Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 12 | 90.21 | 400 MHz - 470 MHz | 1 W | 4K00F1D | 1
ppm |
Grant NotesPower Output listed is Conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the ccupational/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, antennas and accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Face Held: 1.58W/kg for 50% Duty Cycle; Body Worn: 5.27W/kg for 50% Duty Cycle.