FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Somfy Systems/
  3. DWNSON40R2ZBWF

DWNSON40R2ZBWFDC Tubular Motor, SONESSE2 40 Zigbee HP LI-ION

Somfy Systems
DC Tubular Motor, SONESSE2 40 Zigbee HP LI-ION - FCC ID DWNSON40R2ZBWF - Somfy Systems
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 16, 2024
Application Purpose
Original Equipment
Date of Application
Jul 16, 2024
Equipment Note
DC Tubular Motor, SONESSE2 40 Zigbee HP LI-ION
Frequency Range
2405.00000000 - 2480.00000000
Company
Somfy Systems
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

O RIGINAL INSTRUCTIONS Complete instruction guide available online on www.somfy.info 1 3 2 x2 x3 12 s START UPDRIVE SETTING USE DRIVE RESETTING Short installation guide UP DOWN This drive does not require any maintenance operation. STOPMY For initial unpackaging of drive, wake up the drive by briefly pressing the motor head programming button or plugging in the charger. This reset deletes all programmed control points, all end limit settings, resets the favourite (my) position for the drive and leaves the current Zigbee network. From the Application “Help me by Somfy” scan the QR code here to find complete setting instructions. “Help me by Somfy” available on stores WAKE UP THE DRIVE To set the drive, download "TaHoma pro" application available on stores Once the "TaHoma pro" application is downloaded, open the app and follow the instructions to set the drive. INSTRUCTIONS TO BE RESPECTED These instructions apply to all SONESSE2 40 Zigbee HP LI-ION drive, the different versions of which are available in the current catalogue. FIELD OF APPLICATION The Sonesse 40 drives are designed to motorise all types of: –Interior vertical blinds which front rail moves solely by gravity with a mass less than 15 kg. –Tiltable venetian blinds which bottom lath can be lifted at least by 4 cm when an upward force of 150 N is applied to the bottom lath positioned at 16 cm from the fully extended position. LIABILITY Please read these instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the instructions detailed in the attached Safety instructions document must also be observed. The drive must be installed by a motorisation and home automation professional, according to instructions from Somfy and the regulations applicable in the country in which it is commissioned. It is prohibited to use the drive outside the field of application described above. Such use, and any failure to comply with the instructions given in this guide and in the attached Safety instructions document, absolves Somfy of any liability and invalidates the warranty. The installer must inform its customers of the operating and maintenance conditions for the drive and must provide them with the instructions for use and maintenance, and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation on the drive must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain additional information, contact a Somfy adviser or go to the website www.somfy.com. SAFETY INSTRUCTIONS FOR WIRING Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve. Attach cables to prevent any contact with moving parts. If the drive is used outdoors, and if the power supply cable is a type H05-VVF cable, the cable should be installed in a UV-resistant duct, e.g. under a gland. Leave the drive power supply cable accessible: the product must be easily replaceable. Always make a loop in the power supply cable to prevent water entering the drive. WARNING To ensure electrical safety, this Class III drive must be powered by a «SELV» voltage source (Safety Extra Low Voltage). The drive must be installed by a professionally qualified person (electrical specialist according to DIN VDE 1000-10) for drives and automations in the building services sector in accordance with the Somfy instructions and the applicable regulations in the country of commissioning. Using this drive with any products which are not listed in the attached «Compatibility matrix» document shall also render invalid any Somfy warranty and release Somfy from any liability. For the purposes of recharging the battery, only use the detachable supply unit provided with this appliance. Improper using battery pack may cause overheat, fire, explosion, resulting in serious injury or death. Do not expose the drive or battery to excessive temperatures. There is a risk if terminals of the battery-operated drive or battery being short circuited by metal objects. Ensure battery is fully charged prior to installation on site. To increase the life of the battery, it is recommended to fully charge it every other year. 5177210A EN EN SONESSE2 40 Zigbee HP LI-ION SPECIFIC INSTRUCTIONS FOR ASSEMBLY SONESSE2 40 Zigbee HP LI-ION : interior diameter of the tube has to be Ø 37 mm or greater. Frequency bands and Maximum power used Power supply 2.4 GHz - 2.4835 GHz e.r.p. <63mW [USA, Australia, Canada] 2.4 GHz - 2.4835 GHz e.r.p. <10mW [Other countries] 15V DC-1A class 2 power supply SELV + LPS 0 °C to 40 °CCharging temperature The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by SOMFY ACTIVITIES SA is under license. Other trademarks and trade names are those of their respective owners. ReferenceDesignation 5177206SONESSE2 40 Zigbee HP LI-ION FCC warning statement: - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. - This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. - Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF RADIATION EXPOSURE STATEMENT: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and any part of your body. FCC ID: D…

Text truncated - open the document above for the full version.

Attestation Statements

Somfy Systems, Inc., 121 Herrod Blvd., Dayton, NJ 08810 CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: 04-04-2024 FCC ID: DWNSON40R2ZBWF To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Somfy Systems, Inc. (“t he applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. Contact Person: Jim Hellander Company Name: Somfy Systems, Inc. (FRN # 0006579940) Company US Address: 121 Herrod Blvd., Dayton, NJ 08810 Email: [email protected] Sincerely yours, Jim Hellander

Attestation Statements

Somfy Systems, Inc. 121 Herrod Blvd., Dayton, NJ 08810 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04-04-24 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: DWNSON40R2ZBWF Somfy Systems, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Jim Hellander Somfy Systems, Inc. 121 Herrod Blvd., Dayton, NJ 08810 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04-04-24 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: DWNSON40R2ZBWF Somfy Systems, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered”. equipment. Sincerely, Jim hellander

Cover Letter(s)

Date: April 4, 2024 Ref: Application for FCC & ISED Certification on Somfy Tx under FCC ID: DWNSON40R2ZBWF & IC:12049A-SON40R2ZBWF Ctrl#: 0048-240404-01 From: Wei Li, Advanced Compliance Laboratory To Whom It May Concern: Dear Sir/ Madam, We, Advanced Compliance Laboratory, as EMC testing lab and agent, would like to represent the applicant, Somfy Systems to apply for your approval on product authorization for new certification under FCC ID: DWNSON40R2ZBWF & IC:12049A-SON40R2ZBWF. The investigation for the EMC performance of the EUT(s), DC Tubular Motor, Sonesse2 40 Zigbee HP LI-ION was performed in March 2024 on behalf of the applicant. It was found that EUTs comply with the requirements of FCC Part 15.247 & RSS-247, RSS-Gen. The system was configured as the typical condition during the test. Enclosed please find the test data/report with application forms. The measurement facility used to collect the test data is BUREAU VERITAS ADT (Shanghai) Corporation, located at No. 829, Xinzhuan Road, Shanghai, P.R.China (201612), which is currently accredited by A2LA with cert # 2343.01. Should you need more information, please contact me at (908) 392-3378 or email me to [email protected]. Your attention is highly appreciated. Sincerely, Wei Li Manager Advanced Compliance Laboratory, Inc. 210 Cougar Court Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Lab

Cover Letter(s)

April 4, 2024 FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the schematics, block diagram, operational description of the EUT treated as confidential. The information contained within is a result of extensive investment and development effort by Somfy Systems, Inc. and its disclosure will compromise Somfy's Intellectual Property and competitive edge. We thus ask the FCC and IC NOT to publish the information mentioned above, in order to protect Somfy's Intellectual Property. Regards, Somfy Systems, Inc. Jim Hellander Electronics Engineer

Cover Letter(s)

FCC ID: DWNSON40R2ZBWF & IC:1209A-SON40R2ZBWF TO WHOM IT MAY CONCERN: 04//04/24 To whom it may concern: I, the undersigned, hereby authorize Wei Li, Advanced Compliance Lab to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. In authorizing Advanced Compliance Lab as our representative, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Somfy Systems, Inc. Jim Hellander

External Photos

PHOTOS OF EUT: SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF The following photos show the External details of the EUT. Side Photo (cylinder front, symmetrical) Side Photo ( cylinder back, symmetrical) Top Photo Bottom Photo

ID Label/Location Info

FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF Sonesse2 40 WF Zigbee HP Li-Ion Page : 5 / 31 "In accordance with 0.459&0.457 of CFR47, all rights are reserved. Reproduction in whole or in parts is prohibited without the written consent of the copyright owner” FCC INFORMATION ON PRODUCT FCC /IC Label Design : Somfy Sonesse2 40 ZIGBEE HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF

Internal Photos

PHOTOS OF EUT: SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF The following photos show the Internal details of the EUT. EUT Open View SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF 2 EUT Internal View SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF 3 EUT Main PCB Front SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF 4 EUT Main PCB Back SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF 5 EUT Digital I/O Section SONESSE2 40 Zigbee HP LI-ION FCC ID: DWNSON40R2ZBWF IC: 12049A-SON40R2ZBWF 6

RF Exposure Info

Report No.: LDF-ESH-P24020363B-3 Page No. 1 / 7 Report Format Version: 6.1.1 MPE Test Report Report No.: LDF-ESH-P24020363B-3 FCC ID: DWNSON40R2ZBWF Product: DC tubular motor Model: SONESSE2 40 Zigbee HP LI-ION Received Date: Feb.18, 2024 Test Date: Feb.18 to Mar.21, 2024 Issued Date: Mar.25, 2024 Applicant: Somfy Systems Address: 121 Herrod Blvd, Dayton, NJ 08810, USA Manufacturer: Somfy Systems Address: Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P24020363B-3 Page No. 2 / 7 Report Format Version: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 3 1 General Information ........................................................................................................................... 5 1.1 General Description of EUT............................................................................................................ 5 2 RF Exposure ..................................................................................................................................... 7 2.1 Limits For Maximum Permissible Exposure (MPE) ......................................................................... 7 2.2 MPE Calculation Formula ............................................................................................................... 7 2.3 MPE Calculation Formula ............................................................................................................... 7 2.4 Calculation Result of Maximum Permissible Exposure.................................................................... 7 Report No.: LDF-ESH-P24020363B-3 Page No. 3 / 7 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued LDF-ESH-P24020363B-3 Original release Mar.25, 2024 1 Certificate of Conformity Product: DC tubular motor Brand: somfy. Model: S0NESSE2 40 Zigbee HP LI-ION Applicant: Somfy Systems Test Date: Feb.18 to Mar.21, 2024 Sta ndards: FCC Part 2 (Section 2.1 091) KDB 447498 D0 1 General RF Exposure Guidance v06 IEEE C95.1 -1992 The above equipment has been tested by BUREAU VERITAS ADT (Shanghai) Corporation, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample's EMC characteristics under the conditions specified in this report. Prepared by : , Date: Mar.25, 2024 Yan ZHOU Project Engineer Approved by : , Date: Mar.25, 2024 Report No.: LDF-ESH-P24020363B-3 Page No. 4 I 7 Report Format Version: 6. 1. 1 Report No.: LDF-ESH-P24020363B-3 Page No. 5 / 7 Report Format Version: 6.1.1 2 General Information 2.1 General Description of EUT For BLE Product DC tubular motor Brand Test Model SONESSE2 40 Zigbee HP LI-ION Power Rating 12V, 3,5A; Rated torque: 4Nm; Operating time: 5minutes. Modulation Type GFSK Modulation Technology Bluetooth Low Energy 5.0 Operating Frequency 2402MHz ~ 2480MHz Number of Channel 40 Antenna Type External Antenna Antenna Connector -- Antenna Gain 1 dBi Note: 1. For more details, please refer to the User’s manual of the EUT. Report No.: LDF-ESH-P24020363B-3 Page No. 6 / 7 Report Format Version: 6.1.1 For Zigbee Product DC tubular motor Brand Test Model SONESSE2 40 Zigbee HP LI-ION Power Rating 12V, 3,5A; Rated torque: 4Nm; Operating time: 5minutes. Modulation Type O-QPSK Modulation Technology 6LoWPAN Operating Frequency 2405MHz to 2480MHz Number of Channel 16 Antenna Type External Antenna Antenna Connector -- Antenna Gain 1dBi 2.2 Test Facility Laboratory Name: Bureau Veritas ADT (ShangHai) Corporation Laboratory Address: No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China Test Location: No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China A2LA Lab Code: 2343.01 FCC-Recognized Accredited Testing Lab: CN1213 ISED Recognized Lab: 6392A FCC Accredited Test Site Number: 176467 Report No.: LDF-ESH-P24020363B-3 Page No. 7 / 7 Report Format Version: 6.1.1 3 RF Exposure 3.1 Limits For Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncon…

Text truncated - open the document above for the full version.

Test Report

A B C D E F A B C D E F 1 23 4 5 6 7 8 1 2 3457 A3 6 This drawing shall not be used, reproduced or passed on in any way, in full or in part, without SOMFY written approval. All rights reserved DIMENSIONING ACCORDING TO ISO-8015 GENERAL TOLERANCES APPLIED TO UNSPECIFIED SHAPES MATERIAL: ARTICLE: Modified By: Scale.: REVMODIFICATION DESCRIPTION DATE NAME N : ° L2 2 ±0.5 L13 6 1 max: 3.8 L 3 L4 L3 Lenght is free 3 L5 007 Some requirements precised BOM suppressed 22/02/24FR 006Part index update24/1/11ALP 005Part index update24/1/8ALP 004 Update the shrinkable sleeve diameter23/11/29 ALP 003 Modification according to ECR002093 23/8/7ALP 001modify 190±3 to 188±221/8/4LJ REFERENCEDESIGNATIONLL1L2L3L4L5 5042191B Sonesse 30 Ultra Zigbee 57957331 ± 0.5188 ±2623 5042193B Sonesse 28 ext battery Zigbee 32632031 +0.5 -0 185 ±3623 5173260A Sonesse 28 Basic ZBO57957331 ± 0.5228 ±2623 5172284A Sonesse 40 Zigbee50749427 ± 0.5178 ±2 1327 ± 0.5 0.5 CZ REQUIREMENTS 1.ALL UNSPECIFIED LINEAR TOLERANCES, PLEASE REFER TO RIGHT TABLE; 2.FREQUENCY:2400 MHz-2483 MHz,GAIN:[+1,+2]dBi VSWR:[1,2],INPUT IMPEDANCE:50 Ohms nominal 3.THE DIMENSION WITH NUMBER IS CRITICAL 4..PART MUST COMPLY WITH CURRENT RoHS DIRECTIVE AND WITH RESTRICTED SUBSTANCES REQUIREMENTS LAY DOWN IN PSSH_DOC168704; (Distance of heat shrinkable tube and copper pipe) (Bare size between shield solder joint and copper tube) 7 (007) (007) (007) Cable RF1.37-LOSS AWG#30 5 6 Copper pipe Solder joint 4 Heat shrinkable sleeve color: white 2mm 1 2 Copper pipe IPEX1.37 plug P/N:20351-112R-37 Heat shrinkable tube color white GD Antenna Soness ZigBee 007 PETRIS Anny-Laure (petran01) - - - 3/2 . GEO171383 Measurement ISO8015 AD -DOC174349 R

Test Report

Report No.: LDF-ESH-P24020363B-2 Page No. 1 / 47 Report Format Verision: 6.1.1 FCC Test Report Report No.: LDF-ESH-P24020363B-2 FCC ID: DWNSON40R2ZBWF Product: DC tubular motor Test Model: SONESSE2 40 Zigbee HP LI-ION Received Date: Feb.18, 2024 Test Date: Feb.18 to Mar.21, 2024 Issued Date: Mar.25, 2024 Applicant: Somfy Systems Address: 121 Herrod Blvd, Dayton, NJ 08810, USA Manufacturer: Somfy Systems Address: Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P24020363B-2 Page No. 2 / 47 Report Format Verision: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 4 1 Certificate of Conformity .................................................................................................................... 5 2 Summary of Test Results ................................................................................................................... 6 2.1 Test Instruments ............................................................................................................................ 7 2.2 Measurement Uncertainty .............................................................................................................. 8 2.3 Modification Record ....................................................................................................................... 8 3 General Information ........................................................................................................................... 9 3.1 General Description of EUT............................................................................................................ 9 3.2 Description of Test Modes .............................................................................................................10 3.2.1 Test Mode Applicability: ................................................................................................................. 11 3.2.2 Test Condition: ..............................................................................................................................12 3.3 Description of Support Units ..........................................................................................................13 3.4 General Description of Applied Standards .....................................................................................13 4 Test Procedure and Results ..............................................................................................................14 4.1 AC Power Conducted Emission.....................................................................................................14 4.1.1 Limits ............................................................................................................................................14 4.1.2 Test Procedures ............................................................................................................................14 4.1.3 Deviation from Test Standard.........................................................................................................14 4.1.4 Test Setup .....................................................................................................................................15 4.1.5 EUT Operating Conditions .............................................................................................................15 4.1.6 Test Results ..................................................................................................................................16 4.2 Minimum 6dB Bandwidth...............................................................................................................18 4.2.1 Limit ..............................................................................................................................................18 4.2.2 Test Setup .....................................................................................................................................18 4.2.3 Test Procedures ............................................................................................................................18 4.2.4 Deviation of Test Standard............................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: LDF-ESH-P24020363B-1 Page No. 1 / 47 Report Format Verision: 6.1.1 FCC Test Report Report No.: LDF-ESH-P24020363B-1 FCC ID: DWNSON40R2ZBWF Product: DC tubular motor Test Model: SONESSE2 40 Zigbee HP LI-ION Received Date: Feb.18, 2024 Test Date: Feb.18 to Mar.21, 2024 Issued Date: Mar.25, 2024 Applicant: Somfy Systems Address: 121 Herrod Blvd, Dayton, NJ 08810, USA Manufacturer: Somfy Sytems Address: Issued By: BUREAU VERITAS ADT (Shanghai) Corporation Lab Address: No. 829, Xinzhuan Road, Shanghai, P.R.China (201612) This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: LDF-ESH-P24020363B-1 Page No. 2 / 47 Report Format Verision: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 4 1 Certificate of Conformity .......................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

James P Hellander(Industrial Operations Manager)
[email protected]609 395-1300Fax: 609-495-8153

Test Firm

BUREAU VERITAS ADT (Shanghai) CorporationOlivia Gao
[email protected]86 24 37602699

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz3.00 mW
Confidentiality
Long Term

Other Applications from Somfy Systems

Ysia 1, Ysia 5, Ysia 5 TDBU HP Zigbee II, 5175210B, 5175211B, 5175066B - FCC ID DWNV2TDBUBL - Somfy Systems
DWNV2TDBUBL

Ysia 1, Ysia 5, Ysia 5 TDBU HP Zigbee II, 5175210B, 5175211B, 5175066B

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
Ysia 5 Variation HP Zigbee II, 5171079B - FCC ID DWNVARBL - Somfy Systems
DWNVARBL

Ysia 5 Variation HP Zigbee II, 5171079B

Aug 18, 2026

Equipment Class

DTS - Digital Transmission System
TDBU 25 WF Zigbee HP 5183668 - FCC ID DWNTDBU25ZB - Somfy Systems
DWNTDBU25ZB

TDBU 25 WF Zigbee HP 5183668

Jun 23, 2026

Equipment Class

DTS - Digital Transmission System
Decoflex RTS In-Wall Mount 1810830 - FCC ID DWNDECOFLEX2 - Somfy Systems
DWNDECOFLEX2

Decoflex RTS In-Wall Mount 1810830

Feb 25, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
ROLL UP2 24 Zigbee HP LI-ON 5178669 - FCC ID DWN-ROLLUPZB24 - Somfy Systems
DWN-ROLLUPZB24

ROLL UP2 24 Zigbee HP LI-ON 5178669

Sep 23, 2025

Equipment Class

DTS - Digital Transmission System