Application Details

Equipment Class
HID - Part 15 TV Interface Device
Date of Grant
May 05, 2004
Application Purpose
Original Equipment
Date of Application
May 05, 2004
Equipment Note
VCR With DVD Player
Frequency Range
62.74000000 - 71.81000000
Company
WINIA Electronics Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PRODUCT INFORMATION 1 IMPORTANTSAFEGUARDS CAUTION:TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and servicing instructions in the literature accompanying the appliance. WARNINGTO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTIONTO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. IMPORTANT FOR LASER PRODUCTS LASERThis Digital Video Disc Player employs a Laser System. To ensure proper use of this product please read this owner’s manual carefully and retain for future reference. Should the unit require maintenance, contact an authorized service location - see service procedure. Use of control adjustments or the performance of procedures other than those specified may result in hazardous radiation exposure. To prevent direct exposure to the laser beam, do not try to open the enclosure. Visible laser radiation when open and interlocks defeated. DO NOT STARE INTO THE BEAM. DANGERVisible laser radiation when open and interlock failed or defeated. Avoid direct exposure to beam. CAUTIONDo not open the top cover. There are no user serviceable parts inside the Unit; leave all servicing to qualified service personnel. CLASS 1 LASER PRODUCT FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rule. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception; which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experience radio/TV technical for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. CAUTIONAny changes or modification in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2 This set has been designed and manufactured to assure personal safety. Improper use can result in electric shock or fire hazard. The safeguards incorporated in this unit will protect you if you observe the following procedures for installation, use and servicing. This unit is fully transistorized and does not contain any parts that can be repaired by the user. 1 Read Instructions All the safety and operating instructions should be read before the unit is operated. 2 Retain Instructions The safety and operating instructions should be retained for future reference. 3 Heed Warnings All warnings on the unit and in the operating instructions should be adhered to. 4 Follow Instructions All operating and use instructions should be followed. 5 Cleaning Unplug this unit from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 6 Attachments Do not use attachments unless recommended by the unit’s manufacturer as they may cause hazards. 7 Water and Moisture Do not use this unit near water- for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement, or near a swimming pool and the like. Caution : Maintain electrical safety. Powerline operated equipment or accessories connected to this unit should bear the UL listing mark or CSA certification mark on the accessory itself and should not be modified so as to defeat the safety features. This will help avoid any potential hazard from electrical shock or fire. If in doubt, contact qualified service personnel. 8 Accessories Do not place this unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious injury to a child or adult as well as serious damage to the unit. Use this unit only with a cart, stand, tripod, bracket, or table recommended by the manufacturer. 8AA unit and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the unit and cart combination to overturn. 9 Ventilation Slots and openings in the case are provided for ventilation to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. These openings must not be blocked by placing the unit on a bed, sofa, rug, or other similar surface. This unit should never be placed near or over a radiator or heat radiator. This unit should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to. 10 Power Sources This unit should be operated only from the type of power source indicated on the marking label. If you are not s…

Text truncated - open the document above for the full version.

Block Diagram

DVD BLOCK DIAGRAM DVD MPEG PAR T Digita Data (Video) Control Data ATAPI Interface ControlDigital SiganlDigitalAudio Data InterfaceVideo Data Analog Video out VCR PART LOADE R Ass'y MICOM MPEG DECODER VIDEO ENCODER (Component, Composite) FLASH MEMORY SDRAM Hi_Fi IC (AN3663) Switching Block INPUT (L/R)(L/R) DVD BSBsmon (3/1) OUTPUT Record Field HI_FI (57/53) EXT3 (4/2) LINE2 EXT2 (14/9) LINE1 EXT1 (15/10) MTS Hi_Fi IC (AN3663)

External Photos

IST Co., Ltd. EMC LABORATORY External Photos.Ref.No : 04-IST-0066 1 of 3 The DUT photos Front View Rear View IST Co., Ltd. EMC LABORATORY External Photos.Ref.No : 04-IST-0066 2 of 3 The DUT photos Side View Side View IST Co., Ltd. EMC LABORATORY External Photos.Ref.No : 04-IST-0066 3 of 3 The DUT photos Bottom View

