
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
S:\TimcoOffice\ReportTemplate\probonholdemail.doc TIMCO TIMCOTIMCO TIMCO ENGINEERING INC. 849 NW State Road 45 Newberry, Florida 32669 http://www.timcoengr.com 888.472.2424 F 352.472.2030 email: tei@t imcoengr.com 16 February 2001 FCC SUBJECT: MITSUBISHI ELECTRIC CORPORATION FCC ID: BGBHS-U747 TO WHOM IT MAY CONCERN, We had questions for this applicant about the levels of the sidebands and their response is attached below. It appears to be properly justified. Our questions were as follows; On page 29 of 36 of the test report with the EUT on Channel 3 the test report states an emission at 56.65MHz of a level of 42.8dBuV with a limit of 39.5dBuV, please explain. On page 29 of 36 of the test report with the EUT on Channel 4 the test report states an emission at 62.65MHz of a level of 43.6dBuV with a limit of 39.5dBuV, please explain. Sincerely, Sid Sanders DateFeb.14, 2001 ToTIMCO Engineering Inc. Fax#+1 352.472.2030 Dear Sid Sanders-SAN Form Letters3 FromF. Nagaoka/ Ikoma Testing Lab/KEC Fax#+81 743.79.1014 SUBJECTMITSUBISHI ELECTRIC Corp. FCC ID:BGBHS-U747 We have received your FAX letter(Ref.JOB#:91J1) for FCC ID:BGBHS- U747“MITSUBISHI”on February 13, 2001. We consider that you point out the level data of 56.65MHz at the Test Channel #3 and 62.65MHz at the Test Channel #4 with the bandwidth of 100kHz exceed the limit regarding the test results of “Output Terminal Conducted Spurious Emission Measurement” on the page 29 of the test report (A-051-00-C). Our view of the subject is as follows. The measured frequency in “Output Terminal Conducted Spurious Emission Measurement” is –4.6MHz or less or +7.4MHz or over from the Visual carrier frequency. The ranges of the measured frequency at the Test Channel #3 are 30MHz to 56.65MHz and 65.75MHz to 1000MHz. When the image of the Aural carrier frequency is 56.75MHz, the level data of the measuring boundary frequency, 56.65MHz depend on the image of the Aural carrier frequency and the characteristics of the IF Filter of the spectrum analyzer. Therefore, when measuring the level of the measuring boundary frequency of 56.65MHz, the level data with the IF Filter band width of 30kHz reduced from 100k Hz are also mentioned to show that the center frequency of the image of the Aural carrier frequency is out of the measurement bandwidth. The level data of 14.7dBV at **56.65MHz and 17.7dBV at **62.65MHz with IF Filter of 30kHz are mentioned on the page 29 of the test report (A-051-00-C). The level data are decreased considerably by reducing the IF Filter band width to 30kHz from 100k Hz showing that the center frequency is out of the measurement range. Therefore, we conclude there is no problem about the results. Vi s ua l Car ii er Aural Cariier Image -4.6MHz +7.4MHz Form Letters3 Please refer to [ Note ] (1) in the page 29.of Test Report #A-051-00-C. We have reported this subject using the same means of measurement and we consider that FCC understands it. [Reference : 1.Ref.Standard ANSI C63.4-1992 Section 12.2.5 and Appendix H. 2.See the FCC Labs engineer Mr.George Tannahill ] If you have any questions, please do not hesitate to contact us. Best regards, Fumitoshi Nagaoka Associate Director Ikoma Testing Lab./KEC e-mail:[email protected]
HS-U747 FCC ID : BGB HS-U747 WHOLE-VIEW HS-U747 FCC ID : BGB HS-U747 FORNT-VIEW HS-U747 FCC ID : BGB HS-U747 REAR-VIEW HS-U747 FCC ID : BGB HS-U747 NAME-PLATE HS-U747 FCC ID : BGB HS-U747 INSIDE
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN FCC ID:BGBHS-U747 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. HS-U747 VIDEO CASSETTE RECORDER DISTRIBUTED BY Mitsubishi Digital Electronics America, Inc. 9351 Jeronimo Road Irvine, CA 92618-1904 MADE IN MALAYSIA MODEL AC120V 60Hz 21W PART No. 776C204B5
HS-U747 FCC ID : BGB HS-U747 REAR-VIEW
HS-U747 FCC ID : BGB HS-U747 PCB-OPE COMPONENT-SIDE HS-U747 FCC ID : BGB HS-U747 PCB-OPE COPPER-SIDE HS-U747 FCC ID : BGB HS-U747 RF MODULATOR COMPONENT-SIDE HS-U747 FCC ID : BGB HS-U747 RF MODULATOR COPPER-SIDE HS-U747 FCC ID : BGB HS-U747 RF MODULATOR INSIDE OF COMPONENT-SIDE HS-U747 FCC ID : BGB HS-U747 RF MODULATOR INSIDE OF COPPER-SIDE
HS-U747 FCC ID : BGB HS-U747 PCB-MAIN COMPONENT-SIDE
HS-U747 FCC ID : BGB HS-U747 PCB-MAIN COPPER-SIDE
A-051-00-C Page 1 of 36 KEC Ikoma Testing Laboratory 12128 Takayama-cho Ikoma-city Nara 630-0101 Japan Designated by Ministry of international Trade and industry KANSAI ELECTRONIC INDUSTRY DEVELOPMENT CENTER HEAD OFFICE IKOMA TESTING LABORATORY 6-8-7 NISHITENMA 12128 TAKAYAMA-CHO KITA-KU OSAKA 530-0047 JAPAN IKOMA-CITY NARA 630-0101 JAPAN Corporate Juridical Person TEST REPORT Report No.A-051-00-C Date: 9 January 2001 This test report is to certify that the tested device properly complies with the requirements of: FCC Rules and Regulations Part 15 Subpart B Unintentional Radiators. All the tests necessary to show compliance to the requirements were performed and these results met the specifications of requirement. The results of this report should not be construed to imply compliance of equipment other than that, which was tested. Unless the laboratory permission, this report should not be copied in part. 1. Applicant Company Name : MITSUBISHI ELECTRIC CORP. Kyoto Works Imaging Storage Products Department Mailing Address : 1 Baba-Zusyo Nagaokakyo-City Kyoto 617-8550 Japan 2. Identification of Tested Device Type of Device : TV Interface Device Kind of Equipment Authorization : : DoC : Certification : Verification FCC ID : BGBHS-U747 Device Name : Video Cassette Recorder (Test for RF Modulator) Trade Name : MITSUBISHI Model Number : HS-U747 Serial Number : P005 : Prototype : Pre-production : Production Date of Manufacture : November 2000 3. Test Items and Procedure : AC Power Line Conducted Emission Measurement : Radiated Emission Measurement : Output Signal Level Measurement : Output Terminal Conducted Spurious Emission Measurement : Transfer Switch Measurement Above all tests were performed under: ANSI C63.4 – 1992 : without deviation, : with deviation(details are found inside of this report) 4. Date of Test Receipt of Test Sample : 4 December 2000 Test Completed on : 21 December 2000 Fumitoshi Nagaoka Associate Director/ Ikoma Testing Laboratory A-051-00-C Page 2 of 36 KEC Ikoma Testing Laboratory 12128 Takayama-cho Ikoma-city Nara 630-0101 Japan Table of Contents 0. NVLAP ACCREDITATION AND MEASUREMENT UNCERTAINTY.......................3 0.1. NVLAP Accreditation.........................................................................................3 0.2. Measurement Uncertainty.................................................................................3 1. CERTIFICATION OF THE COMPLIANCE..............................................................3 2. GENERAL INFORMATION.....................................................................................4 2.1. Product Description...........................................................................................4 2.2. Description for Equipment Authorization...........................................................5 2.3. Test Facility.......................................................................................................5 3. TESTED SYSTEM....................................................................................................6 3.1. Test Mode..........................................................................................................6 3.2. Operation of EUT System..................................................................................7 3.3. Characterization and condition of EUT System..................................................7 3.4. Block Diagram of EUT System..........................................................................8 4. AC POWER LINE CONDUCTED EMISSION MEASUREMENT...........................12 4.1. Test Procedure.................................................................................................12 4.2. Test Results.....................................................................................................13 4.3. Photographs of EUT System Configuration......................................................14 5. RADIATED EMISSION MEASUREMENT.............................................................18 5.1. Test Procedure.................................................................................................18 5.2. Test Results.....................................................................................................19 5.3. Photographs of EUT System Configuration......................................................20 6. OUTPUT SIGNAL LEVEL MEASUREMENT........................................................24 6.1. Test Procedure.................................................................................................24 6.2. Test Results.....................................................................................................25 6.3. Photographs of EUT System Configuration......................................................26 7. OUTPUT TERMINAL CONDUCTED SOURIOUS EMISSION MEASUREMENT..28 7.1. Test Procedure.................................................................................................28 7.2. Test Results.....................................................................................................29 7.3. Photographs of EUT System Configuration......................................................30 8. TRANSFER SWITCH MEASUREMENT................................................................31 8.1. Test Procedure.................................................................................................31 8.2. Test Results.....................................................................................................32 8.3. Photographs of EUT System Configuration......................................................33 9. USED TEST EQUIPMENTS AND CALIBRATION STATUS..................................35 A-051-00-C Page 3 of 36 KEC Ikoma Testing Laboratory 12128 Takayama-cho Ikoma-city Nara 630-0101 Japan 0. NVLAP ACCREDITATION AND MEASUREMENT UNCERTAINTY 0.1. NVLAP Accreditation KEC is accredited by the National Voluntary Accreditation Program for the specific scope of…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 60 MHz - 72 MHz | - |

Digital Color Printer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Digital Color Printer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Digital Color Printer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
GSM/WCDMA Mobile Phone with NFC Function
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart Keyless System (ECU)
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter