ADB9ZWRTR136Transceiver unit for the radar sensor

Furuno USA Inc

Application Details

Equipment Class
MRD - Marine Radar
Date of Grant
Jul 01, 2024
Application Purpose
Original Equipment
Date of Application
Jul 01, 2024
Equipment Note
Transceiver unit for the radar sensor
Frequency Range
9380.00000000 - 9440.00000000
Company
Furuno USA Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-17-2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: ADB9ZWRTR136 Furuno USA Inc certifies that, as of the date of the filing of the application, Furuno USA Inc is our designated U.S. agent for service of process for the above referenced FCC ID. Furuno USA Inc accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Furuno USA Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC IDs. Designated U.S. Agent Information: Name: Furuno USA Inc Address: 4400 NW Pacific Rim Blvd. Contact Person: William Haynes Tel.: 360-833-5047 Email: [email protected] FRN:0005903604 Sincerely, [Insert U.S. agent company name]Furuno USA Inc (U.S. agent company nameprinted name)Furuno USA Inc (U.S. agent company name signature) [Insert applicant name]Furuno USA Inc (Applicant printed name)William Haynes (Applicant signature)

Attestation Statements

Date: 06-17-2024 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: ADB9ZWRTR136 Dear Sir or Madam, Furuno USA Inc certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that,as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please contact us. Sincerely, Contact name: William Haynes Company name:Furuno USA Inc Address: 4400 NW Pacific Rim Blvd. Camas, WA 98607 E-mail: [email protected] Tel: 360-833-5047

Cover Letter(s)

9-52 Ashihara-cho, Nishinomiya, 662-8580, Japan www.furuno.com 17 June 2024 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request FCC ID: ADB9ZWRTR136 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Furuno USA Inc hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation (Description of Circuitry and Devices) Furuno USA Inc also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of 180 days: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Akira Yamamoto Telephone Number: +81(0)798-63-1216 Email: [email protected]

Cover Letter(s)

06 June 2023 TUV SUD BABT TCB/FCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Dear Sir or Madam, I, Bill Haynes of Furuno USA Inc , hereby authorize Akira Yamamoto of Furuno Electric Co., Ltd to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on 01 July 2026. Sincerely, Bill Haynes Deep Sea Product Manager, Furuno USA Signature_______________________ Date Signed – 06 June 2023

ID Label/Location Info

Labotech International Document number: LIC 01-24-026 Date of issue: 17 May 2024 Form: Q053/01 - Page 1 of 1 - Identification of Equipment for Radar Sensor, Transceiver RTR-136 (FCC Rule, 2.925) 1 ID Label The following nameplate is permanently fixed on the corresponding equipment unit. FCC ID: ADB9ZWRTR136 Material of Nameplate: PET50S, 75 m thick 2 ID Label Location ID Label is affixed to the base part. End of text ID Label

RF Exposure Info

RF Exposure Evaluation Report 1. Product Information ManufacturerFuruno Electric Co., Ltd. 9-52 Ashihara-cho, Nishinomiya city, Hyogo, 662-8580 Japan Trade nameFuruno TypeRTR-136 ModelTransceiver for RADAR SENSOR DRS4DL X-Class Product DescriptionShip radar station operating in the band 9300–9500 MHz FCC IDADB9ZWRTR136 Frequency Range9380MHz ~ 9440MHz Peak Envelope Power (PEP)4kW Antenna Gain (G p )21.5dBi Beam Width (θ)5.2° Maximum Pulse Width (τ) 0.8μs Pulse Repetition Frequency (PRF) 360Hz Minimum separation distance0.73m 2. Evaluation method and Limit FCC requirements According to FCC CFR 47 part1 1.1307 (b)(3)(i)(C): The criteria listed in the following table shall be used to determine the exemption of further evaluation. R is the separation distance and is 0.73m instructed in the installation manual. Threshold ERP * is ERP TH = 19.2 × 0.73 2 = 10.23 [W] * ERP: refer to FCC CFR 47 part1 1.1307 (b)(2) 3. Evaluation Results Calculated ERP ERP = PEP × 10^ቆ G p −2.15 10 ቇ× ( τ× PRF ) × θ 360 ERP = 4000 × 10^൬ 21.5−2.15 10 ൰× ( 0.8 × 10 −6 × 360 ) × 5.2 360 = 1.43 [ W ] ≤10.23 [ W ] where: PEP is converted to the mean power using the pulse width and the pulse repetition frequency. G p is converted to a gain relative to a dipole. The antenna rotates continuously over 360 degrees in the horizontal plane and illuminates the subjects only by its main lobe. Therefore, time-averaged power is derated by the beamwidth and the angle of rotation.

