• Cassettes marked “VHS” (or “S-VHS”) can be used with this video cassette recorder. However, S-VHS recording is not possible with this model. • This model is equipped with SQPB (S-VHS QUASI PLAYBACK) that makes it possible to play back S-VHS recordings with regular VHS resolution. • HQ VHS is compatible with existing VHS equipment. • As an Energy Star® Partner, JVC has determined that this product or product model meets the Energy Star® guidelines for energy efficiency. VIDEO CASSETTE RECORDER HR-A592U INSTRUCTIONS LPT0661-001B COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD. Printed in Thailand Dear Customer, Thank you for purchasing the JVC VHS video cassette recorder. Before use, please read the safety information and precautions to ensure safe use of your new VCR. CAUTIONS WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. CAUTION: This video cassette recorder should be used with AC 120V~, 60Hz only. To prevent electric shocks and fire hazards, DO NOT use any other power source. CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. ATTENTION: POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU’AU FOND. Note to CATV system installer: This reminder is provided to call the CATV system installer’s attention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practical. CAUTION: Changes or modifications not approved by JVC could void user’s authority to operate the equipment. Failure to heed the following precautions may result in damage to the VCR, Remote or video cassette. 1DO NOT place the VCR . . . ...in an environment prone to extreme temperatures or humidity. ...in direct sunlight. ...in a dusty environment. ...in an environment where strong magnetic fields are generated. ...on a surface that is unstable or subject to vibration. 2.DO NOT block the VCR’s ventilation openings. 3.DO NOT place heavy objects on the VCR or on the Remote. 4.DO NOT place anything which might spill on the top of the VCR or on the Remote. 5.AVOID violent shocks to the VCR during transport. For Customer Use: Enter below the Model No. and Serial No. which are located on the rear of cabinet. Retain this information for future reference. Model No. Serial No. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. 4F21601B K 02/01 4F21601B Cov-0722/12/2001, 12:251 IMPORTANT PRODUCT SAFETY INSTRUCTIONS Electrical energy can perform many useful functions. But improper use can result in potential electrical shock or fire hazards. This product has been engineered and manufactured to assure your personal safety. In order not to defeat the built-in safeguards, observe the following basic rules for its installation, use and servicing. ATTENTION: Follow and obey all warnings and instructions marked on your product and its operating instructions. For your safety, please read all the safety and operating instructions before you operate this product and keep this booklet for future reference. INSTALLATION 1. Grounding or Polarization (A) Your product may be equipped with a polarized alternating- current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug. (B) Your product may be equipped with a 3-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug. 2. Power Sources Operate your product only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. If your product is intended to operate from battery power, or other sources, refer to the operating instructions. 3. Overloading Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fire or electric shock. 4. Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product. 5. Ventilation Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these openings must not be blocked or covered. • Do not block the openings by placing the product on a bed, sofa, rug or other similar surface. • Do not place the product in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to. 6. Wall or Ceiling Mounting The product should be mounted to a wall or ceiling only as recommended by the manufacturer. ANTENNA INSTALLATION INSTRUCTIONS 1. Outdoor Antenna Grounding If an outside antenna or cable system is connected to the…
Text truncated - open the document above for the full version.
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 October 15, 2002 RE: FCC ID: A7RM4F9A Attention: Mr. Hisayuki Kioka I have a few comments on this Application. 1 The first section of the report contains non-English fonts. The FCC server cannot open documents that contain non-English fonts. Please provide a test report that does not contain non-English fonts. 2 The FCC requires separate files for setup photos. Please provide a separate document file for Test setup photos. 3 The manual does not appear to have the interference statement of 15.105. Please provide a corrected manual with this information. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
Test report No. : 23BE0048-YW-1 Page : 2 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Contents Page Section 1 : Client information 3 Section 2 : Equipment under test (E.U.T.) 3 Section 3 : Test specification, procedures & results 4 Section 4 : Operation of E.U.T. during tests 6 Section 5 : Conducted emission 7 Section 6 : Radiated emission 10 Section 7 : Antenna terminal voltage 13 Section 8 : RF output level / spurious emission 14 Section 9 : Antenna transfer switch 15 Section 10 : Picture sensitivity 16 Section 11 : Noise figure 17 Contents of Appendixes 18 Appendix 1 : Photographs of test set up 19 Appendix 2 : Data of EMI tests 26 Appendix 3: Test instruments 79 Test report No. : 23BE0048-YW-1 Page : 3 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Section 1 : Client information Company name : Orion Electric Co., Ltd. Brand Name : JVC Address : 41-1 Iehisa-cho, Takefu-shi, Fukui-ken, 915-8555 JAPAN Telephone number : +81 778 23 0019 Facsimile number : +81 778 23 7799 Contact person : Hiroshi Tsujimoto Manufacture Company name : Orion Electric (U.K.) Ltd. World