Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MARINE RADAR MODEL 1715 Your Local Agent/DealerYour Local Agent/Dealer 9-52 Ashihara-cho,9-52 Ashihara-cho, Nishinomiya, JapanNishinomiya, Japan Telephone :Telephone :0798-65-21110798-65-2111 Telefax :Telefax :0798-65-42000798-65-4200 FIRST EDITION :FIRST EDITION : . .00000000 Printed in JapanPrinted in Japan All rights reserved.All rights reserved. PUB.No.PUB.No.OME-35140OME-35140 *00014791100**00014791100* *00014791100**00014791100* (()) MODEL1715MODEL1715 * 0 0 0 1 4 7 9 1 1 0 0 ** 0 0 0 1 4 7 9 1 1 0 0 * *OME35140Z00**OME35140Z00* *OME35140Z00**OME35140Z00* * O M E 3 5 1 4 0 Z 0 0 ** O M E 3 5 1 4 0 Z 0 0 * i TABLE OF CONTENTS SAFETY INSTRUCTIONS............................ ii FOREWORD............................................... iii SYSTEM CONFIGURATION....................... iv EQUIPMENT LISTS ..................................... v 1. OPERATION ........................................... 1 1.1 Controls .................................................. 1 1.2 Indications .............................................. 2 1.3 Turning Power On/Off ............................ 3 1.4 Transmitting, Standby............................. 3 1.5 Adjusting Display Contrast, Brilliance .... 4 1.6 Choosing the Range .............................. 4 1.7 Receiver Sensitivity................................ 4 1.8 Suppressing Sea Clutter ........................ 5 1.9 Suppressing Rain Clutter ....................... 6 1.10 Measuring the Range ............................. 6 1.11 Measuring the Bearing ........................... 7 1.12 Shifting the Display ................................ 7 1.13 Zoom ...................................................... 8 1.14 User Menu Overview.............................. 8 1.15 Heading Line .......................................... 9 1.16 Interference Rejector.............................. 9 1.17 Noise Rejector...................................... 10 1.18 Echo Trail, Trail Brilliance ..................... 10 1.19 Echo Stretch ......................................... 10 1.20 Guard Alarm ..........................................11 1.21 Watchman ............................................ 12 1.22 Suppressing Long-range Rain Clutter.. 12 1.23 Panel Backlighting................................ 12 1.24 Hue ....................................................... 13 1.25 Resetting Distance Run ....................... 13 1.26 PROG Key............................................ 13 1.27 Outputting Target Position to a Plotter . 13 1.28 Turning Navigation Data On/Off ........... 14 1.29 Setting up Nav Data Displays .............. 14 1.30 System Menu ....................................... 16 2. MAINTENANCE, TROUBLESHOOTING..... 18 2.1 Maintenance ......................................... 18 2.2 Replacing the Fuse............................... 19 2.3 Troubleshooting .................................... 19 2.4 Diagnostics ........................................... 20 2.5 Test Pattern........................................... 21 2.6 Clearing the Memory ............................ 21 2.7 Replacing the Magnetron ..................... 21 2.8 Replacing the Synchro Belt .................. 21 3. INSTALLATION..................................... 22 3.1 Antenna Unit Installation....................... 22 3.2 Display Unit Installation ........................ 25 3.3 Wiring.................................................... 25 3.4 Adjustments .......................................... 26 3.5 Magnetron Heater Voltage.................... 29 MENU TREE.............................................. 30 SPECIFICATIONS ..................................SP-1 PACKING LIST OUTLINE DRAWINGS INTERCONNECTION DIAGRAM SCHEMATIC DIAGRAMS ii SAFETY INSTRUCTIONS Safety Instructions for the Operator WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar antenna mast. Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can result. Turn off the power immediately if water leaks into the equipment or the equip- ment is emitting smoke or fire. Continued use of the equipment can cause fire or electrical shock. Use the proper fuse. Use of a wrong fuse can damage the equipment and void the warranty. WARNING LABEL A warning label is attached to the equipment. Do not remove the label. If the label is missing or damaged, contact a FURUNO agent or dealer about replacement. WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside. Name: Warning Label (1) Type: 86-003-1011-1 Code No.: 100-236-231 CAUTION Safety Instructions for the Installer Observe the following compass safe distances to prevent interference to a magnetic compass: Standard Steering compass compass 0.60 m 0.40 m Antenna unit 1.25 m 0.85 m Display unit ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar antenna mast. WARNING Construct a suitable service platform from which to install the antenna unit. Serious injury or death can result if some- one falls from the radar antenna mast. Be sure that the power supply is compatible with the voltage rating of the equipment. Connection of an incorrect power supply can cause fire or damage the equipment. Use only the specified power cable. Fire or damage to the equipment can result if a different cable is used. CAUTION iii FOREWORD A Word to the Owner of the MODEL 1715 Congratulations on your choice of the FURUNO MODEL 1715 Marine Radar. For over 50 years FURUNO Electric Company has enjoyed an enviable reputation for innovative and dependable marine electronics equipment. This dedication to …
Text truncated - open the document above for the full version.
