www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders. Installation Manual RADAR SENSOR Model DRS2D-NXT/DRS4D-NXT (Product name: SOLID STATE DOPPLER RADAR) SAFETY INSTRUCTIONS ................................................................................................ i SYSTEM CONFIGURATION .......................................................................................... iii EQUIPMENT LISTS........................................................................................................ iv 1. INSTALLATION.......................................................................................................... 1 1.1 Installation Considerations.................................................................................................... 1 1.2 Installation of the Radar Sensor............................................................................................3 1.3 Wiring.................................................................................................................................... 7 2. INITIAL SETUP........................................................................................................... 8 2.1 Check Points After Installation ..............................................................................................8 2.2 Initial Setup ........................................................................................................................... 8 3. MAINTENANCE, TROUBLE- SHOOTING............................................................... 15 3.1 Maintenance ....................................................................................................................... 15 3.2 Replacement of Fuse..........................................................................................................15 3.3 Troubleshooting .................................................................................................................. 16 3.4 Life of Parts......................................................................................................................... 16 APPENDIX 1 RADIO REGULATORY INFORMATION ............................................ AP-1 SPECIFICATIONS ..................................................................................................... SP-1 OUTLINE DRAWINGS ................................................................................................ D-1 INTERCONNECTION DIAGRAMS.............................................................................. S-1 i SAFETY INSTRUCTIONS The installer of the equipment must read the safety instructions before attempting to install the equipment. Warning, Caution Prohibitive Action Mandatory Action Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar mast. ELECTRICAL SHOCK HAZARD Do not open the equipment. The installation does not require you to open the radar sensor. Be sure the power source is compatible with the voltage rating of the equipment. Connection of an incorrect power source can cause fire or damage the equipment. Turn off the power at the power source before beginning the installation. Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed. Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can result. Use the proper fuse. Use of a wrong fuse can damage the equipment or cause fire. Do not depend one navigation device for the navigation of the vessel. For the safety of vessel and crew, the navigator must check all aids available to confirm position. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. CAUTION WARNINGWARNING WARNING LABEL A warning label is attached to the antenna unit. Do not remove the label. If the label is missing or damaged, contact your dealer about replacement. Name: Warning Label (2) Type: 03-129-1001-3 Code No: 100-236-743 SAFETY INSTRUCTIONS ii Observe the following compass safe distances to prevent interference to a magnetic compass. The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar is in operation or expose yourself to the transmitting antenna at a close distance. Distances at which RF radiation levels of 100, 50 and 10 W/m 2 exist are given in the table below. 100W/m 2 10W/m 2 Model DRS2D-NXTN/A 50W/m 2 CAUTION Ground the equipment to prevent mutual interference. WARNING Do not use high-pressure cleaners to clean this equipment. This equipment has the waterproof rating outlined in the specifications, at the back of this manual. However, the use of high-pressure cleaning equipment can cause water ingress, resulting in damage to, or failure of, the equipment. DRS4D-NXTN/A0.7 m N/A N/A0.7 m Connect the sensor to a disconnecting device (circuit breaker, etc.) to control the power. Importer in Europe The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/EC. - Name: FURUNO EUROPE B.V. - Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands Importer in UK The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI 2019/470. - Name: FURUNO (UK) LTD. - Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K. Program No. 0359360-01.** ** denotes minor modifications. CE declaration With regards to CE declarations, please refer to our website (www.furuno.com), for further information about RoHS conformity declarations. Model DRS2D-NXT0.60 m DRS4D-NXT 0.30 m 0.55 m0.30 m Standard compass Steering compass Follow the instructions in thi…
Text truncated - open the document above for the full version.