Electric (Thailand) Ltd. Korat Denki Ltd. Section 2 : Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of equipment : Video Cassette Recorder Model number : HR-A592U Rating : AC 120 V / 60 Hz Receipt Date of Sample : September 27, 2002 Condition of EUT : Production Prototype 2.2 Product description Orion Electronics Co., Ltd. Model: HR-A592U (referred to as the EUT in this report) is a Video Cassette Recorder. The EUT specifications is as follows. Tuner type : Quartz PLL frequency synthesized I / F : 45.75 MHz (Picture), 41.25 MHz (Sound) Receiving channel : VHF 2 – 13 ch / UHF 14 – 69 ch / CATV 1 – 125 ch Antenna input : 75 ohm Video signal : NTSC color Power source : AC 120 V / 60 Hz, 9 W I / O terminal (Video) : RCA in 1Vp-p 75 ohm, RCA out 1 Vp-p 75 ohm I / O terminal (Audio) : RCA in –8 dB 47 k ohm, RCA out –8 dB 1 k ohm 2.3 Similar apparatus There are no similar apparatus. Test report No. : 23BE0048-YW-1 Page : 4 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Section 3 : Test specification, procedures and results 3.1 Test specification Test specification : FCC Part 15 Subpart B Title : FCC 47 CFR Part 15 Radio Frequency Device Subpart B Unintentional Radiators 3.2 Procedures & results Item Test procedure Limits Worst margin Result Conducted emission ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 250 uV 6.3 dB (0.45 MHz) Complied Radiated emission ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 30–88 MH: 100 uV/m 88–216 MHz: 150 uV/m 216–960 MHz: 200 uV/m above 960 MHz: 500 uV/m 8.7 dB (845 MHz) Complied Antenna terminal voltage ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 2 nW (at 75 ohm) 11.0 dB (1549.28198 MHz) Complied RF output level Video signal: 3000 uV Aural signal: 671 uV 2.4 dB (61.25 MHz) Complied Spurious emission ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 94.8 uV 18.7 dB (166.3 MHz) Complied Transfer switch ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 9.5 dB 4.4 dB (232.25 MHz) Complied Picture sensitivity ANSI C63.4:1992 IEEE 213:1987 IEEE 187:1990 8 dB 5.6 dB Complied Noise figure FCC/OET MP:2:1986 14 dB 7.0 dB (133.25 MHz) Complied 3.3 Additions or deviations to standard No addition, deviation or exclusion has been made from standards. 3.4 Confirmation A-Pex International Co., Ltd. hereby confirms that E.U.T., in the configuration tests, complies with the specifications FCC Part15 Subpart B. Test report No. : 23BE0048-YW-1 Page : 5 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) 3.5 Uncertainty Conducted emission (450 kHz – 30 MHz) The measurement uncertainty (with a 95% confidence level) for this test was ± 1.74 dB. The data listed in this test report has enough margin, more than site margin. Radiated emission The measurement uncertainty (with a 95% confidence level) for this test using Biconical antenna is ±4.4 dB. The measurement uncertainty (with a 95% confidence level) for this test using Logperiodic antenna is ±4.8 dB. The measurement uncertainty (with a 95% confidence level) for this test using Horn antenna is ±5.8 dB. The data listed in this test report has enough margin, more than site margin. Antenna terminal voltage The measurement uncertainty (with a 95% confidence level) for this test was ± 3.48 dB. The data listed in this test report has enough margin, more than site margin. RF output level test / spurious emission test The measurement uncertainty (with a 95% confidence level) for this test was ± 3.48 dB. The data listed in this test report may exceed the test limit because it does not have enough margin. Antenna transfer switch The measurement uncertainty (with a 95% confidence level) for this test was ± 3.48 dB. The data listed in this test report has enough margin, more than site margin. Picture sensitivity test The measurement uncertainty (with a 95% confidence level) for this test was ± 1.0 dB. The data listed in this test report has enough margin, more than site margin. Noise Figure Test The measurement uncertainty (with a 95% confidence level) for this test was ± 1.2 dB. The data listed in this test report has enough margin, more than site margin. 3.7 Test location A-Pex International Co., Ltd. Yokowa Lab. No.1 and No.2 Test site 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPAN TEL : +81 596 39 1485 FAX : +81 596 39 0232 No.1 Test site This site has been fully described in a rep…
Text truncated - open the document above for the full version.
Test report No. : 23BE0048-YW-1 Page : 19 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Conducted emission Test report No. : 23BE0048-YW-1 Page : 20 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Radiated emission Test report No. : 23BE0048-YW-1 Page : 21 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Antenna terminal voltage Test report No. : 23BE0048-YW-1 Page : 22 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) RF output level / spurious emission Test report No. : 23BE0048-YW-1 Page : 23 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Antenna transfer switch Test report No. : 23BE0048-YW-1 Page : 24 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Picture sensitivity Test report No. : 23BE0048-YW-1 Page : 25 of 79 Date of issue : October 10, 2002 A-Pex International Co., Ltd. YOKOWA LAB. 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPAN Telephone: +81 596 39 1485 Facsimile: +81 596 39 0232 MF060b(24.04.02) Noise figure
108 Yokowa-cho · Ise-shi, Mie-ken · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15B | 67.25 MHz - 71.75 MHz | - |

BLUETOOTH MODULE
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DVD / VCR TV Interface Device
Equipment Class
HID - Part 15 TV Interface Device
DVD / VCR TV Interface Device
Equipment Class
HID - Part 15 TV Interface Device
DVD / VCR TV Interface Device
Equipment Class
HID - Part 15 TV Interface Device
DVD/VCR TV Interface Device
Equipment Class
HID - Part 15 TV Interface Device