
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TUBE Connect ™ WiFi to Radio Technology Lianda (RTL) Interface Ref 2371202 Overview The TUBE Connect ™ WiFi to Radio Technology Lianda Interface is a WiFi to RTL bridge that can control up to 8 channels of RTL motorized products using the TUBE Connect app for iOS and Android devices. Through the app, users can send immediate RTL commands, create Scenes (a group of motorized products working together) and Schedules (timed events). Users may access their RTL devices from anywhere with the apps’ remote access feature. Though TUBE Connect is a single-zone controller, (2) devices can be joined within the same system for multi-zone control. The TUBE Connect interface also serves as an IP to RTL bridge for 3rd party control systems. Technical Specifications • 120V AC; 50-60Hz • Ultra-Low Power Wi-Fi (802.11 a/b/g/n) • Dimensions: 3.64" L x 2.35" W x 1.95" H • Radio Frequency: o RTS 433.92 MHz o WiFi 2.4 & 5 GHz - • Operating Temperature Range: 41°F – 113°F (5°C to 45°C) • iOS Version: iOS 7 and Higher • Android Version: Jellybean or Higher • FCC ID: DWNMYRTL • Rated Current (Amps): 10 to 50 milliamps • Insulation Class: Class II • Shipping Weight: Product 1lb • Enclosure o PE o UL94V-0 Flame Rating o RoHS compliant • For Indoor Use Only • Any other compatible devices/systems o Amazon Alexa o IFTTT • Warranty: 2 years • Certifications o UL o FCC Minimum Distance Statement The antenna of this product, under normal use conditions, is at least 20cm away from the body of the user. This would classify this product as a mobile device. Features Summary • Control for up to 8 RTL channels per myLink™ from iOS and Android devices • Join 2 TUBE interfaces on the same network for multi-zone control • Automate window coverings with scenes and schedules • Supports UP/DOWN/STOP commands • Remote Access • Integration with third-party systems over IP • Compatible with Somfy Synergy API • Compatible with Amazon Alexa and IFTTT What’s in The Box • 2171202 TUBE Connect ™ WiFi to Radio Technology Lianda Interface • Quick Start Guide Connections & Indicators Dimensions Best Wiring Practices Before installing TUBE Connect, make sure that the RTL system is fully operational with all motor limits set and a programmed TUBE RTL transmitter. Plan to install one TUBE Connect per zone. Actual specification and RF range will vary depending on number of RTL channels and environmental conditions (building materials, RF interference, etc.). This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1} The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiver's or receiver's internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment ( per WiFi module certification)). This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. L' utilisation de ce dispositit est autorisee seulement aux conditions suivantes: (1) ii ne doit pas produire de brouillage et(2) I' utilisateurdu dispositit doit etre pret a accepter tout brouillage radioelectrique re9u, meme si ce brouillage est susceptible de compromettr,e le fonctionnement du dispositif. Le present appareil est conforme aux CNR d'lndustrie Canada applicables aux appareils radio exempts de licence. L 'exploitation est autorisee aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouil/age est susceptible d'en compromettre le fonctionnement.
September 30, 2020 To whom it may concern: We, the undersigned, hereby authorize, Wei Li, Advanced Compliance Lab, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Lab on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing Advanced Compliance as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, James Hellander Engineering Mgr. Somfy Systems, Inc.
August 28, 2020 FCC ID: DWNMYRTL IC: 12049A-MYRTL FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the schematics, block diagram, operational description of the EUT treated as confidential. The information contained within is a result of extensive investment and development effort by Somfy Systems, Inc. and its disclosure will compromise Somfy's Intellectual Property and competitive edge. We thus ask the FCC and IC NOT to publish the information mentioned above, in order to protect Somfy's Intellectual Property. Regards, Somfy Systems, Inc. Jim Hellander Industrial Operations Mgr.
Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 25 Figure 7.1 EUT Front View Figure 7.2 EUT Back View Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 26 Figure 7.3 EUT Left Side View Figure 7.4 EUT Right Side View Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 27 Figure 7.5 EUT Top View Figure 7.6 EUT Bottom View
Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT Figure 2.2 ID Label Location Somfy System Inc Tube Connect RTL Smart Bridge Model: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL Contains FCC ID: S9J4144 IC:4979A-4144 This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.1 ID Label (statement shown in the manual) ID Label
Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 28 Figure 7.7 Inside View AC adapter removed Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 29 Figure 7.8 Power Supply Board Component Side Figure 7.9 RF Board Component Side Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 30 Figure 7.10 RF Board Foil Side Figure 7.11 Power Supply Board Foil Side
ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of PRODUCT NAME: Tube Connect RTL Smart Bridge MODEL/PARTS: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL August 28, 2020 This report concerns (check one): Original grant x Class II change Equipment type: Low Power Intentional Radiator Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? yes no x If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR [10-1-90 Edition] provision. Report prepared for: Somfy System Inc. Report prepared by: Advanced Compliance Lab Report number: 0048-200810-01 Rev. A The test result in this report IS supported and covered by the NVLAP accreditation 210 Cougar Court Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 2 Table of Contents Report Cover Page ..................................................................................................... 1 Table of Contents ....................................................................................................... 2 Figures ........................................................................................................................ 3 1. GENERAL INFORMATION................................................................................ 4 1.1 Verification of Compliance ...................................................................... 4 1.2 Equipment Modifications ........................................................................ 5 1.3 Product Information ................................................................................ 6 1.4 Test Methodology ..................................................................................... 6 1.5 Test Facility .............................................................................................. 6 1.6 Test Equipment ........................................................................................ 6 1.7 Statement for the Document Use ............................................................. 7 2. PRODUCT LABELING ........................................................................................ 8 3. SYSTEM TEST CONFIGURATION ................................................................... 9 3.1 Justification .............................................................................................. 9 3.2 Special Accessories ................................................................................... 9 3.3 Configuration of Tested System ............................................................... 9 4. SYSTEM SCHEMATICS ..................................................................................... 13 5. CONDUCTED EMISSION DATA ....................................................................... 14 5.1 Test Methods and Conditions .................................................................. 14 5.2 Measurement Instrument Configuration for Conducted Emission ........ 14 5.3 Testing Data ............................................................................................. 15 6. RADIATED EMISSION DATA............................................................................ 18 6.1 Field Strength Calculation ....................................................................... 18 6.2 Test Methods and Conditions .................................................................. 18 6.3 Test Data ................................................................................................... 18 6.4 Occupied Bandwidth ................................................................................ 19 7. PHOTOS OF TESTED EUT ................................................................................. 24 Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 3 Figures Figure 2.1 ID Label .................................................................................................... 8 Figure 2.2 Location of ID Label ................................................................................ 8 Figure 3.1 Radiated Test Setup ................................................................................. 11 Figure 3.2 Conducted Test Setup .............................................................................. 11 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 5.1 Line Conducted ........................................................................................ 16 Figure 5.2 Neutral Conducted .................................................................................. 18 Figure 6.1 Bandwidth Plot ........................................................................................ 22 Figure 6.2 Pulse Train Timing .................................................................................. 23 Figure 7.1 EUT Top View.......................................................................................... 27 Figure 7.2 EUT Back/Side View ................................................................................ 28 Figure 7.3 Inside View ............................................................................................... 29 Figure 7.4 PCB Component Side .............................................................................. 30 Figure 7.5 Foil Side .................................................................................................... 31 Figure 7.6 WIFI Module (FCC Certified)................................................................. 32 Tube…
Text truncated - open the document above for the full version.
Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 10 Standard Orientation (X) Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 11 Figure 3.1 Radiated Test Setup Tube Connect RTL Smart Bridge Model No: 2371202 FCC ID: DWNMYRTL IC:12049A-MYRTL ________________________________________________________________________________ 12 Figure 3.2 Conducted Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Ysia 1, Ysia 5, Ysia 5 TDBU HP Zigbee II, 5175210B, 5175211B, 5175066B
Equipment Class
DTS - Digital Transmission System
Ysia 5 Variation HP Zigbee II, 5171079B
Equipment Class
DTS - Digital Transmission System
TDBU 25 WF Zigbee HP 5183668
Equipment Class
DTS - Digital Transmission System
Decoflex RTS In-Wall Mount 1810830
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
ROLL UP2 24 Zigbee HP LI-ON 5178669
Equipment Class
DTS - Digital Transmission System