Furuno Labotech International Report no.: FLI 12-03-031 Form: Q053/01 - Page 9 of 38 - 2Identification of Equipment (FCC Rule, 2.925) The following nameplates are permanently fixed on the corresponding equipment units. FCC ID: ADB9ZWRTR076 Material of nameplate: Polyester film, 0.1 mm thick 0560 Fig. 2.1 Nameplate forAntenna Unit Fig. 2.2 Nameplate for Display Unit MARINE RADAR TYPE SER. NO. ANTENNA UNIT FU RU NO ELECT RI C CO. , LTD . 9-5 2 A shiha ra -Cho, Nishinomiya Cit y, Japan MA DE IN JAP AN COMPASS SAFE DIST ANCE m STEER mSTD FCC ID: ADB9ZWRTR076 FURUNO USA, INC. TYPE SER. NO. DISPLAY UNIT COMPASS SAFE DIST ANCE STD mm FURUNO ELECTRIC CO., LTD. STEER MARINE RADAR RSB-0095 R133-0002 RDP-142 4316-0002 Nishinomiya City, MADE IN JAPA N 0560 INPUT12 - 24 VDC MODEL 1715
Furuno Labotech International Report no.: FLI 12-03-031 - Page E.9 of 18 - 1.9 Name Plate
Furuno Labotech International Report no.: FLI 12-03-031 - Page E.1 of 18 - Attachment E Photographs of EUT MODEL 1715 (Transceiver type RTR-076) 1 Antenna Unit RSB-0095 (including Transceiver RTR-076) 1.1 Outside View (showing Name Plate.) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.2 of 18 - 1.2 Inside View (with Top cover removed, Showing Antenna Radiator and Transceiver Module (RTR-076)) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.3 of 18 - 1.3 Inside View (w ith Top cov er remov ed, Show ing Antenna Radiator and Transceiv er Module (RTR-076)) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.4 of 18 - 1.4 Inside View (with shield-covers removed, showing Magnetron (lower right), MIC (Upper right), MD Board 03P9270 (lower left), Scanner Motor (center), IF Board 03P9321 (upper center), and INT Board 03P9322 (upper left)) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.5 of 18 - 1.5 IF 03P9321 (upper) and INT 03P9322 (lower) Boards Front side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.6 of 18 - 1.6 IF 03P9321 (upper) and INT 03P9322 (lower) Boards Rear side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.7 of 18 - 1.7 MD Board 03P9270 Front side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.8 of 18 - 1.8 MD Board 03P9270 Rear side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.9 of 18 - 1.9 Name Plate Furuno Labotech International Report no.: FLI 12-03-031 - Page E.10 of 18 - 2 Display Unit RDP-142 2.1 Front View Furuno Labotech International Report no.: FLI 12-03-031 - Page E.11 of 18 - 2.2 Rear side (showing Name Plate and Warning Label) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.12 of 18 - 2.3 Inside View (showing DU Board 03P9320 Front side) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.13 of 18 - 2.4 DU Board 03P9320 Rear side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.14 of 18 - 2.5 Inside View (with DU Board removed) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.15 of 18 - 2.6 Inside View (showing LCD Module) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.16 of 18 - 2.7 Inside View (showing Back of Front panel and PNL Board 03P9356 Rear side) Furuno Labotech International Report no.: FLI 12-03-031 - Page E.17 of 18 - 2.8 PNL Board 03P9356 Front side Furuno Labotech International Report no.: FLI 12-03-031 - Page E.18 of 18 - 2.9 Inside View (showing Back of Front Panel with PNL Board removed)