4400 N.W. Pacific Rim Boulevard, Camas, Washington 98607-9408, U.S.A. Phone: +1 360-834-9300 Fax: +1 360-834-9400 www.furunousa.com 26, April 2021 TUV SUD BABT TCB/FCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Dear Sir or Madam, I, Shane Ryan of Furuno USA Inc , hereby authorize Akira Yamamoto and Hiroyasu Nakagawa of Furuno Electric Co., Ltd to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 26 April 2023. Sincerely, Company Officer: Shane Ryan Telephone Number: (360) 834-9300 X5060 Email: [email protected]
9-52 Ashihara-cho, Nishinomiya, 662-8580, Japan www.furuno.com 17 July 2021 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request FCC ID: ADB9ZWRTR133 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Furuno USA Inc hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation (Description of Circuitry and Devices) Furuno USA Inc also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Akira Yamamoto Telephone Number: +81(0)798-63-1216 Email: [email protected]
Labotech International Report no.: LIC 01-21-006 Date of issue: 31 March 2021 - Page 1 of 3 - Photographs of RADAR SENSOR, DRS2D-NXT 1 External view 1.1 Front view Labotech International Report no.: LIC 01-21-006 Date of issue: 31 March 2021 - Page 2 of 3 - 1.2 Rear view (showing labels) ID Label Labotech International Report no.: LIC 01-21-006 Date of issue: 31 March 2021 - Page 3 of 3 - 1.3 ID Label (Name plate)
Labotech International Document number: LIC 01-21-012 Date of issue: 31 March 2021 Form: Q053/01 - Page 1 of 1 - Identification of Equipment for RADAR SENSOR, DRS2D-NXT (FCC Rule, 2.925) 1 ID Label The following nameplate is permanently fixed on the corresponding equipment unit. FCC ID: ADB9ZWRTR133 Material of Nameplate: PET50S, 50 m thick 2 ID Label Location ID Label is affixed on the scanner case of RADAR SENSOR. End of text ID Label
Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 1 of 12 - Photographs of RADAR SENSOR, DRS2D-NXT 2 Internal View 2.1 Top view (with the top cover (radome) opened, showing Scanner module RSB-147 and Transceiver module RTR-133 including the radar antenna) Scanner module RSB-147 Radar antenna Transceiver module RTR-133 (inside RSB-147) Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 2 of 12 - 2.2 Top view Rotary Joint Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 3 of 12 - 2.3 Top view (with the radar antenna removed) Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 4 of 12 - 2.4 Top view (with Transceiver module removed) Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 5 of 12 - 2.5 Transceiver module (with the shield cover opened, showing PWR board 03P9613 and TRX module) TRX module PWR board Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 6 of 12 - 2.6 Transceiver module PWR board 03P9613 RU-9969 (Spurious Filter) Circulator Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 7 of 12 - 2.7 Transceiver module (with the shield cover opened, showing SPU board 03P9603 (upper) and PWR board 03P9613 (lower)) SPU board 03P9603 PWR board 03P9613 Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 8 of 12 - 2.8 Transceiver module (with PWR board 03P9613 removed) Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 9 of 12 - 2.9 Transceiver module (with SPU board 03P9603 removed) Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 10 of 12 - 2.10 TRX module Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 11 of 12 - 2.11 TRX module (with the shielding cover opened, showing TRX board 03P9602) TRX board 03P9602 Labotech International Report no.: LIC 01-21-007 Date of issue: 31 March 2021 - Page 12 of 12 - 2.12 TRX module (with TRX board 03P9602 remoed) End of text
This report shall not be reproduced except in full, without the written approval of Labotech International Co., Ltd. Test Report CFR Title 47 Sections: Part 2 (2.201, 2.202, 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055), Part 80 (80.209, 80.211, 80.213, 80.215, 80.273) for Trade name: Furuno Model: Transceiver for RADAR SENSOR DRS2D-NXT Type: RTR-133 Report no.: LIC 12-21-034 Rev. 1 Date of Revised Issue: 10 September 2021 Labotech International Co., Ltd. 1-16, Fukazu-cho, Nishinomiya-shi, Hyogo, 663-8203 Japan Tel: +81-798-63-1094 Fax: +81-798-63-1098 URL: https://www.labotech-intl.co.jp// Labotech International Report no.: LIC 12-21-034, Rev. 1 Form: LQ053/10 - Page 2 of 65 - Report Summary LIC project number: LIC 04-20-0633 Test report number of initial issue: LIC 12-21-034 Date of initial issue 31 March 2021 Test report number of revised/replaced issue: LIC 12-21-034, Rev.1 Date of revised/replaced issue 10 September 2021 Test report revision/ replacement history: Rev. No Date Page Item Description of change/reason 1 10 Sep. 2021 17 3.5 Spurious Emissions at Antenna Port, 3.5.5 Test Results Replaced the table with another table of measured maximum emission values. 42 7 Spurious Emission Plots measured at Antenna Terminal Added plots of spurious emissions and divided Clause 7 into 7.1 and 7.2. 