ID Label/Location Info

IST Co., Ltd. EMC LABORATORY Label Location.Ref.No : 04-IST-0066 1 of 1 Label Sample Label Location Label Location

Internal Photos

IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 1 of 15 The DUT photos Inner Top View Inner Top View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 2 of 15 The DUT photos VCR Deck Top View VCR Deck Bottom View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 3 of 15 The DUT photos Main Board PCB Parts View Main Board PCB Copper View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 4 of 15 The DUT photos DVD Deck Top View DVD Deck Bottom View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 5 of 15 The DUT photos Power Board PCB Parts View Power Board PCB Copper View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 6 of 15 The DUT photos AUX front Input Panel PCB Parts View AUX front Input Panel PCB Copper View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 7 of 15 The DUT photos Top Cover Inner Bottom/Inner Front IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 8 of 15 Tuner photos(TADM-H101F) Front View Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 9 of 15 Tuner photos(TADM-H101F) Inner Front View Inner Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 10 of 15 Tuner photos(TADM-H201F) Front View Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 11 of 15 Tuner photos(TADM-H201F) Inner Front View Inner Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 12 of 15 Tuner photos(TCMN0682PA20B4) Front View Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 13 of 15 Tuner photos(TCMN0682PA20B4) Inner Front View Inner Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 14 of 15 Tuner photos(TMZH2-030A) Front View Rear View IST Co., Ltd. EMC LABORATORY Internal Photos. Ref.No: 04-IST-0066 15 of 15 Tuner photos(TMZH2-030A) Inner Front View Inner Rear View