This report shall not be reproduced except in full, without the written approval of Furuno Labotech International Co., Ltd. TECHNICAL INFORMATION TEST REPORT ON THE PERFORMANCE OF MARINE RADAR Trade Name : FURUNO Transceiver Type : RTR-076 Report no.: FLI 12-03-031 Date of issue: July 3, 2003 Furuno Labotech International Co., Ltd. 9-52 Ashihara-cho, Nishinomiya City, Hyogo 662-8580, Japan Tel: +81-798-63-1094 Fax: +81-798-63-1098 Furuno Labotech International Report no.: FLI 12-03-031 Form: Q053/01 - Page 2 of 38 - * * * * * * C O N T E N T S * * * * * * 1General Information.................................................................................................................................... 3 2Identification of Equipment (FCC Rule, 2.925)........................................................................................ 9 3Test data..................................................................................................................................................... 10 3.1RF Power Output (FCC Rule, 2.1046)........................................................................................................ 10 3.2 Modulation Characteristics (FCC Rule, 2.1047)....................................................................................... 13 3.3Occupied Bandwidth (FCC Rule, 2.1049).................................................................................................. 18 3.4Spurious Emissions at Antenna Terminal (FCC Rule, 2.1051)................................................................. 20 3.5Field Strength of Spurious Radiation (FCC Rule, 2.1053)...................................................................... 24 3.6Frequency Stability (FCC Rule, 2.1055)..................................................................................................... 26 3.7Suppression of Interference Aboard Ships (FCC Rule, 80.217)............................................................... 29 4Photographs to Reveal Equipment Construction and Layout (FCC Rule, 2.1033)................... 33 5Description of Circuitry and Devices (FCC Rules, 2.1033)............................................................... 34 5.1 Function of Each Semiconductor or Active Device .................................................................................... 34 5.2 Description of the circuitry and devices provided for determining and stabilizing frequency, for suppression of spurious radiation, for limiting modulation, and for limiting power................................... 36 6Operator ’’ ’’ s Manual Incl. Circuit Diagrams (FCC Rule, 2.1033)......................................................... 38 Attachment A[ Test data for 3.4 Spurious Emissions at Antenna Terminal ] ......... A.1 - A.6 Attachment B[ Test data for 3.5 Field Strength of Spurious Radiation ] ......... B.1 - B.3 Attachment C[ Test data for 3.7 Suppression of Interference Aboard Ships ] ......... C.1 - C.21 Attachment D[ List of Test/ Measuring Equipment ] ......... D.1 - D.3 Attachment E[ Photographs of the EUT ] ......... E.1 - E.18 Furuno Labotech International Report no.: FLI 12-03-031 Form: Q053/01 - Page 3 of 38 - 1General Information 1.1General (a)Manufacturer:Furuno Electric Co., Ltd. Ashihara-cho 9-52, Nishinomiya-city, 662-8580 Japan (b)Model:MODEL 1715 TypeSerial Number Antenna unitRSB-0095R133-0002 Transceiver: RTR-076Contained in Antenna unit Radiator: RSB-0095 Display unitRDP-1424316-0002 (c)Primary Function:Search, Navigation and anticollison (d)Discrimination Range Discrimination:41 meters on a range scale of 1.5 nm Bearing Discrimination: 5.7° on a range scale of 1.5 nm, (e)Minimum Range: 34 meters on a range scale of 0.25 nm (f)Frequency Range:Fixed frequency, X-band Type of Emission:P0N (g)Power Supply: 12 - 24 VDC 1.2Antenna Unit 1.2.1Transceiver Type:RTR-076 (1)Transmitter (a)Assignable Frequency for Shipborne Radar: Between 9300 and 9500 MHz (FCC Rule: 80.375 (d)-(1)) (b)Type of RF Generator Magnetron Type:E3588 Peak Output Power:2.2 kW nominal (c)Magnetron Ratings Center frequency of Magnetron:9410 MHz Tolerances E3588 Manufacturing:±30 MHz Pulling:27 MHz Tolerance for 20°C temperature variation: -5 MHz Furuno Labotech International Report no.: FLI 12-03-031 Form: Q053/01 - Page 4 of 38 - (d)Guard Band: Guard Band is specified to be equal to 1.5/T MHz, where "T" is the pulselength in microseconds. See para (e). (FCC Rule: 80.209(b)) (e) Pulse Characteristics: Range Scale(Short)(Middle)(Long) (nm)0.125 (*1) 0.25 0.5 0.75 1 1.5 (*1) 2 3 4 6 8 12 16 24 (*1) Pulselength (μs)0.080.300.80 P.R.R.(Hz)30001200600 Duty cycle2.40X10 -4 3.60X10 -4 4.80X10 -4 Guard Band (MHz) 18.755.001.88 Note (*1): Tests were carried out for the underlined Range Scales. (2)Modulator (a)FET Type:2SK1449 Trigger Voltage: Approx. +10 VDC positive (3)Receiver (a)Passband (MHz) RF Stage:100 MHz IF Stage: PulselengthShortMiddleLong (MHz)1555 Furuno Labotech International Report no.: FLI 12-03-031 Form: Q053/01 - Page 5 of 38 - (b)Gain (overall) (dB):Sufficient to cause limiting, approximately 130 (c)Overall Noise Figure (dB): 10 (typical) (d)Video Output Voltage (V): 5 V positive (e)Features Provided: Sensitivity Time Controls (Anti-clutter Sea), Fast Time Constant (Anti-clutter Rain) (f)If receiver is tunable, describe method of adjusting frequency: Adjustment of tuning voltage of receiver local oscillator (Automatic and manual) 1.2.2Antenna (a)Antenna Rotation ON-OFF Switch: Not Provided. (b) Reflector:Microstrip antenna (contained in Radome) (c)Type of Beam:Vertical fan (d)Beam Width (between half-Radiator power points) Horizontal (°): 5.2 Vertical (°): 25 (e)Polarization:Horizontal (f)Antenna Gain: Ant. gain (dB): ≥ 20 (g)Attenuation of Major Side Lobes with respect to main beam: Within ±20° -20 dB Outside ±20° -25 dB (h)Scanning (rotating or oscillating): Rotating over 360° continuously clockwise (i)Antenna Rotation Rate:24, 31 or 41 rpm (corresponding to the range scale setting) (j)…
Text truncated - open the document above for the full version.
ii SAFETY INSTRUCTIONS Safety Instructions for the Operator WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar antenna mast. Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can result. Turn off the power immediately if water leaks into the equipment or the equip- ment is emitting smoke or fire. Continued use of the equipment can cause fire or electrical shock. WARNING LABEL A warning label is attached to the equipment. Do not remove the label. If the label is missing or damaged, contact a FURUNO agent or dealer about replacement. WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside. Name: Warning Label (1) Type: 86-003-1011-1 Code No.: 100-236-231 Safety Instructions for the Installer Observe the following compass safe distances to prevent interference to a magnetic compass: Use the proper fuse. Use of a wrong fuse can damage the equipment and void the warranty. Standard Steering compass compass 0.60 m 0.40 m Antenna unit 1.25 m 0.85 m Display unit ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar antenna mast. WARNING Construct a suitable service platform from which to install the antenna unit. Serious injury or death can result if some- one falls from the radar antenna mast. Be sure that the power supply is compatible with the voltage rating of the equipment. Connection of an incorrect power supply can cause fire or damage the equipment. Use only the specified power cable. Fire or damage to the equipment can result if a different cable is used. CAUTION The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar is in operation or expose yourself to the transmitting antenna at a close distance. Distances at which RF radiation levels of 100 and 10 W/m 2 exist are given in the table below. 100 W/m 2 10 W/m 2 0.1 m1.8 m