Test Report

This report shall not be reproduced except in full, without the written approval of Labotech International Co., Ltd. Test Report CFR Title 47 Sections: Part 2 (2.201, 2.202, 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055) Part 80 (80.209, 80.211, 80.213, 80.215, 80.273) Trade Name : FURUNO Model : Transceiver for Radar Sensor DRS4DL X-Class Type : RTR-136 Report Number : LIC 12-24-043 Date of Issue : 17 May 2024 Labotech International Co., Ltd. 1-16, Fukazu-cho, Nishinomiya-shi, Hyogo, 663-8203 Japan Tel: +81 (0) 798 63 1094 Fax: +81 (0) 798 63 1098 URL: https://www.labotech-intl.co.jp/ Labotech International Report no.: LIC 12-24-043 Form: LQ053/12 - Page 2 of 29 - Table of contents Testing Laboratory Status.................................................................................................................................. 3 1 Report Summary ............................................................................................................................................. 4 2 Principal Information ....................................................................................................................................... 6 3 Test Results Summary ................................................................................................................................... 9 4 Test Results .................................................................................................................................................. 10 4.1 RF Power Output ................................................................................................................................... 10 4.2 Modulation Characteristics .................................................................................................................... 10 4.3 Frequency Stability –temperature & voltage .......................................................................................... 11 4.4 Occupied Bandwidth .............................................................................................................................. 12 4.5 Spurious Emissions at Antenna Terminals ............................................................................................ 13 4.6 Field Strength of Spurious Radiation ..................................................................................................... 14 5 Test Setup for Measurements ...................................................................................................................... 16 6 Measuring Equipment List ............................................................................................................................ 19 7 RF Envelope and Spectrum of the Output Pulse ......................................................................................... 21 8 Spurious Emission Plots measured at Antenna Terminal ............................................................................ 23 9 Field Strength of Spurious Radiation Plots measured in the Spurious domain............................................ 27 Labotech International Report no.: LIC 12-24-043 Form: LQ053/12 - Page 3 of 29 - Testing Laboratory Status Labotech International Co., Ltd. (hereafter called “LI C ”) has been holding the following status after having been assessed according to the provisions of ISO/IEC 17025 and/or the relevant rules : (1) JAB Accredited Testing Laboratory: - accredited by Japan Accreditation Board (JAB) - Laboratory accreditation number: RTL03220 ( Date of initial accreditation: 14 January 2011 (*) ) - Scope of accreditation: Electrical testing - EMC, Climatic, Vibration and Radio tests (2) Kiwa Listed Testing Laboratory: - listed by Kiwa Netherlands B.V. , (The Netherlands) - Laboratory assignment number: L116 ( Date of initial listing : 26 July 1999 (*) ) - for testing the following product categories/ test standards: EN 60945, IEC 61162 - 1/ - 2, IEC/EN 61162 - 450, IEC 62288 , ETSI EN 301 843 - 1 / - 2, ETSI EN 301 489 - 1 / - 3 / - 17 ( 3 ) TÜV Appointed EMC Test Laboratory: - appoin ted by TÜV Rheinland Japan Ltd. - Laboratory assignment number: UA 50046428 ( Date of initial appointment : 21 December 1998 (*) ) - for carrying out the tests o f EMC emission and immunity ( 4 ) RMRS Recognized Testing Laboratory: - recognized by Russian Marit ime Register of Shipping (Russia) - Laboratory recognition number: 17.13259.170 ( Date of initial recognition: 27 January 2009 (*) ) - for carrying out testing in the field of: Electrical measurements and tests, EMC tests, Mechanical measurements and tests, Equipment protection degree tests, and Climatic tests for Ship ’ s radio and navigational equipment and IEC 60945: 2002 ( 5 ) DNV Recognized Environmental Test Laboratory: - recognized by Det Norske Veritas AS - Recognition certificate number: 262.1 - 015854 - J - 12 ( Date of initial recognition: 12 July 2013 (*) ) - Scope of recognition: Testing according to the standards IEC 60945, IEC 61162 - 1/ - 2/ - 450, IEC 62288, IEC 62388 and IEC 62252 Annex E - Application: Provisi ons of Environmental , interface and safety testing ( 6 ) CCS Recognized Test Agency: - recognized by China Classification Society - Recognition certificate number: DB21PAA00001 ( Date of initial recognition: 29 January 2014 (*) ) - Scope of recognition: Performance/Environmental/EMC/Special purpose/Safety precautions tests for Electrical & Electronic Product including Maritime Navigation and Radio - communication Equipment & Systems ( 7 ) SABS EMC A - Lab program Laboratory: - recognized by South African Bureau of Standards - Assigned Lab number: SABS/A - LAB/0042/2018 ( Date of initial recognition : 5 Ju l y 201 8 (*) ) - Approved List of EMC Standards : SANS 211 / 214 - 1 / 214 - 2 / 222 / 2332 / 2335, CISPR 11 / 14 - 1 / 14 - 2 / 22 / 32 / 35, SANS/IEC 60601 - 1 - 2, SANS/IEC 61326 - 1, IEC 61326 - 2 - 6, SANS/IEC 61000 - 3 - 2 / - 3 - 3 / - 4 - 2 / - 4 - 3 / - 4 - 4 / - 4 - 5 / - 4 - 6 / - 4 - 8 / - 4 - …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bill Haynes(Deep Sea Product Manager)
[email protected]888-834-9330Fax: 360-833-5195