Parts List/Tune Up Info

            ! "#$%  & '()!  !*+ ,$ ! ! "*% ) (-( -*. $ ! ( *  --&&)(' -* &$ ,$ &&! ( +# $ --(' -* &$ ,$ ! ( +#  -/.#0'  -* $ - #  +# # )) +  ))! "#$%  0 '()!  !*+ ,$ ! ! "*%   )$ !  ! $  +  ! ! "$%  & (-( -*. $ ! ( * & (-( -*. $ ! ( * &)    ! "#$%  &    ! "#$%  )    ! "#$%  )$    ! "#$%  )+    ! "#$%  )  +  ! ! "$%  )0 #$#+1* +$&!! * 2 & -'.).' -* $  ! . +# && && +  ! &&! "$% &) -'.&&&.' -* $  && . +# & -'.&&.' -* $  & . +# &+ && +  ! &&! "$% &# && +  ! &&! "$% &0 --(' -* &$ ,$ ! ( +# & && +  ! &&! "$% && -0 $  ! !  &+ -/.#&3' -* $ - #& 3 +# & --(' -* &$ ,$ ! ( +# &0 !!&&)3 !, &! 3 "% && -'.).' -* $  ! . +# &&& -'.))).' -* $  ))! . +# &&) -0 $  ! !  &&#  +  ! ! "$%  &$  +  ! ! $ &$ (-( -*. $ ! ( * &$&  +  ! ! $ &$) -0 $  ! !  &$  +  ! ! $ &$$ -0 $  ! !  &$+ - $  ! ! "$%  &$ )) +  ! ))! "+)%  &$#  +  ! ! $ &$0 && +  ! &&! "$% &+ .'-$). -*'. $ $! .  &+ &+ '()!  !*+ ,$ ! ! "*% &+& -'.).' -* $  ! . +# &+) -'.).' -* $  ! . +# &+ (-( -*. $ ! ( * &+$ -'.).' -* $  ! . +# &++ -&&# $  ! &&! "% &+ .'-$). -*'. $ $! .  &+ &+# && +  ! &&! "$% &+0  +  ! ! $ & )) +  ! ))! "+)%  & -'.).' -* $  ! . +# && 3&&  +)   &&! +) &) -0 $  ! !  & (-)( $  ! ( &$ -))0 $  ! ))!  &+ --(' -* &$ ,$ ! ( +# & --(' -* &$ ,$ ! ( +# &# --(' -* &$ ,$ ! ( +# &0  +  ! ! $ &# -&&0 $  ! &&! "%  &#& --(' -* &$ ,$ ! ( +# &#) --(' -* &$ ,$ ! ( +# &#  +  ! ! $ &#$ '()!  !*+ ,$ ! ! "*% &#+  +  ! ! "$%  &# --(' -* &$ ,$ ! ( +# &## && +  ! &&! "$% &#0  +  ! ! $ &0 (-( -*. $ ! ( * &0& -'.&&).' -* $  &&! . +# &0) -))0 $  ! ))!  &0 (-( -*. $ ! ( * &0$  +  ! ! $ &0$2  +  ! ! $ &0+  +  ! ! $ &0+2  +  ! ! $ &0  &$  ! ! +)4 &00 (-( -*. $ ! ( * ) -0 $  ! ! "%  )& ('-)0. $ ' )0 . "*% )) (-( -*. $ ! ( * ) -/.#3' -* $ - # 3 +# )$ -0 $  ! ! "%  )+  +  ! ! "$%  ) -'.).' -* $  ! . +# )# && +  ! &&! "$% )0  +  ! ! $ ) -0 $  ! ! "%  )  +  ! ! $ )& --(' -* &$ ,$ ! ( +# ))  +  ! ! $ )  +  ! ! $ )$ -0 $  ! ! "%  )+ -0 $  ! ! "%  ) -0 $  ! ! "%  )# '()!  !*+ ,$ ! ! "*% )0 -'.).' -* $  ! . +# )& -'.).' -* $  ! . +# )&  +  ! ! "$%  )&& -'.).' -* $  ! . +# )&)  +  ! ! "$%  )& -'.).' -* $  ! . +# )&$ -0 $  ! ! "%  )&+ -'.).' -* $  ! . +# )& -0 $  ! ! "%  )&# -'.&&).' -* $  &&! . +# )&0 -0 $  ! ! "%  ))  +  ! ! "$%  )) '()!  !*+ ,$ ! ! "*% ))& --(' -* &$ ,$ ! ( +# ))) -'.).' -* $  ! . +# )) -'.).' -* $  ! . +# ))$ -'.).' -* $  ! . +# ))+ -'.).' -* $  ! . +# ))  +  ! ! "$%  ))#  +  ! ! "$%  ))0 #$#+1* +$&!! * 2 ) #$#+1* +$&!! * 2 ) #$#+1* +$&!! * 2 )&   ! ! +)$ $ +  +  ! ! "$%  +& --(' -* &$ ,$ ! ( +# +) -/.)3' -* $ - ) 3 +# + -'.).' -* $  ! . +# + -'.&&).' -* $  &&! . +# +# -'.&&).' -* $  …

Text truncated - open the document above for the full version.

Schematics

북미향 3.0(DPP)최종_0323.sch-1 - Wed Mar 24 17:03:40 2004 북미향 3.0(DPP)최종_0323.sch-2 - Wed Mar 24 17:03:47 2004 북미향 3.0(DPP)최종_0323.sch-3 - Wed Mar 24 17:03:36 2004 북미향 3.0(DPP)최종_0323.sch-4 - Wed Mar 24 17:03:43 2004 북미향 3.0(DPP)최종_0323.sch-5 - Wed Mar 24 17:03:49 2004 북미향 3.0(DPP)최종_0323.sch-6 - Wed Mar 24 17:03:53 2004