From: [email protected] Sent: Wednesday, August 20, 2003 3:48 AM To: Zanardi, Chuck Cc: Ametani, Shigenori; Miki Mitani (E-mail); Kitagawa, Kenji; Terada, Hideyuki; Ryan, Shane; Downs, Paul; [email protected] Subject: Re: CALCULATION FOR RF EXPOSURE Attn: Mr. Zanardi, Re: CALCULATION FOR RF EXPOSURE We measure the radiated energy from the radar in accordance with IEC 60945 (1996) Clause 12.2. The instrument so called Radiation Hazard Meter is used. The meter indicates the radiation power density in the readout of xx mW / square cm. We convert the readout into xx W / square m, and measure the distance to get the readout of 100 W/square m and 10 W/square m. Best regards, K. Kawabata -------------------------------------------------------------------------------- ------------ >9/18/03 >To: Kenji Kawabata > >Please advise when I will receive the information on RF exposure? This is >holding up the approval of the RTR076. > >Regards >C Zanardi >Commercial Service Manager >
Attachment A [ TEST DATA for Clause 3.4. SPURIOUS EMISSIONS AT ANTENNA TERMINALS ] 1. Spurious emissions for 0.125 nm Range: Ref. level: -14.56 dBm Emission limitations: (a)25 dB for 50 to 100 % of the authorized BW (100 MHz) (b)35 dB for 100 to 250 % of the authorized BW (100 MHz) Fig. 1.1 Without Filter Emission limitations: (c) 43 + 10 log Pm = 37.26 dB for more than 250 % of the authorized BW (100 MHz) Fig. 1.2 With Filter No.1 Emission limitations: (c) 43 + 10 log Pm = 37.26 dB for more than 250 % of the authorized BW (100 MHz) Fig. 1.3 With Filter No. 2 Furuno Labotech International Report no.: FLI 12-03-031 1- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 Emission limitations: (c) 43 + 10 log Pm = 37.26 dB for more than 250 % of the authorized BW (100 MHz) Fig. 1.4 With Filter No. 2 Emission limitations: (c) 43 + 10 log Pm = 37.26 dB for more than 250 % of the authorized BW (100 MHz) Fig. 1.5 With Filter No. 2 2- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 2. Spurious emissions for 1.5 nm Range: Ref. level: -3.25 dBm Emission limitations: (a)25 dB for 50 to 100 % of the authorized BW (100 MHz) (b)35 dB for 100 to 250 % of the authorized BW (100 MHz) Fig. 2.1 Without Filter Emission limitations: (c) 43 + 10 log Pm = 39.67 dB for more than 250 % of the authorized BW (100 MHz) Fig. 2.2 With Filter No.1 Emission limitations: (c) 43 + 10 log Pm = 39.67 dB for more than 250 % of the authorized BW (100 MHz) Fig. 2.3 With Filter No. 2 3- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 Emission limitations: (c) 43 + 10 log Pm = 39.67 dB for more than 250 % of the authorized BW (100 MHz) Fig. 2.4 With Filter No. 2 Emission limitations: (c) 43 + 10 log Pm = 39.67 dB for more than 250 % of the authorized BW (100 MHz) Fig. 2.5 With Filter No. 2 4- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 3. Spurious emissions for 24 nm Range: Ref. level: 4.02 dBm Emission limitations: (a)25 dB for 50 to 100 % of the authorized BW (100 MHz) (b)35 dB for 100 to 250 % of the authorized BW (100 MHz) Fig. 3.1 Without Filter Emission limitations: (c) 43 + 10 log Pm = 41.31 dB for more than 250 % of the authorized BW (100 MHz) Fig. 3.2 With Filter No.1 Emission limitations: (c) 43 + 10 log Pm = 41.31 dB for more than 250 % of the authorized BW (100 MHz) Fig. 3.3 With Filter No. 2 5- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 Emission limitations: (c) 43 + 10 log Pm = 41.31 dB for more than 250 % of the authorized BW (100 MHz) Fig. 3.4 With Filter No. 2 Emission limitations: (c) 43 + 10 log Pm = 41.31 dB for more than 250 % of the authorized BW (100 MHz) Fig. 3.5 With Filter No. 2 6- Page A. of 6 - Furuno Labotech International Report no.: FLI 12-03-031 - Page B.1 of 3 - ATTACHMENT B TEST DATA for Clause 3.5 FIELD STRENGTH OF SPURIOUS RADIATION Furuno Labotech International Report no.: FLI 12-03-031 - Page B.2 of 3 - Furuno Labotech International Report no.: FLI 12-03-031 - Page B.3 of 3 - Furuno Labotech International Report no.: FLI 12-03-031 - Page C .1 of 21 - ATTACHMENT C [ TEST DATA for Clause 3.7 SUPPRESSION OF INTERFERENCE ABOARD SHIPS ] 1 Harmful Interference to Receiver (Band: 14 kHz - 490 kHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .2 of 21 - (Band: 490 kHz - 5 MHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .3 of 21 - (Band: 5 MHz - 10 MHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .4 of 21 - (Band: 10 MHz - 30 MHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .5 of 21 - (Band: 30 MHz - 100 MHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .6 of 21 - (Band: 100 MHz - 300 MHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .7 of 21 - (Band: 300 MHz - 1 GHz) a) Radar Power: OFF b) Radar TX: O N Furuno Labotech International Report no.: FLI 12-03-031 - Page C .8 of 21 - 2 Electromagnetic Field (Band: 14 kHz - 490 MHz, Limit at 1 nm = 0.1 μV/m = -20 dBμV/m) a) Radar Power: OFF b) Radar TX: O N Ref. level = -26 dBμV/m Ref. level = -26 dBμV/m Furuno Labotech International Report no.: FLI 12-03-031 - Page C .9 of 21 - (Band: 490 kHz - 5 MHz, Limit at 1 nm = 0.1 μV/m = -20 dBμV/m) a) Radar Power: OFF b) Radar TX: O N -20 dBμV/m limit line Ref. level (dBμV/m) = 100 - 126 = -26 (at 0.5 MHz) = 100 - 96 = 4 (at 3 MHz) = 100 - 88 = 1 2 (at 5 MHz) Furuno Labotech International Report no.: FLI 12-03-031 - Page C .10 of 21 - (Band: 5 MHz - 10 MHz, Limit at 1 nm = 0.1 μV/m = -20 dBμV/m) a) Radar Power: OFF b) Radar TX: O N -20 dBμV/m limit line Ref. level (dBμV/m) = 100 - 88 = 12 (at 5 MHz) = 100 - 83 = 17 (at 7 MHz) = 100 - 78 = 22 (at 10 MHz) Furuno Labotech International Report no.: FLI 12-03-031 - Page C .11 of 21 - (Band: 10 MHz - 30 MHz, Limit at 1 nm = 0.1 μV/m = -20 dBμV/m) a) Radar Power: OFF b) Radar TX: O N -20 dBμV/m limit line Ref. level (dBμV/m) = 100 - 78 = 22 (at 10 MHz) = 100 - 70 = 30 (at 20 MHz) = 100 - 67 = 33 (at 30 MHz) Furuno Labotech International Report no.: FLI 12-03-031 - Page C .12 of 21 - (Band: 30 MHz - 100 MHz, Limit at 1 nm = 0.1 μV/m = -10.5 dBμV/m) a) Radar Power: OFF b) Radar TX: O N -10.5 dBμV/m limit line Ref. level (dBμV/m) = 100 - 61 = 3 9 Furuno Labotech International Report no.: FLI 12-03-031 - Page C .13 of 21 - (Band: 100 MHz - 300 MHz, Limit at 1 nm = 0.1 μV/m = -0 dBμV/m) a) Radar Power: OFF b) Radar TX: O N 0 dBμV/m limit line Ref. level (dBμV/m) = 100 - 60 = 4 0 Note: All components above the limit are from external noise or signals, not from Radar. Furuno Labotech International Report no.: FLI 12-03-031 - Page C .14 of 21 - (Band: 300 MHz - 1 GHz, Limit at 1 nm = 3 μV/m = -9.5 dBμV/m) a) Radar Power: …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 80 | 9.30 GHz - 9.50 GHz | 2200 W | 46M8PON | 30000.0000000000 Hz |
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine RadarTransceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar