FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mitsumi Electric Co Ltd/
  3. EW4DWMW095A

EW4DWMW095A802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE

Mitsumi Electric Co Ltd
802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE - FCC ID EW4DWMW095A - Mitsumi Electric Co Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 10, 2013
Application Purpose
Original Equipment
Date of Application
Jul 10, 2013
Equipment Note
802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE
Frequency Range
5745.00000000 - 5825.00000000
Company
Mitsumi Electric Co Ltd
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page 1 of 8 DWM-W095A_User_Manual User Manual MITSUMI Wireless LAN Bluetooth Combo Module MODEL DWM-W095A The purpose of this manual is to explain correct way how to integrate module DWM-W095A to the end product. It includes procedures that shall assist you to avoid unforeseen problems. This manual presents information that shows how module and OEM product, where module integrated, complies with regulations in certain regions. Any modifications, not expressly approved by the manufacturer could void the authority to operate in these regions. Content 1. General 2. Hardware Essentials 3. Wireless Utility Guide 4. BT Utility Guide 5. Regulatory Statement 1. General This MITSUMI Wireless LAN Bluetooth Combo Module, model DWM-W095A has to be installed and used in accordance with the technical description/installation instructions provided by the manufacturer. For detail information concerning type approval of this module (e.g. where this module is already pre-approved) please contact the authorized local distributor or manufacturer. The system may only be implemented in the configuration that was authorized. Note that any changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment. Page 2 of 8 DWM-W095A_User_Manual 2. Hardware Essentials Overall Appearance Package Outline LGA Module of 155 pins Dimension Width 17.0 mm x Depth 10.5 mm x Height 1.5 (MAX) mm Weight 0.45g Environmental Conditions Operating Temperature: -10°C to +75°C Operating Humidity: 20% to 85% (None dew) Storage Temperature: -25°C to +85°C Storage Humidity: 20% to 85% (None dew) Page 3 of 8 DWM-W095A_User_Manual 3. WLAN Utility Guide Wireless Network Connection Setting Step-1: Install WLAN Driver (Broadcom 802.11g Network Adapter). (Software supply and support will be done by Broadcom according to the licence agreement.) Step-2: Set the Wireless Zero Configuration property. Startup type: “Automatic”, Service status: “Start”, and click “OK”. Step-3: Select the SSID of WLAN Access Point (AP) which you want to create a connection, and click “Connect”. Then, a connection between the Module DWN-W095A and the WLAN AP is created. Page 4 of 8 DWM-W095A_User_Manual 4. BT Utility Guide Bluetooth Link Setting Step-1: Install the application software for Bluetooth, run the application, and load fi rmware. (Software supply and support will be done by Broadcom according to the licence agreement.) Step-2: Set Event Filter. Step-3: Make Write Scan enable. Step-4: Scan the device (Module DWM-W095A) by the Bluetooth product which you want to establish a link, and set PIN code. Step-5: Send PIN Code Request Reply to the Bluetooth product. Then, a link between the Module DWN-W095A and the Bluetooth product is established. 5. Regulatory Statements - OEM integrators must ensure that its product is electrically identical to Mitsumi’s reference designs. Any modifications to Mitsumi’s reference designs may invalidate regulatory approvals in relation to the product, or may necessitate notifications to the relevant regulatory authorities. - OEM integrators are responsible for regression testing to accommodate changes to designs, new antennas, and host and submit for C2PC filings. Colocation with other transmitter modules will be addressed through filings for those co-located transmitters when necessary or that colocation of other transmitters will be according to applicable KDB guidelines including those for RF exposure -The final system integrator must ensure there is no instruction provided in the user manual or customer documentation indicating how to install or remove the transmitter - Appropriate labels must be affixed to the product that complies with applicable regulations in all respects. The regulatory label on the final system must include the statement: “Contains FCC ID: EW4DWMW095A and/or IC: 4250A-DWMW095A”. - A user’s manual or instruction manual must be included with the product that contains the text as required by applicable law shall be provided to OEM integrators. They may include: 5.1 USA—Federal Communications Commission (FCC) FCC COMPLIANCE STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. INFORMATION TO USER: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna -Increase the distance between the equipment and the receiver. -Connect the equipment to outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. Caution: Exposure to Radio Frequency Radiation. To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be collocated or operating in conjunction with any other antenna or transmitter. …

Text truncated - open the document above for the full version.

Cover Letter(s)

Applicant/Grantee MITSUMI ELECTRIC CO., LTD. FCC ID: EW4DWMW095A Section 15.212 Modular Transmitters Request for Modular Approval Request for Limited Modular Approval Requirements EUT Conditions Comply (Y/N) Single Modular Approval Requirements 1 The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements. See EUT photos Y 2 The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. See schematics Y 3 The modular transmitter must have its own power supply regulation. See schematics Y 4 The modular transmitter must comply with the antenna and transmission system requirements of Sections 15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The “professional installation” provision of Section 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. PIFA antenna is used and module will be equipped to the end product for sale, user will not have chance to change the antenna. Y 5 The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing for compliance with Part 15 requirements. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in Section 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see Section 15.27(a)). The length of these lines shall be the length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting See test setup photos Y equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified and commercially available (see Section 15.31(i)). 6 The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. (A) If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. (B) If the modular transmitter uses an electronic display of the FCC identification number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC certified transmitter module(s).” Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be included in the application for equipment authorization. See user manual and label format Y 7 The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. See user manual Y 8 The modular transmitter must comply with any applicable RF exposure requirements in its final configuration. See user manual Y A limited modular approval may be granted for single or split modular transmitters that do not comply with all of the above requirements, e.g., shielding, minimum signaling amplitude, buffered modulation/data inputs, or power supply regulation, if the manufacturer can demonstrate by alternative means in the application for equipment authorization that the modular transmitter meets all the applicable Part 15 requirements under the operating conditions in which the transmitter will be used. Limited modular approval also may be granted in those instances where compliance with RF exposure rules is demonstrated only for particular product configurations. The applicant for certification must state how control of the end product into which the module will be installed will be maintained such that full compliance of the end product is always ensured.

External Photos

External Photos Model: DWM-W095A Top Bottom

ID Label/Location Info

Label and Label Location Model: DWM-W095A FCC ID: EW4DWMW095A IC: 4250A-DWMW095A The label is razor-printed onto the top of the shield case as above.

Internal Photos

Internal Photos DWM-W095A TOP BOTTOM

RF Exposure Info

FCC Part 1 Subpart I FCC Part 2 Subpart J INDUSTRY CANADA RSS 102 ISSUE 3 RF EXPOSURE REPORT FOR 802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE MODEL NUMBER: DWM-W095A FCC ID: EW4DWMW095A IC: 4250A-DWMW095A REPORT NUMBER: 13J14910-7 ISSUE DATE: JULY 10, 2013 Prepared for MITSUMI ELECTRIC CO., LTD. 1601, SAKAI, ATSUGI-SHI, KANAGAWA- KEN, 243-8533 JAPAN Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 13J14910-7 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 2 of 10 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. Revision History Rev. Issue Date Revisions Revised By -- 07/10/13 Initial Issue V. Tran REPORT NO: 13J14910-7 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 3 of 10 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 4 2. METHODOLOGY .................................................................................................................... 5 3. REFERENCES ........................................................................................................................ 5 4. FACILITIES AND ACCREDITATION ..................................................................................... 5 5. EUT DESCRIPTION ................................................................................................................ 5 6. REQUIREMENTS - LIMITATION OF EXPOSURE ................................................................ 6 6.1. LIMITS .............................................................................................................................. 6 6.1.1. FCC RULES .............................................................................................................. 6 6.1.2. IC RULES .................................................................................................................. 7 6.1.3. LIMITS APPLICABLE TO THE EUT ........................................................................ 7 6.2. EQUATIONS .................................................................................................................... 8 6.3. RESULTS ......................................................................................................................... 9 REPORT NO: 13J14910-7 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 4 of 10 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: MITSUMI ELECTRIC CO., LTD. 1601, SAKAI, ATSUGI-SHI, KANAGAWA- KEN, 243-8533 JAPAN EUT DESCRIPTION: 802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE MODEL: DWM-W095A APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Pass INDUSTRY CANADA RSS 102 ISSUE 3 Pass UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Verification Services Inc. By: Tested By: Thu Chan Vien Tran WiSE Operations Manager WiSE Senior Engineer UL Verification Services Inc. UL Verification Services Inc. REPORT NO: 13J14910-7 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 5 of 10 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 2. METHODOLOGY All calculations were made in accordance with FCC OET Bulletin 65 Edition 97-01 and IC Safety Code 6. 3. REFERENCES All measurements were made as documented in test reports UL CCS Document: _For operation in the 2.4 GHz band: 13U14910-5 FCC IC DTS WLAN Report, 13J14910-2 FCC IC BLUETOOTH Report, and 13J14910-1A FCC IC BLE Report. _For operation in the 5 GHz band: 13U14910-5 FCC IC DTS WLAN Report and 13U14910-6 FCC IC UNII WLAN Report. Output power, Duty cycle and Antenna gain data is excerpted from the applicable test reports. 4. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 47173 Benicia Street, Fremont, California, USA. UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be …

Text truncated - open the document above for the full version.

Test Report

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE MODEL NUMBER: DWM-W095A FCC ID: EW4DWMW095A IC: 4250A-DWMW095A REPORT NUMBER: 13J14910-1_Revision A ISSUE DATE: JULY 03, 2013 Prepared for MITSUMI ELECTRIC CO., LTD. 1601, SAKAI, ATSUGI-SHI, KANAGAWA- KEN, 243-8533 JAPAN Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 13J14910-1A DATE: JULY 03, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 2 of 56 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. Revision History Rev. Issue Date Revisions Revised By -- 04/17/13 Initial Issue F. Ibrahim A 07/13/13 Revised sections 8.2 and 8.3 V. Tran REPORT NO: 13J14910-1A DATE: JULY 03, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 3 of 56 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 5 5. EQUIPMENT UNDER TEST ............................................................................................... 6 5.1. DESCRIPTION OF EUT .............................................................................................. 6 5.2. MAXIMUM OUTPUT POWER...................................................................................... 6 5.3. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 6 5.4. SOFTWARE AND FIRMWARE .................................................................................... 6 5.5. WORST-CASE CONFIGURATION .............................................................................. 6 5.6. DESCRIPTION OF TEST SETUP ................................................................................ 7 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9 7. ANTENNA PORT TEST RESULTS ...................................................................................10 7.1. ON TIME, DUTY CYCLE AND MEASUREMENT METHODS .....................................10 7.1.1. ON TIME AND DUTY CYCLE RESULTS – DECIMAL POINT .............................10 7.1.2. MEASUREMENT METHOD .................................................................................10 7.1.3. DUTY CYCLE PLOTS .........................................................................................11 7.2. 6 dB BANDWIDTH ......................................................................................................12 7.3. 99% BANDWIDTH ......................................................................................................15 7.4. OUTPUT POWER.......................................................................................................18 7.5. AVERAGE POWER ....................................................................................................21 7.6. POWER SPECTRAL DENSITY ..................................................................................22 7.7. CONDUCTED SPURIOUS EMISSIONS .....................................................................25 8. RADIATED TEST RESULTS .............................................................................................29 8.1. LIMITS AND PROCEDURE ........................................................................................29 8.2. TRANSMITTER ABOVE 1 GHz ..................................................................................30 8.3. WORST-CASE BELOW 1 GHz ...................................................................................43 9. AC POWER LINE CONDUCTED EMISSIONS ..................................................................46 10. SETUP PHOTOS ...........................................................................................................50 REPORT NO: 13J14910-1A DATE: JULY 03, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 4 of 56 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: MITSUMI ELECTRIC CO., LTD. 1601, SAKAI, ATSUGI-SHI, KANAGAWA- KEN, 243-8533 JAPAN EUT DESCRIPTION: 802.11abgn 2X2 MIMO + BT/BLE RADIO MODULE MODEL: DWM-W095A SERIAL NUMBER: B4-29 DATE TESTED: MARCH 29 – JULY 02, 2013 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 Part 15 Subpart C Pass INDUSTRY CANADA RSS-210 Issue 8 Annex 8 Pass INDUSTRY CANADA RSS-GEN Issue 3 Pass UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations a…

Text truncated - open the document above for the full version.

Test Report

REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 347 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. MID CHANNEL DATA REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 348 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. HIGH CHANNEL HORIZONTAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 349 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. VERTICAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 350 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. HIGH CHANNEL DATA REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 351 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. 9.2.6 802.11n HT40 SDM MCS8 2TX MODE, 2.4 GHz BAND RESTRICTED BANDEDGE (LOW CHANNEL) LOW CHANNEL RESTRICTED, PEAK, HORIZ LOW CHANNEL RESTRICTED, AVERAGE, HORIZ REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 352 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. LOW CHANNEL RESTRICTED, PEAK, VERT LOW CHANNEL RESTRICTED, AVERAGE, VERT REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 353 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. AUTHORIZED BANDEDGE (HIGH CHANNEL) HIGH CHANNEL BANDEDGE, PEAK, HORIZ HIGH CHANNEL BANDEDGE, AVERAGE, HORIZ REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 354 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. HIGH CHANNEL BANDEDGE, PEAK, VERT HIGH CHANNEL BANDEDGE, AVERAGE, VERT REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 355 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. HARMONICS AND SPURIOUS EMISSIONS LOW CHANNEL HORIZONTAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 356 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. VERTICAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 357 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. LOW CHANNEL DATA REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 358 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. MID CHANNEL HORIZONTAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 359 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. VERTICAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 360 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. MID CHANNEL DATA REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 361 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. HIGH CHANNEL HORIZONTAL REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 362 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMON…

Text truncated - open the document above for the full version.

Test Report

REPORT NO: 13J14910-5 DATE: JULY 10, 2013 FCC ID: EW4DWMW095A IC: 4250A-DWMW095A Page 381 of 412 UL VERIFICATION SERVICES INC. FORM NO: CCSUP4701J 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc. High…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Masashi Tsuchida
[email protected]81-42-310-5822Fax: 81-42-310-5598

Test Firm

Compliance Certification ServicesThu Chan
[email protected]510-771-1122Fax: 510-661-0888

Technical Specifications

#Rule PartsFrequency RangePower Output
315C5.75 GHz - 5.83 GHz283.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Output power is conducted. Device is 2x2 802.11abgn with Bluetooth and BLE combo card module. Approval is limited to OEM installation only in mobile RF exposure configurations. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Mitsumi Electric Co Ltd

Bluetooth HCI module - FCC ID EW4C95 - Mitsumi Electric Co Ltd
EW4C95

Bluetooth HCI module

May 14, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless LAN + BT/BLE Module - FCC ID EW4DWMW314 - Mitsumi Electric Co Ltd
EW4DWMW314

Wireless LAN + BT/BLE Module

Nov 29, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless LAN Module - FCC ID EW4W092 - Mitsumi Electric Co Ltd
EW4W092

Wireless LAN Module

Oct 28, 2013

Equipment Class

DTS - Digital Transmission System
Wireless LAN module - FCC ID EW4DWMW078 - Mitsumi Electric Co Ltd
EW4DWMW078

Wireless LAN module

Feb 07, 2013

Equipment Class

DTS - Digital Transmission System
Wireless LAN Module - FCC ID EW4DW092 - Mitsumi Electric Co Ltd
EW4DW092

Wireless LAN Module

Nov 25, 2012

Equipment Class

DTS - Digital Transmission System