63 8 Field Strength of Spurious Radiation Plots measured in the Spurious domain Added Clause 8. Test standard(s)/ Test specifications: CFR Title 47 Sections: 2.201 - Emission, modulation, and transmission characteristics 2.202 - Bandwidths 2.1046 - RF Power Output 2.1047 - Measurements required: Modulation Characteristics 2.1049 - Occupied Bandwidth 2.1051 - Spurious Emissions at Antenna Terminals 2.1053 - Field Strength of Spurious Radiation 2.1055 - Measurements required: Frequency Stability 80.209 - Transmitter frequency tolerances 80.211 - Emission limitations 80.213 - Modulation requirements 80.215 - Transmitter power 80.273 - Radar standards (the latest version on the first day of the testing period) Customer: Furuno Electric Co., Ltd. 9-52 Ashihara-cho, Nishinomiya city, Hyogo, 662-8580 Japan Manufacturer: Furuno Electric Co., Ltd. 9-52 Ashihara-cho, Nishinomiya city, Hyogo, 662-8580 Japan Trade name: Furuno Model: Transceiver for RADAR SENSOR DRS2D-NXT Type: RTR-133 Product function and intended use: Marine Radar operating in the band of 9300-9500 MHz Number of samples tested: One Serial number: 1001-3600-0001 Power rating: 12–24 VDC, 2.5–1.3 A Modifications made to samples during testing: None Date of receipt of samples: 18 November 2020 Test period: From 19 January 2021 to 1 March 2021 Labotech International Report no.: LIC 12-21-034, Rev. 1 Form: LQ053/10 - Page 3 of 65 - Place of test: Labotech International Co., Ltd. FCC Test firm Designation Number: JP2007 FCC Test firm Registration Number: 838049 - LABOTECH EMC Center 1-16 Fukazu-cho, Nishinomiya-shi, Hyogo, 663-8203 Japan - Nishinomiya Lab. 9-52 Ashihara-cho, Nishinomiya-shi, Hyogo, 662-8580 Japan Test results/Compliance: Passed. The test results of this report relate only to the samples tested. Tested by: Yukihiro Hijiri and Atsushi Takagi Written by: Arisa Ogino Verified by: Tadayuki Ekawa Approved by: Date: 10 September 2021 Name: Tadayuki Ekawa Title: Head engineer, Technical Department Labotech International Co., Ltd. Signature: Disclaimer: The test results of this report relate only to the samples tested. LIC has no responsibility for the followings except for the requirements of test standards. The thing(s) in association with the test and information pertaining to it/them, which are provided by the customer; information described in Clause 1 (except for (h)) of this report and information of the cable(s) used. The matter(s) specified by the customer; Test standard(s) applied, test item(s), test conditions, criteria, object(s) to be tested or excluded, operation mode(s) and connection/configuration. Labotech International Report no.: LIC 12-21-034, Rev. 1 Form: LQ053/10 - Page 4 of 65 - Testing Laboratory Status Labotech International Co., Ltd. (hereafter called “LIC”) has been holding the following status after having been assessed according to the provisions of ISO/IEC 17025 and/or the relevant rules: (1) JAB Accredited Testing Laboratory: - accredited by Japan Accreditation Board (JAB) - Laboratory accreditation number: RTL03220 (Date of initial accreditation: 14 January 2011 (*)) - Scope of accreditation: Electrical testing - EMC, Climatic, Vibration and Radio tests (2) Telefication Listed Testing Laboratory: - listed by Telefication B. V., (The Netherlands) - Laboratory assignment number: L116 (Date of initial listing: 26 July 1999 (*)) - for testing the following product categories/ test standards: EN 60945, IEC 61162-1/-2, IEC/EN 61162-450, IEC 62288, ETSI EN 301 843-1 / -2, ETSI EN 301 489-1 / -3 / -17 (3) TÜV Appointed EMC Test Laboratory: - appointed by TÜV Rheinland Japan Ltd., - Laboratory assignment number: UA 50046428 (Date of initial appointment: 21 December 1998 (*)) - for carrying out the tests of EMC emission and immunity (4) RMRS Recognized Testing Laboratory: - recognized by Russian Maritime Register of Shipping (Russia) - Laboratory recognition number: 17.13259.170 (Date of initial recognition: 27 January 2009 (*)) - for carrying out testing in the field of: Electrical measurements and tests, EMC tests, Mechanical measurements and tests, Equipment protection degree tests, and Climatic tests for Ship’s radio and navigational equipment and IEC 60945: 2002 (5) RRR Recognized Test Laboratory: - recognized by Russian River Register (Russia) - Certificate number: 131927 (- Date of initial recognition: 31 May 2013 (*)) - for carrying out of tests of ships radio and navigation equipment (6) DNV GL Recognized Environmental Test Laboratory: - recognized by Det Norske Veritas AS, Germanischer Lloyd (Norway) - Recognition certificate number: 262.1-015854-J-12 (Date of initial recognition: 12 July 2013 (*)) -…
Text truncated - open the document above for the full version.
Labotech International Report no.: LIC 12-21-034 Form: LQ053/10 - Page 1 of 1 - Photograph of Test Setup/Arrangement (1) For RF Power Output, Modulation Characteristics, Frequency Stability –temperature & voltage, Occupied Bandwidth and Spurious Emissions at Antenna Port Note: For the test of “Spurious Emissions at Antenna Port”, the test was conducted with the EUT outside the climatic chamber. (2) For Field Strength of Spurious Radiation End of text
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 8 | 9.40 GHz - 9.44 GHz | 25 W | 19M3Q0N | 1250 ppm |
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine RadarTransceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Transceiver unit for the radar sensor
Equipment Class
MRD - Marine Radar
Class B AIS Transponder
Equipment Class
AIS - Automatic Identification Systems