Test Report

IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 1 of 84 Certification of Compliance CFR 47 Part 15 Subpart B Test Report File No. 04-IST-0066 Date of Issue April 16,2004 Model(s) DV-6T844N / Basic Model DV1040 / Buyer Model Kind of Product DVD VCR COMBO Receiver (TV Interface Device) Applicant Daewoo Electronics Corporation. 543, Dangjung-Dong, Kunpo-City, Kyounggi-DO, Korea Manufacturer Daewoo Electronics Corporation. 295, Gondan-dong, Kumi-city, Kyungsangbuk-do, Korea. Test Result Positive Negative Reviewed By Approved By J.H.LEE / EMC Group Manager G. Chung / Chief - Investigations requested : Measurement to the relevant clauses of F.C.C rules and regulations Part 15 Subpart B – Unintentional Radiatiors - The test report with appendix consists of 84 pages. -The test result only responds to the tested sample. -It is not allowed to copy this report even partly without the allowance of IST EMC Laboratory. - This equipment as for has been shown to be capable of continued compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.4 2001. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 2 of 84 TABLE OF CONTENTS Table of contents 2 Information of test laboratory, Environmental condition, Power used 3 Descriptions of test 4-6 Conducted Emission 4 Radiated Emission 5 Output Signal level measurements 6 Output Terminal Conducted Spurious Emission 6 Transfer Switch Isolation Measurement 6 Summary7 ̰ Test Conditions and Data - Emission ୛ Conducted Emission 0.15MHz - 30MHz Test equipment / Data and Plots 8-40 ୛ Radiated Emission 30MHz - 1GHz Test equipment / Data and Plots 41-45 ୛ Output Signal level measurements Test equipment / Data and Plots 46-64 ୛ Output Terminal Conducted Spurious Emission 30MHz - 1GHz Test equipment / Data and Plots 65-74 ୛ Transfer Switch Isolation Measurement 30MHz - 1GHz Test equipment / Data and Plots 75-84 Information OF TUNERS Manufacture Manufacture Name LG Innotek Co., Ltd. TADM-H101F LG Innotek Co., Ltd. TADM-H201F SAMSUNG Electric Co., Ltd. TCMN0682PA20B4 Korea ALPS TMZH2-030A IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 3 of 84 INFORMATIONS OF TEST LABORATORY EMC LABORATORY of IST Co., Ltd.(FCC Filing Lab) San 21-8, Goan-Ri, Baekam-Myun, Yongin-City Kyonggi-Do, 449-860, Korea TEL : +82 31 333 4093 FAX : +82 31 333 4094 ENVIRONMENTAL CONDITIONS Temperature 18 ୅ Humidity 47 % Atmospheric pressure 1002 mbar POWER SUPPLY SYSTEM USED Power supply system 120Vac , 60Hz PRODUCT INFORMATIONS Power supply system 120Vac , 60Hz Power consumption 24W (Supplementary 4W) Installation Conditions Horizontal / Relative humidity under 80% Signal type NTSC COLOR Antenna Input/output U/V-mixed : 75˟ unbalanced Clock display 12hrs AM/PM Timer Recording 8 Programs a year VIDEO S/N (VCR) Over 45dB (Standard recording) Size(WዥHዥD) 435 ዥ93ዥ255 mm Weight 4.5Kg VIDEO input 1.0 Vp-p unbalanced, RCA JACK AUDIO input -8.8dBm, RCA JACK VHF output 3 or 4 CH -EMC suppression device is not used during the test. - Please refer to user’s manual. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 4 of 84 DESCRIPTIONS OF TEST Conducted Emissions: The measurement were performed over the frequency range of 0.45MHz to 30MHz using a 50 ಳ /50uH LISN as the input transducer to a Spectrum Analyzer or a Field Intensity Meter. The measurements were made with the detector set for "Peak" amplitude within an bandwidth of 10KHz or for "quasi-peak" within a bandwidth of 9KHz. - Procedure of Test The line-conducted facility is located inside a shielded room No.1. A 1m X 1.5m wooden table 80cm height is placed 40cm away from the vertical wall and 1.5m away from the other wall of the shielded room. The R/S ESH3-Z5 and EMCO 3825/2 LISN are bonded to bottom of the shielded room. The EUT is located on the wooden table with distance more than 80cm from the LISN and powered from the EMCO LISN .The peripheral equipment is powered from the other LISN. Power to the LISNs are filtered by a noise cut power line filters. All electrical cables are shielded by braided tinned steel tubing with inner I 1.2cm. If the EUT is a DC-powered device, power will be derived from the source power supply it normally will be powered from and this supply lines will be connected to the EMCO LISN. All interconnecting cables more than 1m were shortened by non-inductive bundling to a 1m length. Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to their normal operating conditions. The RF output of the LISN was connected to the R/S receiver to determine the frequency producing the maximum emission from the EUT. The frequency producing the maximum level was reexamined using Quasi-Peak mode by manual measurement, after scanned by automatic Peak mode for frequency range from 0.45 to 30MHz. The bandwidth of the receiver was set to 10kHz. The EUT, peripheral equipment, and interconnecting cables were arranged and manipulated to maximize each EME emission. 215 >150 >40 80 Receiver EUT LISN 80 t 80 80 40 t 80 Measuring apparatus Mains Filter Mains Front side Equipment under test Coaxial cable Artificial mains networ k Screened room Non-metallic support 80 < Side View > < Concept Drawing > IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 5 of 84 DESCRIPTION OF TEST Radiated Emissions: The measurement was performed over the frequency range of 30MHz to 1GHz using antenna as the input transducer to a Spectrum analyzer or a Field Intensity Meter. The measurement was made with the detector set for "quasi-peak" within a bandwidth of 120KHz. - Procedure of Test Preliminary measurements were made at 3 meter using bi-conical and log-periodic antennas, and spectrum analyzer to determine the frequency producing the max. emission in anechoic chamber. Appropriate precaution was taken to ensure that all emission from the EUT were maximized and investi…

Text truncated - open the document above for the full version.

Test Report

IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 31 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TMZH2-030A (ALPS) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.445 44.7 32.4 57.0 47.0 12.3 14.6 0.779 45.1 26.4 56.0 46.0 10.9 19.6 0.943 45.0 25.5 56.0 46.0 11.0 20.5 1.437 43.4 21.3 56.0 46.0 12.6 24.7 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 32 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TMZH2-030A (ALPS) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.221 44.1 42.0 62.8 52.8 18.7 10.8 0.930 40.5 22.8 56.0 46.0 15.5 23.2 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 33 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.151 47.4 13.8 66.0 56.0 18.6 42.2 0.517 43.2 24.8 56.0 46.0 12.8 21.2 0.803 43.9 22.2 56.0 46.0 12.1 23.8 1.067 43.0 23.4 56.0 46.0 13.0 22.6 2.321 41.6 25.3 56.0 46.0 14.4 20.7 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 34 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.232 44.7 36.5 62.4 52.4 17.7 15.9 1.074 39.8 19.2 56.0 46.0 16.2 26.8 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 35 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.568 44.7 24.9 56.0 46.0 11.3 21.1 0.723 44.9 25.7 56.0 46.0 11.1 20.3 0.878 44.7 23.2 56.0 46.0 11.3 22.8 1.029 44.6 21.5 56.0 46.0 11.4 24.5 2.316 43.2 25.0 56.0 46.0 12.8 21.0 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 36 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.154 48.3 38.7 65.8 55.8 17.5 17.1 0.260 44.2 32.9 61.4 51.4 17.2 18.5 1.023 41.2 19.4 56.0 46.0 14.8 26.6 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 37 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.391 44.3 28.0 58.0 48.0 13.7 20.0 0.621 44.2 20.1 56.0 46.0 11.8 25.9 0.779 44.3 22.2 56.0 46.0 11.7 23.8 0.937 44.1 23.3 56.0 46.0 11.9 22.7 1.278 43.3 21.5 56.0 46.0 12.7 24.5 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 38 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.275 43.8 33.5 61.0 51.0 17.2 17.5 1.073 39.9 18.9 56.0 46.0 16.1 27.1 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 39 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.161 48.4 41.6 65.4 55.4 17.0 13.8 0.435 44.6 32.1 57.2 47.2 12.6 15.1 0.598 45.1 28.6 56.0 46.0 10.9 17.4 0.758 45.2 27.2 56.0 46.0 10.8 18.8 0.923 45.2 24.3 56.0 46.0 10.8 21.7 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 40 of 84 Conducted Emissions (Mains Terminal Disturbance Voltages) Tuner : TCMN0682PA20B4 (SAMSUNG) Measurement [dBᎭ] Limit [dBᎭ] Margin [dB] Freq. [MHz] Q-peak Average Q-peak Average Q-peak Average 0.151 47.0 12.4 66.0 56.0 19.0 43.6 0.217 45.4 42.6 62.9 52.9 17.5 10.3 0.272 44.8 40.4 61.1 51.1 16.3 10.7 0.925 41.3 20.1 56.0 46.0 14.7 25.9 Note : The insertion loss, 0.8dB, is negligible compare with the margin evaluated. IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 41 of 84 TEST CONDITIONS AND DATA Radiated Emissions [Applicable] ୛ Test Equipment Used The test equipment used is calibrated in regular for every year. Model Name Manufacturer Descriptions ESVP Rohde & Schwarz Test Receiver VULB9160 Schwarzbeck Antenna EZM Rohde & Schwarz Spectrum Monitor ୛ Auxiliary Equipment Used Model Name Manufacturer Descriptions 14C5NT Daewoo Electronics. Color TV Receiver ୛ Accessories including cables Name Length Port and Descriptions RCA 1.5m Video / Audio S-Video 1.5m ୛ Environmental Conditions Temperature 18୅ Humidity 50 ୿ Atmosphere pressure 1002mbar ୛ Test Program DVD Playback during VCR record, DVD Playback, RF Receiving during VCR record, VCR Playback ୛ Test Area Open Area Test Site #2 Note : IST Co., Ltd. EMC LABORATORY TEST REPORT NO. : 04-IST-0066 42 of 84 Radiated Emissions (Disturbance Radiation) [Applicable] Tuner : TADM-H101F (LG) System CH Freq. (MHz) Pol. (H/V) Limits (dBuV/m) Result (dBuV/m) Margin (dB) DVD Playback 114.6 H 43.5 33.5 10.0 during 216.0 H 43.5 40.1 3.4 VCR record 270.0 H 46.0 40.0 6.0 442.0 V 46.0 41.5 4.5 540.0 V 46.0 40.2 5.8 743.2 V 46.0 42.3 3.7 DVD Playback 111.6 H 43.5 35.0 8.5 Mode 216.0 H 43.5 40.4 3.1 270.0 V 46.0 42.5 3.5 313.4…

Text truncated - open the document above for the full version.

Test Setup Photos

IST Co., Ltd. EMC LABORATORY Test Setup Photos. Ref. No: 04-IST-0066 1 of 2 Test Setup Photos – Radiated Emissions Front View Rear View IST Co., Ltd. EMC LABORATORY Test Setup Photos. Ref. No: 04-IST-0066 2 of 2 Test Setup Photos – Conducted Emissions Front View Rear View

Contact Information

Applicant

Youjin Choi(Manager)
[email protected]82-31-639-7554Fax: 82-31-639-7961

Test Firm

IST Co., LtdBong Kyoon Bae
@.com82-31-333-4093Fax: 82-31-333-4094

Technical Specifications

#Rule PartsFrequency RangePower Output
215B62.74 MHz - 71.81 MHz-
Grant Notes
Tuner :LG/TADM-H101F or TADM-H201F; Samsung/TCMN0682PA20B4; Korea Alps/TMZH2-030A.

Other Applications from WINIA Electronics Co., Ltd.

Microwave Oven - FCC ID C5F7NF1CMO900N - WINIA Electronics Co., Ltd.
C5F7NF1CMO900N

Microwave Oven

Nov 23, 2014

Equipment Class

8CC - Part 18 Consumer Device
Commercial Microwave Oven - FCC ID C5F7NF9PMO100N - WINIA Electronics Co., Ltd.
C5F7NF9PMO100N

Commercial Microwave Oven

Mar 25, 2013

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID C5F7NF22MO110N - WINIA Electronics Co., Ltd.
C5F7NF22MO110N

Microwave Oven

Jan 23, 2013

Equipment Class

8CC - Part 18 Consumer Device
Commercial Microwave Oven - FCC ID C5F7NF9FMO120N - WINIA Electronics Co., Ltd.
C5F7NF9FMO120N

Commercial Microwave Oven

May 06, 2012

Equipment Class

8CC - Part 18 Consumer Device
Commercial Microwave Oven - FCC ID C5F7NF9FMO180N - WINIA Electronics Co., Ltd.
C5F7NF9FMO180N

Commercial Microwave Oven

Sep 05, 2011

Equipment Class

8CC - Part 18 Consumer Device