Test Firm

Labotech International Co.,Ltd Labotech EMC CenterFumiya Ueki
[email protected]+81-798-63-1094Fax: +81-798-63-1098

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1809.38 GHz - 9.44 GHz4000 W43M2P0N0.3000000000 %
Confidentiality
Long Term
Grant Notes
Power listed is Rated conducted Output Power. The device and its antenna(s) must be installed to provide a separation distance of at least 0.73 meter from all persons. Installers and end-users must be provided with operating conditions for satisfying RF exposure compliance.

Other Applications from Furuno USA Inc

ADB-9ZWRTR137

Transceiver unit for the radar sensor

Feb 18, 2026

Equipment Class

MRD - Marine Radar
Transceiver unit for the radar sensor - FCC ID ADB9ZWRTR128 - Furuno USA Inc
ADB9ZWRTR128

Transceiver unit for the radar sensor

Apr 06, 2022

Equipment Class

MRD - Marine Radar
Transceiver unit for the radar sensor - FCC ID ADB9ZWRTR133 - Furuno USA Inc
ADB9ZWRTR133

Transceiver unit for the radar sensor

Sep 26, 2021

Equipment Class

MRD - Marine Radar
Transceiver unit for the radar sensor - FCC ID ADB9ZWRTR129 - Furuno USA Inc
ADB9ZWRTR129

Transceiver unit for the radar sensor

May 23, 2021

Equipment Class

MRD - Marine Radar
Class B AIS Transponder - FCC ID ADB9ZWFA70 - Furuno USA Inc
ADB9ZWFA70

Class B AIS Transponder

May 18, 2020

Equipment Class

AIS - Automatic Identification Systems