ant1 50.48 2.97 1.89 NVNT n(HT40) 2452 Ant1 50.48 2.97 1.89 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 4 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Test Graphs Duty Cycle NVNT ax(VHT20) 2412MHz Ant1 Duty Cycle NVNT ax(VHT20) 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 5 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT ax(VHT20) 2462MHz Ant1 Duty Cycle NVNT ax(VHT40) 2422MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 6 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT ax(VHT40) 2437MHz Ant1 Duty Cycle NVNT ax(VHT40) 2452MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 7 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 8 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT b 2462MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 9 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 10 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT n(HT20) 2412MHz Ant1 Duty Cycle NVNT n(HT20) 2437MHz Ant1 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-11 Page: 11 of 89 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Duty Cycle NVNT n(HT20)…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-1 Page: 1 of 39 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 RF Test Data for Bluetooth LE (Conducted Measurements) General Description of EUT Product Name: Security Indoor Cam Test Model: CM-C2U Sample ID: HC-C-202412-0172-01-01 Environmental Conditions Temperature: 24.6°C Relative Humidity: 48.6% Test Voltage: DC 5V Test Engineer: Rick chen Note: For a more detailed features description, please refer to the report TBR-C-202412-0172-1 The report only show the worst case data. Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202412-0172-1 Page: 2 of 39 FCC ID: 2BMXI-CMC2U TB-RF-074-1.0 Contents 1. Duty Cycle ..................................................................................................................................................................................... 3 2. Maximum Conducted Output Power ............................................................................................................................................ 7 3. -6dB Bandwidth ........................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yongzhi Wang(manager)
[email protected]Fax: N/A

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz6.90 mW
215C2.41 GHz - 2.46 GHz58.70 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device supports 802.11b, 802.11g, 802.11n and 802.11ax with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Hangzhou SuperAcme Electronics Technology Co., Ltd.

All-in-One Solar AI Wi-Fi Security Camera - FCC ID 2BMXI-CMBC7WU - Hangzhou SuperAcme Electronics Technology Co., Ltd.
2BMXI-CMBC7WU

All-in-One Solar AI Wi-Fi Security Camera

May 15, 2026

Equipment Class

DTS - Digital Transmission System
Battery Wireless Window Camera - FCC ID 2BMXI-CMBC22EU - Hangzhou SuperAcme Electronics Technology Co., Ltd.
2BMXI-CMBC22EU

Battery Wireless Window Camera

Apr 29, 2026

Equipment Class

DTS - Digital Transmission System
Outdoor Wi-Fi Camera - FCC ID 2BMXI-CMPT2WU - Hangzhou SuperAcme Electronics Technology Co., Ltd.
2BMXI-CMPT2WU

Outdoor Wi-Fi Camera

Apr 20, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
smart battery camera - FCC ID 2BMXI-CMBC5U - Hangzhou SuperAcme Electronics Technology Co., Ltd.
2BMXI-CMBC5U

smart battery camera

Feb 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Security Indoor Camera - FCC ID 2BMXI-CMC2LU - Hangzhou SuperAcme Electronics Technology Co., Ltd.
2BMXI-CMC2LU

Security Indoor Camera

Dec 01, 2025

Equipment Class

DTS - Digital Transmission System